Enclosure fire modeling

A fire characterization methodology is presented, which for the first time provides a unified analysis framework for the integration of all fire tests data on a common basis. Fire temperatures, smoke densities, toxic gas concentrations and heat fluxes to material properties, enclosure geometry, and ventilation factors are provided in this fire characterization approach. The fire characterization methodology was used to develop an enclosure fire hazards analysis procedure capable of predicting the probable course in fire prevention.

Coulbert, C. D.↗

Enclosure fire dynamics model

A practical situation of an enclosure fire is presented and why the need for a fire dynamic model is addressed. The difficulties in establishing a model are discussed, along with a brief review of enclosure fire models available. The approximation of the practical situation and the model developed are presented.

Bellan, J.↗

Transient natural and surface-tension-driven convection in a two-layer gas-and-liquid enclosure with nonuniform radiative transfer

A numerical study has been made of transient heat transfer and fluid flow in a cylindrical enclosure containing a two-layer gas-and-liquid system. The geometric configuration and the boundary conditions of the problem are relevant to the analysis of the preignition processes during the fire accident situation involving a pool of liquid fuel in the vicinity of an ignition source. It is demonstrated that the effects of the natural and thermocapillary convection, radiative transfer, thermal inertia and conduction of the walls bounding the enclosure, as well as, the magnitude of the gravity field play important roles in the development of the temperature and velocity fields in the container.

Abramzon, B.↗

Diffusive-convective vapor transport across horizontal and inclined rectangular enclosures

The enhancement of vapor transport across horizontal and inclined rectangular (two-dimensional) enclosures by expansive convection is studied numerically for a range in Grashof number that extends up to boundary layer flow. Comparison is made with predictions of the simplifying model and resulting analytical treatment of Klosse and Ullersma (1973) for various aspect ratios of the enclosure. The influence of varying Schmidt and Prandtl numbers is investigated. Solutions for interfacial (growth) flux and temperature distributions are given, showing practically important nonuniformities.

Markham, B. L.↗

Radiative and free-convective heat transfer from a finite horizontal plate inside an enclosure

An experimental and analytical investigation of heat transfer from a horizontal, thin, square plate inside of an enclosure was carried out. Experimental results were obtained from both the upward-facing and the downward-facing sides of the heated plate. Starting with the integrated momentum and energy equations, approximate solutions were obtained for heat transfer in the laminar and the turbulent regime that correlate well with experimental data. Radiative heat transfer correction was given special attention. Effects of the enclosure-related recirculation of the test fluid, as well as effects of simultaneous heat transfer on both sides of the plate, caused an early transition, and indicated a high level of internal turbulence.

Hrycak, Peter↗

A new analysis of beam-waveguide antennas considering the presence of the enclosure

Beam-waveguide (BWG) antennas provide multiple frequency band operations and other operational benefits for large ground-station antennas. Present design practices use diffraction analyses that ignore the presence of the BWG enclosure and may be inaccurate at lower frequency bands for ground-station antennas operating over multiple frequency bands. Introduced here is a new analysis approach that considers the presence of the BWG enclosure. Results based on the new analysis have revealed new understandings of the performance degradation mechanisms in a BWG antenna and have provided direction for potential design improvements.

Cha, A. G.↗

Ground-based experiments on thermal and thermosolutal convection in inclined low-aspect-ratio enclosures

Thermal and thermosolutal convection driven by buoyancy forces are investigated experimentally in inclined low-aspect-ratio enclosures. Thermal and thermosolutal convection are important in crystal growth processes. The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. The present work is concerned with natural convection in a shallow rectangular enclosure with imposed inclined temperature and/or concentration gradients. Various complex flow patterns are observed with different experimental conditions. A flow instability under certain conditions is reported. The flow instability is found to depend not only on the thermal and solutal Grashof numbers, the aspect ratios, but also the inclined angles.

Wang, L. W.↗

Rapidly Deployable Enclosure

Balloons expand to surround and seal off equipment. Housing of undeployed enclosure encircles equipment to be enclosed. Deployed enclosure surrounds equipment and seals it from environment. Fully deployed within few seconds. Conceived to shield rocket booster from ocean water when dropped after launching spacecraft, adapted to suit terrestrial equipment that must be shielded quickly against impending immersion.

Rournier, Walter L.↗

Hubble Space Telescope servicing mission scientific instrument protective enclosure design requirements and contamination controls

The Scientific Instrument Protective Enclosures were designed for the Hubble Space Telescope Servicing Missions to provide a beginning environment to a Scientific Instrument during ground and on orbit activities. The Scientific Instruments required very stringent surface cleanliness and molecular outgassing levels to maintain ultraviolet performance. Data from the First Servicing Mission verified that both the Scientific Instruments and Scientific Instrument Protective Enclosures met surface cleanliness level requirements during ground and on-orbit activities.

Hansen, Patricia A.↗

A case study of view-factor rectification procedures for diffuse-gray radiation enclosure computations

The view factors which are used in diffuse-gray radiation enclosure calculations are often computed by approximate numerical integrations. These approximately calculated view factors will usually not satisfy the important physical constraints of reciprocity and closure. In this paper several view-factor rectification algorithms are reviewed and a rectification algorithm based on a least-squares numerical filtering scheme is proposed with both weighted and unweighted classes. A Monte-Carlo investigation is undertaken to study the propagation of view-factor and surface-area uncertainties into the heat transfer results of the diffuse-gray enclosure calculations. It is found that the weighted least-squares algorithm is vastly superior to the other rectification schemes for the reduction of the heat-flux sensitivities to view-factor uncertainties. In a sample problem, which has proven to be very sensitive to uncertainties in view factor, the heat transfer calculations with weighted least-squares rectified view factors are very good with an original view-factor matrix computed to only one-digit accuracy. All of the algorithms had roughly equivalent effects on the reduction in sensitivity to area uncertainty in this case study.

Taylor, Robert P.↗

Safety-Enclosure System For MOCVD Process Chamber

Safety-enclosure system filled with nitrogen surrounds reaction chamber in which metallo-organic chemical vapor deposition (MOCVD) performed. Designed to protect against explosions and/or escaping toxic gases and particulates. Gas-purification subsystem ensures during loading and unloading of process materials, interior of MOCVD chamber exposed to less than 1 ppm of oxygen and less than 5 ppm of water in nitrogen atmosphere. Toxic byproducts of MOCVD process collected within inert atmosphere. Enclosure strong enough to contain any fragments in unlikely event of explosion.

Singletery, James, Jr.↗

Heat dissipation in controlled environment enclosures through the application of water screens

The use of plate glass-water thermal barriers in controlled environment facilities effectively reduces the thermal load within the plant growth chamber. This allows high PPFs to be provided for plant growth and development studies, adequate simulation of daily light integrals, and simulation of peak PPF's. Further, substantial amounts of incandescent lamp supplementation can be used to achieve simulation of daylight R:FR ratios which are needed to ensure adequate stem development in some species. While the focus in this paper is on the use of entire thermal barriers which separate the lighting enclosure from the plant growth chamber, the same principles apply to the use of water jackets for cooling individual lamps (such as can occur with xenon-arc lamps). In this instance, the barrier separating the lamps from the plant chamber can be much simpler (e.g., plexiglass) as the main function of the barrier is to separate the air ventilation of the lamp enclosure from the air system within the plant growth chamber. The main advantage of water as a thermal barrier is the negligible absorption of radiation in the photosynthetically-active and near infrared wavebands. Consequently, plate glass-water barriers typically allow transmission of approximately 90% of radiation in these regions. While ventilated double and triple glazing systems appear to be attractive alternative to water barriers from an operating standpoint, their significant absorption in the biologically-important wavebands (7 - 12%) with each glass layer and longer-wave cut-offs (typically 2500 - 4000 nm) makes them a much less attractive alternative. The data presented here demonstrate clearly that measurement of PPF alone is not an adequate representation of the radiation environment being used in a controlled environment study. The amounts and proportions of long-wave and short-wave radiation in a plant growth chamber are dependent on lamp type, lamp combination, presence of a thermal barrier, the type of thermal barrier between the lamps and the plant growing area and the overall construction and design of the chamber. It is important, therefore, in reporting results of controlled environment studies, to adequately describe both the details of the lighting system used and the characteristics of the radiation produced by that system, so results of different studies can be adequately evaluated and compared.

Warrington, I. J.↗

The Development of Lightweight Electronics Enclosures for Space Applications

This paper outlines the end to end effort to produce lightweight electronics enclosures for NASA GSFC electronics applications with the end goal of presenting an array of lightweight box options for a flight opportunity. Topics including the development of requirements, design of three different boxes, utilization of advanced materials and processes, and analysis and test will be discussed. Three different boxes were developed independently and in parallel. A lightweight machined Aluminum box, a cast Aluminum box and a composite box were designed, fabricated, and tested both mechanically and thermally. There were many challenges encountered in meeting the requirements with a non-metallic enclosure and the development of the composite box employed several innovative techniques.

Fenske, Matthew T.↗

The Development of Lightweight Electronics Enclosures for Space Applications

This paper outlines the end to end effort to produce lightweight electronics enclosures for NASA GSFC electronics applications with the end goal of presenting an array of lightweight box options for a flight opportunity. Topics including the development of requirements, design of three different boxes, utilization of advanced materials and processes, and analysis and test will be discussed. Three different boxes were developed independently and in parallel. A lightweight machined Aluminum box, a cast Aluminum box and a composite box were designed, fabricated, and tested both mechanically and thermally. There were many challenges encountered in meeting the requirements with a non-metallic enclosure and the development of the composite box employed several innovative techniques.

Fenske, Matthew T.↗

Effects of artificial enclosure of young lettuce leaves on tipburn incidence and leaf calcium concentration

The young developing leaves of 20-day-old lettuce plants (Lactuca sativa L. 'Buttercrunch') were enclosed by aluminized polyethylene sheaths to decrease transpiration and reduce Ca transport. The plants were grown in recirculating solution culture system using a modified half-strength Hoagland's solution under cool-white fluorescent lamps with a photosynthetic photon flux of 350 micromoles s-1 m-2 in a 16:8-hr (light:dark) period. Air temperature and humidity were 20 degrees C and 65%, respectively. After 4 days of enclosure, 53% of the inner leavers (leaves one to 3 cm in length) were tipburned. After the same period, less than 1% of the inner leaves on control plants were tipburned. The concentration of Ca in enclosed inner leaves was 0.63 mg g-1 dry weight, compared to 1.48 mg g-1 dry weight in inner leaves that were not enclosed. The Ca concentration in transpiring outer leaves of all plants was 9.9 mg g-1 dry weight. The Mg concentration in enclosed inner leaves was 2.25 mg g-1 dry weight, compared to 2.34 mg g-1 dry weight in inner leaves that were not enclosed. This research documents that enclosures of leaves at the growing point, as would occur with normal head development, is sufficient to create a limiting concentration of Ca in the enclosed tissue and encourage tipburn development.

Non-NASA Center↗

Evaluate Techniques for Penetrating a Shielded Enclosure Using Twisted Pair Wire

The aim of this project is to demonstrate techniques for effectively penetrating a radio shielded enclosure using Ethernet cable (CAT-6). This process requires that we measure the shielding performance by means of testing and data orchestration to collect and analyze our data to present observations with different test cases. Each test case would represent a different penetration strategy that utilizes distinctive wire coupling and characteristics (i.e. the type of bulkhead link, the twist of each CAT-6 cable, the shielding type of each CAT-6 cable, and the length of the cable). As the different cable setups are fabricated a prototype evaluation of setup is conducted to measure the signal integrity of our testing configuration. Our signal integrity is measured through the analysis of different parameters found in the prototype evaluation such as RF leakage, impedance mismatch, and decay rate. As each of these data values are effectively collected and analyzed the most effective cable setup is selected based upon its ability to penetrate the shielded enclosure. The testing data is compared in conjunction with the cost of the manufacturing of the prototype wire penetration.

St. Julian, Christopher↗

Canonical Statistical Model for Maximum Expected Immission of Wire Conductor in an Aperture Enclosure

Prediction of the maximum expected electromagnetic pick-up of conductors inside a realistic shielding enclosure is an important canonical problem for system-level EMC design of space craft, launch vehicles, aircraft and automobiles. This paper introduces a simple statistical power balance model for prediction of the maximum expected current in a wire conductor inside an aperture enclosure. It calculates both the statistical mean and variance of the immission from the physical design parameters of the problem. Familiar probability density functions can then be used to predict the maximum expected immission for deign purposes. The statistical power balance model requires minimal EMC design information and solves orders of magnitude faster than existing numerical models, making it ultimately viable for scaled-up, full system-level modeling. Both experimental test results and full wave simulation results are used to validate the foundational model.

Computational electromagnetics↗

Advanced Modular Power System Electronics Enclosure Thermal Testing

An analysis was set up to model the temperature of the advanced modular power system (AMPS) power distribution cards when installed within the electronics enclosure case. The analysis was used to determine the steady-state temperature distribution of the cards within the case. To verify the analysis, an experiment was set up and conducted to simulate the operation of the cards within the enclosure. Four tests were conducted. The tests varied the position of the cold plate and evaluated the use of a thermal compound to reduce the contact resistance between the joints within the thermal path between the cards and the cold plate. Three of the four cases examined showed very good agreement between the analysis and the experiment with a less than 1-percent variation in the predicated temperatures determined through the analysis and the experimentally derived temperatures. In the remaining case, the difference between the analysis and experiment was approximately 12 percent. Both the experiment and analysis showed that the modular power conditioning cards can be maintained within their desired maximum operating temperature range of 40 to 45 °C through thermal conduction to a cold plate when operating with their estimated maximum heat output of 16 W per card.

Colozza, Anthony J.↗