The 0.5 Mev gamma ray flux and the energy loss spectrum in CsI/t1/ at 4 g/cm super 2.
Energy loss spectrum in CsI at small atmospheric depths, discussing time variation of 0.5-mev gamma-ray flux
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Energy loss spectrum in CsI at small atmospheric depths, discussing time variation of 0.5-mev gamma-ray flux
Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.
The use of the Born approximation in describing the energy loss process for relativistic cosmic rays with Z above 20 underestimates the energy loss due to the production of high-energy secondary electrons. The implications of this fact for the response of various detectors, such as ion chambers, scintillators, emulsions, and Cerenkov counters are discussed.
Direct observation of cosmic ray kinetic energy losses in interplanetary region by measurements at separated spacecraft
The ionization energy loss of relativistic heavy nuclei is calculated using the exact Mott cross section for close collisions. Deviations from the Bloch formula are computed in some typical cases and found to be significant for nuclei with Z greater than 20.
High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.
The energy loss of relativistic electrons is considered for astrophysical objects which contain energetic photon gases in the XUV-range. Such objects have been suggested as possible candidates for gamma-ray point sources through the mechanism of inverse Compton scattering. In certain cases where inverse Compton scattering is the dominant energy loss mechanism, an equilibrium spectrum results which can deviate from a strict power law. Such an effect can have consequences on the observed radiation spectrum from such objects.
Energy loss of charged particles in plasmas
Differential approximation for radiant energy loss in nonequilibrium plasma generated from truncated Taylor series expansion of radiation source function
Energy loss of cosmic rays in interplanetary medium
The different kinds of energy losses of the propeller and the values of the constants determining them are discussed.
Oscillograph measurements of energy losses in closing electric contacts - electrode erosion
This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.
Thick lithium drifted semiconductor silicon detectors for investigation of fluctuations of energy loss by high and intermediate energy particles
Electron temperature vs plasma cell power input measured, determining electron energy loss factor for hot diatomic gases in electric field
A framework for simulating the real-time dynamics of composite particles in a simple model of dense matter that is amenable to quantum computers is developed. As a demonstration, we perform classical simulations of heavy-hadrons propagating through a dense medium in the Schwinger model. Measurements of the time-dependent energy and charge density are used to identify mechanisms responsible for energy loss and hadron production (hadronization). A study of entanglement dynamics highlights the importance of quantum coherence between the particles that make up the dense medium. Throughout this work, care is taken to isolate, and remove, phenomena that arise solely from a finite lattice spacing. It is found that signatures of entanglement are more sensitive to lattice artifacts than other observables. Toward quantum simulations, we present an efficient method and the corresponding quantum circuits for preparing ground states in the presence of heavy mesons. Finally, these circuits are used to estimate the resources required to simulate in-medium energy loss and hadronization in the Schwinger model using quantum computers.
Cosmic ray energy loss in interplanetary medium, discussing solar wind effects on low energy particles
Explore the source record for details and available documents.