Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENDF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

GNDS Expert Group Report [Slides]

The presentation discusses the GNDS-1.9 specifications that were published during the Summer 2020 and a webinar that occurred on 8 July 2020. It also discusses the goals of the GNDS-2.0, including the intention to satisfy the remaining SG-38 goals, to ensure “forwards compatibility” with ENDF-6, and to respond to user needs. It discusses the 2020 status and a poll that was implemented to find out more about how GNDS is being implemented. The presentation states that some projects are far along in their GNDS support and that most are open source with 20% closed source. It also states that GNDS's purpose is to inspire younger scientists with a histogram displaying what fraction of the developers are student, post-docs, and junior staff. The presentation concludes by discussing what is next including major format changes post-GNDS-2.0 and an ENDF to GNDS transition.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of FUDGE [Slides]

This presentation discusses the nuclear data management code FUDGE (For Updating Data and Generating Evaluations). While FUDGE is designed to support GNDS, the presentation also states that ENDF-6 and ENDL data files are also supported but must first be translated into GNDS; translators are included with FUDGE. It also states that FUDGE supports plotting, manipulating, checking for physical content, resonance reconstruction, Doppler broadening, etc. FUDGE also supports processing for Monte Carlo and deterministic transport. FUDGE is open source, and the latest public release was FUDGE-4.2.3 with support for GNDS-1.9. In summation, FUDGE capabilities include translating older formats into GNDS, translating GNDS back to ENDF-6, and visualizing, modifying, checking, and processing GNDS data. It also states that a new version of FUDGE is coming soon. The plan is to support GNDS-2.0 specification, but it may be released sooner if v2.0 is delayed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.1 Validation: Covariance [Slides]

This presentation touches on ENDF/B-VIII.1 Validation: Covariance. Topics include inconsistencies in the ENDF files, derived matrices, lumped reactions and process ENDF data file with PUFF. Finally correcting data with cognac and redundant covariance that are not consistent are discussed.

Cognac↗

ENDF/B-VIII.0 Testing With AMPX and SCALE

As the new ENDF/B-VIII.0 data has continued development from its initial beta release into the final release version, it has subsequently undergone processing and testing at Oak Ridge National Laboratory with AMPX and SCALE. Each of the beta releases has been processed with AMPX to create both multigroup (MG) and continuous-energy (CE) libraries. The MG libraries were all processed using the SCALE 252-group structure. These libraries were then used with the VALID suite for benchmarking the new data library’s performance against the currently distributed ENDF/B-VII.1 (VII.1)-based SCALE libraries. Here, we compare the MG and CE VALID results for the two current ENDF releases, versions VII.1 and the most recent beta release of ENDF/B-VIII.0 as of this writing (VIII.0.β4). Generally, both the MG and CE VALID aggregate results for VIII.0.β4 compare reasonably well with their VII.1-derived counterparts. As can be expected of any new ENDF release, some of the individual cases have substantially different computed neutron multiplicity (k eff ) values between the two releases, although typically the differences are less than 100 percent-milli (pcm). However, changes to the plutonium cross sections have induced much larger changes in the ratio of the computed k eff to the experimental value (C/E) for thermal spectrum plutonium solution critical systems. This paper details the comparative performance of the VII.1 and VIII.0.β4 data for the broad range of test cases covered by the VALID suite. A companion paper at this conference provides details of the baseline validation of SCALE 6.2, including the first release of the VII.1 data.

97 MATHEMATICS AND COMPUTING↗

ENDF/B-VIII.0 Augmented Covariance Data: The first iteration

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advancements in Validation of TSLs through Inelastic Neutron Scattering and Transmission Measurements [Abstract]

Historically, the free gas approximation has been used to treat the thermal scattering of neutrons with energies below a few electron-volts (eV) in unevaluated materials. However, this method inadequately reproduces neutron scattering at these energies. Until recently, only a limited number of materials had available thermal scattering law (TSL) files/libraries in the ENDF nuclear data libraries in this energy range. With advancements in atomistic modeling techniques, such as molecular dynamics, ab-initio molecular dynamics, and density functional theory, TSL libraries have become available for many more materials. This is particularly relevant due to the rising interest in several advanced reactor systems that require novel moderator and reflector materials. While quasi-integral and integral benchmarks have been designed to validate historically important moderator materials (such as light water and polyethylene), there is currently a lack of standard validation methods for TSLs, especially when multiple conflicting TSLs exist. To address this issue, the Oak Ridge National Lab Nuclear Data group has been working on utilizing inelastic neutron scattering (INS) measurements combined with transmission (i.e., total cross section) measurements to evaluate and validate TSLs for different materials. We plan to demonstrate how this method has worked on materials such as polyethylene, lucite, and polystyrene. In addition, we will compare the newly created libraries to ENDF libraries for these materials and explain why integral benchmarks should not be used for validation when multiple TSLs exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear data uncertainty and sensitivity analysis of the VHTRC benchmark using SCALE

The Very High Temperature Critical Assembly (VHTRC) experiment represents one of the few data sets available for the validation of HTGR lattice physics. Within the framework of the IAEA Coordinated Research Project on HTGR Uncertainty Analysis in Modeling, uncertainty and sensitivity analyses of this graphite-moderated facility are performed as the validation reference to the prismatic MHTGR-350 fuel block calculations. Nominal multi-group and continuous-energy criticality calculations with the KENO-VI Monte Carlo code of the SCALE code package are compared with the continuous-energy Monte Carlo Code Serpent. Good agreement with a maximum difference of 250 pcm is obtained. The experimental data set, however, differs by several hundred pcm with the results of both codes when using the ENDF-VII.0 library. When using ENDF/B-VII.1 data, this difference is reduced to a few hundred pcm and the calculations lie within the experimental error bars. Uncertainties of the VHTRC multiplication factors due to uncertainties in nuclear data are determined with SAMPLER/KENO-VI of SCALE 6.2 and with continuous-energy TSUNAMI of SCALE 6.2. For all experimental configurations, the obtained uncertainty is found to be 0.58% when using ENDF/B-VII.0 data. The top contributor to this uncertainty is the average number of neutrons per fission event of U-235. With ENDF/B-VII.1 data, uncertainties of about 0.66% are obtained in particular due to an increased uncertainty of U-235 nu-bar in the latest ENDF release. In conclusion, when considering these nuclear data uncertainties, the obtained 1s uncertainty intervals are overlapping with the experimental error bars.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uranium integral fission product yields for a spectrally-shaped 14.1 MeV neutron source at the National Ignition Facility

This paper describes the experimental results for an energy tuning assembly created to modify the National Ignition Facility deuterium–tritium fusion neutron source into a notional thermonuclear and prompt fission neutron spectrum, which has applications in integral measurements, nuclear data benchmarks, and radiation effects on microelectronics. The Monte Carlo neutron transport utilized MCNP5 to estimate the ETA-modified fluence using the ENDF-B/VIII.0 and IRDFF-II continuous energy nuclear data libraries, and SCALE Sampler was used to estimate the systematic nuclear data covariance using ENDF-B/VII.1 and IRDFF-II in a 252-group structure. The experiment fielded eight activation foils and a highly enriched uranium sample. This provided fifteen reaction channels that were used in a forward-fit comparison to the modeled results and to unfold the neutron spectrum using STAYSL. Gamma-ray spectrometry was performed on the activation and highly enriched uranium foils, and the reduced Χ 2 between the modeled and experimental values was 1.21. The results from the STAYSL unfold, reduced Χ 2 = 1.62, indicated that the modeled neutron spectrum was achieved and the systematic nuclear data uncertainty associated with the neutron transport and activation product cross sections was representative of the experiment. Integral cumulative fission product yield data were collected for 37 mass chains with a combination of gamma-ray spectrometry and radiochemical analysis. Fission product analysis was generally in agreement with two models using a semi-empirical fit and the General Observables of Fission code, with the exception of mass chains 88, 109, 111, 112, 113, 129, 139, 142, 144, 151, and 156.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Calculations of Astrophysical Reaction Rates Using ENDF/B-VIII.0 Library

Recent observations of neutron stars merger (GW170817) renewed interest in stellar nucleosynthesis. Stellar nucleosynthesis modeling requires fully traceable, unbiased, high fidelity nuclear data. The Evaluated Nuclear Data File (ENDF) libraries contain complete collections of reaction data sets over the nuclear industry standard 10 -5 eV - 20 MeV energy span. For the first time, the (n,γ), (n,fission), (n,p), and (n,α) astrophysical reaction rates were computed within the 0.01-10 GK range of temperatures using the ENDF/B-VIII.0 library, and nuclear Reaction rate Library for astrophysics (REACLIB) fit parameters were deduced. The present results were used to estimate the slow neutron capture timescale. These findings demonstrate the potential astrophysical applications of the ENDF libraries and the complementary relations between the nuclear industry and astrophysics data developments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of MCNP thermal scattering laws to inelastic neutron scattering data

Neutron transport computations employ thermal scattering laws (TSLs) to account for the influence of material structure and collective excitations at low energy (≲ 10 eV). Recent work has been undertaken to improve TSL accuracy and expand the number of available materials in the Evaluated Nuclear Data File (ENDF). However, comparison of TSL to measured data is often sparse. In this work, we present a method to evaluate TSL accuracy in the Monte Carlo N-Particle (MCNP) code by simulating inelastic neutron scattering (INS) measurement and comparing to data. The method is briefly described with example application to the recently released ENDF-VIII TSL library for polyethylene as well as a cryogenic PE TSL we are separately developing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking fast-neutron response of 7 Li-enriched C 7 LYC scintillators: Simulations and experiment

New insights into the fast neutron response of 7 Li-enriched C 7 LYC scintillators have been obtained through detailed Geant4 simulations of 35 Cl(n,p) and 35 Cl(n, α) reactions that are primarily responsible for the fast neutron response of C 7 LYC. The light output of a 1” x1” C 7 LYC detector was simulated using the Birks equation for light quenching in scintillators. The simulations were benchmarked against neutron scattering data from a 12 C target obtained with a white neutron beam at the Los Alamos LANSCE facility and fourteen 1”x1” C 7 LYC detectors. Incident neutron energies extracted from time-of-flight measurements, and appropriate recoil corrections for the different detector angles were used to map the response of C 7 LYC to mono-energetic neutrons. Resonances in the 35 Cl(n,p) reaction cross-section below 3 MeV incident neutron energy were directly observed in C 7 LYC. The experimental data and simulations are compared with ENDF databases, as well as recent direct cross-section measurements of neutrons scattered from a 35 Cl target. In conclusion, the results suggest a scrutiny of the 35 Cl(n,p) and 35 Cl(n, α) cross sections at low energy in the ENDF library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Monte Carlo Evaluation of Imperfect (n, 233 U) Data and Model

Conventional nuclear data evaluation methods using generalized linear least squares make the following assumptions: prior and posterior probability distribution functions (PDFs) of all model parameters and data are normal (Gaussian); the linear approximation is sufficiently accurate to minimize the cost function (even for nonlinear models); the model (e.g., of neutron cross section) and experimental data (including covariance data) are without defect and prior PDFs of parameters and measured data are known perfectly. Neglect of covariance between model parameters and measured data in conventional evaluations contributes to imperfections. These assumptions are inherent to the generalized linear least squares minimization method commonly used for resolved resonance region neutron cross section evaluations but are often not justified due to the presence of non-normal PDFs, nonlinear models (e.g., R-matrix formalism), and inherent imperfections in data and models (e.g., imperfect covariance data). Here, these assumptions are removed in a mathematical framework of Bayes’ theorem, which is implemented using the Metropolis-Hastings Monte Carlo method. Most importantly, new parameters are introduced to parameterize discrepancies between the theoretical model and measured data to quantify judgement about discrepancies or imperfections in a reproducible manner. An evaluation of 233U in the eV region using the ENDF-B/VIII.0 library and transmission data (Guber et al.) is presented, and posterior parameters are compared to those obtained by conventional evaluation methods. This example illustrates the effects of removing the most harmful assumption: that of model-data perfection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A tale of two tools: mcres.py, a stochastic resonance generator, and grokres.py, a resonance quality assurance tool

We detail two software tools, now integrated into the fudge code system. The first tool, mcres.py, can be used to generate stochastic ensembles of resonances which are both consistent with the expectations of the Gaussian Orthogonal Ensemble of Random Matrix Theory and with the level densities and widths encoded in ENDF formatted files. The second tool, grokres.py, can be used to assess global and local features of sequences of resonances found in ENDF files and make comparisons to known results from Random Matrix Theory. We apply these tools to 54 Fe and other nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WPEC Subgroup-38 Final Report part II: Specifications for a new database structure

This is the revision of the specifications for the Generalised Nuclear Database Structure (GNDS), corresponding to GNDS version 1.9. GNDS is designed to serve as a replacement for the Evaluated Nuclear Data Format (ENDF). Although GNDS supersedes the ENDF6 format, GNDS should be viewed as a natural evolution of the ENDF-6 format, using modern computational tools to make nuclear data more accessible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of the Baseline USL Calculation Methods for Loosely-Coupled and Novel Neutronic Systems [Slides]

Current work includes reconstructing 187-group ENDF B/VII.1 covariance matrix for comparison study to 44-group ENDF B/VII.1 matrix to determine how covariance matrix structures affect the USL calculations and investigating the exact domination mechanism of region-wise sensitivities in a loosely-coupled system. Future work will involve seeking to understand how bias distributions change with reactivity and how to calculate propagate distribution error into USL calculations, as well as how cross section perturbation studies can be extended to other types of calculations, such as shielding calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release of ENDF/B-VIII.1β1-Based ACE Data Files

On March 1 st , 2023, the National Nuclear Data Center (NNDC) released the ENDF/B-VIII.1β1 nuclear data library, which contained neutron, spontaneous and neutron-induced fission yield, and alpha sublibraries. The library was released in the standard Evaluated Nuclear Data File (ENDF) format. The files can be accessed on Brookhaven National Laboratory’s GitLab. The thermal scattering law (TSL) sublibrary will be released at a later date. The files provided in the neutron sublibrary were processed into A Compact ENDF (ACE)-formatted files, verified, and validated by the XCP-5 Nuclear Data Team. The resulting collection of ACE files will be referred to as the “e81b1” library. This report details the processing of these files and the quality assurance approach taken. This is not intended to be a full validation effort; rather, this library is intended to simply reproduce the released files for further validation testing by the community. The e81b1 ACE library will be released to the NNDC for access through GitLab and hosted locally on LANL computing resources. This library is only intended for analysis to support the future ENDF/B-VIII.1 release and should not be used for production results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗