Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESCOs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Turf Conversion Measurement and Verification Protocol

This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings as a result of water conservation measures (WCMs) in energy performance contracts associated with converting turfgrass or other water-intensive plantings to water-wise and sustainable landscapes. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

13 HYDRO ENERGY↗

Outdoor Irrigation Measurement and Verification Protocol

This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.

13 HYDRO ENERGY↗

Outdoor Irrigation Measurement and Verification Protocol

This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.

13 HYDRO ENERGY↗

Cooling Tower (Evaporative Cooling System) Measurement and Verification Protocol

This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with cooling tower efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

13 HYDRO ENERGY↗

Cooling Tower (Evaporative Cooling System) Measurement and Verification Protocol

This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with cooling tower efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

13 HYDRO ENERGY↗

Reported Energy and Cost Savings from the DOE ESPC Program: FY 2016

The objective of this work was to determine the realization rate of energy and cost savings from the U.S. Department of Energy’s (DOE’s) Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. In formation was extracted from 172 measurement and verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reported Energy and Cost Savings from the DOE ESPC Program: FY 2019

The objective of this work was to determine the realization rate of energy and cost savings from the U.S. Department of Energy’s (DOE’s) Indefinite Delivery Indefinite Quantity (IDIQ) Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal facilities. In formation was extracted from 187 measurement and verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transforming Public Housing with Deep Energy Retrofits

Open Market ESCO’s (OME) Transforming Public Housing through Deep Energy Retrofits project demonstrated new design and financing solutions for implementing deep energy retrofits (DERs) in occupied low-income multifamily housing. The Project performed an integrated project delivery process, including designing low-carbon retrofit solution packages, construction pricing, and financing. The Project developed a constructible and financeable DER scope for a 102-unit extremely low-income multifamily property in Boston. This Project demonstrated a replicable approach for streamlining and implementing DER projects in occupied housing, including real solutions for overcoming design complexities and cost barriers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2020

The objective of this work was to determine the realization rate of energy and cost savings from the U.S. Department of Energy’s (DOE’s) Indefinite Delivery Indefinite Quantity (IDIQ) Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal facilities. In formation was extracted from 195 measurement and verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY2021

The objective of this work was to determine the realization rate of energy and cost savings from the U.S. Department of Energy’s (DOE’s) Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 201 measurement and verification (M&V) reports covering 193 projects to determine reported, estimated, and guaranteed cost savings and the associated reported and estimated energy savings for the previous contract performance year. This report covers projects that had a performance year ending in fiscal year 2021, between October 1, 2020 and September 30, 2021, and had an M&V report issued. Additionally, the annual cost to perform M&V was extracted from the individual project Task Order (TO) Schedules.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2022

The objective of this work was to determine the realization rate of energy and cost savings from the U.S. Department of Energy’s (DOE’s) Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 190 measurement and verification (M&V) reports covering 182 projects to determine reported, estimated, and guaranteed cost savings and the associated reported and estimated energy savings for the previous contract performance year. This report covers projects that had a performance year ending in fiscal year 2021, between October 1, 2021 and September 30, 2022, and had an M&V report issued. Additionally, the annual cost to perform M&V was extracted from the individual project Task Order (TO) Schedules.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2023

The objective of this work was to determine the realization rate of energy and cost savings from the U.S. Department of Energy’s (DOE’s) Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 201 measurement and verification (M&V) reports covering 191 projects to determine reported, estimated, and guaranteed cost savings and the associated reported and estimated energy savings for the previous contract performance year. This report covers projects that had a performance year ending in fiscal year 2023, between October 1, 2022 and September 30, 2023, and had an M&V report issued. Additionally, the annual cost to perform M&V was extracted from the individual project Task Order (TO) Schedules.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

SCOSII: ESA's new generation of mission control systems: The user's perspective

In 1974 ESOC decided to develop a reusable Mission Control System infrastructure for ESA's missions operated under its responsibility. This triggered a long and successful product development line, which started with the Multi Mission Support System (MSSS) which entered in service in 1977 and is still being used today by the MARECS and ECS missions; it was followed in 1989 by a second generation of systems known as SCOS-I, which was/is used by the Hipparcos, ERS-1 and EURECA missions and will continue to support all future ESCO controlled missions until approximately 1995. In the meantime the increasing complexity of future missions together with the emergence of new hardware and software technologies have led ESOC to go for the development of a third generation of control systems, SCOSII, which will support their future missions up to at least the middle of the next decade. The objective of the paper is to present the characteristics of the SCOSII system from the perspective of the mission control team; i.e. it will concentrate on the improvements and advances in the performance, functionality and work efficiency of the system.

Kaufeler, P.↗

NASA Glenn Research Center Experience Using DOE Midwest Region Super ESPC

The energy crisis of 1973 prompted the Federal Government and private industry to look into alternative methods to save energy. At the same time the constant reduction of operations and maintenance funds during the last 5 years forced Glenn Research Center (GRC) to look for alternative funding sources to meet the mandate to reduce energy consumption. The Super Energy Savings Performance Contract (ESPC) was chosen as a viable source of facility improvement funding that can create larger project scope and help replace aging, inefficient equipment. This paper describes Glenn's participation in the Department of Energy (DOE) Super ESPC program. This program provided Glenn cost savings in the performance of energy audits, preparation of documents, evaluation of proposals, and selection of energy service company (ESCO).

Zala, Laszlo F.↗