Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and validation of fully open-source R2S shutdown dose rate capabilities in OpenMC *

We present the first fully open-source capabilities for shutdown dose rate (SDR) calculations of fusion energy facilities based on the Rigorous 2-Step (R2S) methodology. These capabilities have been implemented in the OpenMC Monte Carlo particle transport code, building on its existing capabilities while also leveraging new features that have been added to the code to support SDR calculations, such as decay photon source generation. Each of the individual physics components in the R2S workflow—neutron transport, activation, decay photon source generation, and photon transport—have been verified through code-to-code comparisons with MCNP6.2 and FISPACT-II 4.0. These comparisons generally demonstrate excellent agreement between codes for each of the physics components. The full cell-based R2S workflow was validated by performing a simulation of the first experimental campaign from the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For short cooling times, the dose calculated by OpenMC agrees with the experimental measurements within the stated experimental uncertainties. For longer cooling times, an overprediction of the shutdown dose was observed relative to experiment, which is consistent with previous studies in the literature. Altogether, these features constitute a combination of capabilities in a single, open-source codebase to provide the fusion community with a readily-accessible option for SDR calculations and a platform for rapidly analyzing the performance of fusion technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Bremsstrahlung Converter Designs for Ultra High Dose Rate Radiotherapy Systems

Ultra-high dose rates (UHDR) have been shown to improve the therapeutic index in the treatment of cancer using external beam radiotherapy in many preclinical settings by inducing the so-called “FLASH” effect [1]; however, the underlying biological and physical mechanism(s) are still unknown. Recent work has been to expand the energy range of photons used in UHDR studies from keV photons generated in synchrotron to photons less than 8 MeV produced by accelerated electrons undergoing the bremsstrahlung interaction [2]. This work is a part of the FLASH-Experimental X-ray small Animal Conformal Therapy (FLASH-EXACT) project is aimed at producing a preclinical system that induces the FLASH effect with photons >10 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of Monte Carlo code SHIFT for MSBR dose rate calculations

This paper presents a study that applied the Monte Carlo code SHIFT to calculate the radiological environment within a detailed Molten Salt Breeder Reactor (MSBR) model. It represents one of the first applications of the SHIFT code in stand-alone simulations for non-light water reactors to help demonstrate the code's potential uses in the design, licensing, and operation of advanced reactors. The radiological conditions of the MSBR were modeled when the reactor is at two different operation modes: normal full power and a drained state. The Forward Weighted-Consistent Adjoint Driven Importance Sampling (FW-CADIS) hybrid method in SHIFT was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the SHIFT simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

A new platform for ultra-high dose rate radiobiological research using the BELLA PW laser proton beamline

Abstract Radiotherapy is the current standard of care for more than 50% of all cancer patients. Improvements in radiotherapy (RT) technology have increased tumor targeting and normal tissue sparing. Radiations at ultra-high dose rates required for FLASH-RT effects have sparked interest in potentially providing additional differential therapeutic benefits. We present a new experimental platform that is the first one to deliver petawatt laser-driven proton pulses of 2 MeV energy at 0.2 Hz repetition rate by means of a compact, tunable active plasma lens beamline to biological samples. Cell monolayers grown over a 10 mm diameter field were exposed to clinically relevant proton doses ranging from 7 to 35 Gy at ultra-high instantaneous dose rates of 10 7 Gy/s. Dose-dependent cell survival measurements of human normal and tumor cells exposed to LD protons showed significantly higher cell survival of normal-cells compared to tumor-cells for total doses of 7 Gy and higher, which was not observed to the same extent for X-ray reference irradiations at clinical dose rates. These findings provide preliminary evidence that compact LD proton sources enable a new and promising platform for investigating the physical, chemical and biological mechanisms underlying the FLASH effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fitting the RESRAD External Dose Rate Coefficients Model to the FGR 15 Data

FGR15 (Bellamy et al. 2025) lists external dose rate coefficients for radionuclides in soil, water and air. It has five tables of coefficients for contaminated soil; one for radionuclides on the surface of the soil and one each for radionuclides in soil layers of 1 cm, 5 cm, 15 cm and infinite thickness. Each table contains 7512 coefficients, quantifying the external dose rate from each of the 1252 ICRP107 radionuclides, to each of the six reference persons of different ages.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Oxidative Modifications to Short Peptides Using Low Dose Rate X-Rays

The method of X-ray footprinting and mass spectrometry (XFMS) using high flux synchrotron X-ray sources has become an established method in structural biology and is based on the radiolytic production of hydroxyl radicals, which oxidatively modify protein sidechains. While other methods of producing hydroxyl radicals are available, one benefit of using high flux density sources is that hydroxyl radical scavenging reactions can be minimized, and exposure times kept short to minimize secondary reactions. Here we present an application of the XFMS method using low dose rate X-rays from a commercial instrument. We demonstrate the feasibility of the approach using short peptides, characterizing the oxidative modifications +14, +16, and +32 Da under both aerobic and low oxygen conditions, and we additionally quantify the hydrogen peroxide production for various doses using the low dose rate source. These results provide fundamental information on the oxidative damage to peptides due to hydroxyl radicals using a low dose rate X-ray source.

X-ray methods↗

High Dose and Dose Rate 60 Co γ-Irradiation of High-Density Polyethylene

We have irradiated high-density polyethylene ribbons and cylinders to ~200 kGy at a dose rate of ~5 kGy day -1 , using a 60 Co source. The radiolytically-generated gas consists almost entirely of H 2 . Based on the time- and dose-dependence of the outgassing, we have determined the radiation- chemical yield for the evolved H 2 , as well as the diffusion coefficient of H 2 in HDPE. We find that the evolved gas yield G evolved depends on the interplay of sample geometry, experimental timescale, and the diffusion coefficient of H 2 in HDPE. When these factors facilitate completion of diffusion prior to gas quantification, such as for sub-mm-thickness ribbons, we measure a time- and dose-invariant value of G evolved = 0.0076 cm 3 std. H 2 J -1 that is in agreement with literature reports. When sample geometry and experiment timescale do not permit completion of diffusion, we measure a time- and dose-dependent value of G evolved . We have developed a model for the transient outgassing behavior of the cylinders, and fitted it to the experimental data. Based on these fits, we estimate a room-temperature diffusivity of D H 2 /HDPE ≈ 1.67 ± 0.12 x 10 -6 cm 2 s -1 for H 2 in HDPE, in good agreement with literature values. At present, the effects of dose rate and γ-photon energy on HDPE gas yield are not known and require further investigation.

36 MATERIALS SCIENCE↗

Assessment of Tools for Molten Salt Reactor Dose Rate Calculations

This report discusses a preliminary assessment of the capabilities of current state-of-the-art stochastic codes Shift and MCNP6 to calculate the ex-core radiation dose rates for a simplified Molten Salt Reactor (MSR) model. The Monte Carlo code Shift has been under significant development in recent years at ORNL as part of the CASL program and is now supported by NEAMS. Originally, Shift was developed for LWR ex-core calculations but with dose rate and shielding calculations specifically requested by the NEAMS program’s MSR industry partners, the MSR Application Drivers team was tasked with assessing Shift for non-LWR applications. This was the first application of the Shift code for non-LWRs and the findings can be considered preliminary due to the activities occurring only over a 5-month period. Attractive features of Shift include massive parallelization and advanced automated variance reduction techniques such as CADIS and FW-CADIS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phase instabilities in austenitic steels during particle bombardment at high and low dose rates

Disruption of phase stability by energetic particle bombardment is a major challenge in designing advanced radiation-tolerant alloys and ion beam processing of nanocomposites. Particularly, ballistic dissolution susceptibility of different solute nanocluster species in alloys is poorly understood. Here, low dose rate neutron irradiations were conducted on a Fe-Cr-Ni based austenitic steel in the BOR-60 reactor (9.4 × 10 -7 dpa/s, 318 °C) followed by accelerated dose rate ion irradiations at multiple temperatures ( 10 -3 dpa/s, 380 – 420 °C). Using atom probe tomography, the stability of radiation-enhanced Cu-rich and radiation-induced Ni-Si-Mn-rich nanoclusters was evaluated. During neutron irradiation, Cu-rich clusters nucleated with their core concentrations progressively increasing with dose, while Ni-Si-Mn-rich clusters formed and evolved into G-phase precipitates. Ion irradiations dramatically altered the nanoclusters. Cu-rich clusters were ballistically dissolved, but Ni-Si-Mn-rich clusters remained stable and coarsened with dose at 400 and 420 °C, highlighting that different nanocluster species in a single microstructure can have innately distinct ballistic dissolution susceptibilities. Solute-specific recoil rates were incorporated into the Heinig precipitate stability model, which shows that in addition to radiation-enhanced diffusion, recovery from ballistic dissolution depends on solute concentration gradient near cluster interfaces. Finally, the combined experimental-modeling study quantified the critical temperatures and damage rates where ballistic dissolution dominates for each cluster species.

36 MATERIALS SCIENCE↗

Biochemical Control and Toxicity Outcomes of Stereotactic Body Radiation Therapy Versus Low-Dose-Rate Brachytherapy in the Treatment of Low- and Intermediate-Risk Prostate Cancer

Low-dose-rate (LDR) brachytherapy and stereotactic body radiation therapy (SBRT) have both shown acceptable outcomes in the treatment of low- and intermediate-risk prostate cancer. Minimal data have been published directly comparing rates of biochemical control and toxicity with these 2 modalities. We hypothesize that LDR and SBRT will provide similar rates of biochemical control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature and dose rate effects on dislocation loop formation and decoration in self-ion irradiated high-purity Fe-Cr model alloys

Body-centered cubic (BCC) Fe-based alloys are promising candidate materials for advanced nuclear reactors. A widespread perception is that the addition of Cr favors the formation of ½ <111> dislocation loops. However, the Cr effects on dislocation loop formation/evolution remain unclear due to the limited experimental studies. In this study, we irradiate ultra-high purity bulk BCC Fe-xCr (x = 3, 5, and 8 wt%) with 6.7-8 MeV Fe ions over a wide range of temperatures (Tirr = 250-500 °C) and dose rates (10⁻⁵ to 10⁻³ dpa/s) to two midrange doses (0.35 and 3.5 dpa). The major irradiation-induced microstructures are loop decoration along non-screw dislocation lines at low temperatures and high dose rates as well as self-assembled loops at elevated temperatures. Post-irradiation Burgers vector analysis via g•b method on loops and electron tomography reveals that <001> preponderance is observable in all irradiated Fe-Cr samples at elevated temperature, resulting from stronger elastic energy originating from <001> edge.

Li, Yao [University of Tennessee (UT)]↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

Effect of heavy ion irradiation dose rate and temperature on α' precipitation in high purity Fe-18%Cr alloy

Cr-rich alpha prime precipitates (CrRP) induce hardening and embrittlement of FeCr alloys, but the kinetics of CrRP formation due to particle irradiation are not well understood. In this study, Fe18wt.%Cr alloy in solid solution state and pre-aged to produce relatively coarse CrRP was irradiated with 8 MeV Fe ions. The irradiation conditions involved two midrange doses of 0.37 and 3.7 displacements per atom (dpa), a wide range of dose rates (10 -5 –10 -3 dpa/s) and temperatures (300–450 °C). The distributions of CrRP after irradiation were studied with atom probe tomography (APT). The critical irradiation conditions to suppress CrRP formation were identified as 300 °C and 10-3 dpa/s; CrRP formation occurred readily at lower dose rates or higher temperatures. From 0.37 to 3.7 dpa, CrRP were observed to slightly grow at 350 °C and strongly coarsen at 450 °C. Specimens with pre-existing CrRP evolved into a similar precipitate distribution as detected after ion irradiation on solution annealed specimens at 300–350 °C to 0.37 dpa, indicating that the precipitate microstructure approaches a quasi-equilibrium for doses <1 dpa. Limited shrinking of pre-existing CrRP was observed after irradiation at 450 °C to 0.37 dpa, indicating a higher recovery rate at this temperature. Additionally, the evolution of CrRP is quantitatively explained by employing corrections to the historic Nelson-Hudson-Mazey precipitate stability model, and a radiation modified precipitation mechanism is proposed to account for the competition between radiation enhanced diffusion and ballistic dissolution which results in the modifications on both size and solute concentration of CrRP.

36 MATERIALS SCIENCE↗

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark↗