Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Triphenylamine/benzothiadiazole-based compounds for non-doped orange and red fluorescent OLEDs with high efficiencies and low efficiency roll-off

Long-wavelength materials are key for development of pure-color and white organic light-emitting devices (OLEDs). An organic molecule, combining hybridized local electron and charge-transfer (HLCT) states and aggregation-induced emission (AIE), not only breaks the 5% external quantum efficiency (EQE) limit but also overcomes emission quenching. Herein, we designed and synthesized four novel donor–acceptor compounds of TBAN, TBT, TBAT, and TABAT using triphenylamine (TPA) as the donor, benzothiadiazole (BT) as the acceptor, and anthracene (AN) as a bridge. We found that the emission peaks of TBAN, TBT, TBAT and TABAT are located at 596, 615, 580 and 546 nm, respectively. We successfully applied them to non-doped OLEDs, and the resulting devices exhibited excellent performance. For example, the optimal TBAN-based OLEDs showed a maximum luminance of 74 820 cd m –2 , a current efficiency of 12.1 cd A –1 and a maximum EQE of 5.7% with low roll-off. Additionally, the device with TBAN as both the emitter and hole-transport material also exhibited high efficiency that is comparable to that of an NPB-based device. Furthermore, this work demonstrates that it is feasible to obtain excellent orange and red emitters by employing BT- and TPA-based D–A architectures.

36 MATERIALS SCIENCE↗

Deferred Payment Loans for Energy Efficiency: Case Study of a Low- and Moderate-Income Home Improvement Financing Model and Potential Application to Energy Efficiency Projects

Energy efficiency can provide important benefits for low- and moderate-income households such as lower utility bills and healthier, more comfortable homes, but the upfront costs of efficiency improvements are often a barrier. Extending financing to these households can help overcome this barrier but presents its own challenges, including the financial burden of monthly payments and the risk of incurring the repercussions of nonpayment. The deferred payment loan model can give low- and moderate-income households access to energy efficiency without the financial burden of monthly payments while mitigating the risk of nonpayment. From a program sponsor perspective, when grant funds are limited or unavailable, the model provides certain advantages of both grants and financing. Like a grant, target recipients have minimal risk, but like a loan, funds can serve multiple participants since the funding can be revolved. Organizations in several parts of the country have employed the model to provide safe, healthy homes by paying for home repair and home improvement. This case study provides a detailed overview of the deferred payment loan program for home improvements known as the Home Repair Program run by the Opportunity Council, a Community Action Agency (CAA) serving three counties in Washington State. This case study also considers two other CAA-administered deferred payment loan programs – one in Wisconsin and another in Michigan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MFVI Energy Efficiency Audit Training - Module 1.1: Introduction to Efficient Lighting [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing lighting systems. As such, it will assist its user in determining the optimal lighting for a given space and then identifying the most efficient means of delivering that lighting.

21CPP↗

Carbazole-Based Hole Transport Polymer for Methylammonium-Free Tin-Lead Perovskite Solar Cells with Enhanced Efficiency and Stability

As the most commonly used hole transport material (HTM) in tin-lead (Sn-Pb) perovskite solar cells (PSCs), poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS) limits the power conversion efficiency (PCE) and stability of the PSCs due to its acidic characteristics. Herein, an easily synthesized polymer HTM poly[(phenyl)imino[9-(2-ethylhexyl)carbazole]-2,7-diyl] (CzAn) with a shallow highest occupied molecular orbital (HOMO) level of -4.95 eV is used in a p-i-n structure, methylammonium-free, Sn-Pb PSC to replace PEDOT:PSS. Upon optimization using doping and surface engineering, high quality Sn-Pb PSCs could be successfully fabricated, boosting the PCE to 22.6% (stabilized PCE of 21.3%) compared with 21.2% for PEDOT:PSS. The perovskite films prepared on the modified CzAn HTM possess improved crystallinity, reduced trap-state density, and larger carrier mobility resulting in PSCs with greatly improved stability.

carrier mobility↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Building Energy Codes and Grid-Interactive Efficient Buildings: How building energy codes can enable a more dynamic and energy-efficient built environment

This report considers the role of national model codes to promote grid-interactive efficient buildings (GEBs) as part of the modernization of the U.S. electricity grid. It introduces GEBs, describes their ability to support a clean, resilient grid, and considers challenges and approaches for incorporating GEB measures into national model energy codes and standards. Desirable traits of GEB include being low energy, low peaking, and responsive to grid needs, and minimizing the curtailment of renewable energy resources. In addition, the future grid incurs a time and locational value on these types of building services. Accounting for these considerations in future code development requires a continuation and expansion of code-minimum energy efficiency requirements and inclusion of demand responsive and load flexibility measures while ensuring annual use and cost reductions. Also, efforts to include GEB measures in codes will be limited until they are fully developed into an American National Standards Institute (ANSI)-approved standard. Then it would be straightforward to address GEB measures through points or packages and/or scoring requirements. Otherwise, the building code would have to describe each specific grid responsive strategy. This document reviews topics pertinent to considering codes in this context. Specifically, the study presents the status and direction of current building energy codes, the future smart grid, low-energy buildings, and grid-integrated buildings. The report concludes with recommendations for future code development activities to support low-energy, grid-interactive buildings in order to provide added value to building owners, the grid, and society.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Highly Efficient Ternary Solar Cells with Efficient Förster Resonance Energy Transfer for Simultaneously Enhanced Photovoltaic Parameters

Introducing a third component into organic bulk heterojunction solar cells has become an effective strategy to improve photovoltaic performance. Meanwhile, the rapid development of non-fullerene acceptors (NFAs) has pushed the power conversion efficiency (PCE) of organic solar cells (OSCs) to a higher standard. In this study, a series of fullerene-free ternary solar cells are fabricated based on a wide bandgap acceptor, IDTT-M, together with a wide bandgap donor polymer PM6 and a narrow bandgap NFA Y6. Insights from the morphological and electronic characterizations reveal that IDTT-M has been incorporated into Y6 domains without disrupting its molecular packing and sacrificing its electron mobility and work synergistically with Y6 to regulate the packing pattern of PM6, leading to enhanced hole mobility and suppressed recombination. IDTT-M further functions as an energy-level mediator that increases open-circuit voltage ( V OC ) in ternary devices. In addition, efficient Förster resonance energy transfer (FRET) between IDTT-M and Y6 provides a non-radiative pathway for facilitating exciton dissociation and charge collection. As a result, the optimized ternary device features a significantly improved PCE up to 16.63% with simultaneously enhanced short-circuit current ( J SC ), V OC , and fill factor (FF).

36 MATERIALS SCIENCE↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MOF-Transformed In 2 O 3-x @C Nanocorn Electrocatalyst for Efficient CO 2 Reduction to HCOOH

For electrochemical CO 2 reduction to HCOOH, an ongoing challenge is to design energy efficient electrocatalysts that can deliver a high HCOOH current density (J HCOOH ) at a low overpotential. Indium oxide is good HCOOH production catalyst but with low conductivity. In this work, we report a unique corn design of In 2 O 3-x @C nanocatalyst, wherein In 2 O 3-x nanocube as the fine grains dispersed uniformly on the carbon nanorod cob, resulting in the enhanced conductivity. Excellent performance is achieved with 84% Faradaic efficiency (FE) and 11 mA cm –2 J HCOOH at a low potential of – 0.4 V versus RHE. At the current density of 100 mA cm –2 , the applied potential remained stable for more than 120 h with the FE above 90%. Density functional theory calculations reveal that the abundant oxygen vacancy in In 2 O 3-x has exposed more In 3+ sites with activated electroactivity, which facilitates the formation of HCOO* intermediate. Operando X-ray absorption spectroscopy also confirms In 3+ as the active site and the key intermediate of HCOO* during the process of CO 2 reduction to HCOOH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tree growth, transpiration, and water-use efficiency between shoreline and upland red maple (Acer rubrum) trees in a coastal forest

Coastal shoreline forests are vulnerable to seawater exposure, the impacts of which will increase due to sea-level rise, but the longterm adaption strategies and vulnerability of coastal forests are not well understood. We used whole-tree transpiration, leaf water potential, tree-ring width, and tree-ring d13C (a proxy for intrinsic water use efficiency, iWUE) to examine the long-term adaption strategies of red maple (Acer rubrum) trees at the coastal interface (i.e., shoreline) and nearby upland in Maryland, USA. Red maple trees that grew along the shoreline and were exposed to slightly saline water (up to two PSU) had higher transpiration rates than those growing in the nearby upland forest during a wet year, but these differences disappeared during a normal precipitation year. Shoreline trees grew more slowly than upland trees over the last four decades, but these growth differences have disappeared in the last six years. Shoreline and upland trees had similar variation in iWUE, indicating that higher transpiration rates of the seawater exposed trees did not translate into differences in water use efficiency. There were no differences in predawn and midday water potential between upland and shoreline trees, suggesting no water stress occurs in shoreline trees. These findings indicate that urrent soil salinity is below the threshold to constrain coastal red maple physiological activities.

Wang, Wenzhi↗