Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Documented Safety Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Reliability Modeling Methodology for Independent Approaches on Parallel Runways Safety Analysis

This document is an adjunct to the final report An Integrated Safety Analysis Methodology for Emerging Air Transport Technologies. That report presents the results of our analysis of the problem of simultaneous but independent, approaches of two aircraft on parallel runways (independent approaches on parallel runways, or IAPR). This introductory chapter presents a brief overview and perspective of approaches and methodologies for performing safety analyses for complex systems. Ensuing chapter provide the technical details that underlie the approach that we have taken in performing the safety analysis for the IAPR concept.

Babcock, P.↗

Plutonium Oxide Containment and the Potential for Water-Borne Transport as a Consequence of ARIES Oxide Processing Operations

The question of oxide containment during processing and storage has become a primary concern when considering the continued operability of the Plutonium Facility (PF-4) at Los Alamos National Laboratory (LANL). An Evaluation of the Safety of the Situation (ESS), “Potential for Criticality in a Glovebox Due to a Fire” (TA55-ESS-14-002-R2, since revised to R3) first issued in May, 2014 summarizes these concerns: “The safety issue of fire water potentially entering a glovebox is: the potential for the water to accumulate in the bottom of a glovebox and result in an inadvertent criticality due to the presence of fissionable materials in the glovebox locations and the increased reflection and moderation of neutrons from the fire water accumulation.” As a result, the existing documented safety analysis (DSA) was judged inadequate and, while it explicitly considered the potential for criticality resulting from water intrusion into gloveboxes, criticality safety evaluation documents (CSEDs) for the affected locations did not evaluate the potential for fire water intrusion into a glovebox.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of thermolytic hydrogen generation rate of tank farm simulated and actual waste

To support resolution of Potential Inadequacies in the Safety Analysis for the Savannah River Site (SRS) Tank Farm, Savannah River National Laboratory conducted research to determine the thermolytic hydrogen generation rate (HGR) with simulated and actual waste. Gas chromatography methods were developed and used with air-purged flow systems to quantify hydrogen generation from heated simulated and actual waste at rates applicable to the Tank Farm Documented Safety Analysis (DSA). Initial simulant tests with a simple salt solution plus sodium glycolate demonstrated the behavior of the test apparatus by replicating known HGR kinetics. Additional simulant tests with the simple salt solution excluding organics apart from contaminants provided measurement of the detection and quantification limits for the apparatus with respect to hydrogen generation. Testing included a measurement of HGR on actual SRS tank waste from Tank 38. A final series of measurements examined HGR for a simulant with the most common SRS Tank Farm organics at temperatures up to 140 °C. The following conclusions result from this testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of thermolytic hydrogen generation rate of tank farm simulated and actual waste

To support resolution of Potential Inadequacies in the Safety Analysis for the Savannah River Site (SRS) Tank Farm, Savannah River National Laboratory conducted research to determine the thermolytic hydrogen generation rate (HGR) with simulated and actual waste. Gas chromatography methods were developed and used with air-purged flow systems to quantify hydrogen generation from heated simulated and actual waste at rates applicable to the Tank Farm Documented Safety Analysis (DSA). Initial simulant tests with a simple salt solution plus sodium glycolate demonstrated the behavior of the test apparatus by replicating known HGR kinetics. Additional simulant tests with the simple salt solution excluding organics apart from contaminants provided measurement of the detection and quantification limits for the apparatus with respect to hydrogen generation. Testing included a measurement of HGR on actual SRS tank waste from Tank 38. A final series of measurements examined HGR for a simulant with the most common SRS Tank Farm organics at temperatures up to 140 °C. The following conclusions result from this testing. HGR was measured for an actual-waste Tank 38 sample. The HGR measurements at 80, 90, 100, and 110 °C were 1.7×10 -7 , 4.7×10 -7 , 5.9×10 -7 , and 2.6×10 -6 ft 3 hr -1 gal -1 , respectively. The Limit of Detection and Limit of Quantification for the HGR measurements were 2.6×10-8 ft3 hr-1 gal-1 and 5.1×10 -8 ft 3 hr -1 gal -1 , respectively. HGR was measured in a high boiling point (HBP) simulant with major known SRS Tank Farm organic compounds. Testing used fresh organics and did not simulate the long-term exposure of these organics already experienced in the waste. Hence, testing is expected to provide high bias to the hydrogen generation rates. The final HGR measurements at 75, 100, and 140 °C were 6.2×10 -7 , 3.0×10 -6 , and 8.1×10 -5 ft 3 hr -1 gal -1 , respectively. Decreases in the HGR were noted at isothermal conditions with steady gas tracer concentration, which clouds development of a temperature dependent correlation for generation rate. While the simulant contains high concentrations of major SRS organics tested at high temperatures found in the 3H Evaporator, this limited data set may not fully bound values under all possible operating conditions. The HGR measurement apparatus was successfully employed to replicate hydrogen production rate experiments. Simulant without deliberately added organic carbon was found to contain approximately 200 mg/L of organic carbon from tramp organics in the reagents used to prepare the solution. The tests using such simulant generated hydrogen at rates consistent with, but somewhat lower than, those predicted at equivalent carbon and aluminum loadings by methods used at the Hanford Site. Prior to identifying the organic contaminants, potential sources of hydrogen in simulants without deliberately added organic carbon were examined. Testing determined that this hydrogen is not due to caustic reaction of organic materials of construction within the reaction vessel, electrolysis due to current leak, anode/cathode reactions, corrosion, or the method of heating employed in the experiment. During the HBP and Tank 38 testing, a peak was identified at a retention time greater than the retention time of the inert tracer of krypton. This peak has been identified as methane, and the data have been reexamined to obtain methane concentrations. For the HBP testing, methane concentration was constant at the highest temperature studied (140 °C) and higher than hydrogen. At the lower temperatures (100 and 75 °C), methane and hydrogen tracked closely, with methane concentration generally lower than hydrogen. For Tank 38, methane concentration was approximately 1/3 of the hydrogen concentration during testing (100 and 110 °C). At lower temperatures for Tank 38 testing (90, 80, and 27 °C), methane fell below the quantification range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Basis of Knowledge for Oxidizing Chemicals in TRU Waste - 18654

A new Waste Isolation Pilot Plant (WIPP) document for implementing new requirements in the WIPP Waste Acceptance Criteria (WAC) titled Basis of Knowledge for Evaluating Oxidizing Chemicals in the TRU waste was issued in July, 2017 and has now been implemented on several waste streams. The February 14, 2014, airborne radiation release in Room 7 of the WIPP underground disposal unit 7 was caused by an exothermic chemical reaction of nitrate oxidizing chemicals and organic materials in a single 55-gallon container. That event exposed hazards not previously evaluated in the WIPP safety basis. A new WIPP Documented Safety Analysis (DSA), Revision 5b, was developed that addressed potential hazards related to the airborne radiation release and evaluated and addressed new fire hazard scenarios. The revised hazards analysis within the DSA specifically included potential chemical exothermic reactions in waste containers and propagating fires. Compliance with WAC was credited as initial conditions to the hazards analysis, and Chapter 18 was added making the WIPP WAC compliance program a safety management program within the DSA. The WIPP DSA, Revision 5b, Chapter 18, and the WIPP WAC require the use of this document when performing the enhanced acceptable knowledge (AK) process on transuranic (TRU) waste determined to contain oxidizing chemicals. The WIPP WAC was revised to address the conditions and requirements of DSA Revision 5b. The use of this Basis of Knowledge (BoK) by WIPP Certified Programs is specified in the WIPP WAC, Appendix H, Enhanced Acceptable Knowledge. This document establishes criteria that must be used by the WIPP Certified Programs to evaluate TRU waste containing one or more oxidizing chemicals to determine acceptability at the WIPP as-is and to identify when additional evaluation or treatment is required. This BoK also includes options and requirements to be used by TRU waste sites when further evaluation, testing, and/or treatment are required. The U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) will review requests, plans, and technical justifications and provide written decisions prior to implementation by the TRU waste sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time Dependence of Methane Generation Rates from Saltstone

This report documents the tests performed to address the requirements listed in the Technical Request, which resulted in a Task Technical & Quality Assurance Plan (TTQAP) and a Run Plan to obtain the required information. The research expands previous scoping work to better understand methane generation in the Saltstone Disposal Facility (SDF). That scoping work demonstrated that methane is produced when sulfide-containing material is added to methylmercury (MeHg), which is found in the SDF Tank 50 feed waste. When Tank 50 waste is combined with grout premix solids dry feed ingredients of cement, slag cement, and fly ash, sulfides are released from the slag cement component of the premix. The prior testing results showed that while the concentration of total mercury was not affected in the pH 14 waste, the MeHg likely reacted with the sulfide contained in the slag. The scoping tests were performed in sealed reactors and thus, methane generation was not measured continuously; rather, it was measured after one hour and after 24 hours. After 24 hours, a large percentage of the MeHg was converted to methane, but after 1 hour only a small percentage of methane was released. It is noteworthy that the methane generation rate (MGR) was greater at the one-hour measurement. The data compiled from the scoping work needed to be expanded to better understand the generation of methane released from grout mixed with Tank 50 waste. This expanded study developed a more extensive knowledge of how and when methane is generated to inform the Documented Safety Analysis (DSA) of the SDF. As such, employing 8 sealed reactors, the methane generation time periods were extended to 2, 4, 6, 18, 30, 48, 72, and 96 hours (4 days). Results are documented herein to determine the capacity for MeHg, contained within Tank 50 salt solution (T50SS) simulant, to produce methane when mixed with saltstone dry feed ingredients, i.e., individual components (cement, slag, and fly ash) or a combination of those components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WSF B696R Calcs

This calculation is applied to the accident analysis scenario of a limited combustibles fire breaching eight SWBs in B696R R1010. For a fire in a building with no breaches, there is only a ground release. The source term (ST) of the deflagration is determined by the Waste Storage Facilities Documented Safety Analysis (Ref. 1). The doses from the release are calculated by using MACCS2 (Ref. 2). This software take hourly meteorological data for a year as input. There are 8760 hours in a year. MACCS2 calculates a dose for each of the 8760 hours, taking into account the associated source term from Reference 1, the wind speed, the stability class (i.e., A through F), the directional sector of the wind (with associated distance to the site boundary). For each directional sector (i.e., 1 through 16) a MACCS2 run was performed. From the total collection of MACCS2 output files, Microsoft Excel is used to extract the dose that correspond to the meteorological conditions of each hour in the year. Note: although MACCS2 inputs a single year of meteorological data, five years are used (2010 through 2014) by performing multiple runs. This is discussed in Section 2.2. Conclusions: The final 95th percentile dose at the collocated worker used for accident analysis of a limited combustibles fire breaching eight SWBs in B696R R1010 is 18.4 rem.

99 GENERAL AND MISCELLANEOUS↗

System Health and Status Reporting is Used to Improve Infrastructure Systems at the Hanford Site - 20449

Reliable physical infrastructure systems are vital to completing the clean-up mission and the start-up and commissioning of new nuclear waste processing facilities at the Hanford Site. Key infrastructure systems at Hanford include water, sewer, and electrical utilities, roads, telecommunications/network systems, and fire systems. All of the infrastructure systems are non-nuclear, General Service systems that are being maintained under formal engineering configuration control and none are specifically credited in any documented safety analysis (DSA). Starting in calendar year 2017, the Hanford Site's infrastructure and services contractor started producing system health and status reports for a total of 15 critical infrastructure systems as means to get a better understanding of each system's health and how it could be improved to ensure better and more reliable service delivery. As the reporting, tracking, and use of the metrics has matured, the number of systems for which reports are being developed has been expanded to a total of 23. Each of the critical infrastructure systems are assigned primary and alternate design authorities that complete qualifications on each assigned system. The design authorities actively manage and maintain configuration control on each of their systems and track metrics associated with availability, maintenance (corrective and preventive), and configuration of the technical baseline. The metrics are based on the principles established in Chapter V of DOE O 420.1C, Facility Safety, [1] and have been tailored as appropriate to each of the key infrastructure systems. An overall assessment of system health is performed and documented on a routine basis (e.g., quarterly). Included in this documentation is a quantitative score for each of the metrics (i.e., availability, maintenance, configuration management) along with results of system walk-downs, description of any permanent design modifications, identification of new or emerging issues and vulnerabilities affecting the system, and an assessment by the design authority of actions necessary to improve the system health score. The overall status scores are calculated using a formula and based on a pre-determined grading scale, a color is assigned for simple presentation. The information gained from developing the reports is being used to (1) assist with making timely and better informed decisions through the use of solid technical bases that are increasing the overall reliability and capabilities of the Site's infrastructure systems as new expense and capital projects in the Reliability Projects Investment Portfolio (RPIP) are prioritized and executed; (2) feed the risk management program, and (3) integrate the technical content of Master Plans that describe the Site's needs for the system and the system's capabilities to meet those future needs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ECAR-6440 Rev 2 MARVEL Hazard Evaluation

This hazard evaluation supports the Microreactor Applications Research, Validation, and Evaluation (MARVEL) Project’s design effort and the development of the preliminary documented safety analysis (PDSA) (addendum to safety analysis report [SAR]-420, “Transient Reactor Test [TREAT] Facility FSAR”) (SAR-420-ADD-1). The hazard evaluation process for the MARVEL project for compliance with the requirements in 10 CFR 830, “Nuclear Safety Management,” follows a process similar to the Licensing Modernization Project (LMP) as outlined in Nuclear Energy Institute (NEI)-18-04, “Risk-Informed Performance-Based Guidance for Non-Light Water Reactor Licensing Basis Development,” and supporting documents. The LMP process is adapted to fit Department of Energy (DOE) reactor regulatory requirements as applicable and appropriate using a graded approach based on the MARVEL microreactor design. This approach provides reasonable assurance of meeting the requirements of 10 CFR 830 for protection of the public, workers, and environment.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-02168

The Savannah River Site (SRS) stores packages containing plutonium (Pu) materials in the K-Area Complex (KAC). The Pu materials are packaged per the DOE 3013 Standard and stored within Model 9975 shipping packages in KAC. The KAC facility DSA (Document Safety Analysis) credits the Model 9975 package to perform several safety functions, including criticality prevention, impact resistance, containment, and fire resistance to ensure the plutonium materials remain in a safe configuration during normal and accident conditions. The Model 9975 package is expected to perform its safety function for at least 12 years from initial packaging. The DSA recognizes the degradation potential for the materials of package construction over time in the KAC storage environment and requires an assessment of materials performance to validate the assumptions of the analysis and ultimately predict service life. As part of the comprehensive Model 9975 package surveillance program, destructive examination of package 9975-02028 was performed following field surveillance in accordance with Reference. Field surveillance of the Model 9975 package in KAC included nondestructive examination of the drum, fiberboard, lead shield and containment vessels. Results of the field surveillance are provided in Attachment 1. Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-02168. For those attributes that were also measured during the field surveillance, no significant changes were observed. Two conditions were identified that do not meet inspection criteria. These conditions are subject to additional investigation and disposition by the Surveillance Program Authority. The conditions include: (1) The lead shield was covered with a white corrosion layer, and (2) Fiberboard thermal conductivity in the axial direction exceeded the specified range. The Surveillance Program Authority was notified of these conditions and will document the findings by surveillance report. All other observations and test results met identified criteria, or were collected for information and trending purposes.

42 ENGINEERING↗

Safety Requirement Management System (SRMS) - Improved Documented Safety Analyses Implementation - 18476

Savannah River Remediation (SRR) developed a new software application, Safety Requirement Management System (SRMS), to improve Documented Safety Analysis (DSA) safety requirement implementation in the Savannah River Site's Liquid Waste facilities. Technical Safety Requirement (TSR) Limited Conditions of Operations (LCOs) and related surveillances were previously tracked using four different applications. Due to their differences and their age, the applications introduced a number of operational challenges and vulnerabilities, including outdated platforms, usage demands beyond original design, and different organizational work processes. SRMS was developed to resolve these issues by using a single web-based approach that provides consistency, wider accessibility, simpler maintenance, and a platform for additional functionality. Other SRS facilities are evaluating the application for its applicability as a standard practice across the site. The new SRMS application decreased the administrative overhead for application maintenance, provided the needed TSR change management functionality, and reduced error precursors with the following advantages: - Consistent process/application across all SRR facilities - More efficient way to track and communicate compliance with DSA time-related requirements (i.e., TSR LCOs and surveillances). - Web-based search capability for LCO entries/exits and a record of surveillance performances. - TSR change management and independent reviews through electronic approvals. For example, the application provides the ability to bundle and stage LCO and surveillance changes associated with a TSR revision. The approval process involves multiple roles from the facility to ensure validity. - Formal configuration management program, fully supported by software life cycle documents. SRMS was implemented at Defense Waste Processing Facility (DWPF) in June 2017, with implementation in all Liquid Waste facilities expected by the end of 2017. Next, SRR plans to expand SRMS functionality to include a linking document database (LDD) to support the DSA requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Retrieval of Transuranic Drums with Deflagration to Detonation Potential from a Vault at the Oak Ridge National Laboratory - 20207

During the final phase of a long-term project, a total of 80 TRU waste drums at ORNL have been retrieved from a below-grade storage vault in which they have remained untouched for about 25 years. The drums, which house material generated from past ORNL operations, are now stored and ready for eventual transfer to the Transuranic Waste Processing Center, located on Highway 95 in Oak Ridge. The Transuranic Waste Processing Center will process and ship the drums to WIPP in Carlsbad, New Mexico, for disposal. Workers lifted the drums one-by-one from the underground storage vault with a 110-ton crane over a one-week period in October 2017. Although the physical work was performed in one week, years of detailed planning preceded the fieldwork. A key obstacle needed to be overcome before the project could safely proceed. This obstacle involved the need to ensure controls were developed for the Deflagration to Detonation Transition (DDT) potential. DDT refers to a phenomenon in ignitable mixtures of a flammable gas and air (or oxygen) when a sudden transition takes place from a deflagration type of combustion to a detonation type of explosion. Basically, these drums, under certain circumstances, have a potential to detonate and overpressurize. Extensive analysis of the drums verified that detonation, while unlikely, was possible. Of the total 103 drums that were retrieved or moved in preparation for retrieval, 18 had DDT potential. Extensive security requirements were also necessary, due to the nature of the material, and this added another layer of complexity to the fieldwork. Prior to retrieving the drums from the underground storage vault, space needed to be made for them within the various above-grade facilities. Inventory and security requirements dictated what could be stored where, and the first step of the field work involved a number of drum movements in preparation for storage of the newly retrieved drums. This effort involved moving 21 drums already in the storage area to facilitate the addition of the newly retrieved ones. The retrieval project required a total of 107 critical lifts using the 110-ton crane, under 3 critical lift plans. The TRU waste storage facility is a Category 2 Nuclear Facility and is managed under an extensive Documented Safety Analysis. The TRU retrieval project was conducted in accordance with DOE Order 425.1D and included three Implementation Verification Reviews, two Management Assessments, one Readiness Assessment, and seven mock-ups in preparation for the field work. Despite being stored for 25 years, the drums were in good shape due to the integrity of the facilities where the drums were stored. Of the 80 drums that were retrieved, 12 were placed in special containers called 'overpacks' based on their content. The drums were removed safely and without incident, thanks to a lot of preparation and the efforts of a highly skilled team. Lessons learned through the DDT control development and the drum retrieval and overpacking process could be beneficial to others having to manage similar drums of TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of H-Canyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds. In the HCA pipe-jumper connections are installed remotely by using HCs. HCs inherently add to the uncertainty of a gasketed joint because a calibrated torque value cannot be applied. The gasket material is a special material made of asbestos-fiber impregnated with Teflon. This material has been used for decades and generally performs well but does leak intermittently as gaskets creep and preloaded torque is lost. Gasket types are either snap-ring (SR) or lampshade (LS). Both gasket types cover the same seating area. The SR gasket is designed to remain with the jumper when the jumper is removed leaving the nozzle faces clean of any debris. SR gaskets are initially installed when the jumper is fabricated. Changing gaskets is time consuming and the radioactive environment presents risks to personnel. When jumpers are removed LS gaskets could be used to better seal the connection to reduce down time and ALARA concerns. That is, an LS gasket would be remotely positioned over the nozzle and the HC reinstalled. Testing also included two situations not typical of plant operation. One situation was the use of the non-standard double-layered gaskets (DG), and the other situation was the use of a LS without removal of the installed SR gasket. The DG was used when the supply of LS gaskets ended, so that testing could continue. It was of interest to demonstrate this gasket’s creep response because the DG, which was two gaskets glued together, was thicker than the LS gasket and the thicker material was expected to elicit a greater creep characteristics. The second situation of using two gaskets together by installing an LS gasket without removing the installed gasket is not allowed by the ASME Codes. However, by demonstrating the creep history of such a gasket arrangement it could be considered as an option that could possibly seal a connection while significantly reducing operational down time and personnel risk. Forty tests were conducted, and the overall results demonstrate the initial applied force and how the gasket changes with time. The change in sealing force, in terms of torque, was then measured to obtain a force history as the gaskets creep. This report documents the results of those tests as well as the method used to perform the tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3013/9975 Surveillance Program Interim Summary Report

The K-Area Materials Storage (KAMS) Documented Safety Analysis (DSA) requires a surveillance program to monitor the safety performance of 3013 containers and 9975 shipping packages stored in KAMS. The SRS surveillance program [Reference 1] outlines activities for field surveillance and laboratory tests that demonstrate the packages meet the functional performance requirements described in the DSA. The SRS program also supports the complexwide Integrated Surveillance Program (ISP) [Reference 2] for 3013 containers. The purpose of this report is to provide a summary of the SRS portion of the surveillance program activities through fiscal year 2010 (FY10) and formally communicate the interpretation of these results by the Surveillance Program Authority (SPA). Surveillance for the initial 3013 container random sampling of the Innocuous bin and the Pressure bin has been completed and there has been no indication of corrosion or significant pressurization. The maximum pressure observed was less than 50 psig, which is well below the design pressure of 699 psig for the 3013 container [Reference 3]. The data collected during surveillance of these bins has been evaluated by the Materials Identification and Surveillance (MIS) Working Group and no additional surveillance is necessary for these bins at least through FY13. A decision will be made whether additional surveillance of these bins is needed during future years of storage and as additional containers are generated. Based on the data collected to date, the SPA concludes that 3013 containers in these bins can continue to be safely stored in KAMS. This year, 13 destructive examinations (DE) were performed on random samples from the Pressure & Corrosion bin. To date, DE has been completed for approximately 30% of the random samples from the Pressure & Corrosion bin. In addition, DE has been performed on 6 engineering judgment (EJ) containers, for a total of 17 to date. This includes one container that exceeded the 3013 Standard moisture limit which was opened at LANL. The container pieces and an oxide sample were sent to SRNL for examination in FY11. No significant pressurization has been observed for the Pressure & Corrosion bin containers. Relatively minor corrosion has been observed on some convenience containers and the inside of two inner containers. While the limited extent of corrosion does not jeopardize the integrity of the outer 3013 containers, it does highlight the importance of continuing to perform DE and the Shelf Life program to assure that the corrosion rate is not accelerating or changing to a different corrosion mechanism (e.g., stress corrosion cracking). Statistical sampling is currently scheduled to be completed in FY17, but there is a proposed reduction of the number of DE's per year for FY11 and beyond which may delay the completion date. Since 3013 containers are stored inside 9975 containers, surveillances of 9975 containers are performed in conjunction with 3013 container surveillances. Results of 9975 container nondestructive examinations (NDEs) and DEs indicate that the containers will provide adequate protection of the 3013 containers in K-Area storage for at least 15 years [Reference 4].

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

DVI Simulant↗

Deposition Velocity Methods For DOE Site Safety Analyses

This report documents the results of an investigation of deposition velocity methods for use in Department of Energy (DOE) Documented Safety Analysis (DSA) modeling. The project was sponsored by the National Nuclear Security Administration (NNSA) Nuclear Safety Research and Development Program and monitored by the Chief of Nuclear Safety (CNS) from the Office of the Under Secretary for Management and Performance. Based on initial scoping discussions, the primary focus of this effort was on the dry deposition of particulate matter. However, within the constraints of the project, we also explored the sensitivity of safety analysis modeling to other key input parameters (wind direction variability, atmospheric stability, release characteristics, model assumptions), examined the 95 th percentile methodology, and investigated a few aspects of a commonly-used DOE safety analysis code, MACCS2 (MELCOR Accident Consequence Code System).

54 ENVIRONMENTAL SCIENCES↗