Observed relationships between electric fields and auroral particle precipitation.

Simultaneous electric field and plasma observations with the low-altitude polar-orbiting satellite Injun 5 have provided a comprehensive survey of convection electric fields and their association with magnetospheric plasma phenomena. The most prominent features of the convection electric fields are reversals located at high magnetic latitudes, with generally antisunward convection poleward and sunward convection equatorward of the electric field reversal location. The electric field reversal is interpreted as the boundary between open and closed magnetic field lines. During local day the electric field reversal is observed to coincide with the equatorward boundary of the polar cusp. The plasma flow in the dayside polar cusp region is dominantly E-W, away from the stagnation point, the convection velocities typically being about 1 km/sec. At local evening, 'inverted V' electron precipitation bands are observed near or at the position of the electric field reversal. In the local late-evening sector the electric field reversal becomes less distinct, and often no single well-defined electric field reversal can be identified. In all cases the inverted V electron precipitation events are closely associated with large, typically greater than 30 mV/m, irregular electric field fluctuations with time scales of a few seconds or less.

Gurnett, D. A.

Direct comparison between satellite electric field measurements and the visual aurora

Electric field data from two passes of the Injun 5 satellite, one corresponding to magnetically quiet conditions and one corresponding to substorm conditions, are compared with simultaneous all-sky-camera data from College, Alaska. In each case, a significant deviation of the electric field from the expected V x B field (where V is the satellite velocity) was evident and a distinct electric field reversal could be identified. In the region of substantial electric field equatorward of the electric field reversal a diffuse auroral arc was observed during the magnetically quiet pass and auroral patches were observed during the substorm pass. The motion of the auroral patches was consistent with the general direction and magnitude of the E x B drift computed from the satellite electric field measurements. In the substorm case the electric field reversal occurred very near a discrete auroral arc at the poleward side of the diffuse arcs and patches. Comparison of the quiet time and substorm cases suggests that the convection electric field penetrates deeper into the magnetosphere during a substorm.

Swift, D. W.

Multi-Year Electric Field Study at the North Slope of Alaska (OYESNSA) Field Campaign Report

The Global Electric Circuit (GEC) of the atmosphere provides a unique perspective on Earth’s changing climate. Monitoring this global electrical signature provides details of the global nature of electrified clouds and thunderstorms. The North Slope of Alaska (NSA) is a unique location for collecting these electric field measurements. Besides being at the opposite pole from many previous electric field measurements taken at Russia’s Vostok station in Antarctica, this site provides a rare opportunity to use other instruments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s NSA observatory at Utqiaġvik (formerly known as Barrow), such as the Ka-band ARM Zenith Radar (KAZR), upward-facing micropulse lidar (MPL), vertical profile of meteorological measures, and other aerosol measurements. Since 2017, Texas A&M University at Corpus Christi (TAMUCC) has established an observational instrument package, including CS110 electric fields and anemometer, at ARM’s NSA observatory at Utqiaġvik. This enabled the unique opportunity to not only provide information about the global signature of the GEC, but also the physical inputs to the local electric field, by analyzing the physical properties of the simultaneous cloud, wind, and aerosol properties occurring with the vertical electric field.

54 ENVIRONMENTAL SCIENCES

Multi-Year Electric Field Study at the North Slope of Alaska (OYESNSA) Field Campaign Report

The Global Electric Circuit (GEC) of the atmosphere provides a unique perspective on Earth’s changing climate. Monitoring this global electrical signature provides details of the global nature of electrified clouds and thunderstorms. The North Slope of Alaska (NSA) is a unique location for collecting these electric field measurements. Besides being at the opposite pole from many previous electric field measurements taken at Russia’s Vostok station in Antarctica, this site provides a rare opportunity to use other instruments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s NSA observatory at Utqiaġvik (formerly known as Barrow), such as the Ka-band ARM Zenith Radar (KAZR), upward-facing micropulse lidar (MPL), vertical profile of meteorological measures, and other aerosol measurements. Since 2017, Texas A&M University at Corpus Christi (TAMUCC) has established an observational instrument package, including CS110 electric fields and anemometer, at ARM’s NSA observatory at Utqiaġvik. This enabled the unique opportunity to not only provide information about the global signature of the GEC, but also the physical inputs to the local electric field, by analyzing the physical properties of the simultaneous cloud, wind, and aerosol properties occurring with the vertical electric field.

54 ENVIRONMENTAL SCIENCES

Direct comparison between satellite electric field measurements and the visual aurora

Electric field data from two passes of the Injun 5 satellite, one corresponding to magnetically quiet conditions and one corresponding to substorm conditions, are compared with simultaneous all-sky camera data from College, Alaska. In each case, a significant deviation of the electric field from the expected V x B field (where V is the satellite velocity) was evident, and a distinct electric field reversal could be identified. In the region of substantial electric field equatorward of the electric field reversal, a diffuse auroral arc was observed during the magnetically quiet pass, and auroral patches were observed during the substorm pass. In the substorm case, the electric field reversal occurred very near a discrete auroral arc at the poleward side of the diffuse arcs and patches. Comparison of the quiet time and substorm cases suggests that the convection electric field penetrates deeper into the magnetosphere during a substorm.

Swift, D. W.

Magnetospheric electric fields and auroral oval

DC electric field variations in a synchronous orbit (GEOS 2) during four substorms in the time sector 19 to 01 LT were investigated. Simultaneously, the imaging photometer on board DE 1 provided auroral images that are also utilized. Substorm onset is defined here as a sudden appearance of large electric fields. During the growth phase, the orientation of the electric field begins to oscillate some 30 min prior to onset. About 10 min before the onset GEOS 2 starts moving into a more tenuous plasma, probably due to a thinning of the current sheet. The onset is followed by a period of 10 to 15 min during which large electric fields occur. This interval can be divided into two intervals. During the first interval, which lasts 4 to 8 min, very large fields of 8 to 20 mV/m are observed, while the second interval contains relatively large fields (2 to 5 mV/m). A few min after the onset, the spacecraft returns to a plasma region of higher electron fluxes which are usually larger than before substorm. Some 30 min after onset, enhanced activity, lasting about 10 min, appears in the electric field. One of the events selected offers a good opportunity to study the formation and development of the Westward Traveling Surge (WST). During the traversal of the leading edge of the WTS (approximately 8 min) a stable wave mode at 5.7 mHz is detected.

Laakso, Harri

Circulation in the high-latitude thermosphere due to electric fields and Joule heating

Electric fields in the earth's upper atmosphere are capable of setting the neutral atmosphere in motion via ion-neutral collisions as well as pressure gradients from resultant Joule heating. By means of simple models for the high-latitude thermosphere and electric fields a simplified set of coupled equations is solved which show that moderate electric fields, when present for a period of several hours, are capable of displacing the neutral atmosphere of the order of 50 km in the vertical, a few hundred kilometers in the north-south direction and over 1000 km in the east-west direction.

Heaps, M. G.

Observed relationships between electric fields and auroral particle precipitation

Simultaneous electric field and plasma observations with the low altitude, polar orbiting satellite Injun (Hawkeye) 5 provided a comprehensive survey of convection electric fields and their association with magnetospheric plasma phenomena. The most prominent features of the convection electric fields are reversals located at high magnetic latitudes, with generally anti sunward convection poleward convection equatorward of the electric field reversal location. The electric field reversal is interpreted as the boundary between open and closed magnetic field lines. To investigate the electric field and plasma interrelationships during a polar magnetic substorm, a series of passes obtained prior to and during a substrom is presented. Large, anti sunward convection velocities were detected over the polar cap several tens of minutes before the onset of the expansive phase of the substrom. These convection velocities gradually decreased during the decay phase of the substrom. Measurements of enhanced anti sunward flow over the polar cap region are generally consistent with concepts of the origin of substroms.

Gurnett, D. A.

Turbulent electric fields in the nightside magnetosphere

Electric field measurements from the long-wire double-probe instrument (baseline of 179 m) on ISEE 1 have shown the magnetospheric electric field on auroral L shells to be extremely turbulent during periods of magnetic activity. During intense activity these turbulent electric fields can penetrate to very low L values. The variational component of the electric field is typically larger than the DC value. Measurements are presented at frequencies up to 14 Hz. Magnitudes of over 40 m V/m (zero to peak) have been observed with spectral power levels in the 1-10 Hz range greater than m squareV/sq m Hz. The spectral shape of the most intense events was generally flatter than that predicted by two-dimensional hydromagnetic cascading of energy, which argues that the source of this turbulence must be driving the plasma near these frequencies. This in turn suggests that the instability is in the low-energy plasma.

Maynard, N. C.

Aircraft measurement of electric field - Self-calibration

Aircraft measurement of electric fields is difficult as the electrically conducting surface of the aircraft distorts the electric field. Calibration requires determining the relations between the undistorted electric field in the absence of the vehicle and the signals from electric field meters that sense the local distorted fields in their immediate vicinity. This paper describes a generalization of a calibration method which uses pitch and roll maneuvers. The technique determines both the calibration coefficients and the direction of the electric vector. The calibration of individual electric field meters and the elimination of the aircraft's self-charge are described. Linear combinations of field mill signals are examined and absolute calibration and error analysis are discussed. The calibration method was applied to data obtained during a flight near thunderstorms.

Winn, W. P.

Inductive electric field at the magnetopause

The electric field data for two crossings of the magnetopause by ISEE-1 on November 20, 1977, have been analyzed with high time resolution. In both cases the electric field has a negative dawn-dusk component in the boundary layer, so it must reverse somewhere within the current layer to the positive value outside. If there is a component parallel to the moving magnetopause current it is small, and by no means obvious. In the case of the exit crossing from the boundary layer to the magnetosheath the data show that the electric field vector is turning for about two seconds at roughly the satellite spin rate; this changing direction suggests that the electric field has a curl. Such a curl could be caused by a travelling localized perturbation of the magnetopause surface current associated with impulsive plasma transport through the magnetopause.

Heikkila, W. J.

An interplanetary magnetic field dependent model of the ionospheric convection electric field

An IMF-dependent model of the magnetospheric electric field at ionospheric altitudes has been developed based on published observations, qualitative models, and a limited understanding of the electric field source. The empirical inputs are discussed, and the model is presented in an ionospheric convection situation where corotation is an important ingredient. This leads to a description of sunward ionospheric plasma transport in the polar cap for northward IMF orientations. The validity of the model is discussed, and areas in which more empirical results are required are specified.

Sojka, J. J.

Analysis of DE-1 PWI electric field data

The measurement of low frequency electric field oscillations may be accomplished with the Plasma Wave Instrument (PWI) on DE 1. Oscillations at a frequency around 1 Hz are below the range of the conventional plasma wave receivers, but they can be detected by using a special processing of the quasi-static electric field data. With this processing it is also possible to determine if the electric field oscillations are predominately parallel or perpendicular to the ambient magnetic field. The quasi-static electric field in the DE 1 spin/orbit plane is measured with a long-wire 'double probe'. This antenna is perpendicular to the satellite spin axis, which in turn is approximately perpendicular to the geomagnetic field in the polar magnetosphere. The electric field data are digitally sampled at a frequency of 16 Hz. The measured electric field signal, which has had phase reversals introduced by the rotating antenna, is multiplied by the sine of the rotation angle between the antenna and the magnetic field. This is called the 'perpendicular' signal. The measured time series is also multiplied with the cosine of the angle to produce a separate 'parallel' signal. These two separate time series are then processed to determine the frequency power spectrum.

Weimer, Daniel

Summary of Almost 20 Years of Storm Overflight Electric Field, Conductivity, Flash Rates, and Electric Current Statistics

We determined total conduction currents and flash rates for around 900 high-altitude aircraft overflights of electrified clouds over 17 years. The overflights include a wide geographical sample of storms over land and ocean, with and without lightning, and with positive (i.e., upward-directed) and negative current. Peak electric field, with lightning transients removed, ranged from -1.0 kV m(sup -1) to 16. kV m(sup -1), with mean (median) of 0.9 kV m(sup -1) (0.29 kV m(sup -1)). Total conductivity at flight altitude ranged from 0.6 pS m(sup -1) to 3.6 pS m(sup -1), with mean and median of 2.2 pS m(sup -1). Peak current densities ranged from -2.0 nA m(sup -2) to 33.0 nA m(sup -2) with mean (median) of 1.9 nA m(sup -2) (0.6 nA m(sup -2)). Total upward current flow from storms in our dataset ranged from -1.3 to 9.4 A. The mean current for storms with lightning is 1.6 A over ocean and 1.0 A over land. The mean current for electrified shower clouds (i.e. electrified storms without lightning) is 0.39 A for ocean and 0.13 A for land. About 78% (43%) of the land (ocean) storms have detectable lightning. Land storms have 2.8 times the mean flash rate as ocean storms (2.2 versus 0.8 flashes min(sup -1), respectively). Approximately 7% of the overflights had negative current. The mean and median currents for positive (negative) polarity storms are 1.0 and 0.35 A (-0.30 and -0.26 A). We found no regional or latitudinal-based patterns in our storm currents, nor support for simple scaling laws between cloud top height and lightning flash rate.

Blakeslee, Richard J.

Observations of ULF electric field fluctuations in the dayside auroral oval

Electric field oscillations at frequencies centered below 10 Hz were measured by a payload equipped with double-probe electric field detectors which was launched into the dayside auroral oval during the Greenland rocket campaign on January 11, 1975. These oscillations exceeded an amplitude of 3 mV/m broadband and occurred over a period of about 90 s. These oscillations occurred during a proton injection event when the quasi-static electric field was less than 20 mV/m on the average. However, during a brief 2-s interval the electric field exceeded 50 mV/m. Analysis of the amplitude as a function of the spin frequency showed that the electric field was confined to a plane perpendicular to the magnetic field. The power spectrum was of the form f to the -6.5 + or - 1.5 power, where f is the frequency over the range from 8 to 18 Hz. The existence of a large electric field fluctuation in a spatially or temporally confined region of low-amplitude turbulence suggests that this may be an observation of the low-altitude projection of a turbulent region associated with electrostatic shocks which have recently been observed at higher altitudes.

Temerin, M.

Airborne observations of electric fields around growing and decaying cumulus clouds

Airborne electric field data were gathered in an atmospheric electrification study near Cape Canaveral, FL. A Learjet 36A was instrumented with eight electric field meters (mills) and five different particle probes. The local electric field enhancements at each field mill site were determined under lab conditions and verified using in-flight data. The overdetermined system of eight equations (one for each field mill) was solved using a weighted least squares algorithm to compute the magnitude and direction of the ambient electric field. The signal processing system allowed the measured data to be expressed in terms of earth coordinates, regardless of the attitude of the aircraft. Thus, it was possible to take maximum advantage of the Learjet's speed and maneuverability in studying the electric field structure in the vicinity of the clouds. Data gathered while circling just outside the boundary of a growing cumulus cloud show a nonsymmetric pattern of electric field strength. Field intensity grew rapidly over a period of less than 10 minutes. The observed direction of the ambient electric field vector can be explained by an ascending motion of the charge centers of a classic tripole model of a thunderstorm.

Giori, K. L.

Comparison of high-latitude and mid-latitude ionospheric electric fields

Simultaneous measurements of the F region electric field by the incoherent scatter technique have been made at Chatanika, Alaska (65.1 deg N, 147.5 deg W), and Millstone Hill, Massachusetts (42.6 deg N, 71.5 deg W), on July 18-19 and Aug. 7-8, 1973. Good correlation was observed in the time variation of the perpendicular electric field at the two stations. Magnetic conditions for these days were relatively quiet with some variations evident from the high-latitude magnetograms and the Chatanika radar, but no distinct effect appeared on the mid-latitude magnetograms. Since magnetospheric electric fields are thought to be the source of high-latitude electric fields such as those observed at Chatanika, the good correlation in the perpendicular electric field for the two stations indicates that the magnetospheric originated electric fields have an appreciable effect down to at least L equals 3.2.

Carpenter, L. A.