Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIB tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

54 records · Page 3

Argon Milling of Bulk and Post-FIB Specimens for Multi-Length Scale Analyses by EBSD, TEM, and APT under Controlled Environments

Correlative investigations involve structural characterization by transmission electron microscopy (TEM) combined with compositional analysis by atom probe tomography (APT) using the same specimen. A critical component of successful correlative analyses is specimen preparation; probing individual atoms requires a surface and subsurface with minimal defects, beginning with the bulk material through to the prepared specimen for TEM or APT analysis. Our previous work showed that low-energy concentrated ion beam Ar ion milling improves TEM [1] and APT [2,3] specimen quality by removing surface oxides and Ga damage caused by focused ion beam (FIB) preparation. Further enhancement in specimen quality of APT specimens is achieved in the established workflow under controlled environments, as shown in [4]. In this work, we present specimen preparation using Ar ion milling techniques not only for the APT specimen, but also the bulk sample for subsequent multi-length scale analyses by electron backscatter diffraction (EBSD), TEM, and APT under controlled environments. The removal of surface damage and oxidation, which is crucial for probing atomic layer specimens by broad and concentrated Ar ion beam milling techniques under controlled environments, is highlighted.

36 MATERIALS SCIENCE↗

Atom Probe characterization of neutron irradiated commercial ZIRLO® and AXIOM X2® alloys

As part of the Mechanistic Understanding of ZIrconium Corrosion (MUZIC) program, this team has been instrumental to obtain EPRI and Westinghouse sponsorships to prepare the neutron irradiated ZIRLO® and X2® from Vogtle nuclear power plant and ship them from Studsvik’s (Sweden) hot cells to Idaho National Laboratory (INL) to be part of the NSUF library. The uniqueness of these sets of neutron irradiated alloys is that they are at the same two extremes of the fuel cycles, allowing us to study the microchemistry evolution as a function of irradiation doses, exposure time and solute content. Advanced commercial Zirconium-Niobium (Zr-Nb) alloys, such as ZIRLO® and AXIOM®, have been developed by Westinghouse to enhance the corrosion resistance of fuel cladding material for longer service time. This study specifically aims at investigating the neutron irradiation induced Nb redistribution in AXIOM® X2® to understand the effect of neutron irradiation induced microchemistry changes and the irradiation enhanced corrosion resistance observed in ZrNb alloys. The detailed sample information on chemical composition and irradiation is given in shown in Table 1a and 1b respectively. To study the neutron IIP/nanoclusters and Nb concentration in the solid solution, atom probe tomography (APT) is the primary tool to obtain reliable chemical information. APT specimens were prepared in shielded focused ion beam (FIB) at the Irradiated Materials Characterization Laboratory (IMCL) at INL followed by APT analysis at CAES facility using LEAP 4000XR

36 MATERIALS SCIENCE↗

A reliable workflow for improving nanoscale X-ray fluorescence tomographic analysis on nanoparticle-treated HeLa cells

Abstract Scanning X-ray fluorescence (XRF) tomography provides powerful characterization capabilities in evaluating elemental distribution and differentiating their inter- and intra-cellular interactions in a three-dimensional (3D) space. Scanning XRF tomography encounters practical challenges from the sample itself, where the range of rotation angles is limited by geometric constraints, involving sample substrates or nearby features either blocking or converging into the field of view. This study aims to develop a reliable and efficient workflow that can (1) expand the experimental window for nanoscale tomographic analysis of local areas of interest within a laterally extended specimen, and (2) bridge 3D analysis at micrometer and nanoscales on the same specimen. We demonstrate the workflow using a specimen of HeLa cells exposed to iron oxide core and titanium dioxide shell (Fe3O4/TiO2) nanocomposites. The workflow utilizes iterative and multiscale XRF data collection with intermediate sample processing by focused ion beam (FIB) sample preparation between measurements at different length scales. Initial assessment combined with precise sample manipulation via FIB allows direct removal of sample regions that are obstacles to both incident X-ray beam and outgoing XRF signals, which considerably improves the subsequent nanoscale tomography analysis. This multiscale analysis workflow has advanced bio-nanotechnology studies by providing deep insights into the interaction between nanocomposites and single cells at a subcellular level as well as statistical assessments from measuring a population of cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extracellular filaments revealed by affinity capture cryogenic-electron tomography

Cryogenic-electron tomography (cryo-ET) has provided an unprecedented glimpse into the nanoscale architecture of cells by combining cryogenic preservation of biological structures with electron tomography. Micropatterning of extracellular matrix proteins is increasingly used as a method to prepare adherent cell types for cryo-ET as it promotes optimal positioning of cells and subcellular regions of interest for vitrification, cryo-focused ion beam (cryo-FIB) milling, and data acquisition. Here we demonstrate a micropatterning workflow for capturing minimally adherent cell types, human T cells and Jurkat cells, for cryo-FIB and cryo-ET. Our affinity capture system facilitated the nanoscale imaging of Jurkat cells, revealing extracellular filamentous structures. It improved workflow efficiency by consistently producing grids with a sufficient number of well-positioned cells for an entire cryo-FIB session. Affinity capture can be extended to facilitate high-resolution imaging of other adherent and non-adherent cell types with cryo-ET.

Biochemistry↗

A New Coordinated NanoSIMS, Transmission Electron Microscopy and Atom Probe Tomography Approach For the Characterization of Primitive Astromaterials

Presolar grains are remnants of evolved stellar systems preserved within primitive extraterrestrial materials. They are important for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium, Solar Nebula and their parent stellar environments [1]. Our recent work has shown coordinated nano-scale Secondary Ion Mass Spectrometry (NanoSIMS) and Atom Probe Tomography (APT) can show isotopic and chemical signatures at major to trace levels, morphological signatures, and regional contextual relationships [2,3]. Previous studies have shown Transmission Electron Microscopy (TEM) of Focus Ion Beam (FIB) TEM lamella, can provide localized contextual relationships, crystallographic information and chemical information [1]. Coordinating NanoSIMS, TEM, and APT could gain access to almost all contextual, structural and geochemical signatures within each presolar grain. However, this has proved challenging owing to the preparation requirements for TEM and APT. For example, studying specimen prepared as APT needles in TEM removes the local context, the higher degree of surface exposure can alter the chemistry of beam sensitive materials, and the shank angle of the needle can impact the quality of TEM diffraction images. We designed a new FIB method which takes a 100 nm thick FIB-TEM lamella and sandwiches it between two indium slices (5 μm x ~300 nm x 3 μm). The indium is melted onto the lamella surface using the electron beam (Fig 1). This process adds bulk to the lamella, making it more amenable to APT needle formation (Fig 2). Consequently, samples can be prepared per the optimal requirements for each technique improving data quality, acquisition stability, and access to the signatures and relationships summarised earlier. This technique can be used for measuring multiple phases across a TEM lamella and targeting an individual phase. For example, a presolar grain identified in NanoSIMS could be targeted, studied in TEM and then indium sandwiched with its precise location in the TEM lamella marked using a Pt button for preparation of an APT needle and atomic scale acquisition. [1] A. M. Davis (2014) Meteorites and cosmochemical processes, 1. [2] Nevill N. et al. (2023) LPSC, 54, #1707. [3] Nevill N. et al. (2023) LPSC, 54, #1714.

NanoSIMS↗

4D Imaging of ZnO-Coated Nanoporous Al 2 O 3 Aerogels by Chemically Sensitive Ptychographic Tomography: Implications for Designer Catalysts

The 3D chemical structure (4D spectromicroscopy) of nanoporous Al 2 O 3 aerogels coated with ZnO by atomic layer deposition (ALD) was studied by multienergy scanning transmission X-ray microscopy. These materials are representative of a class of designer catalysts in which the nanoporous support is prepared separately from the active catalyst material, which is subsequently introduced by ALD, thereby allowing independent optimization of the morphology, chemistry, and spatial distribution of the support and catalyst. The samples studied were prepared by Ga ion and Xe plasma focused ion beam (FIB) milling as well as drop casting from water suspension. Zn L and Al K edge spectra of six samples with three different ZnO loadings were measured to investigate how loading and different sample preparation methods affect the 3D distribution of the ZnO and Al 2 O 3 . Scanning transmission X-ray microscopy (STXM) and ptychographic imaging at two energies each at the Zn L 3 and Al K edge were measured. The ptychography data were analyzed by using the SHARP reconstruction code to generate quantitative 2D chemical maps of the Al 2 O 3 and the ZnO. The STXM and ptychography maps were then measured at a sequence of tilt angles, covering up to 160° of rotation. The 3D structure of the ZnO and Al 2 O 3 was derived from the tilt series data by tomographic reconstruction using a compressed sensing algorithm. A twodimensional spatial resolution (half-period) of 6 nm, measured by Fourier ring correlation, and a 3D spatial resolution (half-period) of 9 nm, measured by Fourier shell correlation, were achieved when using the COSMIC beamline at the Advanced Light Source (ALS). The results show that for all of the ZnO loadings studied there is nonuniform coverage of the ZnO on the Al 2 O 3 aerogel framework. In addition, we found that both FIB methods create sample artifacts, although the distortion was less with Xe plasma than Ga ion FIB.

36 MATERIALS SCIENCE↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Impacts of Focused Ion Beam Processing on the Fabrication of Nanoscale Functionalized Probes

Herein, we examine the impact of Ga + ion kinetic energy and the target material type on the extent of ion implantation and structural damage in atomic force microscopy probes made of Al 2 O 3 and ZnO manufactured by focused ion beam (FIB) using scanning transmission electron microscopy and energy-dispersive X-ray mapping. Penetration of Ga into the Al 2 O 3 lattice induced structural distortions and amorphization. For ZnO probes, Ga is uniformly dispersed across the surface, resulting in the formation of distinct clusters. Atom probe tomography further validates the Ga distributions in Al 2 O 3 and ZnO nanoprobes. Complementary Monte Carlo simulations with the transport of ions in the matter program indicated that the introduction of Ga + prompts the generation of cation and anion vacancies, an occurrence more pronounced in Al 2 O 3 compared to ZnO. In conclusion, this study not only enriches the knowledge of ion-matter interactions, but also serves as a practical guide for the fabrication of nanoscale functionalized AFM probes.

Al2O3↗

Four-dimensional microstructurally small fatigue crack growth in cyclically loaded nickel superalloy specimen

Here, we nondestructively image a low-solvus high refractory (LSHR) nickel base specimen microstructure during cyclic loading to characterize crack propagation during the microstructurally small crack (MSC) growth regime. Micro-computed tomography (uCT) is used to characterize the material density and identify crack interfaces, while high-energy diffraction microscopy (HEDM) provides snapshots of the microstructural orientation field changes. From these measurements, data are computationally reconstructed and coregistered to describe the specimen’s configuration before load, before crack nucleation, and throughout the crack propagation/loading process. An MSC forms at a FIB-cut notch, which was previously placed to concentrate stress at the center of the specimen gauge, and propagates along a facet parallel to the local {1 1 1} crystallographic plane. Analysis of available crystallographic slip directions and measured point-to-point disorientation axes indicate probable single and coplanar slip activity along FCC octahedral planes within this region. Similar analyses of other crack propagation facets reveal generally slower growth along directions favoring zig-zag cross and codirectional cross slip, which are often disfavored at room temperature.

36 MATERIALS SCIENCE↗

Origin of the enhanced Nb3Sn performance by combined Hf and Ta doping

Abstract In recent years there has been an increasing effort in improving the performance of Nb 3 Sn for high-field applications, in particular for the fabrication of conductors suitable for the realization of the Future Circular Collider (FCC) at CERN. This challenging task has led to the investigation of new routes to advance the high-field pinning properties, the irreversibility and the upper critical fields ( H Irr and H c2 , respectively). The effect of hafnium addition to the standard Nb-4Ta alloy has been recently demonstrated to be particularly promising and, in this paper, we investigate the origins of the observed improvements of the superconducting properties. Electron microscopy, Extended X-ray Absorption Fine Structure Spectroscopy (EXAFS) and Atom Probe Tomography (APT) characterization clearly show that, in presence of oxygen, both fine Nb 3 Sn grains and HfO 2 nanoparticles form. Although EXAFS is unable to detect significant amounts of Hf in the A15 structure, APT does indeed reveal some residual intragrain metallic Hf. To investigate the layer properties in more detail, we created a microbridge from a thin lamella extracted by Focused Ion Beam (FIB) and measured the transport properties of Ta-Hf-doped Nb 3 Sn. H c2 (0) is enhanced to 30.8 T by the introduction of Hf, ~ 1 T higher than those of only Ta-doped Nb 3 Sn, and, even more importantly the position of the pinning force maximum exceeds 6 T, against the typical ~ 4.5–4.7 T of the only Ta-doped material. These results show that the improvements generated by Hf addition can significantly enhance the high-field performance, bringing Nb 3 Sn closer to the requirements necessary for FCC realization.

36 MATERIALS SCIENCE↗

Probing Heterogeneity in Bovine Enamel Composition through Nanoscale Chemical Imaging using Atom Probe Tomography

Objective: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. Design: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). The samples were then analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. Results: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ~1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. Conclusion: In conclusion, the presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.

59 BASIC BIOLOGICAL SCIENCES↗

Atom Probe Tomography Investigation of Clustering in Model P 2 O 5 -Doped Borosilicate Glasses for Nuclear Waste Vitrification

Atom probe tomography (APT) has been utilized to investigate the microstructure of two model borosilicate glasses designed to understand the solubility limits of phosphorous pentoxide (P 2 O 5 ). This component is found in certain high-level radioactive defence wastes destined for vitrification, where phase separation can potentially lead to a number of issues relating to the processing of the glass and its long-term chemical and structural stability. The development of suitable focused ion beam (FIB)-preparation routes and APT analysis conditions were initially determined for the model glasses, before examining their detailed microstructures. In a 3.0 mol% P 2 O 5 -doped glass, both visual inspection and sensitive statistical analysis of the APT data show homogeneous microstructures, while raising the content to 4.0 mol% initiates the formation of phosphorus-enriched nanoscale precipitates. This study confirms the expected inhomogeneities and phase separation of these glasses and offers routes to characterizing these at near-atomic scale resolution using APT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Method of Absorption-Phase Nanotomography for 3D Observation of Mineral-Organic-Water Textiles and its Application to Pristine Carbonaceous Chondrites

Pristine carbonaceous chondrites contain fine-grained matrix, which is composed largely of amorphous silicates, sub-micron silicate and sulfide crystals, and organic materials. They are regarded as primitive dust in the early Solar System that have suffered minimal alteration in their parent bodies. The matrix generally has different lithologies; some of them are unaltered but some are more or less aqueously altered. Their textures have been examined in 2D usually by FE-SEM/EDS, TEM/EDS, nano-SIMS and micro-XRD. Observation of their complex fine textures, such as spatial relation between different lithologies in 3D, is important for understanding aggregation and alteration processes. Synchrotron radiation (SR)-based X-ray tomography reveals 3D structures nondestructively with high spatial resolution of approximately greater than 100 nm. We have developed a new technique using absorption contrasts called "dual-energy tomography" (DET) to obtain 3D distribution of minerals at SPring-8, SR facility in Japan, and applied successfully to Itokawa particles. Phase and absorption contrast images can be simultaneously obtained in 3D by using "scanning-imaging x-ray microscopy" (SIXM) at SPring-8, which can discriminate between void, water and organic materials. We applied this technique combined with FIB micro-sampling to carbonaceous chondrites to search for primitive liquid water. In this study, we combined the DET and SIXM to obtain three dimensional submicron-scale association between minerals, organic materials and water and applied this to pristine carbonaceous chondrites.

Tsuchiyama, A.↗

Optical Interference for the Guidance of Cryogenic Focused Ion Beam Milling Beyond the Axial Diffraction Limit

Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labelled structures with accuracy beyond the diffraction limit. We demonstrate the approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of water. Here, we then apply the approach to capture virions inside host cells. Successful targeting is confirmed by cryogenic electron tomography revealing clusters of virions in intracellular vesicles.

Sica, Anthony V. [SLAC National Accelerator Labora↗

Visualizing defects and pore connectivity within metal–organic frameworks by X-ray transmission tomography

Metal–Organic Frameworks (MOFs) have the potential to change the landscape of molecular separations in chemical processes owing to their ability of selectively binding molecules. Their molecular sorting properties generally rely on the micro- and meso-pore structure, as well as on the presence of coordinatively unsaturated sites that interact with the different chemical species present in the feed. In this work, we show a first-of-its-kind tomographic imaging of the crystal morphology of a metal– organic framework by means of transmission X-ray microscopy (TXM), including a detailed data reconstruction and processing approach. Corroboration with Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM) images shows the potential of this strategy for further (non-destructively) assessing the inner architecture of MOF crystals. By doing this, we have unraveled the presence of large voids in the internal structure of a MIL-47(V) crystal, which are typically thought of as rather homogeneous lattices. This challenges the established opinion that hydrothermal syntheses yield relatively defect-free material and sheds further light on the internal morphology of crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Compositional Mapping of Commercial LiNi 0.8 Co 0.15 Al 0.05 O 2 Cathodes Using Atom Probe Tomography

Nickel-rich cathodes provide improved specific capacity that lead to higher gravimetric energy density, critical for electric vehicles. However, poor long-term capacity retention at elevated temperatures/high C-rates (the rate of charge and discharge on a battery) stem from material issues: surface phase changes, corrosive side reactions with the electrolyte, ion dissolution and propagation of cracks. Introducing dopants, developing nanoscale surface coatings and graded core-shell structures have all improved the electrochemical performance of nickel-rich cathodes. However, a material level understanding on the effect of Li composition and distribution in Ni-rich cathodes is limited, due to a lack of characterization methods available that can directly image Li at the nanoscale. Hence, it is critical to establish methods such as atom probe tomography (APT), having both nanometer scale spatial resolution and high compositional sensitivity to quantitatively analyze battery cathodes. To fully realize its potential as a method for quantitative compositional analysis of commercial Li-ion batteries, we provide a comprehensive description of the challenges in sample preparation and analyze the dependency of the analysis parameters, specifically laser pulse energy on the measured stoichiometry of elements in a high Ni content cathode material; LiNi 0.8 Co 0.15 Al 0.05 O 2 (NCA). In this work, our findings show the stoichiometry variations cannot be explained by charge state ratios or Ga implantation damage alone during FIB preparation, indicating that additional factors such as crystallographic orientation may need to be considered to achieve quantitative nanoscale compositional analysis of such battery cathodes using APT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3-D-Observation of Matrix of MIL 090657 Meteorite by Absorption-Phase Tomography

MIL 090657 meteorite (CR2.7) is one of the least altered primitive carbonaceous c hondrites [1]. This meteorite has amorphous silicates like GEMS (glass with embedded metal and sulfide), which are characteristically contained in cometary dust, in matrix [2,3] as with the Paris meteorite [4]. Three lithologies have been recognized; lithology-1 (L 1) dominated by submicron anhydrous silicates, lithology-2 (L2) by GEMS-like amorphous silicates and lithology-3 (L3) by phyllosilicates [2]. Organic materials are abundant in L 1 and L2 [2,3]. L 1 and L2 were further divided into sub-lithology respectively based on their textures and compositions [5]. These studies were performed by 2D SEM and TEM observations of sample surfaces and thin sections that are unable to reveal what constitute each lithology and how these lithologies are distributed and related to each other. This information will provide important insights into alteration and aggregation processes on asteroids and in the early solar nebula. In this study, MIL 090657 matrix was examined in 3D using two types of X-ray tomography; DET (dual-energy tomography) [6] and SIXM (scanning-imaging X-ray microscopy) [7]. Mineral phases can be discriminated based on absorption contrasts at two different X-ray energies in DET. In SIXM, materials composed of light elements such as water or organic materials can be identified based on phase and absorption contrasts. By combining these methods, we can discriminate not only organic materials from voids but also hydrous alteration products, such as hydrated silicates and carbonates, from anhydrous minerals [8]. In this study, we first observed cross sections of MIL 090657 matrix fragments C1 00 mm) in detail using FE-SEM/ EDS. Based on the results, three house-shaped samples (3 0 -50 mm) were extracted from L 1, L2 and their boundary (H1, H3 and H5, respectively) using FIB. 3D imaging of these samples were conducted at BL47XU of SPring-8, a synchrotron radiation facility, with -30-40 nm/ voxel and - 70-80 nm/ voxel at 7keV and 8keV in DET and -100 nm/ voxel at 8keV in SIXM. We found new lithologies that we named L4, L5 and L6 in H1 and H3 in addition to L 1 and L2. L4. L5 and L6 are mainly composed of probably phyllosilicates with different Fe contents. Sulfide and framboidal magnetite were recognized in L4. L5 includes magnetite and carbonate and L6 includes anhydrous silicates having cracks inside. L 1, L2, L4 and L5 are porous while few voids were observed in L6. L4 adjoins to L 1 with boundary, which is not very distinct. L2, L5 and L6 adjoin to each other, and the boundaries of L6 with L2 and L5 are clear. In H5, coarse mineral grains C5-1 0 mm) such as Fe-metal and enstatite are present in L 1 and L2. L 1-L2 boundary is not sharp in 3 D. In conclusion, we found a variety of lithologies by 3D observation for the first time, suggesting that t he MIL 0 90657 meteorite experienced complex alteration and aggregation histories. As L2 is dominated by amorphous silicates, which are extremely susceptible to aqueous alteration, t his is p resumed to be t he most primitive lithology. The contact between L2 and phyllosilicate-bearing lithologies (L5 and L6) with clear boundaries indicates that they were aggregated after aqueous alteration of L5 and L6. The indistinct boundary between L 1 and L2 is suggesting that these two lithologies might originally be the same aggregate composed of amorphous silicates and coarse mineral grains. L 1 might have experienced weak aqueous alteration followed by mild thermal alteration [2], while L2 did not undergo aqueous alteration.

Miyama, Sugimoto↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗