Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ELECTRON TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A study of 60 GHz intersatellite link applications

Applications of intersatellite links operating at 60 GHz are reviewed. Likely scenarios, ranging from transmission of moderate and high data rates over long distances to low data rates over short distances are examined. A limited parametric tradeoff is performed with system variables such as radiofrequency power, receiver noise temperature, link distance, data rate, and antenna size. Present status is discussed and projections are given for both electron tube and solid state transmitter technologies. Monolithic transmit and receive module technology, already under development at 20 to 30 GHz, is reviewed and its extension to 60 GHz, and possible applicability is discussed.

Anzic, G.

Xenon-Ion Drilling of Tungsten Films

High-velocity xenon ions used to drill holes of controlled size and distribution through tungsten layer that sheaths surface of controlled-porosity dispenser cathode of traveling wave-tube electron emitter. Controlled-porosity dispenser cathode employs barium/calcium/ aluminum oxide mixture that migrates through pores in cathode surface, thus coating it and reducing its work function. Rapid, precise drilling technique applied to films of other metals and used in other applications where micron-scale holes required. Method requires only few hours, as opposed to tens of hours by prior methods.

Garner, C. E.

Performance of the FOS Detectors in a Variable External Magnetic Field

We present the results of an investigation of the in-orbit performance of the Digicon detectors in the Faint Object Spectrograph (FOS), conducted as part of the commissioning phase of the Hubble Space Telescope. This paper includes orbital results on detector background noise, sensor image stability, and photometric stability along with several typical FOS observations. New techniques for suppressing cosmic ray induced background and geomagnetic induced image motion in electron tube detectors are also discussed.

Fitch, J. E.

Effects of 1- and 2-MeV electrons on photomultiplier tubes

Various types of photomultiplier tubes useful for space applications were irradiated with 1- and 2-MeV electrons at Van Allen radiation belt fluxes of 100,000 to 10 millions electrons/sq cm-sec. The increase in the dark current due to electron irradiation was observed at various bias voltages under worst-case conditions (no shielding). Results were presented in the form of dark current plotted against electron flux. All the tubes tested showed extremely large increases in dark current. Tube types 541A, 6217, 6199, and 6903 exhibited the largest increases under irradiation, whereas type 1P22 was affected the least. All the damage observed was transient. The luminescence produced in the optical window probably accounts for a large part of the dark-current increases, but there were some effects possibly due to direct irradiation of the photocathode and dynode chain.

Beatty, M. E., III

Effects of Structural Deformation and Tube Chirality on Electronic Conductance of Carbon Nanotubes

A combination of large scale classical force-field (UFF), density functional theory (DFT), and tight-binding Green's function transport calculations is used to study the electronic properties of carbon nanotubes under the twist, bending, and atomic force microscope (AFM)-tip deformation. We found that in agreement with experiment a significant change in electronic conductance can be induced by AFM-tip deformation of metallic zigzag tubes and by twist deformation of armchair tubes. The effect is explained in terms of bandstructure change under deformation.

Svizhenko, Alexei

Split glass tube assures quality in electron beam brazing

Sealed enclosure of heat-resistant glass tubing and silicone rubber molds provide good visibility for electron beam brazing of metal tubes in an inert gas atmosphere. The glass tubing and rubber molds, which are bonded together, are easily applied to and removed from the brazing area by operation of a clamp.

Kressin, W. J.

Three-Dimensional Electron Optics Model Developed for Traveling-Wave Tubes

A three-dimensional traveling-wave tube (TWT) electron beam optics model including periodic permanent magnet (PPM) focusing has been developed at the NASA Glenn Research Center at Lewis Field. This accurate model allows a TWT designer to develop a focusing structure while reducing the expensive and time-consuming task of building the TWT and hot-testing it (with the electron beam). In addition, the model allows, for the first time, an investigation of the effect on TWT operation of the important azimuthally asymmetric features of the focusing stack. The TWT is a vacuum device that amplifies signals by transferring energy from an electron beam to a radiofrequency (RF) signal. A critically important component is the focusing structure, which keeps the electron beam from diverging and intercepting the RF slow wave circuit. Such an interception can result in excessive circuit heating and decreased efficiency, whereas excessive growth in the beam diameter can lead to backward wave oscillations and premature saturation, indicating a serious reduction in tube performance. The most commonly used focusing structure is the PPM stack, which consists of a sequence of cylindrical iron pole pieces and opposite-polarity magnets. Typically, two-dimensional electron optics codes are used in the design of magnetic focusing devices. In general, these codes track the beam from the gun downstream by solving equations of motion for the electron beam in static-electric and magnetic fields in an azimuthally symmetric structure. Because these two-dimensional codes cannot adequately simulate a number of important effects, the simulation code MAFIA (solution of Maxwell's equations by the Finite-Integration-Algorithm) was used at Glenn to develop a three-dimensional electron optics model. First, a PPM stack was modeled in three dimensions. Then, the fields obtained using the magnetostatic solver were loaded into a particle-in-cell solver where the fully three-dimensional behavior of the beam was simulated in the magnetic focusing field. For the first time, the effects of azimuthally asymmetric designs and critical azimuthally asymmetric characteristics of the focusing stack (such as shunts, C-magnets, or magnet misalignment) on electron beam behavior have been investigated. A cutaway portion of a simulated electron beam focused by a PPM stack is illustrated.

Kory, Carol L.

Hard- and software problems of spaced meteor observations by optical electronics

An optical electronic facility is being used for meteor observations along with meteor radars and astronomical TV. The main parts of the facility are cameras using UM-92 optical electronic image tubes. The three cascade optical electronic image tube with magnetic focusing has a 40 mm cathode and resolution in the center of up to 30 pairs of lines/mm. The photocathode is of a multislit S-20 type. For meteor spectra observations, replica gratings of 200 and 300 lines/mm are used as the dispersive element.

Shafiev, R. I.

Miniature, low-power X-ray tube using a microchannel electron generator electron source

Embodiments of the invention provide a novel, low-power X-ray tube and X-ray generating system. Embodiments of the invention use a multichannel electron generator as the electron source, thereby increasing reliability and decreasing power consumption of the X-ray tube. Unlike tubes using a conventional filament that must be heated by a current power source, embodiments of the invention require only a voltage power source, use very little current, and have no cooling requirements. The microchannel electron generator comprises one or more microchannel plates (MCPs), Each MCP comprises a honeycomb assembly of a plurality of annular components, which may be stacked to increase electron intensity. The multichannel electron generator used enables directional control of electron flow. In addition, the multichannel electron generator used is more robust than conventional filaments, making the resulting X-ray tube very shock and vibration resistant.

Elam, Wm. Timothy

A NASA First in Nano-Technology: Nanoscale Vacuum Tube for Radiation Immune Electronics

Vacuum provides the fastest electron speed, better than any semiconductor. Nevertheless vacuum tubes were bulky, fragile and consumed much power. Now nanotechnology has enabled fabrication of vacuum tubes at nanoscale in silicon chips. The speed, immunity to radiation and high temperature operation are expected to revolutionize space electronics.

Ingrid Desilestre

NOVEL METHODS FOR IN SITU HIGH DENSITY SURFACE CLEANING SCRUBBING OF ULTRAHIGH VAC LONG NARROW TUBES TO REDUCE SECONDARY ELECTRON YIELD AND OUT GASSING

This project developed new methods for cleaning the inside surfaces of very long, narrow vacuum tubes used in particle accelerators. Traditional cleaning approaches are expensive, slow, or difficult to implement in accelerator tunnels. We designed and tested a portable plasma discharge cleaning system that uses lower-cost microwave and magnetron technologies to reduce outgassing and secondary electron emission from stainless steel and copper surfaces. The system, called the Plasma Discharge Test System (PDTS), allows accelerator components to be scrubbed more efficiently, which can improve performance and reduce maintenance costs for research and industrial applications.

POOLE, JOE HENRY [PRESIDENT]

Coupling of Armchair and Zigzag Tubes to a Free Electron Metal

The effect of nanotube chirality is of prime importance in determining its electronic properties. We address the issue of how chirality affects the coupling of a nanotube to metal contacts. We model coupling of armchair and zigzag nanotubes to metal contacts, in both the side- and end-contacted geometries. In the side-contacted geometry, the coupling of armchair and metallic-zigzag nanotubes to a free electron metal are significantly different. Namely, it is possible to drive a larger current through a metallic-zigzag nanotube. The predicted difference holds good when both (a) the entire circumference and (b) only a finite sector of the nanotube makes contact to the metal electrode. It might be possible to observe the predicted difference between armchair and zigzag nanotubes using gold contacts.

Anantram, M. P.