Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Portable nanosecond pulsed air plasma jet

Low-temperature atmospheric pressure plasmas are of great importance in many emerging biomedical and materials processing applications. The redundancy of a vacuum system opens the gateway for highly portable plasma systems, for which air ideally becomes the plasma-forming gas and remote plasma processing is preferred to ensure electrical safety. Typically, the gas temperature observed in air plasma greatly exceeds that suitable for the processing of thermally liable materials; a large plasma-sample distance offers a potential solution but suffers from a diluted downstream plasma chemistry. This Letter reports a highly portable air plasma jet system which delivers enhanced downstream chemistry without compromising the low temperature nature of the discharge, thus forming the basis of a powerful tool for emerging mobile plasma applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ecological benefits of dc power transmission

The environmental effects of dc overhead transmission lines are examined. The major effects of ac and dc transmission lines are compared. Dc lines have advantages compared to ac lines in terms of electrical safety for people under the lines, biological effects, corona losses, and clearance width.

54 ENVIRONMENTAL SCIENCES↗

A non-destructive method for crack quantification in photovoltaic backsheets under accelerated and real-world exposures

The long-term durability of photovoltaic modules is paramount for the continued growth of the industry. Polymer backsheets are of particular concern since they provide electrical insulation and an environmental barrier. In this paper, 23 freestanding, multilayer backsheets with nine unique material combinations underwent four different weathering exposures under accelerated and real-world conditions. Besides changes in color and gloss, the induced degradation included parallel or mudflat cracks on 11 backsheets, sometimes in combination with delamination or blistering. Similar degradation has been observed in previous studies and is concerning since cracks compromise the mechanical integrity and electrical safety of backsheets. Quantitative parameters are desirable to reliably classify categories of cracks and supply unbiased features for statistical analysis in predictive lifetime models. We developed an analysis technique that utilizes surface profilometry data to quantify the depth, width, area, spacing, and number of cracks. Parameters are automatically extracted from the raw data by an algorithm running on a high performance distributed computing cluster. Our algorithm excelled at characterizing parallel cracks with minimal de-adhesion, and only an estimated 4% of crack detections were false positives. The addition of humidity and temperature variation formed up to three times as many cracks on a photodose basis compared to dry, constant temperature exposures. Cracks in real-world and accelerated exposures propagated to similar depths with equivalent photodoses; however, the number of cracks formed in accelerated exposures was far greater on a photodose basis. Of samples that cracked, the best performing backsheet configuration was polyvinyl fluoride/poly (ethylene-terephthalate)/polyethylene (PVF/PET/PE) while the least durable was PET/PET/ethylene-vinyl acetate. Finally, none of the six PVF/PET/PVF backsheets cracked in any of the exposures.

14 SOLAR ENERGY↗

An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

On the Investigation of Phase Fault Classification in Power Grid Signals: A Case Study for Support Vector Machines, Decision Tree and Random Forest

In monitoring the power grid, an ability to differentiate between fault types is essential to ensuring electrical safety. Accordingly, this study introduces a fault detection and classification method by considering different machine learning (ML) and feature extraction (FE) methods combinations. Specifically, the proposed method is established in two classification layers; the first layer determines the fault, and the second layer distinguishes the type of fault. Based on the proposed system model, this study seeks to determine the influential data attributes in a power grid signal using FE methods, including fast Fourier transform, power spectral density (PSD), auto-correlation, and wavelet transform (WT). A cross-comparison of the effectiveness of the Support Vector Machine (SVM), Decision Tree (DT), and Random Forest (RF) is also performed to accomplish the classification layers of the proposed method. The designed algorithm is analyzed under the various combinations of FE and ML methods, and outcomes are presented by considering the trade-off between computational complexity and prediction accuracy. The results reveal that the RF-based ML algorithm shows the most accurate classification performance with PSD, and the most time-saving of the models is the DT WT. Also, SVM emerges superior on a subsequent test of the simulated models on real-world signals.

Galbraith, Kelli↗

NA--SS-SNL-2000-2016-0005 Electrical Shock of Worker Performing R&D Work

At approximately 10am on 6/29/16 during testing of the DVFS2.0 fireset, an employee was shocked by a capacitor as he was removing it from the fireset following a test. The test, which was documented in a Technical Work Document (TWD) was to charge the fireset and discharge it into a fixed resistive load. The fireset was used within a Center 2600 Electrical Safety Box (ESB). Another employee acted as the required Second Person. Following the final test during which the 0.5uF capacitor was charged to 2500V (according to the voltage divider built into the fireset), the capacitor was allowed to discharge.

42 ENGINEERING↗

Working Safely at KEK

This booklet has been prepared for KEK users, primarily working on the Belle II experiment, with useful information for maintaining a safe working environment. In it, topics from initiating and fulfilling a work plan to radiological and electrical safety to fall prevention are introduced with instructions and hints for keeping your workplace safe.

43 PARTICLE ACCELERATORS↗

The NREL Sensor Laboratory Detection of Hydrogen Emissions

The development of a functional hydrogen detection system is a multifaceted process that integrates hardware, deployments strategies, and analytics which can be supported by the NREL Sensor Laboratory: 1. Support of the design, validation and optimization of sensing prototypes; 2. Guide optimized sensing element development, including control electronics; 3. Laboratory testing to validate/optimize metrological performance (measurement range, detection limit, etc.); 4. Provide test sites for field deployments representative of real-world scenarios with controlled hydrogen releases; 5. Develop sensor placement and operation guidance; 6. Provide guidance on electronics to accommodate facility integration; 7. Electrical safety designs to allow for operation within restricted zones; 8. Integration into facility monitoring and control systems; 9. Guide incorporation of cyber security elements to protect facilities from malicious attacks; 10. Modeling and application of advanced analytics to detect and quantify emissions; 11. Higher Order dispersion models to guide sensor placement for reliable detection; 12. Advanced analytics for improved metrological performances, and to inform inverse modeling; 13. Market support and commercialization (national and international markets); 14. Commercial deployments in H2@SCALE markets (e.g., HUBs and other large-scale hydrogen markets); and 15. Leverage off international collaborations/partnerships (e.g., NREL is on the advisory board for the European initiative "pre-Normative Research on Hydrogen Releases Assessment"-NHyRA).

08 HYDROGEN↗

Distributed Wind Certification Best Practices Guideline: January 16, 2023-January 15, 2026

This Distributed Wind (DW) Certification Best Practices Guideline describes the typical approach for certification of distributed wind turbines above and below 150 kilowatts (kW) in size based on the conformity assessment requirements in the United States. The purpose of the guideline is to clarify and consistently describe the complex path to certification for various systems and components. This is done via clarification of both the required turbine type certification elements, as well as third-party electrical safety listing of turbine system components and subassemblies.

17 WIND ENERGY↗

Best Practice -- Subsurface Investigations

These best practices for Subsurface Survey processes were developed at the Idaho National Laboratory (INL) and later shared and formalized by a sub-committee, under the Electrical Safety Committee of EFCOG. The developed best practice is best characterized as a Tier II (enhanced) survey process for subsurface investigations. A result of this process has been an increase in the safety and lowering of overall cost, when utility hits and their related costs are factored in. The process involves improving the methodology and thoroughness of the survey and reporting processes; or improvement in tool use rather than in the tools themselves. It is hoped that the process described here can be implemented at other sites seeking to improve their Subsurface Investigation results with little upheaval to their existing system.

58 GEOSCIENCES↗

20V, 40 Ah Lithium Ion Polymer Battery for the Spacesuit

Objective: Consider a new battery design for EMU. Results: a) Electrovaya s aerospace cell production line is improving, but must further improve to achieve acceptable reliability; b) Completed functional, vibration, and thermal cycling of LIB; c) So far, electrical safety tests have produced good results; d) Completed functional, vibration, thermal cycling, power quality and EMI of LIB Charger; e) Completed CDR on 9/23/04; and f) Manufacturing Readiness Review for flight cell/battery production scheduled for Dec 04.

Darcy, Eric↗

Propulsion Test Handbook: MSFC and SSC

This Handbook was prepared to provide Propulsion Test Personnel a central source of fundamental reference material. The Testing Process, which is a three-part process of pre-test activities, testing, and post-test activities, involves a collaborative effort from the mechanical, electrical, safety, and environmental disciplines in the test environment. Pre-test activities, testing, and post-test activities processes will vary, per test requirements; however, the content of this Handbook should cover basic procedures and standards that are shared across Centers.

Hammond, John M.↗

Efficient Simulation and Abuse Modeling of Mechanical-Electrochemical-Thermal Phenomena in Lithium-Ion Batteries

NREL's Energy Storage team is exploring the effect of mechanical crush of lithium ion cells on their thermal and electrical safety. PHEV cells, fresh as well as ones aged over 8 months under different temperatures, voltage windows, and charging rates, were subjected to destructive physical analysis. Constitutive relationship and failure criteria were developed for the electrodes, separator as well as packaging material. The mechanical models capture well, the various modes of failure across different cell components. Cell level validation is being conducted by Sandia National Laboratories.

25 ENERGY STORAGE↗

Methods for Evaluating DC Arc Incident Energy in PV Systems: Preprint

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This paper focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of DC arc flash incident energy evaluation. Because of the fast proliferation of PV systems and the lack of formal equivalent calculation guidelines such as IEEE 1584 for AC systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This paper discusses the behavior of PV systems under arc conditions and presents the results of available methods to estimate the dc arc flash incident energy. This paper provides a comparative analysis of a proposed arc-flash incident energy calculation method against different laboratory tests including those performed by NREL. Detailed explanations are provided regarding the effect of PV module I-V and P-V curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2022 Small Turbine Certification Awardee: Eocycle America Corporation

Eocycle's Competitiveness Improvement Project (CIP) award will fund certification testing of the company's EOX S-16 25-kW turbine to make sure it meets UL electrical safety standards. In addition to validating the turbine's reliability and anticipated reduced maintenance requirements, UL certification will also boost consumer confidence in the technology, with the potential to increase the market for the entire small-wind industry.

Competitiveness Improvement Project↗

Use of Automated External Defibrillators

In an effort to improve survival from cardiac arrest, the American Heart Association (AHA) has promoted the Chain of Survival concept, describing a sequence of prehospital steps that result in improved survival after sudden cardiac arrest. These interventions include immediate deployment of emergency medical services, prompt cardiopulmonary resuscitation, early defibrillation when indicated, and early initiation of advanced medical care. Early defibrillation has emerged as the most important intervention with survival decreasing by 10% with each minute of delay in defibrillation. Ventricular Fibrillation (VF) is a condition in which there is uncoordinated contraction of the heart cardiac muscle of the ventricles in the heart, making them tremble rather than contract properly. VF is a medical emergency and if the arrhythmia continues for more than a few seconds, blood circulation will cease, and death can occur in a matter of minutes. During VF, contractions of the heart are not synchronized, blood flow ceases, organs begin to fail from oxygen deprivation and within 10 minutes, death will occur. When VF occurs, the victim must be defibrillated in order to establish the heart’s normal rhythm. On average, the wait for an ambulance in populated areas of the United States is about 11 minutes. In view of these facts, the EFCOG Electrical Safety Task Group initiated this review to evaluate the potential value of deployment and use of automated external defibrillators (AEDs) for treatment of SCA victims. This evaluation indicates the long term survival benefit to victims of SCA is high if treated with CPR plus defibrillation within the first 3-5 minutes after collapse. According to the American Heart Association (AHA), survival rates as high as 74% are possible if treatment and defibrillation is performed in the first 3 minutes. In contrast survival rates are only 5% where no AED programs have been established to provide prompt CPR and defibrillation. ["CPR statistics" American Heart Association] Early intervention with both CPR and defibrillation can result in high long-term survival rates for SCA, as demonstrated by a study investigating the beneficial effects of AED devices at Chicago’s O’Hare and Midway airports. The American Medical Association (AMA) advocates the widespread placement of AEDs [AMA Res. 413, A-02; Res. 424, A-04]; supports increasing government and industry funding for the purchase of AED devices; and encourages the American public to become trained in CPR and the use of AEDs. Some states, including Maryland, have enacted legislation requiring AED devices and a certified responder be available at high school and school-sponsored athletic events due the risk of SCA to athletes (the most common cause of death in young athletes). Ensuring AED availability at Department of Energy (DOE) sites would serve as a means of preventative intervention for over 14,000 DOE employees and 193,000 contract workers. It is estimated 1 per 1,000 adults 35 years of age and older will experience SCA in a given year.

99 GENERAL AND MISCELLANEOUS↗