Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Flexing the Limits of Land-Based Wind Turbine Rotor Growth

The Big Adaptive Rotor (BAR) project aims to design and enable the next generation of land-based wind turbines with 206-meter (m) rotors, which will increase capacity factors by 10% or more over a typical land-based turbine. High-energy-capture turbines have many advantages, but the length and width of larger turbine blades to enable these machines creates transportation challenges that must be overcome to make true on the adage, bigger is better.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Flexing the Limits of Land-Based Wind Turbine Rotor Growth

The Big Adaptive Rotor (BAR) project works to design and enable the next generation of land-based wind turbines with rotors that stretch 206 meters (m) in diameter, which will increase capacity factors by 10% or more over a typical land-based turbine. These high-energy-capture turbines have lower specific-power ratings, meaning they have larger rotors relative to the size of their generator, which helps them capture more wind and perform better at lower wind speeds, thereby increasing the turbine capacity factor. High-energy-capture turbines with larger rotors have many advantages, but the length and width of their blades creates transportation challenges that must be overcome to make true on the adage, bigger is better.

wind, big, adaptive, rotor↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Flex Charging Case Study

FlexCharging innovates at the intersection of EVs and the Electrical Grid, helping to accelerate EV adoption while reducing their impact on the electrical grid and the environment.

Grunkemeyer, Brian↗

Methodology and Application of Physical Security Effectiveness Based on Dynamic Force-on-Force Modeling

This report describes the research and development being performed at INL towards a dynamic modeling and simulation framework to enable physical security optimization at commercial nuclear power plants. The framework is based on the dynamic modeling tool EMRALD and is demonstrated for applications that can result in physical security optimization. Two main applications are presented: 1. Integrating FLEX portable equipment performance with FOF models of a plant’s physical security posture, and 2. Location optimization of bullet resistant enclosure. The generic framework for modeling FLEX portable equipment is described in detail, followed by a case study modeling an adversarial attack aimed at causing a radiological release by sabotaging the plant’s power supply and its ultimate heat sink capabilities at a hypothetical PWR. Two distinct FLEX deployment strategies, series and parallel, are modeled with distinct timelines. The results of the adversarial attack modeled in a commercial FOF tool, AVERT, are integrated with the FLEX deployment model in EMRALD. Monte Carlo simulation is used to model the distribution of the timeline in FLEX deployment strategies. Thermal-hydraulic analysis of FLEX performance is performed in RELAP5 and integrated with the EMRALD simulations to provide more realistic timelines in the models. The results demonstrate that, even in the extreme case of a successful adversarial attack, deployment of FLEX equipment can result in a significantly high likelihood of preventing radiological release. The modeling and simulation framework of integrating FLEX equipment with FOF models enables the NPPs to credit FLEX portable equipment in the plant security posture, resulting in an efficient and optimized physical security. The objective of location optimization of BRE is to determine the best location in the plant for a new BRE being planned by the plant to enhance their physical security effectiveness. The plant physical security FOF model is integrated with EMRALD that performs Monte Carlo simulation to run different attack scenarios and a discrete set of potential BRE locations. Sensitivity analysis is used to determine the most effective location for the BRE. The optimization approach can be extended to wide applications such as location optimization of remotely operated weapons and other strategic fixed assets.

97 MATHEMATICS AND COMPUTING↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Flexible silicon photonic architecture for accelerating distributed deep learning

The increasing size and complexity of deep learning (DL) models have led to the wide adoption of distributed training methods in datacenters (DCs) and high-performance computing (HPC) systems. However, communication among distributed computing units (CUs) has emerged as a major bottleneck in the training process. In this study, we propose Flex-SiPAC, a flexible silicon photonic accelerated compute cluster designed to accelerate multi-tenant distributed DL training workloads. Flex-SiPAC takes a co-design approach that combines a silicon photonic hardware platform with a tailored collective algorithm, optimized to leverage the unique physical properties of the architecture. The hardware platform integrates a novel wavelength-reconfigurable transceiver design and a micro-resonator-based wavelength-reconfigurable switch, enabling the system to achieve flexible bandwidth steering in the wavelength domain. The collective algorithm is designed to support reconfigurable topologies, enabling efficient all-reduce communications that are commonly used in DL training. The feasibility of the Flex-SiPAC architecture is demonstrated through two testbed experiments. First, an optical testbed experiment demonstrates the flexible routing of wavelengths by shuffling an array of input wavelengths using a custom-designed spatial-wavelength selective switch. Second, a four-GPU testbed running two DL workloads shows a 23% improvement in job completion time compared to a similarly sized leaf-spine topology. We further evaluate Flex-SiPAC using large-scale simulations, which show that Flex-SiPAC is able to reduce the communication time by 26% to 29% compared to state-of-the-art compute clusters under representative collective operations.

Wu, Zhenguo (ORCID:0000000322847985)↗

A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide

There is an urgent need for disinfection and sterilization devices accessible to the public that can be fulfilled by innovative strategies for using cold atmospheric pressure plasmas. Here, we demonstrate a successful novel combination of a flexible printed circuit design of a dielectric barrier discharge (flex-DBD) with an environmentally safe chemical reagent for surface decontamination from bacterial contaminants. Flex-DBD operates in ambient air, atmospheric pressure, and room temperature without any additional gas flow at a power density not exceeding 0.5 W/cm 2 . The flex-DBD activation of a 3% hydrogen peroxide solution results in the reduction in the bacterial load of a surface contaminant of > 6log 10 in 90 s, about 3log 10 and 2log 10 better than hydrogen peroxide alone or the flex-DBD alone, respectively, for the same treatment time. We propose that the synergy between plasma and hydrogen peroxide is based on the combined action of plasma-generated OH · radicals in the hydrogen peroxide solution and the reactive nitrogen species supplied by the plasma effluent. A scavenger method verified a significant increase in OH · concentration due to plasma treatment. Novel in-situ FTIR absorption spectra show the presence of O 3 , NO 2 , N 2 O, and other nitrogen species. Ozone dissolving in the H 2 O 2 solution can effectively generate OH · through a peroxone process. The addition of the reactive nitrogen species increases the disinfection efficiency of the hydroxyl radicals and other oxygen species. Hence, plasma activation of a low concentration hydrogen peroxide solution, using a hand-held flexible DBD device results in a dramatic improvement in disinfection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Damage Detection and Electrical Performance Impact of Flat-Flexible Circuits

Flat-flexible circuits or ‘flex circuits’ have varied applications in electronics and in explosive detonation systems. They pose advantages over conventional coaxial cables in their ability to fit into small mechanical envelopes and routings. A typical flex circuit is composed of a laminated assembly of multiple layers of conductor and dielectric materials. Copper, because of its high electrical conductivity, is one of the primary materials used in flex circuit conductors. The conductor must maintain structural integrity and electrical continuity when the flexible circuit is bent during processing or to fit an application envelope. Under some strain conditions a cable may have degraded electrical performance even though visible damage may not be evident. Dislocation density can increase by mechanisms such as dislocation forest hardening, where gliding dislocations in primary slip planes get pinned at obstacles and form Frank-Read sources. Dislocation density increases within the conductor layers may impact electrical resistivity but would not necessarily result in visible mechanical failure. In some detonation applications, such as for building implosion for demolition, the time for signal transmission and voltage used for firing detonators can be critical. If the resistance in a single flex cable within a building demolition array is too high, the resultant demolition shape may be asymmetric, leading to unplanned damage to nearby structures and potential hazards to public safety. This study will apply non-destructive evaluation techniques to evaluate the detectability of damage accumulation in flat, flexible copper-conductor cables and discuss potential implications to their practical use.

42 ENGINEERING↗

A Dynamic Risk Framework for the Physical Security of Nuclear Power Plants

This paper describes ongoing work within the Light Water Reactor Sustainability pathway at Idaho National Laboratory (INL) to optimize the security and cost of nuclear power plants. It introduces the dynamic risk assessment tool developed at INL, Event Modeling Risk Assessment using Linked Diagrams (EMRALD). EMRALD is leveraged to optimize the security posture of a nuclear power plant by integrating force-on-force (FOF) simulations and operator mitigation actions, including dynamic and flexible coping strategies (FLEX). To illustrate the methodology, four attack scenarios are modeled in a commercially available FOF simulation tool using a hypothetical nuclear power plant facility. The simulation results provide valuable insights into possible attack outcomes, as well as the probabilistic risk of a core damage event given these outcomes. Safety mitigation procedures are modeled in EMRALD dependent on the attack outcomes by considering human operator uncertainties. The results demonstrate that the number of armed responders can be optimized, while still maintaining the same protection level as the initial security posture. The proposed modeling and simulation framework of integrating FLEX equipment with FOF models enables the nuclear power plants to credit FLEX portable equipment in the plant security posture, resulting in an efficient and optimized physical security system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Dynamic Risk Framework for the Optimization of Physical Security Posture of Nuclear Power Plants

This paper describes an ongoing work within the Light Water Reactor Sustainability pathway at Idaho National Laboratory (INL) to optimize security and cost of nuclear power plants. It introduces the dynamic risk assessment tool developed at INL, Event Modeling Risk Assessment using Linked Diagrams (EMRALD). EMRALD was leveraged to optimize the security posture of a nuclear power plant by integrating force-on-force (FOF) simulations and operator mitigation actions including the dynamic and flexible coping strategies (FLEX). To illustrate the methodology, four attack scenarios were modeled in a commercially available FOF simulation tool using a hypothetical nuclear power plant facility. The simulation results provide valuable insights into possible attack outcomes, as well as the probabilistic risk of core damage event given these outcomes. Safety mitigation procedures were modeled in EMRALD dependent on the attack outcomes by considering human operator uncertainties. The results demonstrate that the number of armed responders can be optimized, while still maintaining the same protection level as the initial security posture. The proposed modeling and simulation framework of integrating FLEX equipment with FOF models enables the nuclear power plants to credit FLEX portable equipment in the plant security posture, resulting in an efficient and optimized physical security system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

METHODOLOGY AND APPLICATION OF PHYSICAL SECURITY EFFECTIVENESS BASED ON DYNAMIC FORCE-ON-FORCE MODELING

This paper describes ongoing work within the Light Water Reactor Sustainability (LWRS) Program at Idaho National Laboratory (INL) to optimize security and cost of nuclear power plants (NPPs). It reviews the conservatisms in conventional physical security posture and regulations. It introduces the dynamic risk assessment tool developed at INL, Event Modeling Risk Assessment using Linked Diagrams (EMRALD). The dynamic assessment methodology leverages EMRALD to process results of force-on-force (FOF) simulations and crediting safety mitigation actions from probabilistic risk assessment (PRA) models as well as diverse and flexible coping strategies (FLEX) mitigation strategies. Timing information from these simulations are compared against the available time to perform mitigations obtained from Reactor Excursion and Leak Analysis Program (RELAP5) simulations. To illustrate the methodology, a station blackout (SBO) attack scenario was modeled in commercially available FOF simulation tools. The simulation results provide valuable insights into possible attack outcomes and as the probabilistic risk of a core damage event given these outcomes. Safety mitigation procedures were modeled in EMRALD, and were dependent on the attack outcomes by considering human operator uncertainties. RELAP5 simulations incorporating human and hardware uncertainties were performed to estimate the distribution of time-to-core damage. The results demonstrate that, even in the extreme case of a successful adversarial attack, plant mitigation strategies provide significantly high-likelihood of preventing radiological release. The proposed modeling and simulation framework of integrating FLEX equipment with FOF models enables the NPPs to credit FLEX portable equipment in the plant security posture, resulting in an efficient and optimized physical security.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

Moldable photovoltaic solar cell module

A moldable photovoltaic module is provided. The module includes a flexible polymeric flex-circuit substrate having an electrically conductive printed wiring pattern and solder pads defined on it. Small photovoltaic cells are affixed to the flex-circuit substrate by back-surface contacts in electrical contact with the solder pads. At least one thermoformable polymeric film is joined to the flex-circuit substrate. Each said solder pad comprises a solder composition that, after an initial melt, has a melting point that lies above at least a portion of the temperature range for thermoforming the polymeric film.

14 SOLAR ENERGY↗