Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Zircon, Baddeleyite, and Reidite Found in Ries Crater Suevite

Introduction: Impact events can generate superheated impact melts and even vapor [1]. In the past decade, evidence of the high temperatures and high pressures of the impact process has been found in the impact melt from terrestrial craters (e.g., Mistastin Lake [2], Meteor Crater [3]) and even on the Moon [4–5]. Often, these studies involve zircon or zirconium-bearing phases. Zircon is a particularly useful mineral, due to its robustness and durability against weathering. It is used principally for chronology, but it has a multitude of geologic applications, including geothermometry and fingerprinting magma sources. Here we focus on its capability of recording impact conditions. Grains of zircon (ZrSiO4) are converted at high temperature and/or pressure during an impact event to reidite (a high-pressure polymorph of ZrSiO4) or to tetragonal-ZrO2 + SiO2 [6]. Reidite and tertragonal-ZrO2 leave identifying relicts in the rocks, markers of the high pressures and/or temperatures these rocks underwent. Ries Crater is a 26-km-diameter peak ring crater in southern Germany that formed approximately 15 Ma [7–9]. Ries is the type locality of the polymict impact breccia known as suevite. Here, we report a microanalytical study of suevite from the Ries impact structure. These analyses are used to inform our understanding of the pressure and temperature conditions involved in creating a polymict impact breccia such as suevite in a peak ring crater. Sample Description: The sample, denoted 16RS08, originates from Otting Quarry, at 48.8777° N, 10.7921° E, approximately 17 km from the center of the Ries Crater in Germany (approximately 4 km outside the crater rim). The material recorded in sample 16RS08 is therefore considered an outer suevite. The outer suevite is a discontinuous layer of polymict impact breccia that occurs outside the central ring of Ries, up to 22 km from the center of the crater [9]. Lithic clasts in the outer suevite consist primarily of crystalline basement rocks (gneiss, granite, amphibolite), with less than 5% of lithic clasts being overlying sedimentary rocks (limestone, sandstone, shale) [9]. The thin section studied contains variably shocked lithic and mineral clasts, impact glass, and interstitial minerals that make up the matrix of the breccia (Fig. 1) [9]. Methods: We used a Cameca SX100 electron probe microanalyzer (EPMA) located in the Kuiper Materials Imaging and Characterization Facility (KMICF) at the University of Arizona to obtain 15 elemental X-ray maps of 16RS08. We next used the JEOL 7900F SEM at the Astromaterials Research & Exploration Science (ARES) at NASA Johnson Space Center (JSC) to obtain electron backscatter diffraction (EBSD) maps and energy dispersive X-ray spectroscopy (EDS) maps of select portions of the section. The EBSD data were collected under beam conditions of 20 kV, and ~9 μA, with step sizes varying from 0.05 to 2 μm. Following EBSD data collection, we processed the data using AZtecCrystal and MTEX, a free MATLAB toolbox. Results: We used the elemental X-ray maps to identify the areas of interest in the section, particularly phosphates and Zr-bearing grains. These areas of interest were then targeted for follow up EBSD and EDS analyses. We have identified, through combined EBSD and EDS analysis, the presence of zircon, reidite, and monoclinic-ZrO2 (baddeleyite) in 16RS08. In 16RS08, we have found singular grains of zircon, zircon with a vermicular baddeleyite halo (Fig. 2a), and granular zircon with reidite (Fig. 2b). The different Zr-rich phases and their corresponding textures signifies that this sample underwent a broad spectrum of pressure and temperature conditions during the impact event. For example, zircons surrounded by a vermicular baddeleyite and SiO2 intergrowth (i.e., Fig. 2a) have been shown to preserve evidence of the extremely high temperatures of impact melt, upwards of 2370 °C [2, 6]. Similarly, reidite and granular zircon (i.e., Fig. 2b) have been shown to preserve evidence of high pressure, as the transition to reidite occurs >30 GPa [3, 6]. Future Work: Next, we will process the EBSD and EDS data for these Zr-rich grains, specifically looking for indicators of cubic- or tetragonal-ZrO2 in the baddeleyite remnants and of shock-precursors to the reidite. To further inform our work, we will also obtain BSE images of these grains using a Hitachi S-4800 SEM in KMICF at the University of Arizona, as well as geochemical spot analyses via EPMA. The data collected will be used to constrain the formation conditions of the Ries Crater outer suevite. Acknowledgments: We thank Ken Domanik and Jerry Chang for their support with data collection. This work was supported by a University of Arizona RII Core Facilities Pilot Program grant and start-up funds to JJB. TME thanks A. Cavosie and N. Timms for assistance during field sampling. We acknowledge support from NASA’s Planetary Science Research program for analysis performed at JSC. References: [1] Melosh H. J. (1989) Oxf. U. Press. [2] Timms et al. (2017) EPSL 477, 52–58. [3] Cavosie et al. (2016) Geology 44:9, 703–706. [4] White et al. (2020) Nature Astr. 4, 974–978. [5] Crow C. A. et al. (2017) GCA 202, 264–284. [6] Timms et al. (2017) Earth-Sci. Rev. 165, 185–202. [7] Schmieder M. et al. (2018) GCA 220, 146–157. [8] Schwarz W. H. et al. (2020) M&PS 55:2, 312–325. [9] Stöffler et al. (2013) M&PS 43:4, 515–589.

Zircon↗

Pink Spinel in Apollo Impact Melt Rock 68815: Implications for Mg-Suite Magmatism

Introduction: Magnesian rocks from the lunar highlands are collectively termed the Mg-suite. Characterized by high (>60) Mg# (molar 100×Mg/[Mg+Fe]) in mafic phases and calcic plagioclase, these rocks are plutonic to hypabyssal in origin, and include a range of bulk mineralogies such as troctolites, dunites, norites, gabbronorites, and spinel troctolites [1]. These Mg-suite lithologies have distinct trace element concentrations and ratios that differentiate them from other lunar rock types. These rocks are ancient, generally dated to between 4.5 and 4.1 Ga, although it is unknown if this represents the full range of Mg-suite ages [1–2]. Among the Mg-suite lithologies, the spinel troctolites are relatively rare, to date only found in polymict breccias [3]. Spinel troctolites, as their name suggests, consist of calcic plagioclase and forsteritic olivine, with minor amounts of spinel (MgAl2O4), ± pyroxene and cordierite [1,4]. This form of spinel is often called ‘pink’ spinel because of its appearance in thin section under plane polarized light (PPL; Fig. 1), due to minor amounts of Cr. Spinel troctolites are generally plutonic or hypabyssal in origin (subsequently exhumed and incorporated into polymict breccias), or formed through impact processes (e.g., crystalline impact melt) [5]. A spinel-rich lithology has also been found in the Moscoviense region of the Moon via the Moon Mineralogy Mapper (M3) and lacks other mafic phases [6]. Finally, while the Mg-suite sampled thus far consists of plutonic (or hypabyssal) rocks, the question remains if such magmas could have erupted on the surface of the Moon [7]. These magmas have much lower density than mare basalts, but little sample or remote sensing evidence has been found to support the idea that extrusive Mg-suite volcanism occurred [7]. Here, we present a coordinated microanalytical study of spinel-bearing lithic and mineral clasts found in Apollo sample 68815. These data will be used to understand their petrogenesis (magmatic or impact) and modification histories, and to shed light on the existence of volcanic Mg-suite rocks. Sample Description: Apollo sample 68815 is a polymict impact melt breccia containing a variety of lithic and mineral fragments embedded in devitrified impact melt. This sample was chipped off the top of a boulder at Station 8 during the Apollo 16 mission and had an original weight of nearly 1.8 kg. In this study, we investigated two polished thin sections of 68815: 68815,17 and 68815,148, both containing spinel. Methods: The thin sections of 68815 were studied using optical light microscopy (PPL, cross-polarized light, and reflected light) with a Keyence VHX-7100 Digital Microscope. Each section was then X-ray mapped for 13–14 elements using a Cameca SX100 electron probe microanalyzer (EPMA) located in the Kuiper Materials Imaging and Characterization Facility (KMICF) at the University of Arizona. We have obtained geochemical information about the phases (olivine, plagioclase, spinel, pyroxene) in the thin sections also using the EPMA. In addition, we have used ThermoScientific Helios NanoLab 660 Focused-Ion-Beam Scanning-Electron Microscope (FIB-SEM) and a Hitachi S-4800 SEM (both in KMICF) to obtain backscattered electron (BSE) images and energy dispersive Xray spectrometry (EDS) maps of areas of interest. Using a JEOL 7900F SEM at the Astromaterials Research & Exploration Science (ARES) at NASA Johnson Space Center (JSC), we have obtained electron backscatter diffraction (EBSD) maps of the spinel-bearing portions of the thin sections. The EBSD data were collected under beam conditions of 20 kV, and ~90 μA, with step sizes varying from 0.05 to 2 μm. Following EBSD data collection, we processed the data using AZtecCrystal and MTEX, a free MATLAB toolbox. Results: We have found clasts with subophitic textures, that consist of primarily olivine and plagioclase, with minor amounts of pink Mg-Al spinel and pyroxene (Fig. 1). These clasts are up to ~1 mm in length and contain spinels up to 50 μm across. We have additionally identified pink Mg-Al spinels within the impact melt (i.e., not contained in lithic clasts) in both thin sections. In one instance, a single spinel grain is approximately 300 μm across (Fig. 1b, 2). The spinel fragments embedded in impact melt have varying compositions, typically distinct from the compositions of spinels in the lithic clasts. Spinel-Bearing Clasts: Ten lithic clasts with similar textures and mineral compositions were identified between 68815,17 (two clasts) and ,148 (eight clasts). These clasts fall into two groups. The first has skeletal olivine with intergranular plagioclase, with minor amounts of pyroxene and spinel (Fig. 1a, 2c, 2d). The spinel in these clasts are found amid the plagioclase. The second group have an intergranular texture of olivine and plagioclase, again with minor spinel and pyroxene. The second group may contain spinels surrounded by plagioclase, and spinels enclosed in olivine. Spinels located within both clast types range from no apparent Cr zoning, to reverse zoning (Cr-enrichment inward; Fig. 2d), to normal zoning (Cr-enrichment outward). In the clasts thus far investigated with EPMA, plagioclase compositions range from An# (molar 100×Ca/[Ca+Na+K]) 92–96. Olivine Mg# ranged from 77 to 94, while pyroxene had Mg# from 54–84. Spinel in the clasts have Cr# (molar 100×Cr/[Cr+Al]) 2–4 and Mg# 88–91, which is within the range of pristine and plutonic spinel troctolites [8]. Isolated Spinels: These crystals are generally euhedral to subhedral, and can exhibit reverse Cr zoning (Cr enrichment inward) or no apparent Cr zoning. The spinels thus far investigated via EPMA have Cr# 9–14 and Mg# 65–82. The Cr# for these spinels is within the range reported by [8], but have lower Mg#. Future Work: We will continue to process the EBSD data for these lithic and mineral clasts. We will also continue to characterize these clasts using EPMA and SEM. By thoroughly characterizing the various spinels and spinel-bearing clasts, we aim to constrain the petrogenesis of these minerals and rock fragments. Acknowledgments: We thank NASA for the loan of these thin sections. We thank Ken Domanik and Jerry Chang for their support with data collection. Work was supported by a University of Arizona RII Core Facilities Pilot Program grant and start-up funds to JJB. We acknowledge support from NASA’s Planetary Science Research program for analysis performed at JSC. References: [1] Shearer C. K. et al. (2015) Am. Min. 100, 294–325. [2] Borg L. E. et al. (2020) GCA 290, 312–332. [3] Warren P. H. (1993) Am. Min. 78, 360–376. [4] Dymek R. F. et al. (1976) LPS VII, 2335–2378. [5] Treiman et al. (2019) Am. Min. 104, 370–384. [6] Pieters et al. (2011) JGR: Plan. 116:E00G08. [7] Prissel et al. (2016) Icarus 277, 319–329. [8] Prissel et al. (2016) Am. Min. 101, 1624–1635.

spinel↗

Investigation of Geomorphological Signatures of Permafrost in the Polar Lunar Areas With VIPER

A study of images of the polar regions shows that small craters near the poles of the Moon are distinguished by the following features: 1. they have a smoother shape - see Fig (a); 2. patterned ground (“wrinkled skin”) is often observed in and around the crater - see Figs (a,b,c); 3. outside the craters landslides and cracks are noticeable - see Fig (d); 4. layers or scarps are often visible on the inner slope - see Fig (e). These features (scarps and patterned ground) are typical for Martian craters in the permafrost zone (see Fig f), as well as for similar zones on Earth. It is hypothesized that these features of lunar craters are associated with the presence of permafrost in the polar regions of the Moon. In 2023, the VIPER rover will investigate the distribution of ice (volatile) deposits in the region of the Moon's South Pole. VIPER navigation cameras represent a unique opportunity for the geomorphological analysis of the lunar surface and the study of physical properties of regolith due to multiple key factors: - A large number of high-quality digital images with a good resolution of the South Pole of the Moon, which is a key region for the landing of manned expeditions. - A low position of the Sun, which generates long shadows, creates favorable conditions for object recognition algorithms. - A presence of a rover track in the images enables VIPER wheels to be used as tools for the study of the regolith and the development of a geotechnical model of regolith in the South Pole region. Rover navigation cameras will allow investigation of the distribution and shape of small craters and other structures along the path of the rover and test the hypothesis about geomorphological signatures of permafrost in the lunar polar areas. If a relationship between characteristics of lunar craters and the distribution of permafrost is confirmed, this will open a possibility to remotely determine the deposits of lunar ice from satellite imagery.

VIPER↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

An Optimization Approach to Support Science Decision Making for Lunar Surface Exploration

Introduction: Scientific exploration is one of the three pillars of NASA’s Moon2Mars architecture, with crew surface extra vehicular activities (EVA) serving a critical enabling function. Development of surface EVA operational planning and execution, specifically integrating science and flight control teams (FCT), is currently being explored through analog scenarios. This integration, exercised, for example, through the Joint EVA and Hu-man Surface Mobility Test Team (JETT), allows for science input on EVA activities in near real-time through a Science Evaluation Room (SER), or Arte-mis science backroom, which integrates with the broader FCT through the Science Officer. The SER works within the FCT to support dynamic EVA planning in response to changes in operational constraints as well as science opportunities and re-prioritization, increasing the mission science return and accelerating the accomplishment of the Moon2Mars science objectives. The SER works within the FCT to provide recommendations to traverse execution in near real-time. One challenge is the requirement to deliver SER inputs to the FCT on operationally relevant timelines. Failure to do so may result in suboptimal execution of science exploration EVAs or even loss of key science objectives. To close this gap, we present a network optimization tool to allow the SER to provide rapid input to the FCT in response to changes in operational constraints or science opportunities. Inputs are predicated on approved science objectives, and clear rationale must be provided to the FCT for any requested change. Accordingly, this tool incorporates the Science Traceability Matrix (STM), SER prioritization scheme, and station characterization and action planning with operational constraints such as duration, traverse speed, and distance to maximize science objectives based on SER priorities, consistent with FCT operational requirements. Method: As a proof of concept, we used an existing linear programing software package used to simulate optimal routes through cellular metabolism. We built a Demonstrative Model with three STM objectives and four stations on a region of the Moon. The objectives were given an arbitrary prioritization and mapped to the stations through four possible crew actions. (Figs. 1 and 2). This station to STM mapping is consistent with the method used by the JETT5 Science Team to develop analog surface EVA science planning. We used a grid system with the landing site at the origin and the four stations placed across the positive x,y quadrant. Actions were assigned to each station and the accomplishment of those actions resulted in a numerical “reward” based on the ability of that action to achieve science objectives. The aggregate reward from each individual STM objective contributes to a global score (Science Yield), weighted by its priority. Operational constraints included a requirement to start and end at the landing site, 5 minutes each for initial station characterization and “clean up,” and variable total EVA time, traverse rate (fixed to 0.5 meters per second in our example), and time to perform each action (10, 5, 7, and 15 min for actions 1, 2, 3, and 4, respectively). Additional constraints and variables will be added in the future (e.g., sample mass, number of stations, traverse route constraints, illumination). Optimization. We converted the connections (arcs) between these stations (nodes) into a mixed integer linear programming optimization problem (arcs = constraints, nodes = variables) with the objective to maximize Science Yield. For any action, the Science Yield is equal to the relevance of that action to an STM objective [3, 2, and 1 point(s) for High, Med., and Low relevance, respectively], multiplied by the STM Objective Priority [3, 2, and 1 point(s) for High, Med., and Low priority, respectively]. This resulted in a model that computes the optimal station and action combination to maximize the Science Yield. These weightings can be adjusted by the SER as desired. Results: We explored three test cases for the Demonstrative Model. First, we set the maximum EVA duration to 120 minutes and computed the optimal route (Fig. 3A). The model suggested per-forming Actions 1 and 2 at Station P01, followed by Actions 1 and 2 at Station P02, and finally Actions 1 and 3 at Station P04 before returning to the Landing Site. Second, we adjusted the STM Objective Priori-ty order and computed the new optimal route (Fig. 3B). Under this situation, the model suggested per-forming all Actions at Station P02 followed by all Actions at Station P03. The previous test cases were relevant to SER planning activities. Next, we explored providing mid-EVA replanning input to the FCT. Scenario: While executing the Route in Fig. 3A the crew finishes at Station P01 and FCT decides that the EVA needs to finish in 45 minutes back at the Landing Site. FCT asks SER to recommend changes to the plan to accommodate this operation-al change. Using the model and incorporating these new constraints (start at Station P01, max. time of 45 min), the model suggested performing Actions 2 and 4 at Station P03 (Fig. 4), requiring 41 minutes to complete and return to the Landing Site. Interestingly, Station 3 was not part of the original route. Using the model, we determined the EVA would need 66 minutes, instead of 45, in order for the original Station P04 to yield a larger Science Yield than Station P03. The parametrization and simulation was per-formed in less than a minute, demonstrating the operational relevance of the approach. Future Efforts: The results from the Demonstrative Model suggest this tool can accelerate SER decision making on operationally relevant timelines. Use in analog activities, such as JETT5 or follow-ons, which have over a dozen stations for a crew to explore and over a dozen actions per station, will provide needed validation of the utility of this tool for planning EVAs, replanning mid-EVA, or planning follow-on EVAs based on previous results. Further integration with FCT execution monitoring tools may provide additional efficiency gains, al-lowing rapid and iterative exploration of operation-al and science decision space by the FCT and SER.

Science Operations↗

Investigation of Hardware and Instrumentation to Measure Hand Grasp Activity with the Spacesuit Gloves

Introduction: During the 2022 suited injury summit, it was hypothesized that there will be concerns for hand and glove injuries for future exploration space missions, especially given the fact that the “total number of Extravehicular activity (EVA) hours and frequency” for lunar surface missions is expected to vastly increase [1]. It has been reported that the hands experienced the greatest “absolute numbers” of reported injuries and far exceeds other injuries during EVA [1, 2]. It was reported that the most fatiguing part of the surface EVA was the repetitive gripping tasks [3]. It was recommended that a “glove sub-team” be created to look at possible injury mechanism and mitigation strategies. Some of the recommendations that were suggested [1] are as follows: examine hand fatigue, utilize motion capture, examine the duration and frequency of hand movements, and identify frequent hand motions. We started assessing hardware and instrumentation to measure hand grasp activity in the pressurized glove environment. The purpose of this test was to perform a hardware evaluation for motion capture (MoCap) gloves obtained from StretchSense (Auckland, New Zealand). The specific gloves used were the Pro Fidelity and SuperSplay to determine the repeatability, reliability, feasibility, and useability inside of a pressurized gloved environment. Methods: The MoCap gloves were customized (e.g., battery/Bluetooth pack relocated to upper arm) to better suit the pressurized testing environment and protect the subject from unintentional injury (Fig. 1). Fourteen total subjects from different demographics (i.e., gender and pressurized glove experience level) participated in this test series. Testing included one session each of a baseline data collection (NASA Johnson Space Center (JSC) building 21) and a spacesuit glove box (Fig. 2 at JSC building 7 room 2027) data collection (under vacuum down to 4.3 psid), where each session lasted 3-5 hours. Controlled and reproducible tasks to systematically evaluate the repeatability and reliability of the hardware were performed during baseline data collection. Additionally, subjects performed simulated EVA-like tasks in a pressurized gloved environment. For all sessions, MoCap gloves were placed on each of the subjects’ hands and the signal from it, or the raw capacitance (Fig. 3), was analysed. The raw capacitance was used to estimate the open and closed hand states between the testing conditions and allow us to provide an offset caused by the pressurized environment. Results & Discussion: Initial observation with the bare hands (baseline) condition showed that the MoCap gloves appeared to track grasping and releasing of the fingers (opening and closing fist) with both high- and low-speed conditions, while adduction and abduction of the fingers were not relatively tracked. A hardware evaluation was done outside of the glove box to assess the reliability and repeatability of the MoCap glove. In one task, a point force was applied to various locations on the back of the hand. When the point force was applied to the space between the 1st digit and the pointer finger, there was a noticeable distortion to the MoCap data. Another task examining an increasing force from a 10 lb. sandbag applied to the back of the hand while lying flat on a table, showed a constant flat line with only a distortion when the weight was increased or added to the back of the hand. Fig. 3 shows an object relocation task where you can see when each individual finger “opened” and “closed” (changed position) when picking up and setting down the dumbbell. When the fingers were stationary, the signal remained relatively flat compared to the peaks and valleys that can be observed in Fig. 3. This study showed promising results and imperative input into an attempt to discriminate between hand states across various functional tasks and should be evaluated with context to the repeatability and reliability outcomes. Depending on the task done inside of the pressurized glove box environment and outside, the results appear to be affected by many different factors (i.e., drift, pressure, hand size, etc.). Significance: If this hardware proves to be reliable and repeatable in determining the open and closed hand states then this may provide critical insight into assisting in the characterization of the pressurized gloved environment and the effect on crew member exertion level. Ultimately, this tool will provide useful data for quantifying the repetitive nature of EVA training and tasks. Acknowledgments: The authors would like to acknowledge the NASA Mars Campaign Office for providing funding for this research. Lastly, thanks to all the engineers and technicians at NASA JSC who helped with this data collection. References: [1] Reiber, et al. (2022), NASA/TM-20220007605; [2] Scheuring, et al. (2009), Av., Sp., and Envir. Med. 80(2). [3] Scheuring, et al. (2007), NASA/TM–2007–214755.

Rachel L Thompson↗

FInd Gas Source

FIGS is a neural network software that ingests real time synchronized field data on environmental flow fields and turbulence and gas concentration variations at high frequency and uses an error minimization algorithm to locate the gas source and quantify its strength. The software can be interfaced with atmospheric, oceanic and subsurface instruments in a variety of platforms stationary or mobile (e.g. cars, UAVs, submersible vehicles or boreholes) and used to find gas sources by smart use of data and phenomenology. FIGS can be trained by phenomenological model of the flow fields in the environment of interest and/or be calibrated by controlled release. After initial deployment the FIGS learning will grow with time as it accumulates data on source quantification. FIGS can be installed on any computer from small beagle-bones for field deployment/end-use to PC/MACs/main-frame for training/analysis. FIGS has been trained (using LANL's high resolution atmospheric simulations) and calibrated, tested and evaluated in the field and shown to perform well in finding and quantifying methane leaks at 10-100m scales at well pads by ingesting atmospheric measurements. The code is applicable to gas and particle source location at large scales.

Travis, Bryan↗

Efficacy of antivirals and mRNA vaccination against an XBF clinical isolate

Recombination events occur frequently in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), resulting in genetic diversity. Because these events contribute to altered host immune evasion and antiviral susceptibility, it is crucial to evaluate the efficacy of COVID-19 vaccines and antivirals against recombinant variants. As of March 2023, XBB.1.5, a recombinant sublineage of XBB, is currently the dominant form globally (Fig. S1A, Supplementary Appendix). XBB emerged as a result of recombination between two BA.2 descendants, BJ.1 and BM.1.1.1 (a progeny of BA.2.75). We and other groups have shown that XBB.1.5 is resistant to several therapeutic monoclonal antibodies and effectively evades humoral immunity elicited by natural infection or COVID-19 vaccination.1, 2, 3 By March 30, 2023, an additional recombinant variant, XBF, had been sampled 8966 times in 47 countries and territories in GISAID, reaching it highest prevalence in Australia and New Zealand (Fig. S2, Supplementary Appendix). XBF is still increasing in frequency, although the prevalence of XBB.1.5 appears to be increasing at a faster pace in most regions (Fig. S1B, Supplementary Appendix). XBF is a recombinant of BA.5.2.3 (a descendant of BA.5) and CJ.1 (a descendant of BA.2.75) and, like CJ.1, has an additional three substitutions (R346T, F486P, and F490S) in the receptor-binding domain (RBD) of the consensus form of its spike protein compared to baseline BA.2.75 (Fig. S3A, Supplementary Appendix). CJ.1 and its related sublineage CJ.1.1 did not expand as extensively as XBF, being sampled in GISAID only 1589 and 142 times respectively. CJ.1 was found circulating in many countries, but most commonly sampled in South Korea, where it is still increasing and has currently reached about 5% of the sampled population. CJ.1.1 was most frequently sampled in Malaysia and Singapore, but remained rare in both nations, peaking at about 1% of the sample in December of 2022. Despite the importance of these related variants, we have no information about the antiviral efficacy and immunity induced by COVID-19 vaccines against a clinical isolate of XBF.

60 APPLIED LIFE SCIENCES↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

Publisher Correction: Engineering bacterial vortex lattice via direct laser lithography

The original version of this Article contained errors in Fig. 2. In Fig. 2d, the label below the blue circle incorrectly read “S i,a (t) < 0” and should have read “S i,a (t) > 0”. Furthermore, the sequence of labels on the side of the bottom three panel in Fig. 2 from top to bottom incorrectly read “S 9,70 > 0, S 9,70 > 0, S 9,70 < 0”, and should have read “S 9,70 < 0, S 9,70 > 0, S 9,70 < 0”. Finally, in the legend to Fig. 2, the scale bar size description “Scale bar: 100 μm” was incorrectly placed in the description of panel c, and should have been placed in the description of panel d. These errors have been corrected in both the PDF and HTML versions of the Article.

59 BASIC BIOLOGICAL SCIENCES↗

Comment on 'Mapping of localized spin-wave excitations by near-field Brillouin light scattering' [Appl. Phys. Lett. 97, 152502 (2010)].

The authors reported in their letter some outstanding experimental results of spin excitations in nano-particles investigated by near-field Brillouin scattering. They conclude from their observations that existing theories -- in particular micromagnetic simulations -- do not correctly describe the behavior of the spin modes. Since excellent agreement has been reported between spin-wave mode frequencies obtained from Brillouin scattering experiments and those obtained from micromagnetic-based simulations, it is somewhat surprising that the simulations should fail for the particles investigated in Ref. 1. In the literature, there is also evidence of various kinds and degrees of mode localization when exchange competes with dipolar interactions. When dipolar long-range interactions are taken into account, the eigenmodes can be seen as the superposition of plane waves, leading to different localizations and in particular to the appearence of bulk-dead modes. We have simulated the normal modes of the particles used in Ref. 1, with the dynamical matrix method; the results are shown in Fig. 1 for different values of the applied field. In addition to the lowest frequency non-localized mode (1-BA), several localized modes are present. Large particles exhibit modes with oscillations along the field direction;8 for such modes, we use the label n-BA-loc, with n the number of nodes. While the profile of the pure end-mode, i.e., 0-BA-loc, has its maximum at the edge with the amplitude monotonously decreasing toward the interior of the ellipse, as correctly described by the authors, the localized modes with n > 0, not considered by them, do not have this characteristic: see inset of Fig. 1. Based on Fig. 1, we believe that the assumption that the mode they observe is 'the' localized spin mode is not correct. Instead, we believe that the mode detected in the experiment at H > 700 Oe is a combinations (due to non-linear excitation conditions of the experiment) of several n-BA-loc modes, with n?>?0. In this picture, the sharp peaks of the n-BA-loc modes are smoothed in the experimental measurements, thanks to the superposition of modes with different nodal lines. Finally, at 350 Oe, the measured profile and frequency suggest that the mode seen in the experiment may be well due to the 1-BA mode. The observed change in mode profile at 350 Oe is substantiated by the frequency behavior shown in Fig. 3(b) of Ref. 1, where it can be observed that the frequency of the low-field point does not lie on the same curve as the high-field points. In summary, before concluding that micromagnetic-based simulations of spin wave modes in nano-particles are unreliable, we believe that it is necessary to await either the simulation of large particles using small cell sizes or for more exhaustive experiments reaching lower frequencies on particles of varying size. The comparison of calculations with experiment would greatly benefit if the authors were to provide the field dependence of all the modes detected in their experiment (in order to achieve a proper assignment).

36 MATERIALS SCIENCE↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

Analyzing diffuse scattering with supercomputers. Corrigendum

The study by Michels-Clark et al. (2013 [Michels-Clark, T. M., Lynch, V. E., Hoffmann, C. M., Hauser, J., Weber, T., Harrison, R. & Bürgi, H. B. (2013). J. Appl. Cryst. 46, 1616-1625.]) contains misleading errors which are corrected here. The numerical results reported in that paper and the conclusions given there are not affected and remain unchanged. The transition probabilities in Table 1 (rows 4, 5, 7, 8) and Fig. 2 (rows 1 and 2) of the original paper were different from those used in the numerical calculations. Corrected transition probabilities as used in the computations are given in Table 1 and Fig. 1 of this article. The Δ parameter in the stacking model expresses the preference for the fifth layer in a five-layer stack to be eclipsed with respect to the first layer. This statement corrects the original text on p. 1622, lines 4–7. In the original Fig. 2 the helicity of the layer stacks b L and b R in rows 3 and 4 had been given as opposite to those in rows 1, 2 and 5. Fig. 1 of this article shows rows 3 and 4 corrected to correspond to rows 1, 2 and 5.

97 MATHEMATICS AND COMPUTING↗

Photonic ring resonator notch filters for astronomical OH line suppression

Photonic ring resonator arrays used as notch filters are a promising novel solution to improve the signal-to-noise ratio of ground-based astronomical observations by suppressing OH emission lines in the near-infrared (NIR) wavelength range (0.9-2.5 μm). We aim to fabricate a series of ring resonators connected by a waveguide, each with its resonance wavelength and full-width-half-maximum (FWHM) matched with one of the OH emission lines. The fundamental structure of ring resonator-based notch filters is a ring resonator evanescently coupled to a waveguide. Due to the optical loss of the ring resonator, the transmission of light through the waveguide will be suppressed at the resonance wavelength of the ring resonator. The degree of suppression can be controlled by varying the coupling strength between the waveguide and the ring resonator, while the resonance wavelength can be controlled by the geometry and size of the ring. However, since a single ring resonator has multiple modes each with a different wavelength separated by its free spectral range (FSR), the additional suppression at other wavelengths may undermine the signal. Therefore, the ideal FSR off the ring resonators needs to be larger than the measurement window. For this application, we aim the FSR to be 1 larger than 30 nm . Our initial measurement results revealed two major challenges for this application. First, the FSR of the ring resonators is limited by the bending loss of ring resonators. In a standard 220 nm silicon-on-insulator material platform, the FSR of ring resonators cannot exceed 30 nm; Second, due to the wafer thickness variation and fabrication inaccuracy, the achievable accuracy in the resonance wavelength of a fabricated single ring resonator is only ~1.5 nm. In this work, we report our novel solutions to the above two challenges. For the first one, we have developed a novel structure based on the Vernier effect to greatly raise the FSR of ring resonators. Serially coupled Vernier ring structures is a typical approach to increase the FSR without encountering bending loss, but it requires restrictive matching of the coupling and optical loss of the rings and any imperfect matching can result in even noisier signals. On the contrary, our structure, as shown in shown in Fig. 1, does not require the restrictive matching. The signals of two output ports in our structure marked in Fig. 1 will be added together to form the final output signal, and Fig. 2 shows the finite-difference time-domain (FDTD) simulation results of the final output signal. As can be seen, the FSR of the entire structure is well-beyond 60 nm with little noise at other wavelengths. For the second one, we have developed an easy-to-implement method to permanently tune the resonance wavelengths of ring resonators within 0.1 nm accuracy. The tuning mechanism is based on the property of hydrogen silsesquioxane (HSQ) resist. As a negative tone electron beam resist, HSQ upon exposure will cross-link and eventually form SiO2. The refractive 2 index of HSQ resist and formed SiO2 are slightly different , enabling the tuning. By having a thin layer of HSQ resist on top of ring resonator structures followed by SiO2 cladding, the resonance wavelengths of ring resonators can be post-tuned Advances in Optical Astronomical Instrumentation 2019, edited by Simon Ellis, Céline d'Orgeville, Downloaded From: https://www.spiedigitallibrary.org/conference-proceedings-of-spie on 23 Sep 2020 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use through electron beam exposure. We have found that, within 5 nm tuning range, the resonance wavelength shift and dosage applied obeys a linear relationship. So a simple calibration beforehand can result in resonance wavelength tuning within 0.1 nm accuracy. The transmission spectra of a 3-ring device before and after tuning is shown in Fig. 3.

Astronomical optics↗

TU-F-12A-06: BEST IN PHYSICS (IMAGING) - A Novel Catheter-Based Radionuclide Imaging System to Characterize Atherosclerotic Plaque

Purpose: Atherosclerosis underlies coronary artery diseases, the leading cause of death in the United States and worldwide. In this study, we developed a novel catheter-based radionuclide imaging (CRI) system to image 18F-fluorodeoxyglucose (18F-FDG), a radionuclide, a marker of vascular inflammation, in murine carotid arteries and characterized the system for spatial resolution from multiple scintillating materials. Methods: The catheter system includes 35 mm and 8 mm fixed focal length lenses, which are subsequently connected to a CMOS camera and fiber holder. The distal ferrule of an image bundle is terminated with a wide-angle lens. The novelty of this system is a scintillating balloon with a crystal tip in the front of the wide angle lens to image light from the decay of 18F-FDG emission signal. The scintillating balloon is fabricated from 1mL of silicone RTV catalyst mixed with 1 mL base and 50 mg/mL calcium fluoride doped with Europium (CaF2:Eu). To identify the optimal scintillating materials with respect to resolution, we calculated modulation transfer function (MTF) of Yttrium Aluminum Garnet doped with Cerium (YAG:Ce), anthracene, and CaF2:Eu phosphors using a thin line optical phantom (Fig. 1a-1b). Macrophage-rich FVB murine atherosclerotic carotid plaque model (n = 4) was used in ex vivo experiments. Confirmatory imaging was also performed by an external optical imaging system (IVIS-200). Results: Analysis of the different phosphors (Fig 1b) showed that CaF2:Eu enabled the best resolution of 1.2μm. The CRI system visualized 18F-FDG in atherosclerotic plaques (Fig. 1d). The ligated left carotid (LR) artery exhibited 4× higher 18F-FDG signal intensity compared to the non-ligated right carotid (negative control) artery (1.65×10{sup 2} ±4.07×10{sup 1} vs. 4.44×10{sup 1}±2.17×10{sup 0}, A.U., p = 0.005) and confirmed with IVIS-200 (Fig. 1d). Conclusion: This CRI system enables high-resolution and sensitive detection of 18F-FDG uptake by murine atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

Correction to: Quantitative phosphoproteomic analysis reveals reciprocal activation of receptor tyrosine kinases between cancer epithelial cells and stromal fibroblasts

Unfortunately, after publication of this article [1], errors were noticed in Figs. 3 and 4. The “T” in the word “pTyr” was missing in Fig. 3. The word “change” was missing after the word “Fold” in the label of y axis in Fig. 4a. The “e” in the word “Co-culture” was missing in Fig. 4a. The correct figures are presented in this correction. The original article has also been updated.

60 APPLIED LIFE SCIENCES↗

Programmable Phase Selection between Altermagnetic and Noncentrosymmetric Polymorphs of MnTe on InP via Molecular Beam Epitaxy

This dataset contains DFT input and output files supporting the theoretical modeling in the associated publication (ACS Appl. Mater. Interfaces 2026, 18, 15654-15664). The calculations model the interfacial energetics of two MnTe polymorphs — NiAs-MnTe (hexagonal, alpha phase) and ZnS-MnTe (cubic, gamma phase) — on InP(111) substrates with two surface terminations: In-terminated InP(111)A and P-terminated InP(111)B. This gives four interface configurations: NiAs on In-terminated (experimentally observed), NiAs on P-terminated (computed for comparison), ZnS on In-terminated (computed for comparison), and ZnS on P-terminated (experimentally observed). The dataset is organized into four calculation types, each covering all four polymorph/termination combinations: (i) Slabs: Pristine MnTe/InP heterostructure slabs used to compute total energies and interface energy densities (Eint) for all four configurations, as reported in Fig. 6 of the main text. (ii) Disorder: Same slab geometries with a P_Te + Te_P antisite defect pair introduced near the interface, used to assess chemical intermixing effects on interface stability (Fig. S8, SI). (iii) Strain: Pristine slab calculations with in-plane lattice parameters strained by -1% and +1% relative to the InP lattice constant, used to evaluate strain-dependent interface energetics (Fig. S9, SI). (iv) Charge_Density: Single-point calculations on the full heterostructure, the isolated InP slab, and the isolated MnTe slab at fixed geometry, used to compute differential charge density plots showing interfacial charge accumulation and depletion as a function of surface termination (Fig. S10, SI). Each calculation folder contains INCAR, KPOINTS, POSCAR, CONTCAR, OUTCAR, and POTCAR_info.txt (PAW potential information, excluding the full POTCAR due to VASP licensing restrictions). The calculations were performed using VASP 6.4.3 with PBE exchange-correlation, PAW potentials, a Hubbard correction of Ueff = 5 eV on Mn d-states, and A-type AFM spin initialization.

36 MATERIALS SCIENCE↗

Model, data, and code for paper "Modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x"

The data package includes data, model, and code that support the analyses and conclusions in the paper titled “modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x”. The primary goal of this paper is to demonstrate that key streamflow properties such as water depth, flow velocity, and dynamic pressure in a natural river at 30-kilometer scale over 5 years can be reliably and efficiently modeled using the computational framework presented in this paper. To support the paper, various data types from remote sensing, field observations, and computational models are used. Specific details are described as follows. Firstly, the river bathymetry data was obtained from a Light Detection and Ranging (LiDAR) survey. This data is then converted to a triangulated surface format, STL, for mesh generation in OpenFOAM. The STL data can be found in Model_Setups/BaseCase_2013To2015/constant/triSurface. The OpenFOAM mesh generated using this STL file can be found in constant/polyMesh. Other model setups, boundary and initial conditions can be found in /system and /0.org under folder BaseCase_2013To2015. A similar data structure can also be found in BaseCase_2018To2019 for the simulations during 2018 and 2019. Secondly, the OpenFOAM simulations need the upstream discharge and water depth information at the upstream boundary to drive the model. These data are generated from a one-dimensional hydraulic model and the data can be found under the folder Model_Setups /1D model Mass1 data. The mass1_65.csv and mass1_191.csv files include the results of the 1D model at the model inlet and outlet, respectively. The Matlab source code Mass1ToOFBC20182019.m is used to convert these data into OpenFOAM boundary condition setups.With the above OpenFOAM model, it can generate data for water surface elevation, flow velocity, and dynamic pressure. In this paper, the water surface elevation was measured at 7 locations during different periods between 2011 and 2019. The exact survey locations (see Fig1_SurveyLocations.txt) can be found in folder Fig_1. The variation of water stage over time at the 7 locations can be found in folder /Observation_WSE. The data type include .txt, .csv, .xlsx, and .mat. The .mat data can be loaded by Matlab.We also measured the flow velocities at 12 cross-sections along the river. At each cross-section, we recorded the x, y locations, depth, three velocity components u,v,w. These data are saved to a Matlab format which can be found under folder /Observation_Velocity and /Fig_1. The relative locations of velocity survey locations to the river bathymetry can be found in Figure 1c.The water stage data at the 7 locations from OpenFOAM, 1D, and 2D hydraulic models are also provided to evaluate the long-term performance of 3D models vs 1D/2D models. The water stage data for the 7 locations from OpenFOAM have been saved to .mat format and can be found in /OpenFOAM_WSE. The water stage data from the 1D model are saved in .csv format and can be found in /Mass1_WSE. The water stage from the 2D model is saved as .mat format and can be found in / Mass2_WSEIn addition, the OpenFOAM model outputs the information of hydrostatic and hydrodynamic pressure. They are saved as .mat format under folder /Fig_11/2013_1. As the files are too large, we only uploaded the data for January 2013. The area of different ratio of dynamic pressure to static pressure for all simulation range, i.e., 2013-2015, are saved to .mat format. They can be found in /Fig_11/PA. Further, the data of wall clock time versus the solution time of the OpenFOAM modeling are also saved to .mat format under folder /Fig_13/LogsMat. In summary, the data package contains seven data types, including .txt, .csv, .xlsx, .dat, .stl, .m, and .mat. The former 4 types can be directly open using a text editor or Microsoft Office. The .mat format needs to be read by Matlab. The Matlab source code .m files need to be run with Matlab. The OpenFOAM setups can be visualized in ParaView. The .stl file can be opened in ParaView or Blender. The data in subfolders Fig_1 to Fig_10 and Fig_12 are copied from the aforementioned data folders to generate specific figures for the paper. A readME.txt file is included in each subfolder to further describe how the data in each folder are generated and used to support the paper.Please use the data package's DOI to cite the data package. Please contact yunxiang.chen@pnnl.gov if you need more data related to the paper.

54 ENVIRONMENTAL SCIENCES↗