Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Echocardiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automated assessment of noninvasive filling pressure using color Doppler M-mode echocardiography

Assessment of left ventricular filling pressure usually requires invasive hemodynamic monitoring to follow the progression of disease or the response to therapy. Previous investigations have shown accurate estimation of wedge pressure using noninvasive Doppler information obtained from the ratio of the wave propagation slope from color M-mode (CMM) images and the peak early diastolic filling velocity from transmitral Doppler images. This study reports an automated algorithm that derives an estimate of wedge pressure based on the spatiotemporal velocity distribution available from digital CMM Doppler images of LV filling.

Non-NASA Center↗

Inferior vena caval masses identified by echocardiography

The most common cause of an inferior vena caval mass is renal cell carcinoma that extends through the lumen, occurring in 47 of 62 patients (85%). Detection of an inferior vena caval mass affects the surgical approach requiring cardiopulmonary bypass for resection when the mass extends to the heart.

NASA Discipline Cardiopulmonary↗

Sector-scanning echocardiography

The mechanical sector scanner is described in detail, and its clinical application is discussed. Cross sectional images of the heart are obtained in real time using this system. The sector scanner has three major components: (a) hand held scanner, (b) video display, and (c) video recorder. The system provides diagnostic information in a wide spectrum of cardiac diseases, and it quantitates the severity of mitral stenosis by measurement of the mitral valve orifice area in diagnosing infants, children and adults with cyanotic congenital heart disease.

Henry, W. L.↗

Assessment of left ventricular ejection fraction by radionuclide angiography. Comparison to echocardiography and serial measurements in patients with myocardial infarction

Measurements of the left ventricular ejection fraction were compared in patients with previous myocardial infarctions. Left ventricular ejection fraction was measured by the radioisotopic method serially in patients early after an acute myocardial infarction and during the convalescence period. Ultrasound recordings were obtained utilizing a commercially available ultrasonoscope and a 1/9 cm transducer focused at 10 cm with a repetition rate of 1000 impulses per second. All recordings were made on a visicorder oscillography.

Schelbert, H. R.↗

High-resolution echocardiography

High resolution computer aided ultrasound system provides two-and three-dimensional images of beating heart from many angles. System provides means for determining whether small blood vessels around the heart are blocked or if heart wall is moving normally without interference of dead and noncontracting muscle tissue.

Nathan, R.↗

Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

Buckey, J. C.↗

New imaging technology: measurement of myocardial perfusion by contrast echocardiography

Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

NASA Program Biomedical Research and Countermeasur↗

An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P <.0001). In contrast to the mitral inflow velocities, mitral annulus early diastolic velocity decreased steadily (12.3-7.3 cm/s) resulting in a dramatic decrease in mitral annulus early/late (1.22-0.57) diastolic velocity with no tendency toward pseudonormalization. The color M-mode Doppler flow propagation velocity also showed significant steady decrease (57-24 cm/s) throughout the pacing period. Multiple regression analysis chose mitral annulus systolic velocity (r = 0.895, P <.0001) and propagation velocity (r = 0.782, P <.0001) for the most important factor predicting LV systolic and diastolic function, respectively. CONCLUSIONS: Doppler tissue echocardiography and color M-mode Doppler flow could evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

Evaluation Studies↗

Clinical and echocardiographic characteristics of papillary fibroelastomas: a retrospective and prospective study in 162 patients

BACKGROUND: Cardiac papillary fibroelastoma (CPF) is a primary cardiac neoplasm that is increasingly detected by echocardiography. The clinical manifestations of this entity are not well described. METHODS AND RESULTS: In a 16-year period, we identified patients with CPF from our pathology and echocardiography databases. A total of 162 patients had pathologically confirmed CPF. Echocardiography was performed in 141 patients with 158 CPFs, and 48 patients had CPFs that were not visible by echocardiography (<0.2 cm), leaving an echocardiographic subgroup of 93 patients with 110 CPFs. An additional 45 patients with a presumed diagnosis of CPF were identified. The mean age of the patients was 60+/-16 years of age, and 46.1% were male. Echocardiographically, the mean size of the CPFs was 9+/-4.6 mm; 82.7% occurred on valves (aortic more than mitral), 43.6% were mobile, and 91.4% were single. During a follow-up period of 11+/-22 months, 23 of 26 patients with a prospective diagnosis of CPF that was confirmed by pathological examination had symptoms that could be attributable to embolization. In the group of 45 patients with a presumed diagnosis of CPF, 3 patients had symptoms that were likely due to embolization (incidence, 6.6%) during a follow-up period of 552+/-706 days. CONCLUSIONS: CPFs are generally small and single, occur most often on valvular surfaces, and may be mobile, resulting in embolization. Because of the potential for embolic events, symptomatic patients, patients undergoing cardiac surgery for other lesions, and those with highly mobile and large CPFs should be considered for surgical excision.

NASA Discipline Cardiopulmonary↗

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

NASA Discipline Cardiopulmonary↗

Echocardiographic assessment of cardiac disease

The physical principles and current applications of echocardiography in assessment of heart diseases are reviewed. Technical considerations and unresolved points relative to the use of echocardiography in various disease states are stressed. The discussion covers normal mitral valve motion, mitral stenosis, aortic regurgitation, atrial masses, mitral valve prolapse, and idiopathic hypertrophic subaortic stenosis. Other topics concern tricuspic valve abnormalities, aortic valve disease, pulmonic valve, pericardial effusion, intraventricular septal motion, and left ventricular function. The application of echocardiography to congenital heart disease diagnosis is discussed along with promising ultrasonic imaging systems. The utility of echocardiography in quantitative evaluation of cardiac disease is demonstrated.

Popp, R. L.↗

Frequency of Atrial Septal Aneurysms in Patients with Cerebral Ischemic Events

Background-Atrial septal aneurysm (ASA) is a putative risk factor for cardioembolism. However, the frequency of ASA in the general population has not been adequately determined. Therefore, the frequency in patients with cerebral ischemic events, compared with the frequency in the general population, is poorly defined. We sought to determine the frequency of ASA in the general population and to compare the frequency of ASA in patients with cerebral ischemic events with the frequency in the general population. Methods and Results-The frequency of ASA in the population was determined in 363 subjects, a sample of the participants in the Stroke Prevention: Assessment of Risk in a Community study (control subjects), and was compared with the frequency in 355 age- and sex-matched patients undergoing transesophageal echocardiography in search of a cardiac source of embolism after a focal cerebral ischemic event. The proportion with ASA was 7.9% in patients versus 2.2% in control subjects (P=0.002; odds ratio of ASA, 3.65; 95% CI, 1.64 to 8.13, in patients versus control subjects). Patent foramen ovale (PFO) was detected with contrast injections in 56% of subjects with ASA. The presence of ASA predicted the presence of PFO (odds ratio of PFO, 4.57; 95% CI, 2.18 to 9.57, in subjects with versus those without ASA). In 86% of subjects with ASA and cerebral ischemia, transesophageal echocardiography did not detect an alternative source of cardioembolism other than an associated PFO. Conclusions-The prevalence of ASA based on this population-based study is 2.2%. The frequency of ASA is relatively higher in patients evaluated with transesophageal echocardiography after a cerebral ischemic event. ASA is frequently associated with PFO, suggesting paradoxical embolism as a mechanism of cardioembolism. In patients with cerebral ischemia and ASA, ASA (with or without PFO) commonly is the only potential cardioembolic source detected with transesophageal echocardiography.

Agmon, Yoram↗

Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

NASA Discipline Cardiopulmonary↗

Intraoperative echocardiographic detection of regurgitant jets after valve replacement

BACKGROUND: Paravalvular jets, documented by intraoperative transesophageal echocardiography, have prompted immediate valve explantation by others, yet the significance of these jets is unknown. METHODS: Twenty-seven patients had intraoperative transesophageal two-dimensional color Doppler echocardiography, performed to assess the number and area of regurgitant jets after valve replacement, before and after protamine. Patients were grouped by first time versus redo operation, valve position and type. RESULTS: Before protamine, 55 jets were identified (2.04+/-1.4 per patient) versus 29 jets after (1.07+/-1.2 per patient, p = 0.0002). Total jet area improved from 2.0+/-2.2 cm2 to 0.86+/-1.7 cm2 with protamine (p<0.0001). In all patients jet area decreased (average decrease, 70.7%+/-27.0%). First time and redo operations had similar improvements in jet number and area (both p>0.6). Furthermore, mitral and mechanical valves each had more jets and overall greater jet area when compared to aortic and tissue valves, respectively. CONCLUSIONS: Following valve replacement, multiple jets are detected by intraoperative transesophageal echocardiography. They are more common and larger in the mitral position and with mechanical valves. Improvement occurs with reversal of anticoagulation.

Non-NASA Center↗

Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study

OBJECTIVES: The aim of this study was to use real-time three-dimensional echocardiography (3DE) to investigate the quantitative relation between minimal left ventricular (LV) outflow tract area (A(LVOT)) and maximal LV outflow tract (LVOT) velocity in patients with hypertrophic obstructive cardiomyopathy (HCM). BACKGROUND: In patients with HCM, LVOT velocity should change inversely with minimal A(LVOT) unless LVOT obstruction reduces the pumping capacity of the ventricle. METHODS: A total of 25 patients with HCM with systolic anterior motion (SAM) of the mitral valve leaflets underwent real-time 3DE. The smallest A(LVOT) during systole was measured using anatomically oriented two-dimensional "C-planes" within the pyramidal 3DE volume. Maximal velocity across LVOT was evaluated by two-dimensional Doppler echocardiography (2DE). For comparison with 3DE A(LVOT), the SAM-septal distance was determined by 2DE. RESULTS: Real-time 3DE provided unique information about the dynamic SAM-septal relation during systole, with A(LVOT) ranging from 0.6 to 5.2 cm(2) (mean: 2.2 +/- 1.4 cm(2)). Maximal velocity (v) correlated inversely with A(LVOT) (v = 496 A(LVOT)(-0.80), r = -0.95, p < 0.001), but the exponent (-0.80) was significantly different from -1.0 (95% confidence interval: -0.67 to -0.92), indicating a significant impact of small A(LVOT) on the peak LVOT flow rate. By comparison, the best correlation between velocity and 2DE SAM-septal distance was significantly (p < 0.01) poorer at -0.83, indicating the superiority of 3DE for assessing A(LVOT). CONCLUSIONS: Three-dimensional echocardiography-measured A(LVOT) provides an assessment of HCM geometry that is superior to 2DE methods. These data indicate that the peak LVOT flow rate appears to be significantly decreased by reduced A(LVOT). Real-time 3DE is a potentially valuable clinical tool for assessing patients with HCM.

NASA Discipline Cardiopulmonary↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗