Analysis and Experimental Tests of a High-Performance Evacuated Tubular Collector

A high-performance collector based on the use of all-glass, evacuated tubular collector elements is described and analyzed, and supporting experimental data presented. The collector operated with excellent efficiency at temperatures high enough to drive existing air conditioning units, and showed good performance under diffuse light and low insolation conditions. Collector efficiency was insensitive to operating temperature, ambient temperature, and wind speed. In addition, air, as well as liquid, can be used as the heat transfer fluid, with no significant performance penalty. While the equations governing the useful energy produced can be cast in a form similar to that for flat plate collectors, several important parameters were unique in a number of respects. The loss coefficient was unusually low, while the flow factor and effective insolation were unusually high.

Beekley, D. C.↗

Modified Evacuated-Tube Collector Tested in Solar Simulator

According to report, particular commercial evacuated-tube solar collector performs slightly more efficiently with larger manifold. Tests were performed with Marshall Space Flight Center solar simulator. Report describes test conditions and procedures, provides analysis of results, and presents tables and graphs of data, both measured and calculated.

Source record↗

Evaluation of All-Day-Efficiency for selected flat plate and evacuated tube collectors

An evaluation of all day efficiency for selected flat plate and evacuated tube collectors is presented. Computations are based on a modified version of the NBSIR 78-1305A procedure for all day efficiency. The ASHMET and NOAA data bases for solar insolation are discussed. Details of the algorithm used to convert total (global) horizontal radiation to the collector tilt plane of the selected sites are given along with tables and graphs which show the results of the tests performed during this evaluation.

Source record↗

Safe Emergency Evacuation From Tall Structures

Emergency egress system allows people to be evacuated quickly from tall structures. New emergency system applicable to rescues from fires in tall hotels and other buildings. System consists of basket on slide wire. Basket descends by gravity on sloped slide wire staked to ground.

Stephan, E. S.↗

A user-operated model to study strategy in aircraft evacuation

A computer model is described to study strategies used by passengers evacuating a burning aircraft. Two baseline cases are presented to demonstrate the model. In the first case, in a simple scenario, strategies were found to change from even movement to the nearest exit to others farthest from the fire. In the second case, a test studying the effects of obstacles on passenger movement, nonlinear effects were found that may increase the time required to escape. The presence of obstacles created bottlenecks and, in some cases, isolated whole sections of the passenger cabin, making it impossible to escape. This occurred even though exits were still available for escape, but passengers could not reach them.

Cagliostro, D. E.↗

Experimental evaluation of blockage ratio and plenum evacuation system flow effects on pressure distribution for bodies of revolution in 0.1 scale model test section of NASA Lewis Research Center's proposed altitude wind tunnel

An experimental investigation was conducted in the slotted test section of the 0.1-scale model of the proposed Altitude Wind Tunnel to evaluate wall interference effects at tunnel Mach numbers from 0.70 to 0.95 on bodies of revolution with blockage rates of 0.43, 3, 6, and 12 percent. The amount of flow that had to be removed from the plenum chamber (which surrounded the slotted test section) by the plenum evacuation system (PES) to eliminate wall interference effects was determined. The effectiveness of tunnel reentry flaps in removing flow from the plenum chamber was examined. The 0.43-percent blockage model was the only one free of wall interference effects with no PES flow. Surface pressures on the forward part of the other models were greater than interference-free results and were not influenced by PES flow. Interference-free results were achieved on the aft part of the 3- and 6-percent blockage models with the proper amount of PES flow. The required PES flow was substantially reduced by opening the reentry flaps.

Burley, Richard R.↗

Adjustable mount for electro-optic transducers in an evacuated cryogenic system

The invention is an adjustable mount for positioning an electro-optic transducer in an evacuated cryogenic environment. Electro-optic transducers are used in this manner as high sensitivity detectors of gas emission lines of spectroscopic analysis. The mount is made up of an adjusting mechanism and a transducer mount. The adjusting mechanism provided five degrees of freedom, linear adjustments and angular adjustments. The mount allows the use of an internal lens to focus energy on the transducer element thereby improving the efficiency of the detection device. Further, the transducer mount, although attached to the adjusting mechanism, is isolated thermally such that a cryogenic environment can be maintained at the transducer while the adjusting mechanism remains at room temperature. Radiation shields also are incorporated to further reduce heat flow to the transducer location.

Crossley, Edward A., Jr.↗

A computer-based Safety Assessment for Flight Evacuation - SAFE

The Safety Assessment for Flight Evacuation (SAFE) system has been developed for the computerized evaluation of safety in civil Emergency Medical Service (EMS) operations. The speed of the microprocessor used to analyze data allows many individual factors to be considered, as well as the interactions among those factors. SAFE's data base is structured as if-then conditional statements. SAFE also allows the most important of the factors to be given greater weight in the final score. The questionnaire filled by EMS crews encompassed mission-, crew-, organization-, environment-, and aircraft-related factors; each of these was subdivided into as many as eight variables affecting the EMS-mission risk of that factor.

Shively, Robert J.↗

Trapped-particle evacuation - Source of magnetotail bursts and tailward flows?

Observational and theoretical evidence that the polar cap can expand rapidly enough during the growth phase of a substorm to release geomagnetically trapped particles from previously closed drift shells, enabling the particles to escape into the tail, are examined. Observations show that the moving separatrix can overtake convecting nightside plasma during intervals of polar-cap expansion. Models of this phenomenon suggest that closed nightside field lines can be evaculated of their particle populations, and it is noted that such evacuations can account for the occurrence of energetic-particle bursts in the tail.

Lyons, L. R.↗

Braided composite bore evacuator chambers for tank cannons

Typically, continuous filament composite components are fabricated using a filament winding technique. In this operation, fibers are introduced to a rotating mandrel while a guide holding the material traverses back and forth to place the material in a helical pattern over the surface of the mandrel. This procedure is continued until complete coverage is obtained. An alternative method for fabricating continuous filament composite components is braiding. In the braiding operation a mandrel is traversed through the center of the braider while 144 strands of material traverse around a carrier ring. As the fibers are applied to a mandrel surface, 72 carriers holding the fibers travel clockwise, while another 72 carriers travel counterclockwise to interlock fibers. An additional 72 carriers located on the back of the braider introduce longitudinal fibers to the composite giving the composite lateral strength. The goal of using the braider is to reduce production time by simultaneously applying 144 strands of material onto a mandrel as opposed to the four-strand wrapping most filament winding techniques offer. Benefits to braiding include the ability to (1) introduce longitudinal fibers to the composite structure; (2) fabricate non-symmetric components without using complex functions to produce full coverage; and (3) produce a component with a higher degree of damage tolerance due to the interlocking of fibers. The fabrication of bore evacuator chambers for a tank cannon system is investigated by utilizing a 144 carrier braiding machine, an industrial robot, and a resin applicator system.

Wheeler, Philip C.↗

Evacuated FM08 Fuses Carry a Sustained Arc in a Bus over 75 VDC

The FM08 style fuse is specified to interrupt an overcurrent of up to 300 A in a bus of up to 125 VDC, but this applies only when its barrel is filled with air. When placed into a space-grade vacuum, the FM08 style fuse exhausts its air within a year. Then, the probability of an enduring arc is high for all ratings when the bus is above 75 VDC, and the overcurrent is large. The arc endures until something else interrupts the current. The fuse can violently eject metal vapor or other material during the sustained arcing. The evacuated FM08 does not develop a sustained arc when interrupted in a bus of 38 VDC or less, at least when there is little inductance in the circuit. This is consistent with its successful use in many spacecraft having buses in the range 24 to 36 volts.

Leidecker, Henning↗

Fluid Transient Analysis During Priming of Evacuated Line

Pressure surges are critical in the design of spacecraft propellant feed lines. The pressure transients that occur during priming of feed lines are very important in the design and analysis of liquid propulsion systems. During the start-up of the propulsion system of a spacecraft, the process of filling of an evacuated pipeline is called priming. Priming can generate severe pressure peaks due to the slam (water hammer) of the propellant against a closed thruster valve. The downstream conditions strongly affect the pressure surge. In space systems, satellites, or interplanetary probes, the propellant lines are vacuum-pumped or filled with low pressure helium or nitrogen before the launch. Before operations, these lines are primed with a vaporizing liquid, sometimes in the presence of a non-condensable gas (NCG), which produces water hammer phenomena. The objective of the current study is to use a finite volume based network flow solver (Generalized Fluid System Simulation Program, GFSSP) for the numerical simulation of Priming in (a) a straight feedline and (b) a flow network. The geometrical configurations and dimensions for the pipe and other components used for the current study are identical to experimental study of Prickett et al.

Bandyopadhyay, Alak↗

Evacuation and Shelter Plans for Asteroid Impacts

Lessons from Analogs - Hurricanes - Forecasting in time to take action - Large scale evacuations - Risk tolerance - Nuclear Explosions - Effects of large blast waves - Shelters - Fatality rates Application to Asteroid Impacts - PDC 2021: small, little warning, poorly constrained - PDC 2023: large, well characterized

ATAP↗

Evacuated displacement compression molding

A process for molding long, thin-wall tubular bodies from thermosetting plastic molding compounds is described. The tubular bodies produced may have body lengths several times the diameters. The application of the process for manufacturing rocket engine cases and nozzles is discussed. The advantages of the system over other methods of circular tube manufacture are analyzed.

W C Heier↗

Solar collector performance evaluation with the NASA-Lewis solar simulator-results for an all-glass-evacuated-tubular selectively-coated collector with a diffuse reflector

A solar collector was tested in a solar simulator for inlet temperatures of temperatures of 70 to 200 F, flux levels of 230 and rate of 7 lb/(hr)(sq. ft), and incident angles of 0 deg, 33 deg, and 52 deg. Test results plotted in a form suggested by analysis indicate a very low heat loss coefficient. The collector shows excellent performance on an all-day performance basis, and also for conditions corresponding to temperatures required in solar Rankine systems and/or for low flux level radiation.

Simon, F.↗