Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLIM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Strain-Modulated Exciton Localization and Enhanced Emission in Multilayer GaSe

Strain engineering is one of the most effective routes for tuning the electrical and optical properties of two-dimensional layered materials. Besides reproducing the results of other groups on the tunability and photoluminescence (PL) enhancement of free and bound excitons under mechanical deformation or thermal effects, we systematically studied the mechanical strain (wrinkle) and local thermal strain (laser heating) effects on the PL lifetime and polarization in GaSe multilayers and their interplay, revealing their coupled impact on excitonic dynamics. Here, the PL intensity of localized excitons in the wrinkle region of GaSe increases superlinearly with the excitation laser power. The polarization effect has been observed for the bound exciton in GaSe under mechanical strain, but not in GaSe under thermal strain. Fluorescence lifetime imaging (FLIM) measurements reveal strain-tunable lifetimes for both free and bound excitons, and the lifetime of the bound exciton is longer than the free exciton in the mechanical strain region, correlating with the enhanced emission of the bound exciton. These results highlight previously uncharacterized optoelectronic tunability in GaSe and broaden the design space for strain (or thermally)-controlled 2D layered devices.

, GaSe, Exciton localization↗

Thermal-Strain-Enabled Enhanced Emission from UV Laser-Induced Defect Levels near the Surface of Multilayer MoS 2

Monolayer two-dimensional (2D) materials have been intensively studied while research on multilayers is still in its infancy. Here, we induce defects inside bulk MoS 2 through thermal annealing and near the surface of multilayer MoS 2 using 375 nm laser irradiation, and investigate their photoluminescence (PL) and fluorescence lifetime imaging (FLIM). Enhanced emission is limited within a certain MoS 2 thickness. The observed enhanced emission is evidenced by a threshold behavior in super-linear PL intensity increase, strong polarization effects, and increased lifetime of defect peak. The laser power threshold for enhanced emission is much smaller in defects near the surface than that inside the bulk of multilayer MoS 2 . The mechanical strain from a wrinkle of the sample further lowers the laser power threshold for enhanced emission. By exciting with a 639 nm laser that is close to the fundamental gap between the conduction band minimum and the valence band maximum, the lifetime of defect enhanced emission increased by 5 times. Furthermore, one of the competing indirect bandgap emissions disappears, and the defect emission peak dominates the PL spectrum in the wrinkle area with a strain. Furthermore, the discovered principle can be applied to future studies on the integration of enhanced emission and single photon emission involving selectively depopulating the conduction band of the host crystal to defect levels for quantum emitters.

2D materials↗

CASPI: collaborative photon processing for active single-photon imaging

Image sensors capable of capturing individual photons have made tremendous progress in recent years. However, this technology faces a major limitation. Because they capture scene information at the individual photon level, the raw data is sparse and noisy. Here we propose CASPI: Collaborative Photon Processing for Active Single-Photon Imaging, a technology-agnostic, application-agnostic, and training-free photon processing pipeline for emerging high-resolution single-photon cameras. By collaboratively exploiting both local and non-local correlations in the spatio-temporal photon data cubes, CASPI estimates scene properties reliably even under very challenging lighting conditions. We demonstrate the versatility of CASPI with two applications: LiDAR imaging over a wide range of photon flux levels, from a sub-photon to high ambient regimes, and live-cell autofluorescence FLIM in low photon count regimes. We envision CASPI as a basic building block of general-purpose photon processing units that will be implemented on-chip in future single-photon cameras.

47 OTHER INSTRUMENTATION↗

A modular chemigenetic calcium indicator for multiplexed in vivo functional imaging

Abstract Genetically encoded fluorescent calcium indicators allow cellular-resolution recording of physiology. However, bright, genetically targetable indicators that can be multiplexed with existing tools in vivo are needed for simultaneous imaging of multiple signals. Here we describe WHaloCaMP, a modular chemigenetic calcium indicator built from bright dye-ligands and protein sensor domains. Fluorescence change in WHaloCaMP results from reversible quenching of the bound dye via a strategically placed tryptophan. WHaloCaMP is compatible with rhodamine dye-ligands that fluoresce from green to near-infrared, including several that efficiently label the brain in animals. When bound to a near-infrared dye-ligand, WHaloCaMP shows a 7× increase in fluorescence intensity and a 2.1-ns increase in fluorescence lifetime upon calcium binding. We use WHaloCaMP1a to image Ca 2+ responses in vivo in flies and mice, to perform three-color multiplexed functional imaging of hundreds of neurons and astrocytes in zebrafish larvae and to quantify Ca 2+ concentration using fluorescence lifetime imaging microscopy (FLIM).

Biochemistry & Molecular Biology↗

WE-FG-BRA-03: Oxygen Interplay in Hypofractionated Radiotherapy: A Hidden Opportunity

Purpose: Local oxygen during a radiotherapy fraction has been shown to change over a full range of the oxygen enhancement ratio (OER) during the same time scale as the treatment fraction. Interplay with local oxygen is then likely a concern, especially for hypofractionation. Our experiments that show a strong role for metabolic dynamics suggesting one could manipulate this interplay for more efficacious treatments. Methods: Two published experiments are presented with the same human head and neck cancer cell line (UM-SCC-22B). One is a cell-specific in vitro prompt response to a 10 Gy dose of orthovotage radiation using fluorescence lifetime imaging (FLIM), benchmarked with a Seahorse assay. The other in vivo study uses autocorrelation analysis with blood oxygen level dependent magnetic resonance imaging (MRI-BOLD) on xenografts. In vivo results are verified with diffuse optics using spectra fitting and photoacoustic measurements. All these measurements are at high time resolution: sampling is one per minute. Results: Interplay happens when the radiosensitivity modulates at the same time scale as the radiation. These results show dynamics at these time scales. 1. The dominant time scale of the acute hypoxia in cell line xenografts is shown to be on the order of minutes to tens of minutes: similar to a metabolic oscillation known as the ‘glycolytic oscillator.’ 2. The radiation dose itself alters metabolism within minutes to tens of minutes also. Conclusion: These results vary with cell type. There is a possibility that special timing and dose levels could be used for radiation. Gating could be used for maximal oxygen during treatment. There is an analogy to the interplay discussions with tumor motion, except that an oxygen interplay could more likely be patient-specific at a more fundamental level.

60 APPLIED LIFE SCIENCES↗

In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo . Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

47 OTHER INSTRUMENTATION↗

Surface-Enhanced Raman Imaging of Intracellular Bioreduction of Chromate in Shewanella oneidensis

This proposed research aims to use novel nanoparticle sensors and spectroscopic tools constituting surface-enhanced Raman spectroscopy (SERS) and Fluorescence Lifetime imaging (FLIM) to study intracellular chemical activities within single bioremediating microorganism. The grand challenge is to develop a mechanistic understanding of chromate reduction and localization by the remediating bacterium Shewanella oneidensis MR-1 by chemical and lifetime imaging. MR-1 has attracted wide interest from the research community because of its potential in reducing multiple chemical and metallic electron acceptors. While several biomolecular approaches to decode microbial reduction mechanisms exist, there is a considerable gap in the availability of sensor platforms to advance research from population-based studies to the single cell level. This study is one of the first attempts to incorporate SERS imaging to address this gap. First, we demonstrate that chromate-decorated nanoparticles can be taken up by cells using TEM and Fluorescence Lifetime imaging to confirm the internalization of gold nanoprobes. Second, we demonstrate the utility of a Raman chemical imaging platform to monitor chromate reduction and localization within single cells. Distinctive differences in Raman signatures of Cr(VI) and Cr(III) enabled their spatial identification within single cells from the Raman images. A comprehensive evaluation of toxicity and cellular interference experiments conducted revealed the inert nature of these probes and that they are non-toxic. Our results strongly suggest the existence of internal reductive machinery and that reduction occurs at specific sites within cells instead of at disperse reductive sites throughout the cell as previously reported. While chromate-decorated gold nanosensors used in this study provide an improved means for the tracking of specific chromate interactions within the cell and on the cell surface, we expect our single cell imaging tools to be extended to monitor the interaction of other toxic metal species.

59 BASIC BIOLOGICAL SCIENCES↗

Inorganic voltage nanosensors for bioelectricity studies in bacterial communities

We developed both membrane potential nanosensors (MPNs) and voltage sensing dyes (VSDs), and quantitative optical measurement tools to measure membrane potential (MP) at the level of a single bacterial cell, with voltage resolution of ~10 mV changes. Our approach relied on (i) novel MPNs and novel VSDs that measures MPs via fluorescence lifetime; (ii) a quantitative approach to fluorescence lifetime imaging microscopy (FLIM) data based on a novel time-resolved camera and phasor analysis. We demonstrate MP measurements over time for single bacterial cells.

59 BASIC BIOLOGICAL SCIENCES↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Chemical vapor deposited silica coatings for solar mirror protection

A variety of techniques is available to apply protective coatings to oxidation susceptible spacecraft components, and each has associated advantages and disadvantages. Film applications by means of chemical vapor deposition (CVD) has the advantage of being able to be applied conformally to objects of irregular shape. For this reason, a study was made of the oxygen plasma durability of thin film (less than 5000 A) silicon dioxide coatings applied by CVD. In these experiments, such coatings were applied to silver mirrors, which are strongly subject to oxidation, and which are proposed for use on the space station solar dynamic power system. Results indicate that such coatings can provide adequate protection without affecting the reflectance of the mirror. Scanning electron micrographs indicated that oxidation of the silver layer did occur at stress crack locations, but this did not affect the measured solar reflectances. Oxidation of the silver did not proceed beyond the immediate location of the crack. Such stress cracks did not occur in thinner silica flims, and hence such films would be desirable for this application.

Gulino, Daniel A.↗

Analysis of surfaces from the LDEF A0114, phase 4

Progress made from 1 Mar. to 31 Aug. 1991 is presented. The work concentrated on profilometry measurements of eroded and corroded sample surfaces, optical transmission measurements, analysis of the pinhole camera, and x-ray photoelectron spectroscopic (XPS) analysis of some samples. The following papers are presented: (1) observation of Be-7 on the surface of the Long Duration Exposure Facility (LDEF) Spacecraft; (2) measurement of the passive attitude control performance of a recovered spacecraft; (3) effects on LDEF exposed copper flim and bulk; (4) measurements of erosion characteristics for metal and polymer surfaces using profilometry; (5) the interactions of atmospheric cosmogenic radionuclides with spacecraft surfaces; (6) pinhole cameras as sensors for atomic oxygen in orbit; and (7) interaction of atomic oxygen with solid surfaces in low earth orbit- results from LDEF experiment A0114.

Gregory, John C.↗

Advanced Laser Processing of Materials--Fundamentals and Applications

Preparation of amorphous thin films in semiconductors and their transition to the crystalline phase may apply to switching devices. Surfaces of single crystal samples of bulk In2Se3 and thin films of InSe were treated using an excimer laser, and microscopic examination showed the treated portions of the surface had become amorphous. Film samples of InSe were laser-treated like the bulk samples. Examination of these treated flims showed shifts in the optical transmittance spectra as well as surface morphology changes.

amorphous thin films semiconductors crystalline ph↗

Bacterial signaling and motility: Sure bets

The IX International Conference on Bacterial Locomotion and Signal Transduction (BLAST IX) was held from 14 to 19 January 2007 in Laughlin, NV, a town in the Mojave Desert on the Nevada-Arizona border near old Route 66 and along the banks of the Colorado River. This area is a home to rattlesnakes, sagebrush, abandoned gold mines, and compulsive gamblers. What better venue could scientists possibly dream of for a professional meeting? So there they were, about 190 scientists gathered in the Aquarius Casino Resort, the largest hotel and casino in Laughlin, discussing the latest advances in the field. Aside from a brief excursion to an abandoned gold mine and a dinner cruise on the Colorado River, the scientists focused on nothing but their data and hypotheses, in spirited arguments and rebuttals, and outlined their visions and future plans in a friendly and open environment. The BLAST IX program was dense, with nearly 50 talks and over 90 posters. For that reason, this meeting report will not attempt to be comprehensive; instead it will first provide general background information on the central topics of the meeting and then highlight only a few talks that were of special interest to us and hopefully to the wider scientific community. We will also attempt to articulate some of the future directions or perspectives to the best of our abilities. The best known and understood bacterial motility mechanism is swimming powered by flagella. The rotation of bacterial flagella drives this form of bacterial movement in an aqueous environment. A bacterial flagellum consists of a helical filament attached to the cell body through a complex structure known as the hook-basal body, which drives flagellar rotation. The essential components of the basal body are the MotA-MotB motor-stator proteins bound to the cytoplasmic membrane. These stator proteins interact with proteins that comprise the supramembrane and cytoplasmic rings, which are components of the motor imbedded in the cytoplasmic membrane. The interaction causes the supramembrane and cytoplasmic rings to rotate along with the flagellar filaments. The energy for flagellar rotation comes from proton motive force or other ions, especially sodium in marine bacteria, which generate an electrochemical gradient across the cell membrane. Three proteins, FliM, FliN, and FliG, located at the base of the motor act as switches that control the direction of flagellar rotation. As exemplified by the enteric bacteria Escherichia coli and Salmonella enterica serovar Typhimurium, changes in the direction of flagellar rotation affect the swimming behavior of the bacterial cell. Counterclockwise (CCW) rotation of the flagella causes the flagellar filaments to form a bundle that pushes the cell forward in a 'run.' In contrast, clockwise (CW) rotation causes the flagellar bundle to fly apart, and the cell tumbles to reorient to a new direction for the ensuing run upon the return of CCW rotation. The interchanging pattern of CCW and CW rotations produces a random walk, composed of relatively long runs with occasional direction changes or turns. By modulating the lengths of the runs or the frequency of tumbling, bacteria can regulate their motile behavior to move in a desirable direction. Many bacteria can also move on surfaces. Except for flagellum-driven swarming motility, all the other forms of known bacterial surface movement involve no flagella. The flagellum-independent surface motility, known as gliding, is observed in cyanobacteria, Mycoplasma species, Cytophaga-Flexibacterium species, and Myxococcus species. Without a doubt, the most thoroughly studied model gliding bacterium is Myxococcus xanthus, which also serves as a prokaryotic model for developmental biology due to its ability to develop multicellular fruiting bodies. M. xanthus cells use gliding motility both to hunt for food during vegetative growth and to aggregate during fruiting body formation. When nutrients are present, groups of cells or swarms propagate and move outward like hunting wolf packs in search of additional macromolecules or prey. Upon starvation, cells aggregate at discrete foci to form mounds and then macroscopic fruiting bodies, each with hundreds of thousands of cells. The rod-shaped cells in the fruiting bodies eventually morph into spherical spores that are metabolically inactive and partially resistant to desiccation and temperature. When nutrients become available, spores can germinate and reenter the vegetative cell cycle. Two talks highlighted in this meeting review will tackle the mysteries of the gliding motility of M. xanthus in greater detail. In addition to M. xanthus, Caulobacter crescentus has extensively been investigated as a bacterial model of cell differentiation and development.

59 BASIC BIOLOGICAL SCIENCES↗

A General Autofluorescence Method to Characterize Polymerization Progress

An autofluorescence technique to characterize polymerization progress in real time/in line was developed, which functioned in the absence of typical fluorogenic groups on the monomer or polymer. The monomer dicyclopentadiene and polymer polydicyclopentadiene are hydrocarbons that lack traditional functional groups for fluorescence spectroscopy. Here, the autofluorescence of formulations containing this monomer and polymer during ruthenium-catalyzed ring-opening metathesis polymerization (ROMP) was harnessed for reaction monitoring. The methods fluorescence recovery after photobleaching (FRAP) and here-developed fluorescence lifetime recovery after photobleaching (FLRAP) characterized polymerization progress in these native systems—without requiring exogenous fluorophore. (Auto)fluorescence lifetime recovery changes during polymerization correlated linearly to degree of cure, providing a quantitative link with reaction progress. These changing signals also provided relative rates of background polymerization, enabling comparison of 10 different catalyst–inhibitor-stabilized formulations. Multiple-well analysis demonstrated suitability for future high-throughput evaluation of formulations for thermosets. Furthermore, the central concept of the combined autofluorescence and FLRAP/FRAP method may be extendable to monitoring other polymerization reactions previously overlooked for lack of an obvious fluorescence handle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited state lifetime modulation in semiconductor nanocrystals for super-resolution imaging

Abstract We report on proof of principle measurements of a concept for a super-resolution imaging method that is based on excitation field density-dependent lifetime modulation of semiconductor nanocrystals. The prerequisite of the technique is access to semiconductor nanocrystals with emission lifetimes that depend on the excitation intensity. Experimentally, the method requires a confocal microscope with fluorescence-lifetime measurement capability that makes it easily accessible to a broad optical imaging community. We demonstrate with single particle imaging that the method allows one to achieve a spatial resolution of the order of several tens of nanometers at moderate fluorescence excitation intensity.

36 MATERIALS SCIENCE↗

Fabrication and radio frequency test of large-area MgB 2 films on niobium substrates

Magnesium diboride (MgB 2 ) is a promising candidate material for superconducting radio frequency (RF) cavities because of its higher transition temperature and critical field compared with niobium. To meet the demand of RF test devices, the fabrication of large-area MgB 2 films on metal substrates is needed. Here, in this work, high quality MgB 2 films with 50 mm diameter were fabricated on niobium by using an improved HPCVD system at Peking University, and RF tests were carried out at SLAC National Accelerator Laboratory. The transition temperature is approximately 39.6 K and the RF surface resistance is about 120 μΩ at 4 K and 11.4 GHz. Finally, the fabrication processes, surface morphology, DC superconducting properties and RF tests of these large-area MgB 2 films are presented.

36 MATERIALS SCIENCE↗

An overview of continuous and discrete phasor analysis of binned or time-gated periodic decays

Time-resolved analysis of periodically excited luminescence decays by the phasor method in the presence of time gating or binning is revisited. Analytical expressions for discrete configurations of square gates are derived and the locus of the phasors of such modified periodic single-exponential decays is compared to the canonical universal semicircle. The effects of IRF offset, decay truncation and gate shape are also discussed. Finally, modified expressions for the phase and modulus lifetimes are provided for some simple cases. A discussion of a modified phasor calibration approach is presented.

42 ENGINEERING↗