Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimized Gear Selection to Maximize Energy Savings in Electric Traction Drives for Medium and Heavy Duty Vehicles

Multi‑gear transmission systems are commonly used in electric traction drives for medium and heavy‑duty vehicles, while most passenger‑vehicle electric drivetrains rely on a single fixed ratio to reduce cost, weight, and complexity. Using multiple gear ratios can enable downsizing of the motor and inverter while still meeting performance requirements. Additionally, appropriately chosen ratios allow the motor to operate more frequently in high‑efficiency regions, improving overall energy usage and reducing operating costs over the drive cycle. This paper presents a systematic approach for selecting optimal gear ratios for electric drive systems. A neural‑network model is first developed to represent motor losses across the full torque–speed range using data generated from finite element analysis. This model enables fast, accurate evaluation of motor efficiency under varying operating conditions. A genetic‑algorithm‑based optimization framework is then applied to identify gear ratios that maximize energy cost savings over the drive cycle, with the resulting optimal ratios stored for real‑time implementation.

Gadiyar, Nishanth [ORNL] (ORCID:0000000348267524)↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Nanoporous Wood Chips Based Sizable, Robust, and Low-Cost Honeycomb Vacuum Insulation Panels (DOE BENEFIT Final Research Performance Progress Report (RPPR))

Conventional vacuum insulation panels (VIPs) suffer from severe limitations including high cost, vulnerability to perforation, and significant performance degradation over time due to vacuum loss. InventWood Inc. (IW) and partnering teams completely re-engineered the VIP structure by constructing arrays of isolated vacuum-cells to enable limited cutting at designated areas (in between vacuum cells) and reduced consequential vacuum loss due to puncture. The teams also replaced the expensive vacuum insulation core materials with a low-cost commercial wood pulp and recycled long fiber. The wood pulp derived VIP can deliver an overall panel insulation of R15 (<0.01W/m·K) with over 90% thermal resistance retention after cutting (R13.5 overall, R5 along the cut edges). In addition, the vacuum-cell-array design minimizes edge losses, resulting in more durable performance, longer service life (>50 years), and higher R-value per dollar towards a cost target of <$1/ft 2 ·in. It is anticipated that the Nanochip-VIP will attract strong market interest and become an affordable insulation solution for energy efficient buildings and retrofits, leading to significant reductions in energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainability and affordability of building electrification: A state-by-state holistic approach for multifamily buildings

This paper explores the evolving narrative of building electrification, considering its potential to solve climate change. Previous research has predominantly focused on hybrid renewable energy portfolios and increasing home pricing premiums, overlooking the perspectives of renters burdened by housing costs. Moreover, existing studies have primarily examined the effects of electrification on single-family homes and case studies, neglecting multifamily buildings and their relationship with the grid. This comprehensive study leverages calibrated building energy models to address these gaps and evaluates sustainability through carbon dioxide emissions and affordability through economic performance. The findings demonstrate significant progress in electrification since 2017, with nearly all states showing decreased energy usage in the electrified models. Environmentally, twenty-two states perform better or comparably with the electrified models in the most recent study. Economically, challenges persist, but a sensitivity analysis demonstrates how results could improve soon. Furthermore, the study discusses the outlook of electrified multifamily buildings, considering ongoing decarbonization plans for the electric grid. In three case studies, electrification demonstrates improvements in over half of the states by 2026. Overall, the research highlights the importance of expanding analysis to include multifamily buildings and emphasizes the positive impact of electrification as a viable energy, environmental, and economic solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Evolving Role of Demand Charges in Retail Electricity Rates

Retail electricity demand charges refer to a type of retail rate that is based on a metric of kilowatt (kW) demand rather than kilowatt-hour (kWh) energy usage. Demand charges are widely used in the commercial and industrial (C&I) electricity sectors to recover significant portions of utility revenue and are also used in residential rates in a modest but growing number of locations. This paper explores the historical context of and motivations for demand charges, describes their implementation and impacts in today's context, and uses a variety of opinions collected from relevant parties through semi-structured interviews to inform how demand charges align with four widely accepted rate design principles. This project is funded by the Department of Energy's Office of Electricity, which is interested in conducting research to understand the current state of affairs related to demand charges and how the future U.S. electricity grid will help to define retail rates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Self-Healing Films for Vacuum Insulation Panels (Final Report)

Vacuum insulation panels (VIPs) have an extremely high thermal resistance of around R35/inch, which makes them ideal for building envelope retrofits and prefabricated construction with space constraints. However, the barrier film that maintains the vacuum and thermal performance of the panel can be easily damaged during transportation, installation, and service life. Oak Ridge National Laboratory (ORNL) has developed a self-healable barrier film for VIPs that instantly self-heals damages caused by punctures. The multi-layer barrier film is manufactured using roll-to-roll (R2R) methods. The self-healing barrier film prevents loss of vacuum in VIPs and maintains the exceptional thermal insulation performance. Enhanced durability of VIP by self-healable barrier film and establishing the commercialization path will increase the use of VIPs, thus reducing overall energy usage of buildings. This project has fine-tuned the slurry chemistry of the self-healing components and transitioned the R2R manufacturing trials from mid-scale lab equipment to large-scale industrial equipment for de-risking the technology for commercialization with our TCF CRADA partner, FLEXcon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Green Button Extensibility Assessment

In September 2011, the federal government announced a “call to action” to create a mechanism to enable utility consumers to download their energy usage history from their utilities’ secure websites in a standardized electronic format. That effort was christened the Green Button initiative, drawing on the success of the Blue Button initiative delivered by the US Department of Defense in 2009 as a secure, online access mechanism to download patient health information through the TriCare online portal.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bicarbonate-Carbonate Selectivity through Nanofiltration for Direct Air Capture of Carbon Dioxide

Direct air capture (DAC) of carbon dioxide is one approach among many proposed that is capable of offsetting hard-to-avoid emissions. In previous work, we developed the alkalinity concentration swing (ACS) method, which is driven through concentrating an alkaline solution that has been loaded with atmospheric CO 2 by desalination technologies, such as reverse osmosis or capacitive deionization. Though the ACS is promising in terms of energy usage and implementation, its absorption rate and water requirements are infeasible for a large-scale DAC process. Here, we propose an improvement on the ACS, the bicarbonate-enriched alkalinity concentration swing (BE-ACS), which selects bicarbonate ions from a stream of aqueous alkaline solution that has absorbed atmospheric CO 2 . The bicarbonate-rich stream is then concentrated, which greatly increases its CO 2 partial pressure, and then CO 2 is extracted from solution. We experimentally investigate the use of pressure-driven nanofiltration (NF) membrane-based separation to select bicarbonate ions over carbonate ions. We screen commercial membranes and select one high-performance membrane for detailed studies, quantifying its bicarbonate-carbonate selectivity factor and bicarbonate-passage factor. Feed pH, the combined concentration of aqueous CO 2 , bicarbonate, and carbonate species (or dissolved inorganic carbon), alkalinity, and permeation flux are systematically varied to study NF separation properties. We find that the selectivity factor, which exceeds 30 times in certain regimes, increases with higher feed pH and higher alkalinity. Lastly, the performance metrics of the selected NF membrane are input into a theoretical BE-ACS cycle analysis, and the required energy input and cycle capacity output are evaluated. Ideal cycle energy is found to be as low as around 250 kJ/mol, with opportunities identified for further decreases through process engineering and forward osmosis energy recovery.

animal feed↗

Inferring building height from footprint morphology data

As cities continue to grow globally, characterizing the built environment is essential to understanding human populations, projecting energy usage, monitoring urban heat island impacts, preventing environmental degradation, and planning for urban development. Buildings are a key component of the built environment and there is currently a lack of data on building height at the global level. Current methodologies for developing building height models that utilize remote sensing are limited in scale due to the high cost of data acquisition. Other approaches that leverage 2D features are restricted based on the volume of ancillary data necessary to infer height. Here, we find, through a series of experiments covering 74.55 million buildings from the United States, France, and Germany, it is possible, with 95% accuracy, to infer building height within 3 m of the true height using footprint morphology data. Our results show that leveraging individual building footprints can lead to accurate building height predictions while not requiring ancillary data, thus making this method applicable wherever building footprints are available. The finding that it is possible to infer building height from footprint data alone provides researchers a new method to leverage in relation to various applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Silicon Impurity on the Hydrometallurgical Recovery of NCM622 Cathode

Hydrometallurgy is one of the best approaches to date for recycling LIBs due to its high efficiency, low energy usage, and industrial scalability. However, impurities have always been a thorny issue because they could have unintended impacts on the recovered cathode materials. This research marks the first systematic investigation into the influence of silicon impurity on the LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622) cathode obtained from hydrometallurgical recycling. Here we find that silicon nanoparticles will be nucleated at the center of the precursor particles during co-precipitation synthesis, and the silicon core will slowly dissolve in the surrounding ammonia, creating a special hollow structure in the particle. More importantly, the dissolution of silicon impurity will eventually lead to the deposition of silicates in the cathode material, which is an unfavorable result. Test data indicate that NCM622 cathode with 5 at% silicon has a capacity of 148.8 mAh g −1 after 100 cycles at 1/3 C, approximately 10 mAh g −1 lower than the virgin. Despite being relatively mild, the adverse influence of silicon impurity in hydrometallurgical recycling still requires attention.

25 ENERGY STORAGE↗