Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hierarchical Modeling to Enhance Spectrophotometry Measurements—Overcoming Dynamic Range Limitations for Remote Monitoring of Neptunium

A robust hierarchical model has been demonstrated for monitoring a wide range of neptunium concentrations (0.75–890 mM) and varying temperatures (10–80 °C) using chemometrics and feature selection. The visible–near infrared electronic absorption spectrum (400–1700 nm) of monocharged neptunyl dioxocation (Np(V) = NpO2+) includes many bands, which have molar absorption coefficients that differ by nearly 2 orders of magnitude. The shape, position, and intensity of these bands differ with chemical interactions and changing temperature. These challenges make traditional quantification by univariate methods unfeasible. Measuring Np(V) concentration over several orders of magnitude would typically necessitate cells with varying path length, optical switches, and/or multiple spectrophotometers. Alternatively, the differences in the molar extinction coefficients for multiple absorption bands can be used to quantify Np(V) concentration over 3 orders of magnitude with a single optical path length (1 mm) and a hierarchical multivariate model. In this work, principal component analysis was used to distinguish the concentration regime of the sample, directing it to the relevant partial least squares regression submodels. Each submodel was optimized with unique feature selection filters that were selected by a genetic algorithm to enhance predictions. Through this approach, the percent root mean square error of prediction values were ≤1.05% for Np(V) concentrations and ≤4% for temperatures. This approach may be applied to other nuclear fuel cycle and environmental applications requiring real-time spectroscopic measurements over a wide range of conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust Large-Scale Dynamic Windows using Reversible Metal Electrodeposition

This project funded the study and development of dynamic windows based on reversible metal electrodeposition (RME). Dynamic windows allow user control over light and heat flow into and out of buildings, which offer both advantages in building aesthetics (with worker productivity improvement of 2%) and energy efficiency (up to 20% savings) compared to static controls such as low emissivity coatings and blinds/shades. Despite these advantages, dynamic windows, which traditionally rely on electrochromic metal oxides or conductive organic molecules for light modulation have failed to significantly impact the market due to issues related to cost, color, and optical dynamic range. Dynamic windows based on reversible metal electrodeposition (RME) are an exciting alternative approach and have the potential to overcome the issues associated with traditional technologies. A RME dynamic window is an electrochemical cell that modulates light using the reversible electrodeposition of metal on and off a transparent conducting oxide (TCO), which serves as the working electrode. The electrolyte has nearly colorless metal salts dissolved, and application of a cathodic potential on the TCO reduces the metal cations across the TCO surface to their metallic form, making a thin film that is efficient at blocking out light. A reverse in polarity oxidizes the metal, where it dissolves into solution, returning the window back to transparent. The counter electrode typically employed is a metal mesh, which is used to balance the electrochemical reactions happening on the TCO working electrode. These RME dynamic windows have the largest dynamic range (capable of reaching <<0.1% transmission) with color neutral tinting of any existing technology using solution processed techniques, which positions the technology as a promising candidate to penetrate the residential market. We have successfully scaled up the windows from 25 cm2 to 929 cm 2 , and we have demonstrated significant improvements to both the cycle life (10,000 cycles in a 3-electrode half-cell) and shelf life (>1 month) of our windows. We have published our work in high impact journals (6 published and 2 manuscripts in prep), filed 5 patents, and have incorporated TYNT Technologies to commercialize the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Engineering activatable promoters for scalable and multi-input CRISPRa/i circuits

Dynamic, multi-input gene regulatory networks (GRNs) are ubiquitous in nature. Multilayer CRISPR-based genetic circuits hold great promise for building GRNs akin to those found in naturally occurring biological systems. We develop an approach for creating high-performing activatable promoters that can be assembled into deep, wide, and multi-input CRISPR-activation and -interference (CRISPRa/i) GRNs. By integrating sequence-based design and in vivo screening, we engineer activatable promoters that achieve up to 1,000-fold dynamic range in an Escherichia coli-based cell-free system. These components enable CRISPRa GRNs that are six layers deep and four branches wide. We show the generalizability of the promoter engineering workflow by improving the dynamic range of the light-dependent EL222 optogenetic system from 6-fold to 34-fold. Additionally, high dynamic range promoters enable CRISPRa systems mediated by small molecules and protein–protein interactions. We apply these tools to build input-responsive CRISPRa/i GRNs, including feedback loops, logic gates, multilayer cascades, and dynamic pulse modulators. Our work provides a generalizable approach for the design of high dynamic range activatable promoters and enables classes of gene regulatory functions in cell-free systems.

42 ENGINEERING↗

Development of inducible promoters for regulating gene expression in Clostridium tyrobutyricum for biobutanol production

Abstract Clostridium tyrobutyricumis an anaerobe known for its ability to produce short‐chain fatty acids, alcohols, and esters. We aimed to develop inducible promoters for fine‐tuning gene expression inC. tyrobutyricum. Synthetic inducible promoters were created by employing anEscherichia coli lacoperator to regulate the thiolase promoter (PCathl) fromClostridium acetobutylicum, with the best one (LacI‐Pto4s) showing a 5.86‐fold dynamic range with isopropyl β‐d‐thiogalactoside (IPTG) induction. A LT‐Pt7 system with a dynamic range of 11.6‐fold was then created by combining LacI‐Pto4s with a T7 expression system composing of RNA polymerase (T7RNAP) and Pt7lacpromoter. Furthermore, two inducible expression systems BgaR‐PbgaLA and BgaR‐PbgaLB with a dynamic range of ~40‐fold were developed by optimizing a lactose‐inducible expression system fromClostridium perfringenswith modified 5′ untranslated region (5′ UTR) and ribosome‐binding site (RBS). BgaR‐PbgaLB was then used to regulate the expressions of a bifunctional aldehyde/alcohol dehydrogenase encoded byadhE2 and butyryl‐CoA/acetate Co‐A transferase encoded bycat1 inC. tyrobutyricumwild type and Δcat1::adhE2, respectively, demonstrating its efficient inducible gene regulation. The regulatedcat1 expression also confirmed that the Cat1‐catalyzed reaction was responsible for acetate assimilation inC. tyrobutyricum. The inducible promoters offer new tools for tuning gene expression inC. tyrobutyricumfor industrial applications.

Biotechnology & Applied Microbiology↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Dynamic Voltage Range Studies of Piezoelectric Multilayer Actuators at Low Temperatures

Piezo actuators are used for resonance control in superconducting linacs. In high accelerating gradients linacs, such as those operated in a pulsed mode, the piezos require a large operating voltage. This is due to the Lorentz forced detuning which causes a large frequency shift and is compensated with an active piezo-tuning system. In this high dynamic voltage range the piezo is expected to warm up drastically due to it being in an insulated vacuum. This study characterizes the dielectric properties (capacitance, dielectric losses), the piezo stroke (from geophone), and thermal properties such as heating. Results obtained in the temperature range of 20K to 300K will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Ultrafast perturbation of magnetic domains by optical pumping in a ferromagnetic multilayer

Ultrafast optical pumping of spatially nonuniform magnetic textures is known to induce far-from-equilibrium spin transport effects. Here, we use ultrafast x-ray diffraction with unprecedented dynamic range to study the laser-induced dynamics of labyrinth domain networks in ferromagnetic CoFe/Ni multilayers. We detected azimuthally isotropic, odd order, magnetic diffraction rings up to fifth order. The amplitudes of all three diffraction rings quench to different degrees within 1.6 ps. In addition, all three of the detected diffraction rings both broaden by 15% and radially contract by 6% during the quench process. We are able to rigorously quantify a 31% ultrafast broadening of the domain walls via Fourier analysis of the order-dependent quenching of the three detected diffraction rings. Here, the broadening of the diffraction rings is interpreted as a reduction in the domain coherence length, but the shift in the ring radius, while unambiguous in its occurrence, remains unexplained. In particular, we demonstrate that a radial shift explained by domain-wall broadening can be ruled out. With the unprecedented dynamic range of our data, our results provide convincing evidence that labyrinth domain structures are spatially perturbed at ultrafast speeds under far-from-equilibrium conditions, albeit the mechanism inducing the perturbations remains yet to be clarified.

36 MATERIALS SCIENCE↗

Point spread function deconvolution using a convolutional autoencoder

A major issue in optical astronomical image analysis is the combined effect of the instrument’s point spread function (PSF) and the atmospheric seeing that blurs images and changes their shape in a way that is band and time-of-observation dependent. In this work we present a very simple neural network based approach to nonblind image deconvolution that relies on feeding a convolutional autoencoder (CAE) input images that have been preprocessed by convolution with the corresponding PSF and its regularized inverse, a method which is both conceptually simple and computationally less intensive. We also present here, a new approach for dealing with limited input dynamic range of neural networks compared to the dynamic range present in astronomical images.

79 ASTRONOMY AND ASTROPHYSICS↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications, while maintaining high dynamic range and a wide operational frequency range. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable analog filter channel for signal spectrum analysis and signal discrimination is presented. Project specifications required a programmable, high-order, monolithic bandpass filter channel with small chip area, low power consumption, high dynamic range, and wide operational frequency range. The 8th-order filter channel presented in this work provides an effective Q-factor of 4.5 and a minimum dynamic range (DR) of approximately 85 dB, while allowing for tuning across a range of center frequencies from 2 kHz to 100 kHz, with power consumption of a single 8th-order filter channel measured at 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology was selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2nd-order filter cells, resulting in a single 8th-order filter channel, fabricated in 130-nm 1.2-V CMOS technology, suitable for use in monolithic integrated spectral analysis (MISA1) applications.

Long, Gavin B.↗

FY21 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g., height, color and grayscale values; all as functions of a location in a plane projection). A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data, flag significant features, execute Machine Learning (ML) algorithms, output parameters for trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Features can be called out by user-specified thresholds, manual labeling or machine learning algorithms when they have been completed. The ability to rapidly label data is important because of the volume of data required for training machine learning algorithms. The GUI has the flexibility to allow addition of improved ML algorithms, methods for data visualization, and statistical computations. Statistical analyses via the GUI include areas of pits within a defined range of pit depths, correlations between Red-Green-Blue (RGB) or grayscale intensity and relative surface height, covariances between values associated with features, and feature histograms. The development of supervised machine learning algorithms, however, has been hindered by a lack of training data. The machine learning algorithms for crack identification are being refined but require improvements to the true positive rate for crack detection. This shortcoming is an artifact of the limited training data currently available, perhaps more so than the structure of the neural networks. At present, the best results are had from a consensus over an ensemble of randomly generated Deep Neural Network (DNN) or Convolutional Neural Network (CNN) algorithms. Although the consensus accuracy method has yielded optimum true positive and true negative rates in excess of 80%, additional validation testing is necessary. In addition to the suite of LCM data that was initially used, and which represents the majority of the work presented in this report, WAMS image data was also reviewed at a preliminary level. The review included a comparison between image resolution and dynamic range for each method. WAMS (ZON file) image data was found to have a pixel pitch of 3.69μm compared to 1 μm for the LCM (vk4 file) data, which implies a lower resolution for the WAMS images. Conversely, the ratio of dynamic range of the WAMS data to the LCM data was approximately 41:20 for height data, suggesting that information from WAMS should more accurately determine the depth of pits. At present, the significance of the greater dynamic range of the WAMS data relative to the LCM data has not yet been evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AFM Microcantilever With a Collocated AlN Sensor-Actuator Pair: Enabling Efficient Q-Control for Dynamic Imaging

This manuscript presents a novel microcantilever with an embedded piezoelectric sensor-actuator pair for dynamic atomic force microscopy (AFM). The transducer pair is constructed from a two-layered AlN stack. Stacking the piezoelectric transducers in this manner leads to a minimal feedthrough from actuation to sense electrode, granting a high dynamic range frequency response for dynamic mode AFM. The cantilever's design allows for dual mode operation at 1 st and 2 nd resonance modes. High resolution tapping mode imaging results are reported, while the cantilever is operated at these modes. A feedback control loop is used to modify quality factor of the 1 st mode of the cantilever, using a positive position feedback (PPF) controller. Here, a faster response time is achieved by reducing the Q-factor, enabling the cantilever to track the topography at a higher scan rate. Results of bimodal AFM imaging are reported, using amplitude changes of the 1 st mode for surface topography, while material properties are encoded in phase changes of the 2 nd mode.

47 OTHER INSTRUMENTATION↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

AugerPrime surface detector electronics

Operating since 2004, the Pierre Auger Observatory has led to major advances in our understanding of the ultra-high-energy cosmic rays. The latest findings have revealed new insights that led to the upgrade of the Observatory, with the primary goal of obtaining information on the primary mass of the most energetic cosmic rays on a shower-by-shower basis. In the framework of the upgrade, called AugerPrime, the 1660 water-Cherenkov detectors of the surface array are equipped with plastic scintillators and radio antennas, allowing us to enhance the composition sensitivity. To accommodate new detectors and to increase experimental capabilities, the electronics is also upgraded. This includes better timing with up-to-date GPS receivers, higher sampling frequency, increased dynamic range, and more powerful local processing of the data. In this paper, the design characteristics of the new electronics and the enhanced dynamic range will be described. The manufacturing and test processes will be outlined and the test results will be discussed. The calibration of the SD detector and various performance parameters obtained from the analysis of the first commissioning data will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using the Gerchberg-Saxton algorithm to reconstruct nonmodulated pyramid wavefront sensor measurements

Adaptive optics (AO) is a technique to improve the resolution of ground-based telescopes by correcting, in real-time, optical aberrations due to atmospheric turbulence and the telescope itself. With the rise of Giant Segmented Mirror Telescopes (GSMT), AO is needed more than ever to reach the full potential of these future observatories. One of the main performance drivers of an AO system is the wavefront sensing operation, consisting of measuring the shape of the above mentioned optical aberrations. Aims. The non-modulated pyramid wavefront sensor (nPWFS) is a wavefront sensor with high sensitivity, allowing the limits of AO systems to be pushed. The high sensitivity comes at the expense of its dynamic range, which makes it a highly non-linear sensor. We propose here a novel way to invert nPWFS signals by using the principle of reciprocity of light propagation and the Gerchberg-Saxton (GS) algorithm. We test the performance of this reconstructor in two steps: the technique is first implemented in simulations, where some of its basic properties are studied. Then, the GS reconstructor is tested on the Santa Cruz Extreme Adaptive optics Laboratory (SEAL) testbed located at the University of California Santa Cruz. This new way to invert the nPWFS measurements allows us to drastically increase the dynamic range of the reconstruction for the nPWFS, pushing the dynamics close to a modulated PWFS. The reconstructor is an iterative algorithm requiring heavy computational burden, which could be an issue for real-time purposes in its current implementation. However, this new reconstructor could still be helpful in the case of many wavefront control operations. In conclusion, this reconstruction technique has also been successfully tested on the Santa Cruz Extreme AO Laboratory (SEAL) bench where it is now used as the standard way to invert nPWFS signal.

47 OTHER INSTRUMENTATION↗

Not-quite-transcendental Functions for Logarithmic Interpolation of Tabulated Data

From tabulated nuclear and degenerate equations of state to photon and neutrino opacities and nuclear reaction rates, tabulated data is ubiquitous in computational astrophysics. The dynamic range that must be covered by these tables typically spans many orders of magnitude. Here we present a novel strategy for accurately and performantly interpolating tabulated data that spans these large dynamic ranges. We demonstrate the efficacy of this strategy in tabulated lookups for nuclear and terrestrial equations of state. We show that this strategy is a faster drop-in replacement for linear interpolation of logarithmic grids.

79 ASTRONOMY AND ASTROPHYSICS↗

Pythia8 Quark and Gluon Jets (float8 e4m3FN)

A float8 (e4m3FN) quantized version of the quark and gluon jet dataset originally published by Komiske, Metodiev, and Thaler (Zenodo record 3164691). Only the 20-file subset without charm and bottom quark jets is included here. All simulation parameters and jet selection criteria are identical to the original: Pythia 8.226, √s = 14 TeV Quarks from WeakBosonAndParton:qg2gmZq, gluons from WeakBosonAndParton:qqbar2gmZg with the Z decaying to neutrinos FastJet 3.3.0, anti-k_t jets with R = 0.4 p_T^jet ∈ [500, 550] GeV, |y^jet| < 1.7 There are 20 files, each in compressed NumPy format (QG_jets_fp8e4m3fn_0.npz through QG_jets_fp8e4m3fn_19.npz). Each file contains two arrays: X: (100000, M, 4) — 50k quark and 50k gluon jets, randomly sorted, padded to max multiplicity M, with particle features (pt, rapidity, azimuthal angle, pdgid) y: (100000,) — jet labels, gluon = 0, quark = 1 Since NumPy has no native fp8 dtype, X is stored as float32, but the values have been quantized through TensorFlow's float8_e4m3fn type and carry only fp8 precision. The quantization procedure is as follows: a global per-channel scale factor is computed from the absolute maximum value across all 20 chunks (with FP8_MAX = 448.0, the maximum representable value of e4m3FN). Each chunk is then scaled into the fp8 dynamic range, round-tripped through tf.experimental.float8_e4m3fn, and scaled back. This global scaling ensures a consistent quantization grid across the full dataset. The y labels are unchanged. Users should be aware that e4m3FN has limited dynamic range and precision. We recommend verifying this format is appropriate for your application; for a less aggressive reduction see the float16 and float32 versions linked below. If you use this dataset, please cite the original Zenodo record and its associated paper: Komiske, Metodiev, Thaler, Energy Flow Networks: Deep Sets for Particle Jets, JHEP 01 (2019) 121, arXiv:1810.05165

DiLullo, Nicholas [Brown University] (ORCID:000000↗