Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Improving evapotranspiration computation with electrical resistivity tomography in a maize field

Abstract Hydrogeophysical methods have been increasingly used to study subsurface soil–water dynamics, yet their application beyond the soil compartment or the quantitative link to soil hydraulic properties remains limited. To examine how these methods can inform model‐based evapotranspiration (ET) calculation under varying soil water conditions, we conducted a pilot‐scale field study at an experimental maize plot with manipulated irrigation treatments. Our goal was to develop a workflow for (1) acquiring and inverting field electrical resistivity tomography (ERT) data, (2) correlating ERT to soil hydraulic properties, (3) spatially characterizing soil water stress that feeds into ET modeling (the FAO‐56 model), and (4) evaluating the performance of ERT‐based ET computation. Our results showed that ERT was able to capture decimeter‐scale soil water content (SWC) dynamics from root water uptake and irrigation manipulation and the contrast of soil water stress between deficiently and fully irrigated maize. We also demonstrated the flexibility of using ERT to spatially integrate soil water stress in the soil volume of interest, which could be adjusted based on different crops and plot layouts. The integration of the ERT datasets into ET modeling provided insights into the spatial heterogeneity of the subsurface that has been challenging for point‐based sensing, which can further our understanding of the hydraulic dynamics in the soil‐plant‐atmosphere continuum.

54 ENVIRONMENTAL SCIENCES↗

Interpretation of large‐scale, long‐term electrical geophysical monitoring guided by a process simulation

Abstract Surface electrical resistivity tomography (ERT) was used at a waste site to monitor vadose zone changes in electrical properties as a proxy for contaminant flux over a span of 17 years. The BC Cribs and Trenches (BCCT) site at the Hanford site contains 20 disposal trenches and six disposal cribs. Wastes include a large inventory of technetium‐99 and large masses of nitrate and uranium‐238. ERT data were collected along 41 profiles in 2005 to characterize regions of elevated bulk electrical conductivity (BEC) associated with past liquid waste discharges. Previous analyses performed on samples from four boreholes showed a high correlation between nitrate concentration and BEC. In 2022, ERT data were re‐collected along the same profiles and six additional profiles in an area not previously surveyed. Compared to background uncontaminated areas, BEC was higher in contaminated areas at the waste sites. Given the correlation between nitrate concentration and BEC previously found at this site, ERT images show the spatial distribution and relative ionic concentration of vadose zone contaminants at BCCT. Between 2005 and 2022, ERT difference images showed a decrease in BEC surrounding most waste sites, with exceptions where there were known anthropogenic surface changes. An evaluation of recharge‐driven nitrate migration using synthetic flow and transport simulations showed that downward migration causes a decrease in BEC from the decrease in ionic strength at the trailing end of the plume where contaminants migrated downward. From this, we interpret ERT difference images as showing the predominant regions of downward ion flux.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Can Electrical Resistance Tomography be used for imaging unsaturated moisture flow in cement-based materials with discrete cracks?

Previously, it has been shown that Electrical Resistance Tomography (ERT) can be used for monitoring moisture flow in undamaged cement-based materials. In this work, we investigate whether ERT could be used for imaging three-dimensional (3D) unsaturated moisture flow in cement-based materials that contain discrete cracks. Novel computational methods based on the so-called absolute imaging framework are developed and used in ERT image reconstructions, aiming at a better tolerance of the reconstructed images with respect to the complexity of the conductivity distribution in cracked material. ERT is first tested using specimens with physically simulated cracks of known geometries, and corroborated with numerical simulations of unsaturated moisture flow. Next, specimens with loading-induced cracks are imaged; here, ERT reconstructions are evaluated qualitatively based on visual observations and known properties of unsaturated moisture flow. Results indicate that ERT is a viable method of visualizing 3D unsaturated moisture flow in cement-based materials with discrete cracks. - Highlights: • 3D EIT is developed to visualize water ingress in cracked mortar. • Mortar with different size discrete cracks are used. • The EIT results are corroborated with numerical simulations. • EIT results accurately show the temporal and spatial variation of water content. • EIT is shown to be a viable method to monitor flow in cracks and matrix.

36 MATERIALS SCIENCE↗

Uncertainty quantification of CO₂ saturation estimated from electrical resistance tomography data at the Cranfield site

A parametric bootstrap approach is presented for uncertainty quantification (UQ) of CO₂ saturation derived from electrical resistance tomography (ERT) data collected at the Cranfield, Mississippi (USA) carbon sequestration site. There are many sources of uncertainty in ERT-derived CO₂ saturation, but we focus on how the ERT observation errors propagate to the estimated CO₂ saturation in a nonlinear inversion process. Our UQ approach consists of three steps. We first estimated the observational errors from a large number of reciprocal ERT measurements. The second step was to invert the pre-injection baseline data and the resulting resistivity tomograph was used as the prior information for nonlinear inversion of time-lapse data. We assigned a 3% random noise to the baseline model. Finally, we used a parametric bootstrap method to obtain bootstrap CO₂ saturation samples by deterministically solving a nonlinear inverse problem many times with resampled data and resampled baseline models. Then the mean and standard deviation of CO₂ saturation were calculated from the bootstrap samples. We found that the maximum standard deviation of CO₂ saturation was around 6% with a corresponding maximum saturation of 30% for a data set collected 100 days after injection began. There was no apparent spatial correlation between the mean and standard deviation of CO₂ saturation but the standard deviation values increased with time as the saturation increased. The uncertainty in CO₂ saturation also depends on the ERT reciprocal error threshold used to identify and remove noisy data and inversion constraints such as temporal roughness. Five hundred realizations requiring 3.5 h on a single 12-core node were needed for the nonlinear Monte Carlo inversion to arrive at stationary variances while the Markov Chain Monte Carlo (MCMC) stochastic inverse approach may expend days for a global search. This indicates that UQ of 2D or 3D ERT inverse problems can be performed on a laptop or desktop PC.

58 GEOSCIENCES↗

An iterative particle filter approach for coupled hydro-geophysical inversion of a controlled infiltration experiment

The modeling of unsaturated groundwater flow is affected by a high degree of uncertainty related to both measurement and model errors. Geophysical methods such as Electrical Resistivity Tomography (ERT) can provide useful indirect information on the hydrological processes occurring in the vadose zone. In this paper, we propose and test an iterated particle filter method to solve the coupled hydrogeophysical inverse problem. We focus on an infiltration test monitored by time-lapse ERT and modeled using Richards equation. The goal is to identify hydrological model parameters from ERT electrical potential measurements. Traditional uncoupled inversion relies on the solution of two sequential inverse problems, the first one applied to the ERT measurements, the second one to Richards equation. This approach does not ensure an accurate quantitative description of the physical state, typically violating mass balance. To avoid one of these two inversions and incorporate in the process more physical simulation constraints, we cast the problem within the framework of a SIR (Sequential Importance Resampling) data assimilation approach that uses a Richards equation solver to model the hydrological dynamics and a forward ERT simulator combined with Archie's law to serve as measurement model. ERT observations are then used to update the state of the system as well as to estimate the model parameters and their posterior distribution. The limitations of the traditional sequential Bayesian approach are investigated and an innovative iterative approach is proposed to estimate the model parameters with high accuracy. The numerical properties of the developed algorithm are verified on both homogeneous and heterogeneous synthetic test cases based on a real-world field experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvement of electrical resistivity tomography for leachate injection monitoring

Leachate recirculation is a key process in the scope of operating municipal waste landfills as bioreactors, which aims to increase the moisture content to optimize the biodegradation in landfills. Given that liquid flows exhibit a complex behaviour in very heterogeneous porous media, in situ monitoring methods are required. Surface time-lapse electrical resistivity tomography (ERT) is usually proposed. Using numerical modelling with typical 2D and 3D injection plume patterns and 2D and 3D inversion codes, we show that wrong changes of resistivity can be calculated at depth if standard parameters are used for time-lapse ERT inversion. Major artefacts typically exhibit significant increases of resistivity (more than +30%) which can be misinterpreted as gas migration within the waste. In order to eliminate these artefacts, we tested an advanced time-lapse ERT procedure that includes (i) two advanced inversion tools and (ii) two alternative array geometries. The first advanced tool uses invariant regions in the model. The second advanced tool uses an inversion with a 'minimum length' constraint. The alternative arrays focus on (i) a pole-dipole array (2D case), and (ii) a star array (3D case). The results show that these two advanced inversion tools and the two alternative arrays remove almost completely the artefacts within +/-5% both for 2D and 3D situations. As a field application, time-lapse ERT is applied using the star array during a 3D leachate injection in a non-hazardous municipal waste landfill. To evaluate the robustness of the two advanced tools, a synthetic model including both true decrease and increase of resistivity is built. The advanced time-lapse ERT procedure eliminates unwanted artefacts, while keeping a satisfactory image of true resistivity variations. This study demonstrates that significant and robust improvements can be obtained for time-lapse ERT monitoring of leachate recirculation in waste landfills.

54 ENVIRONMENTAL SCIENCES↗

Applying Electrical Resistivity Tomography in Ornamental Stone Mining: Challenges and Solutions

In this study, the use of electrical resistivity tomography (ERT) as a tool to guide ornamental stone extraction is investigated. ERT is not conventionally used in highly resistive environments, such as on rock faces, due to the high contact resistances that can impede current injection. Here, the challenges of conducting ERT in such environments are discussed and possible solutions suggested. For this, an example of the application of ERT in a deep and narrow marble quarry is used. The marble deposit is affected by fracturing and karstification. Due to the nature of these features, they present a significant resistivity contrast to the background resistivity of the marble and thus excellent targets to test the application of ERT. Their location was mapped using field observations and complementary ground penetrating radar data. By using an appropriate sensor deployment, a suitable resistivity meter, and advanced data processing routines, the derived 3D resistivity model is in good agreement with the independent observations. This shows that despite the challenges, ERT can be used as a non-invasive tool to obtain information on the stone properties prior to extraction. This will help in guiding quarry operations and will allow for a targeted, safe and efficient extraction of high quality stone, thereby increasing sustainability and economical competitiveness.

58 GEOSCIENCES↗

Electrical resistance tomography to monitor unsaturated moisture flow in cementitious materials

Traditionally the electrically-based assessment of the moisture flow in cement-based materials relies on two- or four-point measurements. In this paper, imaging of moisture distribution with electrical resistance tomography (ERT) is considered. Especially, the aim is to study whether ERT could give information on unsaturated moisture flows in cases where the flow is non-uniform. In the experiment, the specimens are monitored with ERT during the water ingress. The ERT reconstructions are compared with neutron radiographs, which provide high resolution information on the 2D distribution of the moisture. The results indicate that ERT is able to detect the moisture movement and to show approximately the shape and position of the water front even if the flow is nonuniform.

36 MATERIALS SCIENCE↗

A Retrospective, Multicenter Study of the Tolerance of Induction Chemotherapy With Docetaxel, Cisplatin, and 5-Fluorouracil Followed by Radiotherapy With Concomitant Cetuximab in 46 Cases of Squamous Cell Carcinoma of the Head and Neck

Purpose: To investigate, in a multicenter study, the tolerance of induction chemotherapy (ICT) and external radiotherapy (ERT) with concomitant cetuximab in the treatment of patients with squamous cell carcinoma of the head and neck (SCCHN). Patients and Methods: Clinical data from 46 patients with Stage III or IV nonmetastatic SCCHN who received docetaxel, cisplatin, and 5-fluorouracil as ICT, followed by ERT with concomitant cetuximab, were retrospectively analyzed. Clinical safety (weight, allergy, mucositis, and dermatitis) and paraclinical safety (levels of hemoglobin, polynuclear neutrophils, and creatinine clearance) were studied. The primary objective was the proportion of patients who completed the protocol. Results: The percentage of patients completing ICT was 73.9%, ERT 93.5%, and cetuximab 69.6%. Induction chemotherapy was better tolerated than that previously reported. The rates of temporary suspensions of radiation (39.1%, mean duration of 13 days) and hospitalization (26.1%) during ERT with concomitant cetuximab were high. Weight loss during treatment (21.4% of patients lost >10% of their body weight), radiodermatitis, and radiomucositis were the main causes of temporary suspension of treatment, although Grade 4 dermatitis was not experienced. There were no allergic reactions to cetuximab. Conclusion: The completed protocol rate for SCCHN patients receiving ICT and ERT with concomitant cetuximab is high and the toxicity acceptable. Future improvements to protocol will be possible through early action and systematic implementation of nutritional support coupled with antibiotic treatment upon the first signs of radiodermatitis. These data could be useful for prospective studies on the safety and efficacy of this protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed study of the eikonal reaction theory for the breakup of one-neutron halo nuclei

Background: One-neutron removal reactions are used to study the single-particle structure of unstable nuclei, and in particular the exotic halo nuclei. The eikonal reaction theory (ERT) has been developed by Yahiro, Ogata, and Minomo [Prog. Theor. Phys. 126, 167 (2011)] to include dynamical effects, which are missing in the usual eikonal description of these reactions. Encouraging results have been obtained for total breakup cross sections in comparison to more elaborate reaction models. Purpose: Here, we extend these comparisons to more differential breakup cross sections expressed as functions of the relative energy or parallel momentum between the core and halo neutron. Method: ERT predictions of these cross sections are compared to state-of-the-art calculations. Results: The hypotheses upon which the ERT is based are confirmed and their range of validity is made clearer. The actual ordering of the evolution operators affects ERT differential cross sections and a specific choice leads to excellent agreement with the reference calculation. Dynamical effects in the treatment of the neutron-target interaction can be significant in the parallel-momentum observable. Conclusions: The role of the different interactions in the dynamics of breakup reactions of one-neutron halo nuclei are better understood and improvements to the ERT are suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation

Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surfacebased ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.

amendment↗

An Ultra-Precise System for Electrical Resistivity Tomography Measurements

The objective of this research was to determine the feasibility of building and operating an ERT system that will allow measurement precision that is an order of magnitude better than existing systems on the market today and in particular if this can be done without significantly greater manufacturing or operating costs than existing commercial systems. Under this proposal, we performed an estimation of measurement errors in galvanic resistivity data that arise as a consequence of the type of electrode material used to make the measurements. In our laboratory, measurement errors for both magnitude and induced polarization (IP) were estimated using the reciprocity of data from an array of electrodes as might be used for electrical resistance tomography using 14 different metals as well as one non-metal - carbon. In a second phase of this study, using archival data from two long-term ERT surveys, we examined long-term survivability of electrodes over periods of several years. The survey sites were: the Drift Scale Test at Yucca Mountain, Nevada (which was sponsored by the U. S. Department of Energy as part of the civilian radioactive waste management program), and a water infiltration test at a site adjacent to the New Mexico Institute of Mines and Technology in Socorro, New Mexico (sponsored by the Sandia/Tech vadose program). This enabled us to compare recent values with historical values and determine electrode performance over the long-term as well as the percentage of electrodes that have failed entirely. We have constructed a prototype receiver system, made modifications and revised the receiver design. The revised prototype uses a new 24 bit analog to digital converter from Linear Technologies with amplifier chips from Texas Instruments. The input impedance of the system will be increased from 107 Ohms to approximately 1010 Ohms. The input noise level of the system has been decreased to approximately 10 Nanovolts and system resolution to about 1 Nanovolt at the highest gain range of 125 to 1. The receiver also uses very high precision and high temperature stability components. The goal is to improve the accuracy to better than 0.1%. The system has more receiver channels, eight, to allow efficient data collection at lower base frequencies. We are also implementing a frequency-domain acquisition mode in addition to the time-domain acquisition mode used in the earlier systems. Initial field tests were started in the fall of 2008. We conducted tests on a number of types of cable commonly used for resistivity surveys. A series of different tests were designed to determine if the couplings were primarily resistive, capacitive, or inductive in nature and to ascertain that the response was due to the cable cross-talk and did not depend on the receiver electronics. The results show that the problem appears to be primarily capacitive in nature and does not appear to be due to problems in the receiver electronics. Thus a great deal of emphasis has been placed on finding appropriate cables as well as stable electrodes that have low contact impedance at the very low current flows observed at the receiver. One of the issues in survey design and data collection has been determining how long one must wait before using the same electrode as a transmitter and as a receiver. A series of tests was completed in the laboratory sand tank where four-electrode measurements were made using the same dipole transmitters and dipole receivers (the dipoles used adjacent electrodes). For each data series, a single set of normal measurements were collected with no reciprocals and electrodes were never reused as a receiver after being used as a transmitter. After waiting a specified length of time, the reciprocal measurements were collected using a schedule of measurements. The order of this second schedule was rearranged such that if this second set of measurements were performed without first using the normal schedule, no electrode would be used as a receiver after being used as a transmitter. For this study, we cannot conclude that increasing the wait time increased or decreased the reciprocal errors, only that there was not a dramatic change in results with different wait times. Another issue in ERT data collection is the potential for the transmitter as well as the receiver end of an ERT system to create problems with reciprocity readings. Existing ERT systems typically use a constant voltage source. For the transmitter dipole, a constant voltage source has low output impedance, whereas a constant current source has high output impedance. Therefore, we devised an experiment to determine if a constant current source transmitter might produce smaller errors than a constant voltage source. These preliminary results suggest there is little or no difference in either resistivity or chargeability reciprocal errors using a constant voltage or constant current dipole drive source.

47 OTHER INSTRUMENTATION↗

PILOT-SCALE FIELD VALIDATION OF THE LONG ELECTRODE ELECTRICAL RESISTIVITY TOMOGRAPHY METHOD

Field validation for the long electrode electrical resistivity tomography (LE-ERT) method was attempted in order to demonstrate the performance of the technique in imaging a simple buried target. The experiment was an approximately 1/17 scale mock-up of a region encompassing a buried nuclear waste tank on the Hanford site. The target of focus was constructed by manually forming a simulated plume within the vadose zone using a tank waste simulant. The LE-ERT results were compared to ERT using conventional point electrodes on the surface and buried within the survey domain. Using a pole-pole array, both point and long electrode imaging techniques identified the lateral extents of the pre-formed plume with reasonable fidelity, but the LE-ERT was handicapped in reconstructing the vertical boundaries. The pole-dipole and dipole-dipole arrays were also tested with the LE-ERT method and were shown to have the least favorable target properties, including the position of the reconstructed plume relative to the known plume and the intensity of false positive targets. The poor performance of the pole-dipole and dipole-dipole arrays was attributed to an inexhaustive and non-optimal coverage of data at key electrodes, as well as an increased noise for electrode combinations with high geometric factors. However, when comparing the model resolution matrix among the different acquisition strategies, the pole-dipole and dipole-dipole arrays using long electrodes were shown to have significantly higher average and maximum values than any pole-pole array. The model resolution describes how well the inversion model resolves the subsurface. Given the model resolution performance of the pole-dipole and dipole-dipole arrays, it may be worth investing in tools to understand the optimum subset of randomly distributed electrode pairs to produce maximum performance from the inversion model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Near Real-Time Two and Three-Dimensional Electrical Geophysical Monitoring of Natural and Engineered Processes Associated with Subsurface Remediation - 16052

Legacy soil and groundwater contamination associated with nuclear weapons production is projected to be one of the largest cleanup liabilities to the U.S. Department of Energy for the foreseeable future. Remediation of subsurface contaminants is complicated by the combined effects of geochemical heterogeneity, geological heterogeneity, and the difficulty and expense of adequate borehole access. Each of these complications contributes to uncertainty in the distribution of contaminants and the performance of in situ treatments, which increases risk to human health and the environment and cost to closure in general. Electrical resistivity tomography (ERT) is a method of remotely imaging the electrical properties of the subsurface, which are governed by both geochemical and geological structure, thereby providing useful proxies for understanding contaminant distribution and the behavior in situ remediation processes. Recent advancements in both data collection and data processing capabilities are enabling ERT monitoring to be executed and provided to site operators in near real-time. To summarize the process, ERT surveys are rapidly and continuously collected during a time-sensitive operation such as an amendment injection. At the completion of each survey, data are transferred by wireless internet to offsite supercomputing resources for parallel tomographic inversion. Inversion results are then transferred back to onsite operators and/or other locations for visualization. In this paper, we demonstrate the utility of time-lapse ERT for monitoring fluid transport (both gas and liquid phase). We then demonstrate two real-time imaging applications for monitoring both natural and engineered processes at the Hanford Site within the vadose and the saturated zones. We expect this new capability for autonomous real-time imaging to enable ERT to be used as a cost-effective, short-term rapid feedback mechanism for guiding subsurface remediation injections, in addition to longer term monitoring of post-injection performance and environmental impact, all using the same electrode array and instrumentation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-lapse 3-D electrical resistance tomography inversion for crosswell monitoring of dissolved and supercritical CO 2 flow at two field sites: Escatawpa and Cranfield, Mississippi, USA

In this study, we advance the understanding of three-dimensional (3-D) electrical resistivity tomography (ERT) for monitoring long-term CO 2 storage by analyzing two previously published field time-lapse data sets. We address two important aspects of ERT inversion-the issue of resolution decay, a general impediment to the ERT method, and the issue of potentially misleading imaging artifacts due to 2-D model assumptions. The first study analyzes data from a shallow dissolved-CO 2 injection experiment near Escatawpa (Mississippi), where ERT data were collected in a 3-D crosswell configuration. Here, we apply a focusing approach designed for crosswell configurations to counteract resolution loss in the inter-wellbore area, with synthetic studies demonstrating its effectiveness. The 3-D field data analysis reveals an initially southwards-trending flow path development and a dispersing plume development in the downgradient inter-well region. The second data set was collected during a deep (over 3 km) injection of supercritical CO 2 near Cranfield (Mississippi). Comparative 2-D and 3-D inversions reveal the projection of off-planar anomalies onto the cross-section, a typical artifact introduced by 2-D model assumptions. Conforming 3-D images from two different algorithms support earlier hydrological investigations, indicating a conduit system where flow velocity variations lead to a circumvention of a close observation well and an onset of increased CO 2 saturation downgradient from this well. We relate lateral permeability variations indicated by an independently obtained hydrological analysis to this consistently observed pattern in the CO 2 spatial plume evolution.

3-D inversion↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

3D Time-Lapse Electrical Resistivity Imaging of Rock Damage Patterns and Gas Flow Paths Resulting from Two Underground Chemical Explosions

Abstract Rock damage from underground nuclear explosions (UNEs) has a strong influence on sub-surface gas movement and on seismic waveform characteristics, both of which are used to detect UNEs. Although advanced numerical simulation capabilities exist to predict rock damage patterns and corresponding detection signals, those predictions are dependent on (generally) unknown properties of the host rock. For example, the effects of in-situ mechanical heterogeneities on the explosively generated damage/fractures that provide gas flow pathways to the surface are not well understood, due largely to the difficulty in accessing and characterizing the near-source region. In this paper we demonstrate the emerging use of electrical resistivity tomography (ERT) for imaging rock damage and gas flow patterns resulting from two relatively small-scale underground chemical explosions. Pre-explosion ERT and crosshole seismic imaging revealed a natural fracture zone within the test bed. Post-explosion imaging revealed that the damage zone was non-symmetric and was focused primarily within the pre-existing fracture zone, located 10 m above the first explosion and 5 m above the second explosion. Time-lapse ERT imaging of heated air injected into the detonation borehole revealed the primary gas flow paths to be within the upper margin of the same primary damage zone. These results point to the utility of ERT imaging for understanding rock damage and gas flow patterns under experimental conditions, and to the importance of understanding the effects of geologic heterogeneity on UNE detection signals, particularly gas surface breakthrough times.

58 GEOSCIENCES↗