Design and numerical characterization of a crossover EBIS

For the investigation of highly charged ions, a crossover EBIS (XEBIS) was developed at the University of Frankfurt. In contrast to conventional EBIS/T devices the compression of the electron beam is achieved by electrostatic focusing to a crossover point in the interaction region. This concept allows a compact and simple design. Simulations performed with EGUN show a perveance of 2.1×10{sup −7} A/V{sup 3/2} for the realized gun system. In the interaction region the electron beam has a density of around 10 A/cm{sup 2} and a minimum radius of 0.15 mm. The XEBIS has a total length of 112 mm with a trap length of 26 mm. It is designed for electron beam energies of up to 6 keV/q. The storage capacity of the trap region is in the order of 1×10{sup 8} charges. Charge state breeding studies with CBSIM indicate for the noble gases as maximal achievable charge state Ar{sup 16+}, Kr{sup 30+} and Xe{sup 35+}. Thus ion beam currents of around 2.04 nA assuming 50 Hz repetition rate can be expected. The emittance of the extracted beam is approximated to 8 mm mrad. After completion of the construction phase, the XEBIS will be installed for first performance investigations at a dedicated test bench, equipped with a fast Faraday Cup (FC), a retarding field spectrometer, a luminescence screen and optical diagnostics. Subsequently the XEBIS will serve as source for highly charged ions at different experimental setups.

74 ATOMIC AND MOLECULAR PHYSICS↗

Emittance Reduction between EBIS LINAC and Booster by Electron Beam Cooling; Is Single Pass Cooling Possible?

Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in less than one meter.

43 PARTICLE ACCELERATORS↗

Part II/Addendum Electron Beam Cooling between EBIS LINAC and Booster; Is Single Pass Cooling Possible?

Due to some miscommunication, incomplete data was erroneously used in examining electron beam cooling for reducing momentum of gold ions exiting the EBIS LINAC before injection into the booster. Corrected calculations still indicate that single pass cooling is, in principle, feasible; momentum spread can be reduced by an order of magnitude in about one meter. Preliminary results suggest that this cooling deserves further consideration.

43 PARTICLE ACCELERATORS↗

Issues Concerning High Current Low Energy Electron Beams Required for Ion Cooling between EBIS LINAC and Booster

Some issues, regarding a low energy high current electron beam that will be needed for electron beam cooling to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster, are examined. Options for propagating such an electron beam, as well as the effect of neutralizing background plasma on electron and ion beam parameters are calculated. Computations and some experimental data indicate that none of these issues is a show stopper.

43 PARTICLE ACCELERATORS↗

EBIS Beam Intensity Online Optimization with GPTune and Offline Analysis with XGBoost

The application of machine learning techniques to accelerator research has led to significant breakthroughs in optimization strategies. This paper presents a pioneering study using a novel machine learning algorithm, GPTune, to optimize beam intensity by adjusting parameters in the EBIS injection and extraction beam lines. Our research demonstrates substantial improvements, achieving a remarkable 22% and 70% increase in beam intensity at two separate measurement locations.

43 PARTICLE ACCELERATORS↗

Emittance Reduction between EBIS LINAC and Booster by Electron Beam Cooling; Is Single Pass Cooling Possible?

Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in less than one meter.

43 PARTICLE ACCELERATORS↗

Part II/Addendum Electron Beam Cooling between EBIS LINAC and Booster; Is Single Pass Cooling Possible?

Due to some miscommunication, incomplete data was erroneously used in examining electron beam cooling for reducing momentum of gold ions exiting the EBIS LINAC before injection into the booster. Corrected calculations still indicate that single pass cooling is, in principle, feasible; momentum spread can be reduced by an order of magnitude in about one meter. Preliminary results suggest that this cooling deserves further consideration.

43 PARTICLE ACCELERATORS↗

Issues concerning high current lower energy electron beams required for ion cooling between EBIS LINAC and booster

Some issues, regarding a low energy high current electron beam that will be needed for electron beam cooling to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster, are examined. Options for propagating such an electron beam, as well as the effect of neutralizing background plasma on electron and ion beam parameters are calculated. Computations and some experimental data indicate that none of these issues is a show stopper.

43 PARTICLE ACCELERATORS↗

Dipole magnet for use of RHIC EBIS HEBT line.

Construction and magnetic field measurement of dipole magnets for RHIC-EBIS HEBT line have completed. These magnets will be used to guide highly charged ion beams ranging from proton to Uranium provided by a new injector toward the Booster ring in BNL. In this paper, overview of the magnetic design of the dipoles and results of magnetic field measurement are summarized.

43 PARTICLE ACCELERATORS↗

Construction of the BNL EBIS preinjector

A new heavy ion preinjector, consisting of an Electron Beam Ion Source (EBIS), an RFQ, and IH linac, is under construction at Brookhaven National Laboratory. This preinjector win provide ions of any species at an energy of 2 MeV/u, resulting in increased capabilities for the Relativistic Heavy Ion Collider, and the NASA Space Radiation Laboratory programs. The RF'Q has been commissioned with beam, and most of the remaining elements are either installed or being assembled.

43 PARTICLE ACCELERATORS↗

Beam commissioning of the RFQ for the RHIC-EBIS project

Beam commissioning of a new 4 rod RFQ has started at Brookhaven National Laboratory (BNL). The RFQ will accelerate intense heavy ion beams provided by an Electron Beam ion Source (EBIS) up to 300 keV/u. The RFQ will accelerate a range of Q/M from 1 to 1/6, and the accelerated beam will be finally delivered to the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL). The first beam was successfully accelerated and the bunch structures of He{sup +} and Cu{sup 10+} beams were measured. The further beam tests are in progress.

43 PARTICLE ACCELERATORS↗

The Design and Development of The EBIS LEBT Solenoid Power Supply

This power supply was designed and developed at Brookhaven National Laboratory (BNL) as part of a new ion preinjector system called EBIS (Electron Beam Ion Source). It consists of a charging power supply, a capacitor bank, a discharge and recovery circuit and control circuits. The output is fed through cables into a solenoid magnet. The magnet's inductance is 1.9mH. The maximum charging voltage is 1000V. The power supply output is a half sine wave of 13ms duration. The repetition rate is 5Hz. The power supply output can be set to any value between 250A and 1900A in one second in order to accommodate the varying species of ions specified by different machine users.

43 PARTICLE ACCELERATORS↗

The Electron Beam Ion Source (EBIS)

Brookhaven National Lab has successfully developed a new pre-injector system, called the Electron Beam Ion Source, for the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory science programs. The first of several planned improvemen

43 PARTICLE ACCELERATORS↗

ForCent model development and testing using the Enriched Background Isotope Study experiment

The ForCent forest ecosystem model was developed by making major revisions to the DayCent model including: (1) adding a humus organic pool, (2) incorporating a detailed root growth model, and (3) including plant phenological growth patterns. Observed plant production and soil respiration data from 1993 to 2000 were used to demonstrate that the ForCent model could accurately simulate ecosystem carbon dynamics for the Oak Ridge National Laboratory deciduous forest. A comparison of ForCent versus observed soil pool {sup 14}C signature ({Delta} {sup 14}C) data from the Enriched Background Isotope Study {sup 14}C experiment (1999-2006) shows that the model correctly simulates the temporal dynamics of the {sup 14}C label as it moved from the surface litter and roots into the mineral soil organic matter pools. ForCent model validation was performed by comparing the observed Enriched Background Isotope Study experimental data with simulated live and dead root biomass {Delta} {sup 14}C data, and with soil respiration {Delta} {sup 14}C (mineral soil, humus layer, leaf litter layer, and total soil respiration) data. Results show that the model correctly simulates the impact of the Enriched Background Isotope Study {sup 14}C experimental treatments on soil respiration {Delta} {sup 14}C values for the different soil organic matter pools. Model results suggest that a two-pool root growth model correctly represents root carbon dynamics and inputs to the soil. The model fitting process and sensitivity analysis exposed uncertainty in our estimates of the fraction of mineral soil in the slow and passive pools, dissolved organic carbon flux out of the litter layer into the mineral soil, and mixing of the humus layer into the mineral soil layer.

09 BIOMASS FUELS↗

Eliminating unwanted electrons in EBIS devices

In electron beam ion sources, step-wise ionization to high charge states is accomplished by magnetically confined electron beam. Electron space charge and high voltage electrodes confine the ions. The relativistic heavy ion collider (RHIC) ion source Debye length meets requirements for instabilities with free source of energy to grow. Electrons stripped from ions provide energy for a variety of microinstabilities to grow. Possible solution is to remove these electrons from the trap to a drift tube biased to higher voltage than the other tubes between the gate and the collector. If needed, a split drift tube for bleeding these electrons to ground is added.