Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Imaging Hydrated Microbial Extracellular Polymers: Comparative Analysis by Electron Microscopy

Microbe-mineral and -metal interactions represent a major intersection between the biosphere and geosphere but require high-resolution imaging and analytical tools for investigating microscale associations. Electron microscopy has been used extensively for geomicrobial investigations and although used bona fide, the traditional methods of sample preparation do not preserve the native morphology of microbiological components, especially extracellular polymers. Herein, we present a direct comparative analysis of microbial interactions using conventional electron microscopy approaches of imaging at room temperature and a suite of cryo-electron microscopy methods providing imaging in the close-to-natural hydrated state. In situ, we observed an irreversible transformation of bacterial extracellular polymers during the traditional dehydration-based sample preparation that resulted in the collapse of hydrated gel-like EPS into filamentous structures. Dehydration-induced polymer collapse can lead to inaccurate spatial relationships and hence could subsequently affect conclusions regarding nature of interactions between microbial extracellular polymers and their environment.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-scale imaging of high-pressure hydrogen induced damage in EPDM rubber using X-ray microcomputed tomography, helium-ion microscopy and transmission electron microscopy

Ethylene propylene diene (EPDM) rubber has gained increasing interest for use in hydrogen infrastructure due to its excellent sealing performance and low temperature properties. However, severe structural damage has been observed in EPDM O-rings after exposure to high-pressure hydrogen. The origination and propagation mechanisms of this damage are poorly understood. Here, to address this knowledge gap, multi-scale imaging leveraging X-ray micro-computed tomography (micro-CT), helium ion microscopy (HeIM), and transmission electron microscopy (TEM) were used in this work to study a series of sulfur-cured ethylene propylene diene (EPDM) rubber materials with varying additives that were exposed to different hydrogen environments. Micro-CT captured the substantial structural damage due to hydrogen exposure; it revealed an association between zinc oxide (ZnO) particles and damage initiation. Further studies by TEM and scanning TEM with energy dispersive X-ray spectroscopy (EDS) were focused on these particles at the micro-to nano-scale range. TEM indicated that hydrogen causes void formation at the interface between ZnO and the rubber matrix. HeIM enabled imaging of surface morphology of the material at high resolution pre- and post-hydrogen exposure while providing information on chemical composition and that cannot be captured by either micro-CT or TEM.

08 HYDROGEN↗

Analysis of compositional uniformity in Al{sub x}Ga{sub 1−x}N thin films using atom probe tomography and electron microscopy

Calculated frequency distributions of atom probe tomography reconstructions (∼80 nm field of view) of very thin Al{sub x}Ga{sub 1−x}N (0.18 ≤ x ≤ 0.51) films grown via metalorganic vapor phase epitaxy on both (0001) GaN/AlN/SiC and (0001) GaN/sapphire heterostructures revealed homogeneous concentrations of Al and chemically abrupt Al{sub x}Ga{sub 1−x}N/GaN interfaces. The results of scanning transmission electron microscopy and selected area diffraction corroborated these results and revealed that neither superlattice ordering nor phase separation was present at nanometer length scales.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A versatile enhanced freeze-substitution protocol for volume electron microscopy

Volume electron microscopy, a powerful approach to generate large three-dimensional cell and tissue volumes at electron microscopy resolutions, is rapidly becoming a routine tool for understanding fundamental and applied biological questions. One of the enabling factors for its adoption has been the development of conventional fixation protocols with improved heavy metal staining. However, freeze-substitution with organic solvent-based fixation and staining has not realized the same level of benefit. Here, we report a straightforward approach including osmium tetroxide, acetone and up to 3% water substitution fluid (compatible with traditional or fast freeze-substitution protocols), warm-up and transition from organic solvent to aqueous 2% osmium tetroxide. Once fully hydrated, samples were processed in aqueous based potassium ferrocyanide, thiocarbohydrazide, osmium tetroxide, uranyl acetate and lead acetate before resin infiltration and polymerization. We observed a consistent and substantial increase in heavy metal staining across diverse and difficult-to-fix test organisms and tissue types, including plant tissues ( Hordeum vulgare ), nematode ( Caenorhabditis elegans ) and yeast ( Saccharomyces cerevisiae ). Our approach opens new possibilities to combine the benefits of cryo-preservation with enhanced contrast for volume electron microscopy in diverse organisms.

59 BASIC BIOLOGICAL SCIENCES↗

In Situ Transmission Electron Microscopy Study of Electrochemical Lithiation and Delithiation Cycling of the Conversion Anode RuO 2

Conversion-type electrodes represent a broad class of materials with a new Li + reactivity concept. Of these materials, RuO 2 can be considered a model material due to its metallic-like conductivity and its high theoretical capacity of 806 mAh/g. In this study, we use in situ transmission electron microscopy to study the reaction between single-crystal RuO 2 nanowires and Li + . We show that a large volume expansion of 95% occurs after lithiation, 26% of which is irreversible after delithiation. Significant surface roughening and lithium embrittlement are also present. Furthermore, we show that the initial reaction from crystalline RuO 2 to the fully lithiated mixed phase of Ru/Li 2 O is not fully reversible, passing through an intermediate phase of Li x RuO 2 . In subsequent cycles, the phase transitions are between amorphous RuO2 in the delithiated state and a nanostructured network of Ru/Li 2 O in the fully lithiated phase.

25 ENERGY STORAGE↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Considerations for imaging thick, low contrast, and beam sensitive samples with liquid cell transmission electron microscopy

Transmission electron microscopy of whole cells is hindered by the inherently large thickness and low atomic contrast intrinsic of cellular material. Liquid cell transmission electron microscopy, allows samples to remain in their native hydrated state and may permit visualizing cellular dynamics in-situ. However, imaging biological cells with this approach remains challenging and identifying an optimal imaging regime using empirical data would help foster new advancements in the field. Recent questions about the role of the electron beam inducing morphological changes or damaging cellular structure and function necessitates further investigation of electron beam-cell interactions, but is complicated by variability in imaging techniques used across various studies currently present in literature. The necessity for using low electron fluxes for imaging biological samples requires finding an imaging strategy which produces the strongest contrast and signal to noise ratio for the electron flux used. Here, we experimentally measure and evaluate signal to noise ratios and damage mechanisms between liquid and cryogenic samples for cells using multiple electron imaging modalities all on the same instrument and with equivalent beam parameters to standardize the comparison. We also discuss considerations for optimal electron microscopy imaging conditions for future studies on whole cells within liquid environments.

Moser, Trevor H. (ORCID:0000000193990514)↗

Direct Visualization of Solid Electrolyte Interphase Formation in Lithium-Ion Batteries with In Situ Electrochemical Transmission Electron Microscopy

Complex, electrochemically driven transport processes form the basis of electrochemical energy storage devices. The direct imaging of electrochemical processes at high spatial resolution and within their native liquid electrolyte would significantly enhance our understanding of device functionality, but has remained elusive. In this work we use a recently developed liquid cell for in situ electrochemical transmission electron microscopy to obtain insight into the electrolyte decomposition mechanisms and kinetics in lithium-ion (Li-ion) batteries by characterizing the dynamics of solid electrolyte interphase (SEI) formation and evolution. Here we are able to visualize the detailed structure of the SEI that forms locally at the electrode/electrolyte interface during lithium intercalation into natural graphite from an organic Li-ion battery electrolyte. We quantify the SEI growth kinetics and observe the dynamic self-healing nature of the SEI with changes in cell potential.

25 ENERGY STORAGE↗

In situ transmission electron microscopy of electron-beam induced damage process in nuclear grade graphite

Atomic level processes involved in the swelling and crack-closing in nuclear grade graphite under electron irradiation have been observed in real-time using transmission electron microscopy. Noise-filtered lattice images show the formation of vacancy loops, interstitial loops and resulting dislocations with unprecedented clarity. The dislocation dipoles formed via vacancy loops were found to undergo climb resulting in extra basal planes. Concurrent EELS studies showed a reduction in the atomic density because of the breakage of hexagonal carbon rings. The formation of new basal planes via dislocation climb in addition to the bending/breaking of basal planes leads to swelling and closing of micro-cracks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of zirconium carbides using electron microscopy, optical anisotropy, Auger depth profiles, X-ray diffraction, and electron density calculated by charge flipping method

Samples with five different zirconium carbide compositions (C/Zr molar ratio=0.84, 0.89, 0.95, 1.05, and 1.17) have been fabricated and studied using a variety of experimental techniques. Each sample was zone refined to ensure that the end product was polycrystalline with a grain size of 10-100 {mu}m. It was found that the lattice parameter was largest for the x=0.89 composition and smallest for the x=1.17 total C/Zr composition, but was not linear; this nonlinearity is possibly explained using electron densities calculated using charge flipping technique. Among the five samples, the unit cell of the ZrC{sub 0.89} sample showed the highest electron density, corresponding to the highest carbon incorporation and the largest lattice parameter. The ZrC{sub 0.84} sample showed the lowest carbon incorporation, resulting in a larger number of carbon vacancies and resultant strain. Samples with larger carbon ratios (x=0.95, 1.05, and 1.17) showed a slight decrease in lattice parameter, due to a decrease in electron density. Optical anisotropy measurements suggest that these three samples contained significant amounts of a graphitic carbon phase, not bonded to the Zr atoms. - Graphical abstract: Characterization of zirconium carbides using electron microscopy, optical anisotropy, Auger depth profiles, X-ray diffraction, and electron density calculated by the charge flipping method. Highlights: Black-Right-Pointing-Pointer The lattice parameter variation: ZrC{sub 0.89}>ZrC{sub 0.84}>ZrC{sub 0.95}>ZrC{sub 1.05}>ZrC{sub 1.17}. Black-Right-Pointing-Pointer Surface oxygen with no correlation to the lattice parameter variation. Black-Right-Pointing-Pointer ZrC{sub 0.89} had highest electron densities correspond to highest carbon incorporation. Black-Right-Pointing-Pointer Second highest lattice parameter in ZrC{sub 0.84} due to strain. Black-Right-Pointing-Pointer Unit cell electron density order: ZrC{sub 0.95}>ZrC{sub 1.05}>ZrC{sub 1.17}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Studies of Amorphous Materials by Fluctuation Electron Microscopy

Fluctuation Electron Microscopy (FEM) is a technique that examines the fluctuations in electron scattering across a uniformly thin amorphous sample. The statistics of the intensity fluctuations, mean and variance, reveal any underlying medium-range order present in the structure. The goals of this project were: (1) To determine the fundamentals of the scattering physics that gives rise to the variance signal in fluctuation electron microscopy (FEM); (2) To use these discoveries to find ways to quantify FEM; (3) To apply the FEM method to interesting and technologically important families of amorphous materials, particularly those with important applications in energy-related processes. Excellent progress was made in items (1) and (2). In stage (3) we did not examine the metamict zircons, as proposed. Instead, we examined films of polycrystalline and amorphous semi-conducting diamond. Significant accomplishments are: (1) A Reverse Monte Carlo procedure was successfully implemented to invert FEM data into a structural model. This is computer-intensive, but it demonstrated that diffraction and FEM data from amorphous silicon are most consistent with a paracrystallite model. This means that there is more diamond-like topology present in amorphous silicon than is predicted by the continuous random network model. (2) There is significant displacement decoherence arising in diffraction from amorphous silicon and carbon. The samples are being bombarded by the electron beam and atoms do not stay still while being irradiated – much more than was formerly understood. The atom motions cause the destructive and constructive interferences in the diffraction pattern to fluctuate with time, and it is the time-averaged speckle that is being measured. The variance is reduced by a factor m, 4 ≤ m ≤ 1000, relative to that predicted by kinematical scattering theory. (3) Speckle intensity obeys a gamma distribution, where the mean intensity $ \overline{I}\ $ and m are the two parameters governing the shape of the gamma distribution profile. m is determined by the illumination spatial coherence, which is normally very high, and mostly by the displacement decoherence within the sample. (4) Amorphous materials are more affected by the electron beam than are crystalline materials. Different samples exhibit different disruptibility, as measured by the effective values of m that fit the data. (5) Understanding the origin of the displacement decoherence better should lead to efficient methods for computing the observed variance from amorphous materials.

36 MATERIALS SCIENCE↗

Freeze It or Leave It? Evaluating the Role of Cryo-Electron Microscopy in Battery Research

Cryogenic electron microscopy (cryo-EM) continues to gain prominence in materials science, particularly in battery research where it has enabled high-resolution, multimodal characterization of electrode materials and interfaces that otherwise degrade quickly under electron beam irradiation. But as anyone who has attempted cryo-EM techniques knows, freezing comes at a cost; cryo-EM experiments are time-consuming, highly sensitive, and carry an increased risk of artifacts due to issues such as frost contamination. Thus, when planning new characterization of battery materials or other beam-sensitive samples, it is critical to consider whether (and which) cryo-EM techniques are appropriate, based on study goals and an understanding of electron beam-sample interactions. Here we review such considerations for battery materials to elucidate the questions of when, why, and how to freeze to achieve high-quality characterization.

25 ENERGY STORAGE↗

Big Data Analytics for Scanning Transmission Electron Microscopy Ptychography

Electron microscopy is undergoing a transition; from the model of producing only a few micrographs, through the current state where many images and spectra can be digitally recorded, to a new mode where very large volumes of data (movies, ptychographic and multi-dimensional series) can be rapidly obtained. In this paper, we discuss the application of so-called “big-data” methods to high dimensional microscopy data, using unsupervised multivariate statistical techniques, in order to explore salient image features in a specific example of BiFeO 3 domains. Remarkably, k-means clustering reveals domain differentiation despite the fact that the algorithm is purely statistical in nature and does not require any prior information regarding the material, any coexisting phases, or any differentiating structures. While this is a somewhat trivial case, this example signifies the extraction of useful physical and structural information without any prior bias regarding the sample or the instrumental modality. Further interpretation of these types of results may still require human intervention. Finally, however, the open nature of this algorithm and its wide availability, enable broad collaborations and exploratory work necessary to enable efficient data analysis in electron microscopy.

36 MATERIALS SCIENCE↗