At least 55 records · Page 3

Irradiation of nuclear track emulsions with thermal neutrons, heavy ions, and muons

Exposures of test samples of nuclear track emulsion were analyzed. Angular and energy correlations of products originating from the thermal-neutron-induced reaction n{sub th} +{sup 10} B → {sup 7} Li + (γ)+ α were studied in nuclear track emulsions enriched in boron. Nuclear track emulsions were also irradiated with {sup 86}Kr{sup +17} and {sup 124}Xe{sup +26} ions of energy about 1.2 MeV per nucleon. Measurements of ranges of heavy ions in nuclear track emulsionsmade it possible to determine their energies on the basis of the SRIM model. The formation of high-multiplicity nuclear stars was observed upon irradiating nuclear track emulsions with ultrarelativistic muons. Kinematical features studied in this exposure of nuclear track emulsions for events of the muon-induced splitting of carbon nuclei to three alpha particles are indicative of the nucleardiffraction interaction mechanism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Silica and Mixing Time on Microstructures of Porous Polymer Composite by Emulsion Templating

Porous polymer composite with tailored porosity is applied in the myriads of areas such as energy storage, oil/water absorption, bioengineering, and advanced areas of material science. The emulsion templating technology is one of the most popular methods for synthesizing porous polymer composite. It involves solidifying a two-phase mixture of porogen and polymer, then removing porogen to create pores within the continuous emulsion phase by polymerization or curing. The surfactant plays a pivotal role in accomplishing a stable emulsion, a key factor in designing the internal porous structure. This study highlights the effect of silica filler and mixing time on pore morphology, i.e., shape, size, and distribution. on polydimethylsiloxane (PDMS) porous structure utilizing the water-in-oil emulsion templating method. Span® 80 is used as a surfactant to reduce the surface tension between water, silica, and PDMS and simultaneously create a strong foaming effect. Different weight concentrations of silica (1-10 wt%) were chosen while keeping the internal phase, i.e., water (50 wt%) constant. The designed porous structures were further characterized through scanning electron microscopy (SEM). Porous composite specimens fabricated with higher silica content and mixing time consistently exhibit smaller pore sizes than specimens fabricated with lower mixing time and silica content. A breakthrough of pore morphology is seen at silica content higher than 5wt% at 1 min mixing, however, pore morphology drastically changes when mixing time increases from 1 min to 6 min. Variation of finer mixing time beyond 1 min shows stepwise changes in pore morphology from a large single-phase porous structure to a bi-modal porous structure which eventually become a smaller single-mode porous structure. Thus, the emulsion templating technique, in combination with different filler content and mixing time, will effectively aid in designing engineered porous polymer composite with varying stiffness and pore morphology.

Porous polymer, Emulsion templating, Surfactant, P↗

Transport and Retention of Concentrated Oil-in-Water Emulsions in Porous Media

Oil-in-water emulsions are routinely used in subsurface remediation. In these applications, high oil loadings present a challenge to remedial design as mechanistic insights into transport and retention of concentrated emulsions is limited. In this paper, column experiments were designed to examine emulsion transport and retention over a range of input concentrations (1.3–23% wt). Droplet breakthrough and retention data from low concentration experiments were successfully described by existing particle transport models. These models, however, failed to capture droplet transport in more concentrated systems. At high oil fraction, breakthrough curves exhibited an early fall at the end of the emulsion pulse and extending tailing. Irrespective of input concentration, all retention profiles displayed hyper-exponential behavior. Here, we extended existing model formulations to include the additional mixing processes occurring when at high oil concentrations—with focus on the influence of deposited mass and viscous instabilities. The resulting model was parametrized with low concentration data and can successfully predict concentrated emulsion transport and retention. Finally, the role of retained mass and viscous instabilities on mixing conditions can also be applied more broadly to systems with temporal or spatially variant water saturation or when viscosity contrasts exist between fluids.

54 ENVIRONMENTAL SCIENCES↗

Parallelizable microfluidic dropmakers with multilayer geometry for the generation of double emulsions

Microfluidic devices enable the production of uniform double emulsions with control over droplet size and shell thickness. However, the limited production rate of microfluidic devices precludes the use of monodisperse double emulsions for industrial-scale applications, which require large quantities of droplets. To increase throughput, devices can be parallelized to contain many dropmakers operating simultaneously in one chip, but this is challenging to do for double emulsion dropmakers. Production of double emulsions requires dropmakers to have both hydrophobic and hydrophilic channels, requiring spatially precise patterning of channel surface wettability. Precise wettability patterning is difficult for devices containing multiple dropmakers, posing a significant challenge for parallelization. In this paper, we present a multilayer dropmaker geometry that greatly simplifies the process of producing microfluidic devices with excellent spatial control over channel wettability. Wettability patterning is achieved through the independent functionalization of channels in each layer prior to device assembly, rendering the dropmaker with a precise step between hydrophobic and hydrophilic channels. We report this device geometry enables uniform wettability patterning of parallelized dropmakers, providing a scalable approach for the production of double emulsions.

36 MATERIALS SCIENCE↗

Performance of Different “Lab-On-Chip” Geometries for Making Double Emulsions to Form Polystyrene Shells

Fluid properties and the geometry of lab-on-chip (LOC) designs together affect the formation of double emulsions for making inertial confinement fusion targets. Critical fluid properties include the fluids’ velocities and interfacial tension—a coupled effect that is best characterized by the capillary number (Ca)—and the relative volumetric flow rates (φ). The important geometry of the LOC is the orientation of the channels where they intersect (junction) and the spacing between successive junctions. T-junctions and focus-flow devices were tested. The latter geometry of a double cross (focus flow) performed better: single-emulsion droplets were formed over a wide range of fluid parameters (0.03 < φ < 0.17 and 0.0003 < Ca < 0.001) at the first junction, and double emulsions were formed over a more limited range (φ > 0.5 and Ca < 0.4) at the second junction. A LOC design using the focus-flow design formed water–oil–water (W/O/W) double emulsions with the oil phase containing polystyrene. The double emulsions yielded shells with an outer dimension ranging from 2.3±0.07 mm to 4.3±0.23 mm and a wall thickness ranging from 30 μm to 1.6 mm. Thus, the value of the flow-rate ratio at the second junction provided the most-effective parameter for controlling the inner diameter, outer diameter, and wall thickness of the shell.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Carbon Dioxide-Water Emulsions for Enhanced Oil Recovery and Permanent Sequestration of Carbon Dioxide

This project involves the use of an innovative new invention – Particle Stabilized Emulsions (PSEs) of Carbon Dioxide-in-Water and Water-in-Carbon Dioxide for Enhanced Oil Recovery (EOR) and Permanent Sequestration of Carbon Dioxide. The EOR emulsion would be injected into a semi-depleted oil reservoir such as Dover 33 in Otsego County, Michigan. It is expected that the emulsion would dislocate the stranded heavy crude oil from the rock granule surfaces, reduce its viscosity, and increase its mobility. The advancing emulsion front should provide viscosity control which drives the reduced-viscosity oil toward the production wells. The make-up of the emulsion would be subsequently changed so it interacts with the surrounding rock minerals in order to enhance mineralization, thereby providing permanent sequestration of the injected CO 2 .

02 PETROLEUM↗

Brine-in-crude-oil emulsions at the Strategic Petroleum Reserve

Metastable water-in-crude-oil emulsion formation could occur in a Strategic Petroleum Reserve (SPR) cavern if water were to flow into the crude-oil layer at a sufficient rate. Such a situation could arise during a drawdown from a cavern with a broken-hanging brine string. A high asphaltene content (> 1.5 wt %) of the crude oil provides the strongest predictor of whether a metastable water-in-crude-oil emulsion will form. However there are many crude oils with an asphaltene content > 1.5 wt % that don't form stable emulsions, but few with a low asphaltene content that do form stable emulsions. Most of the oils that form stable emulsions are "sour" by SPR standards indicating they contain total sulfur > 0.50 wt %.

02 PETROLEUM↗

Characterization of polysaccharide from Lonicera japonica Thunb leaves and its application in nano-emulsion

The polysaccharides in honeysuckle leaves (PHL) were separated and characterized for the first time. The nano-emulsion stabilized by PHL and whey protein isolate (WPI) were also fabricated based on the ultrasonic method. The results indicated that PHL was mainly composed of glucose (47.40 mol%), galactose (19.21 mol%) and arabinose (20.21 mol%) with the weight-average molecular weight of 137.97 ± 4.31 kDa. The emulsifier concentration, WPI-to-PHL ratio, ultrasound power and ultrasound time had significant influence on the droplet size of PHL-WPI nano-emulsion. The optimal preparation conditions were determined as following: emulsifier concentration, 1.7%; WPI/PHL ratio, 3:1; ultrasonic power, 700 W; ultrasonic time, 7 min. Under the above conditions, the median diameter of the obtained nano-emulsion was 317.70 ± 5.26 nm, close to the predicted value of 320.20 nm. The protective effect of PHL-WPI emulsion on β-carotene against UV irradiation was superior to that of WPI emulsion. Our results can provide reference for the development of honeysuckle leaves.

Li, Yongchao↗

Nuclear emulsion measurements of the astronauts' radiation exposure on the Apollo-Soyuz mission

On the Apollo-Soyuz mission each astronaut carried one passive dosimeter containing nuclear photographic emulsions, plastic foils, TLD chips, and neutron-activation foils for recording radiation exposure. This report is limited to the presentation of data retrieved from nuclear emulsions. Protons, most of them trapped particles encountered in numerous passes through the South Atlantic Anomaly, contributed by far the largest share to the mission dose. Their linear energy transfer (LET) spectrum was established from track and grain counts in a G.5 emulsion which is used for medium and high energies, and from ender counts in a K.2 emulsion which is used for low energies. The total mission fluence of protons was found to be equivalent to a unidirectional beam of 448,500 square centimeters. The broad spectrum was broken down into small LET intervals, which allowed for the computation of absorbed doses and dose equivalents. The totals are 51 millirad and 74 millirem. Counts of disintegration stars in K.2 emulsion are incomplete at present. While a total of 467 stars were identified, counting their prong numbers is still in progress. It was concluded that the Apollo-Soyuz astronauts' radiation exposure as such did not contain anything out of the ordinary that would seem to require special attention.

Schaefer, H. J.↗

The emulsion chamber technology experiment

Photographic emulsion has the unique property of recording tracks of ionizing particles with a spatial precision of 1 micron, while also being capable of deployment over detector areas of square meters or 10's of square meters. Detectors are passive, their cost to fly in Space is a fraction of that of instruments of similar collecting. A major problem in their continued use has been the labor intensiveness of data retrieval by traditional microscope methods. Two factors changing the acceptability of emulsion technology in space are the astronomical costs of flying large electronic instruments such as ionization calorimeters in Space, and the power and low cost of computers, a small revolution in the laboratory microscope data-taking. Our group at UAH made measurements of the high energy composition and spectra of cosmic rays. The Marshall group has also specialized in space radiation dosimetry. Ionization calorimeters, using alternating layers of lead and photographic emulsion, to measure particle energies up to 10(exp 15) eV were developed. Ten balloon flights were performed with them. No such calorimeters have ever flown in orbit. In the ECT program, a small emulsion chamber was developed and will be flown on the Shuttle mission OAST-2 to resolve the principal technological questions concerning space exposures. These include assessments of: (1) pre-flight and orbital exposure to background radiation, including both self-shielding and secondary particle generation; the practical limit to exposure time in space can then be determined; (2) dynamics of stack to optimize design for launch and weightlessness; and (3) thermal and vacuum constraints on emulsion performance. All these effects are cumulative and affect our ability to perform scientific measurements but cannot be adequately predicted by available methods.

Gregory, John C.↗

Rejuvenation of Spent Media via Supported Emulsion Liquid Membranes

The overall goal of this project is to maximize the reuseability of spent fermentation media. Supported emulsion liquid membrane separation, a highly efficient extraction technique, is used to remove inhibitory byproducts during fermentation; thus, improving the yield while reducing the need for fresh water. The key objectives of this study are: Develop an emulsion liquid membrane system targeting low molecular weight organic acids which has minimal toxicity on a variety of microbial systems; Conduct mass transfer studies to allow proper modeling and design of a supported emulsion liquid membrane system; Investigate the effect of gravity on emulsion coalescence within the membrane unit; Access the effect of water re-use on fermentation yields in a model microbial system; Develop a perfusion-type fermentor utilizing a supported emulsion liquid membrane system to control inhibitory fermentation byproducts; Work for the coming year will focus on the determination of toxicity of various solvents, selection of the emulsifying agents, as well as characterizing the mass transfer of hollow-fiber contactors.

Wiencek, John M.↗

Rejuvenation of Spent Media via Supported Emulsion Liquid Membranes

The overall goal of this project was to maximize the reuseability of spent fermentation media. Supported emulsion liquid membrane separation, a highly efficient extraction technique, was used to remove inhibitory byproducts during fermentation; thus, improve the yield while reducing the need for fresh water. The key objectives of this study were: (1) Develop an emulsion liquid membrane system targeting low molecular weight organic acids which has minimal toxicity on a variety of microbial systems. (2) Conduct mass transfer studies to allow proper modeling and design of a supported emulsion liquid membrane system. (3) Investigate the effect of gravity on emulsion coalescence within the membrane unit. (4) Access the effect of water re-use on fermentation yields in a model microbial system. and (5) Develop a perfusion-type fermentor utilizing a supported emulsion liquid membrane system to control inhibitory fermentation byproducts (not completed due to lack of funds)

Wiencek, John M.↗

Tumor Microenvironment Targeting Nano–Bio Emulsion for Synergistic Combinational X-Ray PDT with Oncolytic Bacteria Therapy

Various cancer therapies have been developed, but tumor recurrence with incomplete tumor killing and remaining tumor cells/tissues is frequent in monotherapies. Herein, a nano–bio therapeutic emulsion formulated with multifunctional nanoscintillators and anaerobic Clostridium novyi-NT spores for synergistic image-guided combinational cancer therapy is reported. MRI visible nanoscintillators (NSs) are synthesized with a NaGdF 4 :Tb,Ce@NaGdF 4 core/shell structure for an image-guided X-ray photodynamic therapy (PDT) of the normoxic peripheral tumor. An anaerobic oncolytic bacterium (C. novyi-NT) therapy is combined to treat the hypoxic central tumor tissues. Photosensitizer-coated NSs (PS-NSs) and C. novyi-NT spores are emulsified with clinically available ethiodized oil (Lipiodol) to be the nano–bio therapeutic emulsion and injected into the tumor with computed tomography image guidance. The distribution of nano–bio therapeutic emulsion, including PS-NSs and anaerobic C. novyi-NT spores in the tumor site, is confirmed by both X-ray and T1-weighted magnetic resonance imaging. Following the image-guided X-ray PDT and anaerobic C. novyi- NT combination treatment, apoptotic cell death in cancer tissues, including both peripheral and central tumor regions, is significantly higher than in the control groups. Finally, this combination therapy approach using a nano–bio therapeutic emulsion is expected to overcome the limitations of conventional cancer therapy, resulting in increased cancer-therapeutic efficacy.

60 APPLIED LIFE SCIENCES↗

Single‐Step Recovery of Water from Stable Crude Oil‐Water Emulsion Using Surface Engineered Hybrid Inorganic‐Polymer Membranes

ABSTRACT Separating crude oil from water remains one of the most stubborn challenges in environmental remediation, especially for surfactant‐stabilized emulsions that resist conventional demulsification methods. Here, we report a scalable strategy for achieving near‐zero‐discharge separation of crude oil emulsions using a single superhydrophilic membrane. By applying low‐temperature atomic layer deposition (ALD) of various metal oxides onto activated polyvinylidene fluoride (PVDF) membranes, we create atomically precise surface‐engineered (SE) membranes that maintain an exceptionally strong hydration layer at the membrane‐feed interface, even at high oil loadings. Among the various metal oxides, TiO 2 ‐modified SE membranes exhibit superior interfacial water stability, enabling sustained dewatering of complex crude oil‐water emulsions with >98% separation efficiency and >97% water recovery, compared to only 24.6% water recovery for the pristine membrane. This separation performance surpasses conventional hydrophilic membranes and is comparable to complex Janus channel membrane systems, demonstrating near‐complete emulsion separation using a single membrane. This low‐temperature membrane surface engineering process with atomic‐level precision and potential for scalability via roll‐to‐roll fabrication is promising for industrial‐scale, energy‐efficient water treatment and oil spill remediation applications.

Sengupta, Bratin [Applied Materials Division Argon↗

Janus Nanoparticle Emulsions as Chiral Nanoreactors for Enantiomerically Selective Ligand Exchange

Abstract Janus nanoparticles capped with a hydrophobic and hydrophilic hemisphere of mercapto ligands can self‐assemble into hollow, emulsion‐like nanostructures in controlled media. As the nanoparticle emulsions are chiroptically active exhibiting a plasmonic circular dichroism absorption in the visible range, they can be exploited as a unique chiral nanoreactor by selective encapsulation of d ‐enantiomer into the water phase of the water‐in‐oil emulsions for directional functionalization of the nanoparticles and endow the resulting nanoparticles with select chirality. This is demonstrated in the present study with gold Janus nanoparticles functionalized with (hydrophobic) hexanethiolates and (hydrophilic) 3‐mercapto‐1,2‐propandiol, and d , l ‐cysteine is used as the molecular probe. Experimental results demonstrate that d ‐cysteine is the preferred enantiomers entrapped within the nanoparticle emulsions, where the ensuing ligand exchange reaction is initially confined to the hydrophilic face of the Janus nanoparticles. This suggests that with a deliberate control of the reaction time, chiral Janus nanoparticles can be readily prepared by ligand exchange reactions even with a racemic mixture of ligands.

Lu, Jia En↗

Emulsion separation and fouling of electrospun polyacrylonitrile membranes for produced water applications

Produced water (PW) is a complex mixture generated during oil and gas extraction. Membrane fouling by hydrocarbon emulsions (sizes < 10 µm) challenges most PW treatment systems. Electrospinning has the possibility of creating microporous membranes that present unique performance properties, though evaluations of these characteristics are largely restricted to unrealistic dead-end configurations. Three different nanofibrous polyacrylonitrile (PAN) membranes were synthesized by electrospinning and their performances contrasted with a commercially available PAN membrane. Feed solutions included synthetic oil and solvent emulsions and a PW from an operating well-site. Two nanoparticles, polyaniline (PANI) and reduced graphene oxide (RGO), were studied for enhancing the oleophobicity and fouling properties of the electrospun PAN membranes. Electrospun membranes showed higher porosities (68 to 80 %) and water permeance values (9,000 to 10,000 LMH/bar) relative to that for the commercially available PAN membrane (44 % and 8,800 LMH/bar). All electrospun membranes provided superior performance characteristics when treating the emulsions and PW relative to the commercial membrane. Furthermore, the PANI integrated membrane demonstrated the greatest resistance to oil/solvent emulsion fouling and comparable performance to the RGO and PAN membrane treating the PW.

03 NATURAL GAS↗

New Developments and Applications of Superheated Emulsions: Warhead Verification and Special Nuclear Material Interdiction

In recent years, neutron detection with superheated emulsions has received renewed attention thanks to improved detector manufacturing and read-out techniques, and thanks to successful applications in warhead verification and special nuclear material (SNM) interdiction. Detectors are currently manufactured with methods allowing high uniformity of the drop sizes, which in turn allows the use of optical read-out techniques based on dynamic light scattering. Furthermore, small detector cartridges arranged in 2D matrices are developed for the verification of a declared warhead without revealing its design. For this application, the enabling features of the emulsions are that bubbles formed at different times cannot be distinguished from each other, while the passive nature of the detectors avoids the susceptibility to electronic snooping and tampering. Large modules of emulsions are developed to detect the presence of shielded special nuclear materials hidden in cargo containers ‘interrogated’ with high energy X-rays. In this case, the enabling features of the emulsions are photon discrimination, a neutron detection threshold close to 3 MeV and a rate-insensitive read-out.

d’Errico, Francesco↗

Nuclear emulsion measurements of the astronauts' radiation exposures on Skylab missions 2, 3, and 4

On the Skylab missions, Ilford G.5 and K.2 emulsions were flown as part of passive dosimeter packs carried by the astronauts on their wrists. Due to the long mission times, latent image fading and track crowing imposed limitations on a quantitative track and grain count analysis. For Skylab 2, the complete proton energy spectrum was determined within reasonable error limits. A combined mission dose equivalent of 2,490 millirems from protons, tissue stars and neutrons was measured on Skylab 2. A stationary emulsion stack, kept in a film vault drawer on the same mission, displayed a highly structured directional distribution of the fluence of low-energy protons (enders) reflecting the local shield distribution. On the 59 and 84-day mission 3 and 4, G.5 emulsions had to be cut on the microtom to 5-7 microns for microscopic examination. Even so, the short track segments in such thin layers precluded a statistically reliable grain count analysis. However, the K.2 emulsions still allowed accurate proton ender counts without special provisions.