Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical components”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Precitech N200 Lathe Refurbish/Upgrade Project [Slides]

Background: LANL purchased two Precitech N200 Lathes in 2002; Machines were modified for glovebox operations; First lathe became operational in 2009; After nearly 15 years of continuous operation, electric components have started to fail; Precitech has been refurbishing N200 lathes for other 20 years; Existing lathes in PF-4 needed for surveillances/certification missions; after training at Precitech, LANL workers will perform refurbishment/upgrade tasks in PF-4.

42 ENGINEERING↗

Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems

Life Cycle Assessment (LCA) is a structured, comprehensive method of quantifying material- and energy-flows and their associated impacts in the life cycles of products (i.e., goods and services). One of the major goals of IEA PVPS Task 12 is to provide guidance on assuring consistency, balance, transparency and quality of LCA to enhance the credibility and reliability of the results. The current report presents the latest consensus life cycle inventories among the authors, PV LCA experts in North America, Europe, Asia and Australia. At this time consensus is limited to four technologies for which there are well-established and up-to-date life cycle inventory (LCI) data (mono- and multi-crystalline Si, CdTe, CIGS, as well as one emerging technology (perovskite silicon tandem). LCIs are necessary for LCA and the availability of such data is often the greatest barrier for conducting LCA. The Task 12 LCA experts have put great efforts in gathering and compiling the LCI data presented in this report. These include detailed inputs and outputs during manufacturing of cell, wafer, module, and balance-of-system (i.e., structural and electrical components) that were estimated from actual production and operation facilities. In addition, data are presented to enable analyses of various types of PV installations; these include operational data of rooftop and ground-mount PV systems and country-specific PV-mixes. The LCI datasets presented in this report are the latest that are available to the public describing the status in 2018 for crystalline Si (some manufacturing data from 2011 were not updated), 2015 and 2017-2018 for CdTe, 2010 for CIGS, 2010 for HCPV, and 2017 for perovskite silicon tandem technology.

14 SOLAR ENERGY↗

RECON Label Quality Report

The final quality of any AI/ML system is directly related to the quality of the input data used to train the system. In this case, we are trying to build a reliable image classifier that can correctly identify electrical components in x-ray images. The classification confidence is directly related to the quality of the labels in the training data, which are used in developing the AI/ML classifier. Incorrect or incomplete labels can substantially hinder the performance of the system during the training process, as it tries to compensate for variations that should not exist. Image labels are entered by subject matter experts, and in general can be assumed to be correct. However, this is not a guarantee, so developing ways to measure label quality and help identify or reject bad labels is important, especially as the database continues to grow. Given the current size of the database, a full manual review of each component is not feasible. This report will highlight the current state of the “RECON” x-ray image database and summarize several recent developments to try to help ensure high quality labeling both now and in the future. Questions that we hope to answer with this development include: 1) Are there any components with incorrect labels? 2) Can we suggest labels for components that are marked “Unknown”? 3) What kind of overall confidence do we have in the quality of the existing labels? 4) What systems or procedures can we put in place to maximize label quality?

42 ENGINEERING↗

FY25 Mid-Year Report: FABIA In-Field Laser Absorption Spectroscopy for UF6 Enrichment

From September 2024 through April 2025, the FABIA team has been working towards completing the IAEA requirements for technology transfer of the instrument. The primary tasks in place for this transfer are to complete a validation study using various enrichments of UF6, to finalize the data analysis routines in the FABIA software, and to complete FABIA electrical component compatibility. These topics are expanded in greater detail below. In addition to the tasks, the FABIA team hosted IAEA representatives to observe a live analysis demonstration of the FABIA instrument on February 3, 2025. As a result of this visit, some updates to the tasks were communicated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Authenticating a printed circuit board

A computing module is described herein, wherein the computing module is configured to perform acts including generating a digital signature for a printed circuit board (PCB), wherein the digital signature is based upon a sensor signal generated by a sensor that is electrically coupled to at least one of a trace of the PCB or an electrical component of the PCB. The acts further include determining that the PCB is authentic and is free of tampering based upon the digital signature. The acts additionally include outputting an indication that the PCB is authentic and is free of tampering responsive to determining that the PCB is authentic and is free of tampering.

97 MATHEMATICS AND COMPUTING↗

CITRC Cable Info

Working on a DOE project with university sub-contractors to build power grid simulations. We need the cable size and spacing to build accurate models. Other related documents on the physical set up and electrical components have been released, INL/MIS-20-59900 and INL/MIS-20-60003.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Carbon material supported hollow metal oxide nanoparticles, methods and applications

A method for preparing a material composition comprising a hollow transition metal oxide nanoparticle supported upon a carbon material support includes a solution impregnation process step, followed by a thermal reduction process step and finally a thermal oxidation process step. The material composition, an electrode and an electrical component such as but not limited to a battery are all predicated at least in-part upon the material composition prepared in accord with the foregoing method. The foregoing material composition, electrode, battery and method may ultimately provide a LIB with enhanced performance.

Yu, Yingchao↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems: Preprint

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. In this paper, a holistic impulse-based MOV lifetime estimation framework is proposed. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs: Preprint

The growing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electrical grids. Oftentimes, this pressure leads to electrical components failures which might ignite wildfires. This work develops a novel model to balance the reliability of power networks operations and risks of wildfires ignition by optimizing the operational schedule of power transmission networks considering time-varying risk measures that consider exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfires risk. The results demonstrate the ability of the model to reduce wildfires risks significantly without considerable load shedding.

energy scheduling↗

Double-sided cooling cold plates with overhanging heat sinks and through body busbar for high-power density power electronics

A double-sided cold plate includes a manifold comprising openings extending from a first surface of the manifold through the manifold to a second surface of the manifold forming recesses within the manifold and an inlet channel and an outlet channel fluidly coupled to the recesses within the manifold, a plurality of first heat sinks coupled to the first surface of the manifold enclosing the openings on the first surface, and a plurality of second heat sinks positioned adjacent each other along a length of the manifold and coupled to the second surface of the manifold, enclosing the openings on the second surface, a width of the plurality of second heat sinks is greater than a width of the manifold thereby forming an overhanging portion on each lengthwise side of the manifold, the overhanging portion configured to mechanically support a plurality of electrical components positioned around a perimeter of the manifold.

Zhou, Feng↗

ECAR-6573 Rev 0 PGS Stirling Engine Radiation Lifetime Estimate

This evaluation determines the expected service lifetime for the Stirling Engines in the Power Generation Subsystem (PGS) based on the radiation resistance of the organic materials, electrical components, and magnets, along with the projected radiation dose rate. Components that are not projected to last for a six-month operational period are discussed in more detail, including their associated risk due to failure and possible remedial actions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Electrostatic energy harvester

An electrostatic energy harvester broadly comprises an electrical energy storage component, an electrical energy transfer stage, first and second variable capacitors, and a switching control module. The electrical energy transfer stage includes diode-connected transistors and dictates electrical energy transfer between the electrical energy storage component and the variable capacitors. The switching control module timely switches between the first and second variable capacitors according to a state machine. Subsequent electrical energy investments from the electrical energy storage component are less than an initial electrical energy investment due to remnant electrical energy remaining at the previously active one of the first and second variable capacitors from previous electrical energy harvesting.

Wilson, Amy Charlene↗

Electrostatic energy harvester

An electrostatic energy harvester broadly comprises an electrical energy storage component, an electrical energy transfer stage, first and second variable capacitors, and a switching control module. The electrical energy transfer stage includes diode-connected transistors and dictates electrical energy transfer between the electrical energy storage component and the variable capacitors. The switching control module timely switches between the first and second variable capacitors according to a state machine. Subsequent electrical energy investments from the electrical energy storage component are less than an initial electrical energy investment due to remnant electrical energy remaining at the previously active one of the first and second variable capacitors from previous electrical energy harvesting.

Wilson, Amy Charlene↗

Electrostatic energy harvester

An electrostatic energy harvester broadly comprises an electrical energy storage component, an electrical energy transfer stage, first and second variable capacitors, and a switching control module. The electrical energy transfer stage includes diode-connected transistors and dictates electrical energy transfer between the electrical energy storage component and the variable capacitors. The switching control module timely switches between the first and second variable capacitors according to a state machine. Subsequent electrical energy investments from the electrical energy storage component are less than an initial electrical energy investment due to remnant electrical energy remaining at the previously active one of the first and second variable capacitors from previous electrical energy harvesting.

Wilson, Amy Charlene↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

Hydrogen Energy Storage Integrated with a Combined Cycle Plant

A project is being developed that will build upon the existing infrastructure and resources at the Intermountain Power Project (IPP) site to provide reliable, dispatchable energy and to support the transmission of renewable energy resources while transitioning to an economical green energy future. The concept study depicted in this report outlines a techno-economic optimization to fulfill the demand for 30% vol hydrogen co-firing in the IPP 840 MW advanced class combined cycle power plant. In an initial step, a site assessment concluded the site has sufficient land available to co-locate a hydrogen production and storage facility. The team evaluated and defined a scalable concept that considered technology characteristics, including input and output models to be used for optimization purposes. The concept for the hydrogen production and storage system integrates multiple technologies, to determine system size and scalable approach, for each of the technologies evaluated, the team defined component and subcomponent sizes, minimum and maximum capacity, modularity, component utility consumption (electric, water), component flexibility and servicing, layout, and technology status, as well as technology alternatives. For hydrogen generation, the project considers Siemens Energy’s Silyzer-300 (S300) technology, a 17.5 MW modular Proton Exchange Membrane (PEM) electrolyzer. For the S300 configuration, the team determined that three S300 arrays, or approximately 1,000 kg/hr, per block would yield a compact block design. This configuration results in a fairly wide and flexible arrangement that fits well into the spaces available at the site. Therefore, the overall design approach is based on multiple identical blocks of 3 arrays to minimize engineering cost and optimize constructability. In parallel, a transmission screening study was conducted to determine any potential transmission constraints from the energy sources that could feed the hydrogen production equipment. The study results show that minimum transmission constraints would be encountered to deliver 400 MW renewable generation from southern California, or south-central Wyoming. At last, the techno-economic analysis concluded that a scenario that uses solar and wind power yields the lowest levelized cost of hydrogen (LCOH 2 ) production and the lowest cost per tonne of CO 2 reduced. In this optimized scenario, the hydrogen production plant was determined as 6,201 kg/hr and the hydrogen storage (underground cavern) was determined as 4,600 tonnes. The resulting capacity factor for the hydrogen production plant was 66.33% with 8,745 operating hours in one year. This techno-economic analysis provided various options for integrating hydrogen storage at the Intermountain Power Plant site to co-fire the CCPP units. The results provide insightful data about the magnitude of capacity needed and the economics of producing hydrogen and reducing CO 2 emissions.

08 HYDROGEN↗

Component Assessment of the Electric Transmission Grid to Hurricanes

The increased frequency and intensity of extreme weather events from climate change necessitates understanding impacts on critical infrastructure, particularly electrical transmission grids. One of the foundational concepts of a grid's resilience is its robustness to extreme weather events, such as hurricanes. Resilience of the electric grid to high wind speeds is predicated upon the location and physical characteristics of the system components. Previous modeling assessments of electric grid failure were done at the systems level with assumptions on location and type of specific components. To facilitate more explicit adaptation metrics, accurate component-level information is needed. In this study, we build and utilize a data set of location, physical characteristics, and age of transmission structures for nine counties in the Florida Panhandle. These component characteristics were then simulated for failure under a variety of scenarios using fragility curves. Eight hurricanes were modeled using Hazus from the Federal Emergency Management Administration and the resulting impact to the network was assessed. The network was generated using the transmission lines and towers, showing increasing impacts to network efficiency with larger storms. Although modern transmission structures are built under the more stringent extreme wind loading construction standards, the prevalence of older, wooden transmission structures throughout the region poses a substantial risk to reliable electricity transmission during tropical cyclone events from the Gulf of Mexico.

24 POWER TRANSMISSION AND DISTRIBUTION↗