Historically, time-of-flight (TOF) nuclear cross section measurements on different nuclides are assumed to be uncorrelated if they were recorded in different facilities with identical methods, identical facilities with different methods, and even identical facilities with identical methods. Ideally, measurements of different nuclides would truly be uncorrelated thus providing independent assessments of some cross section. In reality, correlations exist between measurements but are simply assumed to be unimportant. To eliminate these qualitative assumptions, in this paper we make a counter-intuitive suggestion to perform an intentionally correlated measurement of energy-differential fission and capture reactions for nuclides in a single criticality safety benchmark during a single experimental campaign. While this would introduce undesirable correlations, it would fully quantify correlations between datasets, rather than assume that the correlations do not exist.