Electric arc stabilization in crossed convective and magnetic fields.
Electric arc stabilization in crossed convective and magnetic fields, discussing column slanting relationship to widening near downstream electrode
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Electric arc stabilization in crossed convective and magnetic fields, discussing column slanting relationship to widening near downstream electrode
The composition of slags of an electric arc furnace (EAF) in a commercial melt shop was systematically analyzed with a focus on slag foaming. Basic behavior of FeO in an EAF slag was confirmed using fundamental thermodynamics. Monoxide ([Mg,Fe,Mn]O = M’O) and spinel ([Mg,Fe]Al{sub 2}O{sub 4}) phases in EAF slag were confirmed by X-ray diffraction analysis, and these results were interpreted in the context of equilibrium cooling calculation using FactSage™ software. Furthermore, the distribution of MgO with respect to the M’O-saturation limit at different basicity ratios (=CaO/SiO{sub 2}=C/S) and temperatures was evaluated. In particular, the relationship between MgO and FeO for C/S ratios ranging from 1.3 to 1.6 was considered with reference to phase equilibria. Foam height was affected by slag viscosity (η) and gas generation according to changes in C/S ratio and FeO content. Foaming index (Σ) decreased with the increasing C/S ratio and FeO content. The measured foam heights were relatively higher than the calculated values, and the result indicates that the effect of M’O on slag foaming in commercial process is remarkable. Therefore, slag chemistry should be optimized based on thermodynamic considerations and thermophysical properties to achieve good foaming characteristics.
The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.
Magnetically rotated electric arc air heater using strong magnetic field and copper electrodes
A magnetically rotated electric-arc air heater has been developed that is novel in that an intense magnetic field of the order of 10,000 to 25,000 gauss is employed. This field is supplied by a coil that is connected in series with the arc. Experimentation with this heater has shown that the presence of an intense magnetic field transverse to the arc results in diffusion of the arc and that the arc has a positive effective resistance. With the field coil in series with the arc, highly stable arc operation is obtained from a battery power supply. External ballast is not required to stabilize the arc when it is operating at maximum power level. The electrode erosion rate is so low that the airstream contamination is no more than 0.07 percent and may be substantially less.
In this investigation a series of small-scale tests were conducted, which were sponsored by the Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) and performed at Sandia National Laboratories (SNL). These tests were designed to better understand localized particle dispersion phenomena resulting from electrical arcing faults. The purpose of these tests was to better characterize aluminum particle size distribution, rates of production, and morphology (agglomeration) of electrical arc faults. More specifically, this effort characterized ejected particles and high-energy dispersion, where this work characterized HEAF electrical characteristics, particle movement/distributions, and morphology near the arc. The results and measurements techniques from this investigation will be used to inform an energy balance model to predict additional energy from aluminum involvement in the arc fault. The experimental setup was developed based on prior work by KEMA and SNL for phase-to-ground and phase-to-phase electrical circuit faults. The small-scale tests results should not be expected to be scale-able to the hazards associated with full-scale HEAF events. Here, the test voltages will consist of four different levels: 480V, 4160V, 6900V and 10kV, based on those realized in nuclear power plant (NPP) HEAF events.
Use of insensitive high explosives (IHEs) has significantly improved ammunition safety because of their remarkable insensitivity to violent cook–off, shock and impact. Triamino–trinitrobenzene (TATB) is the IHE used in many modern munitions. Previously, lightning simulations in different test configurations have shown that the required detonation threshold for standard density TATB at ambient and elevated temperatures (250 °C) has a sufficient margin over the shock caused by an arc from the most severe lightning. In this paper, the Braginskii model with Lee–More channel conductivity prescription is used to demonstrate how electrical arcs from lightning could cause detonation in TATB. The steep rise and slow decay in typical lightning pulse are used in demonstrating that the shock pressure from an electrical arc, after reaching the peak, falls off faster than the inverse of the arc radius. For detonation to occur, two necessary detonation conditions must be met: the Pop–Plot criterion and minimum spot size requirement. The relevant Pop–Plot for TATB at 250 °C was converted into an empirical detonation criterion, which is applicable to explosives subject to shocks of variable pressure. The arc cross–section was required to meet the minimum detonation spot size reported in the literature. Furthermore, one caveat is that when the shock pressure exceeds the detonation pressure the Pop–Plot may not be applicable, and the minimum spot size requirement may be smaller.
As an efficient oxygen supplying technology, coherent jets are widely applied in electric arc furnace (EAF) steelmaking processes to strengthen chemical energy input, speed up smelting rhythm, and promote the uniformity of molten bath temperature and compositions. Recently, the coherent jet with CO{sub 2} and O{sub 2} mixed injection (COMI) was proposed and demonstrated great application potentiality in reducing the dust production in EAF steelmaking. In the present study, based on the eddy dissipation concept model, a computational fluid dynamics model of coherent jets with COMI was built with the overall and detailed chemical kinetic mechanisms (GRI-Mech 3.0). Compared with one-step combustion reaction, GRI-Mech 3.0 consists of 325 elementary reactions with 53 components and can predict more accurate results. The numerical simulation results were validated by the combustion experiment data. The jet behavior and the fluid flow characteristics of coherent jets with COMI under 298 K and 1700 K (25 °C and 1427 °C) were studied and the results showed that for coherent jets with COMI, the chemical effect of CO{sub 2} significantly weakened the shrouding combustion reactions of CH{sub 4} and the relative importance of the chemical effect of CO{sub 2} increases with CO{sub 2} concentration increasing. The potential core length of coherent jet decreases with the volume fraction of CO{sub 2} increasing. Moreover, it also can be found that the potential core length of coherent jets was prolonged with higher ambient temperature.
Remote method initiates an electric arc over a large range of gaps between two water-cooled electrodes of an arc-heated wind tunnel without disassembling the arc unit. This type of starting system can be used on both three-phase ac arc heaters and dc arc heaters.
We investigated the effect of direct reduced iron (DRI) addition on dephosphorization of molten steel by electric arc furnace (EAF) slag at 1823 K (1550 °C). Various phenomena such as CO gas evolution and slagmaking by gangue oxides in DRI were experimentally observed at each reaction step. Thermodynamic behaviors of phosphorus, oxygen, and carbon were strongly dependent on DRI content. Basicity, which is the thermodynamic driving force of dephosphorization, decreased with the increasing DRI content because SiO{sub 2} concentration in the slag was proportional to DRI addition. The excess free energy of P{sub 2}O{sub 5} increased with the increasing SiO{sub 2} content in slag. A higher DRI content made dephosphorization difficult by decreasing the basicity and stability of P{sub 2}O{sub 5} in the slag. Therefore, when using DRI in EAF process, it is very important to control the basicity of slag.
Heat transfer phenomena in electric arcs - design and testing of arc tunnel modification
The present study investigates the effect of addition of waste rubber tires on the combustion behavior of its blends with coke for carbon injection in electric arc furnace steelmaking. Waste rubber tires were mixed in different proportions with metallurgical coke (MC) (10:90, 20:80, 30:70) for combustion and pyrolysis at 1473 K in a drop tube furnace (DTF) and thermogravimetric analyzer (TGA), respectively. Under experimental conditions most of the rubber blends indicated higher combustion efficiencies compared to those of the constituent coke. In the early stage of combustion the weight loss rate of the blends is much faster compared to that of the raw coke due to the higher volatile yield of rubber. The presence of rubber in the blends may have had an impact upon the structure during the release and combustion of their high volatile matter (VM) and hence increased char burnout. Measurements of micropore surface area and bulk density of the chars collected after combustion support the higher combustion efficiency of the blends in comparison to coke alone. The surface morphology of the 30% rubber blend revealed pores in the residual char that might be attributed to volatile evolution during high temperature reaction in oxygen atmosphere. Physical properties and VM appear to have a major effect upon the measured combustion efficiency of rubber blends. The study demonstrates that waste rubber tires can be successfully co-injected with metallurgical coke in electric arc furnace steelmaking process to provide additional energy from combustion. 44 refs., 11 figs., 2 tabs.
The following paper describes an approach to process modeling and simulation of the gas phase in an electric arc furnace (EAF). The work presented represents the continuation of research by Logar, Dovžan, and Škrjanc on modeling the heat and mass transfer and the thermochemistry in an EAF. Due to the lack of off-gas measurements, Logar et al. modeled a simplified gas phase under consideration of five gas components and simplified chemical reactions. The off-gas is one of the main continuously measurable EAF process values and the off-gas flow represents a heat loss up to 30 pct of the entire EAF energy input. Therefore, gas phase modeling offers further development opportunities for future EAF optimization. This paper presents the enhancement of the previous EAF gas phase modeling by the consideration of additional gas components and a more detailed heat and mass transfer modeling. In order to avoid the increase of simulation time due to more complex modeling, the EAF model has been newly implemented to use an efficient numerical solver for ordinary differential equations. Compared to the original model, the chemical components H{sub 2}, H{sub 2}O, and CH{sub 4} are included in the gas phase and equilibrium reactions are implemented. The results show high levels of similarity between the measured operational data from an industrial scale EAF and the theoretical data from the simulation within a reasonable simulation time. In the future, the dynamic EAF model will be applicable for on- and offline optimizations, e.g., to analyze alternative input materials and mode of operations.
Arc model describing symptomatic behavior of fluctuating mode when axial gas flow is superimposed on electric arc
Imploding wire trigger technique for high shock velocity electric arc drivers in shock tubes
A viewgraph presentation on electrical arc ignition testing of spacesuit materials is shown. The topics include: 1) Background; 2) Test Objectives; 3) Test Sample Materials; 4) Test Methods; 5) Scratch Test Objectives; 6) Cotton Scratch Test Video; 7) Scratch Test Results; 8) Entire Date Plot; 9) Closeup Data Plot; 10) Scratch Test Problems; 11) Poke Test Objectives; 12) Poke Test Results; 13) Poke Test Problems; 14) Wire-break Test Objectives; 15) Cotton Wire-Break Test Video; 16) High Speed Cotton Wire-break Test Video; 17) Typical Data Plot; 18) Closeup Data Plot; 19) Wire-break Test Results; 20) Wire-break Tests vs. Scratch Tests; 21) Urethane-coated Nylon; and 22) Moleskin.
We investigated the effect of Al-C composite pellets (ACCP) on the reduction behavior of FeO in electric arc furnace (EAF) slag and the iron recovery at different n{sub Al}/(n{sub Al} + n{sub C}) at 1823 K (1550 °C). A carbothermic reaction was the dominant process at n{sub Al}/(n{sub Al} + n{sub C}) < 0.4, whereas aluminothermic reduction was the major process at n{sub Al}/(n{sub Al} + n{sub C}) > 0.6; these observations are based on the final content of FeO and Al{sub 2}O{sub 3} in the molten slag. The aluminum and carbon present in the ACCP competitively affected the reaction stoichiometry (i.e., the material balance) between the production of CO + Al{sub 2}O{sub 3} and the consumption of FeO. Iron recovery increased up to a yield of approx. 90 pct as the n{sub Al}/(n{sub Al} + n{sub C}) ratio increased. Because Al in the ACCP readily reacts to reduce FeO in the molten slag, iron recovery is proportional to the n{sub Al}/(n{sub Al} + n{sub C}) ratio. The precipitation of solid compounds in the slag phase, such as monoxide ([Mg,Fe]·O) and spinel (MgO·Al{sub 2}O{sub 3}), occurred during FeO reduction; this was experimentally confirmed as well as by thermochemical computation. Furthermore, we proposed a schematic reaction mechanism in the present study.
A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.