Carbon dioxide absorber and regeneration assemblies useful for power plant flue gas

Disclosed are apparatus and method to treat large amounts of flue gas from a pulverized coal combustion power plant. The flue gas is contacted with solid sorbents to selectively absorb CO.sub.2, which is then released as a nearly pure CO.sub.2 gas stream upon regeneration at higher temperature. The method is capable of handling the necessary sorbent circulation rates of tens of millions of lbs/hr to separate CO.sub.2 from a power plant's flue gas stream. Because pressurizing large amounts of flue gas is cost prohibitive, the method of this invention minimizes the overall pressure drop in the absorption section to less than 25 inches of water column. The internal circulation of sorbent within the absorber assembly in the proposed method not only minimizes temperature increases in the absorber to less than 25.degree. F., but also increases the CO.sub.2 concentration in the sorbent to near saturation levels. Saturating the sorbent with CO.sub.2 in the absorber section minimizes the heat energy needed for sorbent regeneration. The commercial embodiments of the proposed method can be optimized for sorbents with slower or faster absorption kinetics, low or high heat release rates, low or high saturation capacities and slower or faster regeneration kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport Membrane Condenser for Water and Energy Recovery from Power Plant Flue Gas

The new waste heat and water recovery technology based on a nanoporous ceramic membrane vapor separation mechanism has been developed for power plant flue gas application. The recovered water vapor and its latent heat from the flue gas can increase the power plant boiler efficiency and reduce water consumption. This report describes the development of the Transport Membrane Condenser (TMC) technology in details for power plant flue gas application. The two-stage TMC design can achieve maximum heat and water recovery based on practical power plant flue gas and cooling water stream conditions. And the report includes: Two-stage TMC water and heat recovery system design based on potential host power plant coal fired flue gas conditions; Membrane performance optimization process based on the flue gas conditions, heat sink conditions, and water and heat transport rate requirement; Pilot-Scale Unit design, fabrication and performance validation test results. Laboratory test results showed the TMC system can exact significant amount of vapor and heat from the flue gases. The recovered water has been tested and proved of good quality, and the impact of SO 2 in the flue gas on the membrane has been evaluated. The TMC pilot-scale system has been field tested with a slip stream of flue gas in a power plant to prove its long term real world operation performance. A TMC scale-up design approach has been investigated and an economic analysis of applying the technology has been performed.

20 FOSSIL-FUELED POWER PLANTS↗

In-situ measurement of moist flue gas under high pressure using a nafion dryer and FTIR

The formation of the main flue gas species (NOx, SOx, CO2, and CO) in pressurized oxy-fuel combustion can be fundamentally different from oxy-fuel combustion at atmospheric pressure. To accurately obtain the concentration of these gas species in a pressurized oxy-fuel combustor, a gas measurement which maintains the sampling pressure is needed. Very few published studies have accomplished this, and never under the conditions reported herein. In this work, we fire PRB coal in a 100 kWth staged pressurized oxy-fuel combustor (SPOC) under a pressure 15 bara. We utilize a state-of-the-art FTIR (Thermo Scientific Nicolet iS20) with a novel high-pressure gas cell that is under process pressure to measure the in-situ flue-gas concentration in a sampled flow. However, water vapor can significantly interfere with the FTIR measurement, particularly under pressure. To address this problem, we have developed a high-pressure nafion dryer to selectively remove the water vapor from the flue gas while retaining the flue gas species. This approach can significantly increase the signal-noise ratio for the FTIR. By integrating the nafion dryer and the high-pressure gas cell, we were able to successfully measure flue gas species at system pressure with the FTIR.

Cheng, Mao↗

Integrating Waste Heat from CO 2 Removal and Coal-Fired Flue Gas to Increase Plant Efficiency

In project DE-FE0007525, Southern Company Services demonstrated heat integration methods for the capture and sequestration of carbon dioxide produced from pulverized coal combustion. A waste heat recovery technology (termed High Efficiency System) from Mitsubishi Heavy Industries America was integrated into an existing 25-MW amine-based CO 2 capture process (Kansai Mitsubishi Carbon Dioxide Recovery Process®1) at Southern Company’s Plant Barry to evaluate improvements in the energy performance of the pulverized coal plant and CO 2 capture process. The heat integration system consists of two primary pieces of equipment: (1) the CO 2 Cooler which uses product CO 2 gas from the capture process to heat boiler condensate, and (2) the Flue Gas Cooler which uses air heater outlet flue gas to further heat boiler condensate. Both pieces of equipment were included in the pilot system. The pilot CO 2 Cooler used waste heat from the 25-MW CO 2 capture plant (but not always from product CO 2 gas, as intended). The pilot Flue Gas Cooler used heat from a slipstream of flue gas taken from downstream of Plant Barry’s air heater. The pilot also included a 0.25-MW electrostatic precipitator. The 25-MW High Efficiency System operated for approximately six weeks over a four month time period in conjunction with the 25-MW CO 2 capture facility at Plant Barry. Results from the program were used to evaluate the technical and economic feasibility of full-scale implementation of this technology. The test program quantified energy efficiency improvements to a host power plant that could be realized due to the High Efficiency System. Through the execution of this project, the team verified the integrated operation of the High Efficiency System and Kansai Mitsubishi Carbon Dioxide Recovery Process®. The ancillary benefits of the High Efficiency System were also quantified, including reduced water consumption, a decrease in toxic air emissions, and better overall air quality control systems performance.

20 FOSSIL-FUELED POWER PLANTS↗

Effect of H{sub 2}O on the desulfurization of simulated flue gas by an ionic liquid

Functionalized ionic liquids (ILs) have been demonstrated to absorb SO{sub 2} from mixed gases or simulated flue gases efficiently. However, after absorbing a large amount of SO{sub 2}, the viscosity of the ILs increases greatly, which might limit their eventual applications in large-scale desulfurization from mixed gases or flue gases. In this work, the effect of the presence of water in a simulated flue gas on the absorption of SO{sub 2} by a functionalized ionic liquid, 1,1,3,3-tetramethylguanidinium lactate, has been studied at different temperatures. It is found that the presence of water in the simulated flue gas can decrease the viscosity of the IL greatly, and it has no effect on the absorptivity of SO{sub 2} from the flue gas. The densities of the IL absorbing SO{sub 2} from the flue gas with or without water are also studied. They increase with the increase of the amount of SO{sub 2} absorbed from the flue gas in both cases.

01 COAL, LIGNITE, AND PEAT↗

CO 2 Capture by Cold Membrane Operation with Actual Power Plant Flue Gas

The main objective of the project was to develop a post-combustion CO 2 capture process based on the hybrid cold temperature membrane operation. The CO 2 in the flue gas from coal fired power plant is pre-concentrated to >60% CO 2 in the first stage membrane operation followed by further liquefaction of permeate stream to achieve >99% CO 2 purity. The aim of the project was based on DOE program goal of 90% CO 2 capture with >95% CO 2 purity from Pulverized Coal (PC) fired power plants with $40/tonne of carbon capture cost by 2025. The project moves the technology from TRL 4 to TRL 5. The project involved optimization of Air Liquide commercial 12” PI-1 bundle to improve the bundle productivity by >30% compared to the previous baseline (DE-FE0004278) using computational fluid dynamics (CFD) modeling and bundle testing with synthetic flue gas at 0.1 MWe bench scale skid located at Delaware Research and Technology Center (DRTC). In parallel, the next generation polyimide based novel PI-2 membrane was developed with 10 times CO 2 permeance compared to the commercial PI-1 membrane. The novel PI-2 membrane was scaled from mini-permeator to 1” permeator and 1” bundle for testing. Bundle development was conducted with a Development Spin Unit (DSU) installed at MEDAL. Air Liquide’s cold membrane technology was demonstrated with real coal fired flue gas at the National Carbon Capture Center (NCCC) with a 0.3 MWe field-test unit (FTU). The FTU was designed to incorporate testing of two PI-1 commercial membrane bundles (12” or 6” diameter) in parallel or series. A slip stream was sent to the next generation PI-2 membrane for testing with real flue gas. The system exceeded performance targets with stable PI-1 membrane operation for over 500 hours of single bundle, steady state testing. The 12” PI-1 bundle exceeded the productivity target by achieving ~600 Nm3/hr, where the target was set at ~455 Nm3/hr at 90% capture rate. The cost of 90% CO 2 capture from a 550 MWe net coal power plant was estimated between 40 and $45/tonne. A 6” PI-1 bundle exhibited superior bundle performance compared to the 12” PI-1 bundle. However, the carbon capture cost was not lower with the 6” PI-1 bundle due to the higher bundle installed cost. A 1” PI-1 bundle was tested to compare bundles with different length / diameter ratios. This bundle exhibited the lowest performance due to the different fiber winding pattern and increased bundle non-ideality. Several long-term and parametric tests were conducted with 3,200 hours of total run-time at NCCC. Finally, the new PI-2 membrane fiber was tested at a small scale (1” modules) in real flue gas and exhibited up to 10 times the CO 2 permeance and slightly lower CO 2 /N 2 selectivity as the commercial PI-1 fiber. This corresponded to a projected 4 - 5 times increase in the productivity per bundle and a potential cost reduction of $3/tonne for CO2 capture, as compared with PI-1. An analytical campaign was conducted to trace different impurities such as NOx, mercury, Arsenic, Selenium in gas and liquid samples through the carbon capture system. An Environmental, Health and Safety (EH&S) analysis was completed to estimate emissions from a 550 MWe net power plant with carbon capture using cold membrane. A preliminary design and cost analysis was completed for 550 tpd (~25 MWe) plant to assess the capital investment and carbon capture cost for PI-1 and PI-2 membrane solutions from coal fired flue gas. A comparison was made with an amine based solution with significant cost advantage for the membrane at this scale. Additional preliminary design and cost analysis was completed between coal, natural gas and SMR flue gas for carbon capture at 550 tpd (~25 MWe) plant.

01 COAL, LIGNITE, AND PEAT↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flue gas adsorption by single-wall carbon nanotubes: A Monte Carlo study

Adsorption of flue gases by single-wall carbon nanotubes (SWCNT) has been studied by means of Monte Carlo simulations. The flue gas is modeled as a ternary mixture of N{sub 2}, CO{sub 2}, and O{sub 2}, emulating realistic compositions of the emissions from power plants. The adsorbed flue gas is in equilibrium with a bulk gas characterized by temperature T, pressure p, and mixture composition. We have considered different SWCNTs with different chiralities and diameters in a range between 7 and 20 Å. Our results show that the CO{sub 2} adsorption properties depend mainly on the bulk flue gas thermodynamic conditions and the SWCNT diameter. Narrow SWCNTs with diameter around 7 Å show high CO{sub 2} adsorption capacity and selectivity, but they decrease abruptly as the SWCNT diameter is increased. For wide SWCNT, CO{sub 2} adsorption capacity and selectivity, much smaller in value than for the narrow case, decrease mildly with the SWCNT diameter. In the intermediate range of SWCNT diameters, the CO{sub 2} adsorption properties may show a peculiar behavior, which depend strongly on the bulk flue gas conditions. Thus, for high bulk CO{sub 2} concentrations and low temperatures, the CO{sub 2} adsorption capacity remains high in a wide range of SWCNT diameters, although the corresponding selectivity is moderate. We correlate these findings with the microscopic structure of the adsorbed gas inside the SWCNTs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale modeling and nonlinear model predictive control for flue gas desulfurization

The primary source of sulfur dioxide (SO 2 ) emissions is flue gas from fossil fuels-based power plants. SO 2 emissions are known to not only cause health issues, but also have an adverse effect on the environment in various ways. Several Flue Gas Desulfurization (FGD) technologies have been incorporated in power plants. The most popular technology is Wet FGD, where a limestone slurry is used to absorb SO 2 from the flue gas. A detailed droplet scale model describing the instantaneous and finite rate chemistry is developed. The ill-posed Differential-Algebraic Equation (DAE) droplet model is reformulated to a well-posed index-1 DAE through index reduction. The droplet model is integrated with the bulk phase by incorporating gas-liquid mass transfer, and an oxidation reactor model to simulate the dynamic operation of the counter-current spray scrubber. As a result, the model has a well-conditioned Jacobian and overcomes the modeling challenges of previous works and enables numerical solution without requiring carefully selected initialization or specialized solution procedures. The model is successfully validated using power plant measurements, and nonlinear model predictive control (NMPC) studies are demonstrated to optimize recycle stream flowrates to minimize pumping costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potential Agricultural Uses of Flue Gas Desulfurization Gypsum in the Northern Great Plains

Flue gas desulfurization gypsum (FGDG) is a byproduct from the combustion of coal for electrical energy production. Currently, FGDG is being produced by 15 electrical generating stations in Alabama, Florida, Indiana, Iowa, Kentucky, Ohio, North Carolina, South Carolina, Tennessee, Texas, and Wisconsin. Much of this byproduct is used in the manufacturing of wallboard. The National Network for Use of FGDG in Agriculture was initiated to explore alternative uses of this byproduct. In the northern Great Plains (North Dakota, South Dakota, and Montana), FGDG has the potential to be used as a Ca or S fertilizer, as an acid soil ameliorant, and for reclaiming or mitigating sodium-affected soils. Greater than 1.4 million Mg of FGDG could initially be used in these states for these purposes. Flue gas desulfurization gypsum can be an agriculturally important resource for helping to increase the usefulness of problem soils and to increase crop and rangeland production. Conducting beneficial use audits would increase the public awareness of this product and help identify to coal combustion electrical generating stations the agriculturally beneficial outlets for this byproduct.

01 COAL, LIGNITE, AND PEAT↗

Effects of HCl and SO{sub 2} concentration on mercury removal by activated carbon sorbents in coal-derived flue gas

The effect of the presence of HCl and SO{sub 2} in the simulated coal combustion flue gas on the Hg{sup 0} removal by a commercial activated carbon (coconut shell AC) was investigated in a laboratory-scale fixed-bed reactor in a temperature range of 80-200{sup o}C. The characteristics (thermal stability) of the mercury species formed on the sorbents under various adsorption conditions were investigated by the temperature-programmed decomposition desorption (TPDD) technique. It was found that the presence of HCl and SO{sub 2} in the flue gas affected the mercury removal efficiency of the sorbents as well as the characteristics of the mercury adsorption species. The mercury removal rate of AC increased with the HCl concentration in the flue gas. In the presence of HCl and the absence of SO{sub 2} during Hg{sup 0} adsorption by AC, a single Hg{sup 0} desorption peak at around 300{sup o}C was observed in the TPDD spectra and intensity of this peak increased with the HCl concentration during mercury adsorption. The peak at around 300{sup o}C may be derived from the decomposition and desorption of mercury chloride species. The presence of SO{sub 2} during mercury adsorption had an adverse effect on the mercury removal by AC in the presence of HCl. In the presence of both HCl and SO{sub 2} during Hg{sup 0} adsorption by AC, the major TPDD peak temperatures changed drastically depending upon the concentration of HCl and SO{sub 2} in flue gas during Hg{sup 0} adsorption. 16 refs., 7 figs.

01 COAL, LIGNITE, AND PEAT↗

Near-Zero Emissions Oxy-Combustion Flue Gas Purification Task 2: SOx/Nox/Hg Removal for High Sulfur Coal

The goal of this project is to develop a near-zero emissions flue gas purification technology for existing PC (pulverized coal) power plants that are retrofitted with oxy-combustion technology. The objective of Task 2 of this project was to evaluate an alternative method of SOx, NOx and Hg removal from flue gas produced by burning high sulfur coal in oxy-combustion power plants. The goal of the program was not only to investigate a new method of flue gas purification but also to produce useful acid byproduct streams as an alternative to using a traditional FGD and SCR for flue gas processing. During the project two main constraints were identified that limit the ability of the process to achieve project goals. 1) Due to boiler island corrosion issues >60% of the sulfur must be removed in the boiler island with the use of an FGD. 2) A suitable method could not be found to remove NOx from the concentrated sulfuric acid product, which limits sale-ability of the acid, as well as the NOx removal efficiency of the process. Given the complexity and safety issues inherent in the cycle it is concluded that the acid product would not be directly saleable and, in this case, other flue gas purification schemes are better suited for SOx/NOx/Hg control when burning high sulfur coal, e.g. this project's Task 3 process or a traditional FGD and SCR.

01 COAL, LIGNITE, AND PEAT↗

Flue gas carbon dioxide sequestration during water softening with ion-exchange fibers

This study examines the use of ion-exchange fibers (IX fibers) to permanently sequester carbon dioxide present in flue gas into an aqueous phase as calcium or magnesium alkalinity while concurrently softening hard water. The only process inputs besides carbon dioxide (or flue gas) are snowmelt (or rainwater); no other chemicals are required for the regeneration of the IX fibers. Importantly, the process is not energy intensive and carbon dioxide does not need to be compressed to excessive pressures (>150 psi) for efficient use. Sources of carbon dioxide do not require concentration and, therefore, the use of raw flue gas (similar to 17% CO{sub 2}) is feasible with the rate of sequestration governed only by the partial pressure of carbon dioxide. While valid for flue gas obtained from any combustion process (e.g., coal, oil, natural gas, etc.), emissions from oil or gas combustion may be more appropriate for use in the described process due to the absence of mercury and particulates. It should also be noted that the presence of sulfur dioxide in flue gas would not adversely affect the process and may even enhance regeneration efficiency. The only product of the proposed process is an environmentally benign regenerant stream containing calcium and/or magnesium alkalinity. The unique property of IX fibers that makes the proposed process both environmentally sustainable and economically feasible is amenability to efficient regeneration with carbon dioxide and harvested snowmelt. Low intraparticle diffusional resistance is the underlying reason why IX fibers are amenable to efficient regeneration using snowmelt sparged with carbon dioxide; 95% calcium recovery was attained at a CO{sub 2} partial pressure of 6.8 atm. The energy balance for a typical electric utility shows that up to 1% of carbon dioxide emitted during combustion would be sequestered in the softening process.

01 COAL, LIGNITE, AND PEAT↗

Carbon Mineralization by Aqueous Precipitation for Beneficial Use of CO 2 from Flue Gas

The objective of this project was to demonstrate an innovative process to mineralize CO 2 from flue gas directly to reactive carbonates and maximize the value and versatility of its beneficial use products. The program scope includes the design, construction, and testing of a CO 2 Conversion to Material Products (CCMP) Pilot Demonstration Plant utilizing CO 2 from the flue gas of a power production facility in Moss Landing, CA as well as flue gas from coal combustion. This final report details all development, analysis, design and testing of the project. Also included in the final report are an updated Techno-Economic Analysis and CO 2 Lifecycle Analysis. The subsystems included in the pilot demonstration plant are the mineralization subsystem, the Alkalinity Based on Low Energy (ABLE) subsystem, the waste calcium oxide processing subsystem, and the fiber cement board production subsystem. The fully integrated plant was proven to be capable of capturing CO 2 from various sources (gas and coal) and mineralizing it into a reactive calcium carbonate binder and subsequently producing commercial size (4ftx8ft) fiber cement boards. The final report provides a description of the “as built” design of these subsystems and the results of the commissioning activities that have taken place to confirm operability. The report also discusses the results of the fully integrated operation of the facility. Fiber cement boards have been produced in this facility exclusively using reactive calcium carbonate from captured CO 2 from flue gas. These boards meet all US and China appropriate acceptance standards. Use demonstrations for these boards are now underway.

20 FOSSIL-FUELED POWER PLANTS↗

Microalgae Commodities from Coal-Fired Power Plant Flue Gas CO 2 (Draft Final Report, October 1, 2015 to June 30, 2018)

The Orlando Utilities Commission (OUC) operates an approximately 900-MWe coal fired-power plant at Stanton Energy Center (SEC), which was the site for this project to develop an integrated process for microalgae utilization of flue gas CO 2 for the production of biofuels and animal feeds. Microalgae have both potentially high yields (tons biomass/acre-year) and can be used for biofuels or high value animal feeds. The high biomass yields of microalgae cultures allows efficient use of land and water resources. They can also use wastewaters, recycle fertilizers, and have lower overall greenhouse gas emissions than conventional biofuels or animal feeds. However, many technical issues and technology gaps related to large-scale algae biomass production still must be resolved before such a process can be scaled-up. In this project, techno-economic analyses (TEAs) and life cycle assessments (LCAs) were carried out, projecting the costs and impacts of large-scale algae biomass cultivation for production of biofuels and animal feeds using OUC-SEC flue gas CO 2 . In addition, 3.5-m 2 (~ 40-ft 2 ) experimental raceway ponds were used for the cultivation of microalgae at OUC-SEC and also at the University of Florida. A large-scale algae farm was designed for a 1,300-acre site (~500-ha) located near the OUC-SEC plant, consisting of 400 hectares (1,000 acres) of paddle wheel mixed raceway ponds (each 4 ha), receiving flue gas piped approximately 3 km (2 miles) from the SEC plant. In the first year of this project (Budget Period 1, BP1), the TEA and LCA studies focused on the production of biogas produced from algae biomass and its use to replace coal at the power plant. However, due to the resulting very high cost of CO 2 mitigation, the process was modified to produce compressed natural gas (‘renewable natural gas’, RNG) for transportation fuel from the biogas, in conjunction with wastewater treatment by the algae cultures. During Budget Period 2 (BP2), the TEA and LCA studies focused on the production of animal feeds by the algae farm, using fresh water and agricultural fertilizers. In this case, CO 2 mitigation costs would be entirely covered if the algal biomass could be sold at between a two to three-fold premium above soybean feed, based on a higher nutritional value for the algal biomass. In support of the above analyses, microalgae cultivation experiments were carried out for over two years during this project in small 3.5-m 2 ponds at both SEC and the University of Florida. The most important results were the demonstration at SEC of the cultivation, on flue gas CO 2 , of filamentous algae biomass, which can be harvested at much lower cost than processes required for the colloidal algae species, as currently used by almost all algal mass culture biofuels and animal feeds projects. The yield of biogas production from the algal biomass was investigated by the University of Florida, and the value of the algal biomass as animal feed was projected based on biochemical analysis of the SEC ad UF biomasses. The conclusion from TEA/LCA carried out for the biogas case in BP1 was that a 400-ha algae system producing biomethane for co-firing at OUC-SEC could generate 27,500 MWh/yr of renewable power, offsetting 28,400 Mg CO 2eq /yr, which amounted to less than 1% of the CO 2 emitted by the SEC plant. (Mg = metric ton = 1.10 short tons). The overall cost was projected at $820/Mg of CO 2eq reduction, making this process unfeasible under any possible scenario. More favorable economics were projected when the biogas was converted to higher value transportation fuel, RNG, which also would benefit from renewable fuel (RINs) and possibly other credits. However, only by combining RNG production with municipal wastewater treatment in the algal ponds would CO 2 utilization result in no net cost or even be economically beneficial (i.e., generate income to the power plant). However, in that case the amount of CO 2 utilization would be even lower than that in the biogas case, because a large fraction of the carbon required would be supplied from the wastewater and CO 2 recovered during biogas upgrading to RNG. In brief, use of power plant CO 2 emissions for algal biofuels production was not favorable, even with optimistic assumptions about biomass productivity and biogas yields. For the animal feed case, developed during BP2, algal biomass would replace soybean feeds. The same scale 400-ha algal production plant was projected to produce 26,280 Mg per year of animal feed with a utilization of 45,300 Mg flue gas CO 2 taken up by the algal biomass. However, the process would result in a projected reduction of 112,500 Mg CO 2eq emissions per year, or roughly 1.9% of OUC-SEC emissions, mainly due to the large CO 2eq emissions from conventional soybean production. A major factor in this analysis were greenhouse gas emissions from land use changes. The cost of CO 2 utilization was projected at $116/Mg if the biomass sold for the same price as soybean meal, but if sold as a premium feed (e.g., based on high omega-3 fatty acid and carotenoid content), the power plant could actually charge for the CO 2 utilized. These economic projections are sensitive to assumptions underlying the TEA and LCA models, including biomass composition and the financial models used to project CAPEX and OPEX. Further development of an algal animal feed production using coal-fired power plant flue gas CO 2 is recommended based on the TEA and LCA, as well as experimental results. The required research and development is detailed in a technology gap analysis (Section 11), which focuses on the demonstrations of the cultivation of higher value filamentous algal biomass at OUC-SEC.

01 COAL, LIGNITE, AND PEAT↗

MEMBRANE PROCESS TO SEQUESTER CO2 FROM POWER PLANT FLUE GAS

The objective of this project was to assess the feasibility of using a membrane process to capture CO2 from coal-fired power plant flue gas. During this program, MTR developed a novel membrane (Polaris™) with a CO2 permeance tenfold higher than commercial CO2-selective membranes used in natural gas treatment. The Polaris™ membrane, combined with a process design that uses a portion of combustion air as a sweep stream to generate driving force for CO2 permeation, meets DOE post-combustion CO2 capture targets. Initial studies indicate a CO2 separation and liquefaction cost of $20 - $30/ton CO2 using about 15% of the plant energy at 90% CO2 capture from a coal-fired power plant. Production of the Polaris™ CO2 capture membrane was scaled up with MTR’s commercial casting and coating equipment. Parametric tests of cross-flow and countercurrent/sweep modules prepared from this membrane confirm their near-ideal performance under expected flue gas operating conditions. Commercial-scale, 8-inch diameter modules also show stable performance in field tests treating raw natural gas. These findings suggest that membranes are a viable option for flue gas CO2 capture. The next step will be to conduct a field demonstration treating a realworld power plant flue gas stream. The first such MTR field test will capture 1 ton CO2/day at Arizona Public Service’s Cholla coal-fired power plant, as part of a new DOE NETL funded program.

03 NATURAL GAS↗

Explaining the differential solubility of flue gas components in ionic liquids from first-principle calculations

Flue gas is greatly responsible for acid rain formation and global warming. New generation ionic liquids (ILs) have potential in controlling the flue gas emissions, as they acquire high absorptivity for the component gases SO{sub 2}, CO{sub 2}, etc. The association of the IL-gas interactions to the absorptivity of gas molecules in ILs is, however, poorly understood. In this paper, we present a molecular level description of the interactions of ILs with SO{sub 2}, CO{sub 2}, and N{sub 2} and show its implications to the differential gas solubility. Our results indicate that the IL anion-gas interactions play a key role in deciding the gas solubility in ILs, particularly for polar gases such as SO{sub 2}. On the other hand, regular solution assumption applies to -2 solubility. In accordance with the previous theoretical and experimental findings, our results also imply that the IL anions dominate the interactions with gas molecules while the cations play a secondary role and the underlying fluid structures of the ILs remain unperturbed by the addition of gas molecules.

01 COAL, LIGNITE, AND PEAT↗

Partitioning of mercury, arsenic, selenium, boron, and chloride in a full-scale coal combustion process equipped with selective catalytic reduction, electrostatic precipitation, and flue gas desulfurization systems

A full-scale field study was carried out at a 795 MWe coal-fired power plant equipped with selective catalytic reduction (SCR), an electrostatic precipitator (ESP), and wet flue gas desulfurization (FGD) systems to investigate the distribution of selected trace elements (i.e., mercury, arsenic, selenium, boron, and chloride) from coal, FGD reagent slurry, makeup water to flue gas, solid byproduct, and wastewater streams. Flue gases were collected from the SCR outlet, ESP inlet, FGD inlet, and stack. Concurrent with flue gas sampling, coal, bottom ash, economizer ash, and samples from the FGD process were also collected for elemental analysis. By combining plant operation parameters, the overall material balances of selected elements were established. The removal efficiencies of As, Se, Hg, and B by the ESP unit were 88, 56, 17, and 8%, respectively. Only about 2.5% of Cl was condensed and removed from flue gas by fly ash. The FGD process removed over 90% of Cl, 77% of B, 76% of Hg, 30% of Se, and 5% of As. About 90% and 99% of the FGD-removed Hg and Se were associated with gypsum. For B and Cl, over 99% were discharged from the coal combustion process with the wastewater. Mineral trona (trisodium hydrogendicarbonate dehydrate, Na{sub 3}H(CO{sub 3}){sub 2}.2H{sub 2}O) was injected before the ESP unit to control the emission of sulfur trioxide (SO{sub 3}). By comparing the trace elements compositions in the fly ash samples collected from the locations before and after the trona injection, the injection of trona did not show an observable effect on the partitioning behaviors of selenium and arsenic, but it significantly increased the adsorption of mercury onto fly ash. The stack emissions of mercury, boron, selenium, and chloride were for the most part in the gas phase. 47 refs., 3 figs., 11 tabs.