Ultrafast electron diffraction with radio-frequency compressed electron pulses
We report on the complete characterization of time resolution in an ultrafast electron diffraction (UED) instrument based on radio-frequency electron pulse compression. The temporal impulse response function of the instrument was determined directly in pump-probe geometry by performing electron-laser pulse cross-correlation measurements using the ponderomotive interaction. With optimal settings, a stable impulse response of 334{+-}10 fs was measured at a bunch charge of 0.1 pC (6.24 Multiplication-Sign 10{sup 5} electrons/pulse); a dramatic improvement compared to performance without pulse compression. Phase stability currently limits the impulse response of the UED diffractometer to the range of 334-500 fs, for bunch charges ranging between 0.1 and 0.6 pC.