Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical Port”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Test chamber for low-background IR focal plane testing

A unique and versatile vacuum chamber has been designed for JPL's IR Focal Plane Technology Group. This chamber is equipped with multiple ports for cryogen and electrical vacuum feedthroughs, pumping units, vacuum gages, sources, and detector camera heads. The design incorporates a liquid-nitrogen-cooled optical table and radiation shield for low-background IR detector testing. Focal planes can be tested at temperatures ranging from 300 K to that of liquid helium. This paper describes the design and construction of this low-background IR focal plane test chamber and discusses some of its distinctive features. An analysis of the test chamber's performance is also presented.

Staller, Craig↗

MULTIPACTORING OBSERVATION, SIMULATION AND SUPPRESSION ON A SUPERCONDUCTING TE011 CAVITY

A superconducting cavity of the same shape as used for the development of superconducting photo injectors has been built for the studies of high magnetic field induced Q slope due to the local heating. The multipactoring (MP) problem has been observed on the TE011 mode, 3.29GHz with magnetic field barriers. To understand and overcome this problem, 3D multipactoring simulations by Omega3P and Track3P have been done and found these to be one-point multipactors pulled out from the flat bottom surface by finite normal component of electric field. Asymmetric coupling ports on the side of the beam tube could have caused the distortion of the TE011 mode. The thermometry measurement later confirmed the predicted impact locations. A structure modification has been adopted based on the simulation prediction. Later experimental results with the new geometry indicated softer MP barriers and further simulations indicated that the field perturbation created by the input antenna has also contributed this problem.

43 PARTICLE ACCELERATORS↗

Waste Encapsulation and Storage Facility Stabilization and Ventilation Project-18121

Department of Energy contractor CH2M HILL Plateau Remediation Company (CH2M) is responsible for the safe and compliant operation of the Waste Encapsulation and Storage Facility (WESF), a nuclear materials storage facility at Hanford containing 1,936 highly radioactive capsules containing cesium and strontium. The capsules are currently stored under approximately 4 m (13 ft) of water. The water shields workers from radiation and helps cool the capsules. WESF is a large, concrete structure nominally 48 m (160 ft) long, 30 m (98 ft) wide and 12 m (40 ft) high with the pool cells being approximately 4 m (13 ft) below grade level. It is a robust facility with walls ranging from 0.3 m to 1 m (1 ft to 3 ft) thick. While the capsules are currently in a safe configuration, WESF is an aging facility, and DOE and CH2M are modifying the facility to ensure continued safe and compliant operations and to support the eventual transfer of capsules to dry storage. Dry storage would eliminate the possibility of a release of radioactive material in the unlikely event of a major earthquake that might result in loss of pool storage water and overheating and breach of one or more capsules. The project was divided into two major deliverables: 1) Ventilation: replacement of the existing ventilation system which included a below-grade high efficiency particulate air (HEPA) filter pit with an above grade HEPA filter skid and new fans and ducting. 2) Stabilization: grouting deactivated facility hot cells and other void spaces to the maximum extent practical to reduce material at risk from legacy contamination. The aging ventilation system relied on HEPA filters that exceeded their operational life. Due to the high levels of radionuclide contamination, replacing the filters was impractical and highly hazardous. CH2M installed a new ventilation system to provide safe and compliant ventilation for future operations. The project used an existing, unused ventilation skid that was designed for another project. Repurposing the unused skid presented additional technical challenges to modify the system for the project specific requirements. The new system is above ground, easier to maintain and is built to current standards. New connections inside the facility were installed to allow the new ventilation to operate effectively. The stabilization project is unique in that core drilling and grouting was performed in an operating Hazard Category 2 nuclear facility, which brought forth safety basis and environmental regulatory challenges. The hot cells were isolated from all existing support utilities including electrical, process chemicals, manipulator ports, instrument air, etc. to seal the hot cells and prevent highly contaminated supernate or grout from leaking into adjacent galleries. A high flow grout was used to maximize the distance between injection ports. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assembly and method for interchangeably holding an electrochemical substrate

An electrochemical substrate holder assembly, including: a first housing and a second housing; wherein the first housing and the second housing collectively define an interior space; a first gasket coupled to the first housing and adapted to contact a first side of a substrate; and a second gasket coupled to the second housing and adapted to contact a second side of the substrate; wherein the first gasket and the second gasket are collectively adapted to hold the substrate within the interior space. The first housing defines a first port adapted to receive a first electrical lead to electrically contact the first side of the substrate. The second housing defines a second port adapted to allow a fluid to pass there through to fluidly contact at least the second side of the substrate. The second housing is adapted to receive one or more of a second and third electrical lead.

Freiderich, John W.↗

Electrification Analysis: Container Ports' Cargo Handling Equipment

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline, the Electrification Analysis of Container Ports' Cargo Handling Equipment project. This project created a scalable solution to model energy demand per shipping container moved (kWh/TEU) for an all-electric cargo handling equipment fleet located at a maritime port. The model allows stakeholders to understand energy demand at each electric vehicle (EV) equipment level and is easily scalable to container demand and EV adoption rate projections.

ADVANCED PROPULSION SYSTEMS↗

Capacitive Trans-Impedance Amplifier Circuit with Charge Injection Compensation

A capacitive trans-impedance amplifier circuit with charge injection compensation is provided. A feedback capacitor is connected between an inverting input port and an output port of an amplifier. A MOS reset switch has source and drain terminals connected between the inverting input and output ports of the amplifier, and a gate terminal controlled by a reset signal. The reset switch is open or inactive during an integration phase, and closed or active to electrically connect the inverting input port and output port of the amplifier during a reset phase. One or more compensation capacitors are provided that are not implemented as gate oxide or MOS capacitors. Each compensation capacitor has a first port connected to a compensation signal that is a static signal or a toggling compensation signal that toggles between two compensation voltage values, and a second port connected to the inverting input port of the amplifier.

Milkov, Mihail M.↗

Analytic Framework for Optimal Sizing of Hydrogen Fueling Stations for Heavy Duty Vehicles at Ports (CRADA 512)

This CRADA presents the strategy that PNNL and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL) in properly sizing a hydrogen station for class 8 drayage trucks at the Port of Seattle (Port), as part of a coordinated plan of mixed uses for hydrogen. The proper sizing for the fueling station is unique from past experiences because it will be part of a coordinated plan for a multi-use scheme for the hydrogen, and not a stand-alone fueling station. The multiple use-streams, and their relative values, will impact all facets of station sizing and design, including fueling rates, storage technology and size, equipment selection, and safety considerations. The future deployment of this fueling station, and its proper sizing, is seen as a critical first step in the larger vision of utilizing hydrogen to address a range of issues for SCL and the Port. These include, but are not limited to, large scale fueling of medium duty (MD) and heavy duty (HD) vehicles to reduce emissions, support of adjacent light duty (LD) vehicles, support of critical port operation during extreme events (e.g. resiliency), mitigation of capital intensive electrical distribution system upgrades to support evolving port operations, a market resource that can be used by SCL to generate revenue, and support of planned future maritime operations that currently require heavy use of shipboard hydrogen. While the broader use of hydrogen by SCL and the Port is not the focus of this CRADA, how its use impacts the design of the initial vehicle fueling station, and the modular approach, are the central work. As such, this project will develop the framework and process for developing a modular station design that considers the broader range of coordinate uses of hydrogen as an energy resource.

08 HYDROGEN↗

Data Files for “The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure"

This data set includes modeling results from “The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure” including region-specific [i.e., national, state, and core-based statistical area (CBSA)—cities/towns] electric vehicle supply equipment (EVSE) port count requirements in 2025 and 2030 for multiple scenarios described in the study. Please cite as: Wood, E., B. Borlaug, M. Moniot, D.-Y. Lee, Y. Ge, F. Yang, and Z. Liu. 2023. The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-85654.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Nuclear Reactors for Maritime Ports

Maritime ports are entering a period of sharply rising electricity demand as operations are electrified, shore power adoption grows, and energy-intensive industries expand near ports. This report evaluates the feasibility of small nuclear reactors at U.S. ports, which could offer stable baseload power and reduced dependence on regional grids. The report describes the current state of advanced reactor technologies and other factors important for future deployment such as safety and operations, siting requirements, regulatory environments and policy, and other co-benefit considerations. A structured evaluation across a diverse group of U.S. ports highlights the wide variation in feasibility. Fifteen ports were analyzed through port interviews and data collection to assess the port-specific conditions that most impact advanced reactor deployment. The analysis found that the most feasible ports for deployment have favorable geotechnical stability, supportive regulatory environments, and substantial energy loads in a grid-constrained environment. Additionally, an initial reactor size matching was done for the ports based on their reported energy consumption across different modes of operation. However, further analysis and detailed data will be required in the future to determine the optimal reactor-port matching. The economic viability to adopt this technology will be dictated by competitive cost of nuclear-generated electricity compared to other alternatives. Overall, small nuclear reactors present a promising but highly site-dependent pathway for ports seeking resilient, high-capacity energy solutions that support future energy demands. This report identifies key areas for future research and highlights ports that warrant further evaluation to assess the viability of small nuclear reactor implementation. By establishing these priorities, the analysis provides support for the development of informed strategies for potential advanced nuclear technology deployment. The inclusion of ports in this report does not imply their endorsement of nuclear energy generation, and the authors are grateful for the information, expertise, and perspectives they contributed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Connector system for photovoltaic array

A photovoltaic assembly comprising; (a) at least two photovoltaic components that are adjacent to each other in a first direction, each photovoltaic component comprising (i) a partial recess in communication with the partial recess in an adjacent photovoltaic component and (ii) one or more connector receptors aligned in a second direction which is non-parallel to the first direction; (b) a connector located at feast partially in the partial recess of the photovoltaic component and at least partially in the partial recess of the adjacent photovoltaic component so that the connector connects the photovoltaic component to the adjacent photovoltaic component, the connector comprising: (i) a flexible housing having a first end and a second end; (ii) one or more connection ports at the first end; (iii) one or more connection ports at the second end; and (iv) one more flexible electrical conductors that extend from the one or more connection ports at the first end to the one or more connection ports at the second end; wherein the connector is flexible so that the first end and the second end are movable relative to each other in a plane, out of the plane, or both; wherein the one or more connection ports at the first end and the one or more connection ports at the second end form a connection with the one or more connector receptors of the photovoltaic component and the adjacent photovoltaic component so that the connector electrically connects the photovoltaic component to the adjacent photovoltaic component.

14 SOLAR ENERGY↗

Upgrades to the in-vessel calibration light source on JET

Since 2010, an in-vessel calibration light source (ICLS) has been used periodically on JET to calibrate a range of diagnostics at UV, visible, and IR wavelengths. During shutdowns, the ICLS (which is essentially an integrating sphere) is positioned within the vacuum vessel by the remote handling (RH) system. Following the 2013 calibration runs, several changes were made to improve the efficiency and quality of the calibrations. Among these was the replacement of a 20 m “umbilical” cable which carried power and other electrical signals through a vessel port to/from a control cubicle. A lightweight 2 m cable now plugs directly into a single connector on the RH manipulator system, greatly reducing the time required for deployment and improving operational flexibility; e.g., the vessel access “floor” no longer needs to be installed. This change also means the system would be compatible with calibrations after a high neutron-fluence period of operation. An on-board micro-spectrometer now allows for real-time verification of the emitted spectrum. Finally, new “baffles” were designed and installed within the integrating sphere itself, greatly improving the spectral radiance uniformity at non-normal viewing angles (necessary due to orientation uncertainties with the RH system).

Conway, N. J.↗

Reliability of Open Public Electric Vehicle Direct Current Fast Chargers

The aim was to systematically evaluate the usability of all public electric vehicles (EV) direct current fast chargers (DCFC) in the San Francisco region. To achieve a rapid transition to EVs, a highly reliable and easy to use charging infrastructure is critical to building confidence among consumers. The functionality and usability of all 182 open, public DCFC charging stations with CCS connectors (combined charging system) in the 9 counties of the Bay Area were tested (655 electric vehicle service equipment (EVSE) ports). An EVSE was classified as functional if it charged an EV for 2 minutes. Overall, 73.3% of the 655 EVSEs were functional. The causes of the nonfunctioning EVSEs (23.5%) were blank or unresponsive screens or error messages; payment system failures; charge initiation failures; network failures; or broken connectors. In addition, the cable was too short to reach the EV inlet for 3.2% of the EVSEs. A random sampling of 10% of the EVSEs, approximately 8 days after the first evaluation, found no overall change in functionality. The level of functionality found with field testing conflicts with the 95–98% uptime reported by the EV service providers (EVSPs) who operate the EV charging stations. There is a need for precise and verifiable definitions of uptime, downtime, and excluded time, as applied to public EV chargers. In conclusion, the level of failure of the existing public EV DCFC charge infrastructure highlights the importance of improving the system design and maintenance to improve adoption of EVs.

33 ADVANCED PROPULSION SYSTEMS↗

Sensing The Position Of A Piston In A Cylinder

Position of piston in cylinder determined by series of ports and pressure-actuated electrical switches. Position-sensing scheme developed to help control movement of piston, which delivers fist-size objects to automatic mechanism at rate of less than 1 per second. Piston driven by either pressurized gas or hydraulic fluid. Position sensors have only fluid connections to cylinder. If cylinder or piston removed, not necessary to disturb electrical connections to switches. Scheme useful when electrical sensors create hazard or cause interference.

Wiker, Gordon A.↗

SPHERES Facility

Synchronized Position Hold, Engage, Reorient, Experimental Satellites (SPHERES) are bowling-ball sized satellites that provide a test bed for development and research into multi-body formation flying, multi-spacecraft control algorithms, and free-flying physical and material science investigations. Up to three self-contained free-flying satellites can fly within the cabin of the International Space Station (ISS), performing flight formations, testing of control algorithms or as a platform for investigations requiring this unique free-flying test environment. Each satellite is a self-contained unit with power, propulsion, computers, navigation equipment, and provides physical and electrical connections (via standardized expansion ports) for Principal Investigator (PI) provided hardware and sensors.

Material science investigations↗

Forecast analysis of optical waveguide bus performance

Elements to be considered in the design of a data bus include: architecture; data rate; modulation, encoding, detection; power distribution requirements; protocol, work structure; bus reliability, maintainability; interterminal transmission medium; cost; and others specific to application. Fiber- optic data bus considerations for a 32 port transmissive star architecture, are discussed in a tutorial format. General optical-waveguide bus concepts, are reviewed. The electrical and optical performance of a 32 port transmissive star bus, and the effects of temperature on the performance of optical-waveguide buses are examined. A bibliography of pertinent references and the bus receiver test results are included.

Ledesma, R.↗

Big Box Retail Grocery Store and Electric Vehicle Station Load Profiles

This dataset includes yearlong, one-minute resolution time series profiles for the big box retail grocery stores stores simulated in Phoenix, Houston, Denver, and Minneapolis, as well as electric vehicle charging time series profiles for the various ports, charging levels, and station utilizations produced for the study "Impact of electric vehicle charging on the power demand of retail buildings", published in 2021 (https://doi.org/10.1016/j.adapen.2021.100062). Please cite as: Gilleran, M., Bonnema, E., Woods, J. et al. Impact of electric vehicle charging on the power demand of retail buildings. Advances in Applied Energy 4, (2021). https://doi.org/10.1016/j.adapen.2021.100062

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Large-scale Hydrogen Storage – Risk Assessment Seattle City Light and Port of Seattle [Abstract]

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL), and the Port of Seattle (Port) in performing a risk assessment of large-scale hydrogen storage. Risk assessment is often used to ensure that adequate measures are taken to protect workers and the public, the environment, infrastructure, and assets. A detailed risk assessment can also be used to direct funding and upgrades, to specific components and sub-systems in order to mitigate risks to the larger system. In this way risk assessments are often employed as a part of a larger risk management strategy, with the goal of minimizing the occurrence of hazards and to identify means to limit their consequences. Risk assessment is often used to engage and inform regulators, and to communicate how specific regulations are being met. However, it is important to note that the proposed work is not intended for SCL and the Port to use in order to gain regulatory acceptance for their proposed activities. The work performed as a part of this effort will be a preliminary risk assessment for early-stage component and system designs and should be considered research and development (R&D). As such, the proposed work will be performed to a quality level and design maturity consistent with R&D and is not considered appropriate for final safety analysis and regulatory compliance purposes. Previous and on-going work at SCL and the Port demonstrated the utility of deploying hydrogen systems at the Port. The deployment of hydrogen at the Port is a part of a larger vision of using hydrogen to address a range of issues for SCL and the Port. These include large-scale fueling of MD/HD vehicles, cargo-handling equipment (CHE), and harbor vessels to reduce emissions; support of adjacent LD vehicles; support of critical port operations during extreme events (i.e., resiliency); deferral of more capital- and time-intensive electrical distribution system upgrades while still supporting evolving port operations and decarbonization efforts; facilitating electrification by establishing energy storage as a grid resource, starting at strategic port locations; creation of a flexible market resource that can be used by SCL to generate revenue via arbitrage; support of planned future maritime operations that involve heavy use of hydrogen for ocean-going vessels; and future end-use applications involving natural gas pipeline hydrogen injection. Ultimately, the success of these activities is underpinned by the deployed storage capacity. Large-scale deployment of hydrogen systems will require hydrogen storage at a scale that has not been demonstrated. In addition, the ideal location for such multi-use systems is near the end user which will often necessitate deploying into urban and/or industrial areas. A detailed risk assessment using the Port as a test case is necessary to ensure the deployment of large-scale hydrogen is successful. Many technologies have been proposed for hydrogen storage; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for the Port will be analyzed, and a risk assessment for compressed hydrogen, liquified hydrogen, and Liquid Organic Hydrogen Carrier (LOHC) storage will be performed. These risk assessments will be useful for understanding how each of these technologies would perform in terms of facility and public safety. The operating states of the proposed hydrogen systems at the Port will be analyzed and incorporated into the storage risk assessment. Scalability will also be analyzed to understand how future port uses would affect the overall risk assessment. Finally, using the risk assessment as a tool to inform engagement and to gain stakeholder acceptance will be explored.

08 HYDROGEN↗