Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Capabilities of a single scan TV-radiographic system for digital data acquisition.

A single scan TV-radiography system capable of providing analogue signals ready for A-D conversion for input to a computer has been investigated. Modulation transfer functions of both horizontal and vertical resolution have been obtained. The capability for gray scale reproduction was also investigated. The output data rate of the system is 16 KHz thereby providing compatibility to A-D converters generally available for most computers. In general, the capability of the system was found to exceed the input capabilities of available image-amplifiers and is therefore acceptable for quantitative fluoroscopic applications.

Baily, N. A.↗

Measuring Thickness-Dependent Relative Light Yield and Detection Efficiency of Scintillator Screens

Digital camera-based neutron imaging systems consisting of a neutron scintillator screen optically coupled to a digital camera are the most common digital neutron imaging system used in the neutron imaging community and are available at any state-of-the-art imaging facility world-wide. Neutron scintillator screens are the integral component of these imaging system that directly interacts with the neutron beam and dictates the neutron capture efficiency and image quality limitations of the imaging system. This work describes a novel approach for testing neutron scintillators that provides a simple and efficient way to measure relative light yield and detection efficiency over a range of scintillator thicknesses using a single scintillator screen and only a few radiographs. Additionally, two methods for correlating the screen thickness to the measured data were implemented and compared. An example 6LiF:ZnS scintillator screen with nominal thicknesses ranging from 0–300 μm was used to demonstrate this approach. The multi-thickness screen and image and data processing methods are not exclusive to neutron scintillator screens but could be applied to X-ray imaging as well. This approach has the potential to benefit the entire radiographic imaging community by offering an efficient path forward for manufacturers to develop higher-performance scintillators and for imaging facilities and service providers to determine the optimal screen parameters for their particular beam and imaging system.

42 ENGINEERING↗

Evaluation of pebble scanning strategies for fuel qualification by simple simulated radiography

Reactor designs using tristructural-isotropic (TRISO) particles in pebble fuel forms have been developed in multiple programs and are now being designed and deployed by several companies around the world. Fuel pebbles for these designs commonly contain an inner fueled zone packed with TRISO particles and a fuel-free zone on the surface of the pebble to protect the particles within. Therefore, qualification of pebbles for use in a reactor commonly requires determination that there are no TRISO particles within a given minimum distance to the pebble surface. This determination may be made non-destructively by pebble radiography, in which a series of x-ray projections of the pebble are acquired. In this work, a method to create and image representative digital pebbles was developed to allow for rapid testing of various pebble radiography strategies to evaluate their effectiveness in detecting escapee particles. Using this method, imaging strategies in two and three dimensions were tested with fixed and adaptive angular distributions. Here it was found that an adaptive two-dimensional pebble scanning strategy was the most effective for fuel pebble qualification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Digital Imaging

Digital Imaging is the computer processed numerical representation of physical images. Enhancement of images results in easier interpretation. Quantitative digital image analysis by Perceptive Scientific Instruments, locates objects within an image and measures them to extract quantitative information. Applications are CAT scanners, radiography, microscopy in medicine as well as various industrial and manufacturing uses. The PSICOM 327 performs all digital image analysis functions. It is based on Jet Propulsion Laboratory technology, is accurate and cost efficient.

Source record↗

ASIC Scoping Study Final Report

This report documents the results and findings of a one-year scoping study investigating multichannel readout application specific integrated circuits (ASICs) for interfacing to, and processing data from, silicon photomultiplier (SiPM) arrays. We document ASIC desired and required specifications for four applications supporting national security mission areas: neutron radiography, associated particle imaging, and two versions of kinematic neutron imaging cameras. While each application has a few unique requirements that stress capability, there is generally good agreement among most. Two recently developed ASIC devices were evaluated in a system-like configuration by interfacing these to scintillator crystals exposed to gamma and neutron sources. The 64-channel ORNL device delivered functional capability while meeting most mission requirements for neutron radiography. The Nalu Scientific device, a 32-channel full waveform digitizer, did not demonstrate reliable neutron / gamma separation but it is unclear if this was an ASIC issue or problems with test setup or firmware. A literature survey of other commercial and academic ASICs was undertaken to with the conclusion that existing devices do not meet all requirements.

42 ENGINEERING↗

Impact damage in filament wound composite bottles

Increasingly, composite materials are being used in advanced structural applications because of the significant weight savings they offer when compared to more traditional engineering materials. The higher cost of composites must be offset by the increased performance that results from reduced structural weight if these new materials are to be used effectively. At present, there is considerable interest in fabricating solid rocket motor cases out of composite materials, and capitalizing on the reduced structural weight to increase rocket performance. However, one of the difficulties that arises when composite materials are used is that composites can develop significant amounts of internal damage during low velocity impacts. Such low velocity impacts may be encountered in routine handling of a structural component like a rocket motor case. The ability to assess the reduction in structural integrity of composite motor cases that experience accidental impacts is essential if composite rocket motor cases are to be certified for manned flight. While experimental studies of the post-impact performance of filament wound composite motor cases haven been proven performed (2,3), scaling impact data from small specimens to full scale structures has proven difficult. If such a scaling methodology is to be achieved, an increased understanding of the damage processes which influence residual strength is required. The study described herein was part of an ongoing investigation of damage development and reduction of tensile strength in filament wound composites subjected to low velocity impacts. The present study, which focused on documenting the damage that develops in filament wound composites as a result of such impacts, included two distinct tasks. The first task was to experimentally assess impact damage in small, filament wound pressure bottles using x-ray radiography. The second task was to study the feasibility of using digital image processing techniques to assist in determining the 3-D distribution of damage from stereo x-ray pairs.

Highsmith, Alton L.↗

2022 Los Alamos National Laboratory Test and Analysis Abstracts

The abstracts included in this document are: Responsiveness, Modernization, and Radiography Test at the Centrifuge Test Facility; LANL Hostile Blast Testing Capability Development; Digital Image Correlation Measurement of B61 Center Case Fragmentation Test; and Collaborative Analysis Testing Techniques (CATT) Phase 1.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Radiographic bone densitometry

Radiographic bone densitometry for bone mass determinations in os calcis, middle phalanx of fifth digit, and patella

BONE↗

Liquid jet breakup and atomization in rocket chambers under dense spray conditions

Two advanced diagnostic techniques were established and employed in this project. The first technique involves the use of a real-time x ray radiography system along with a high-speed CCD Xybion camera and an advanced digital image processor to investigate the breakup processes of the liquid core. The focus of this part of the project is to determine the inner structure of the liquid jet and via thin sheets of laser light, with the scatters light being photographed by a Xybion electronic camera synchronized to the laser pulse. This technique, which is capable of recording the breakup event occurring within 25 nano-seconds, enables us to freeze the motions of the jet and liquid droplets. The focus of this part of the project is to determine the outer structure of the liquid jet and to discover the configuration of the surface waves, the spray pattern, and the droplet size distribution in the non-dilute region. Results obtained by these two advanced diagnostic techniques will provide the much needed database for model development and accurate prediction of engine performance. The present work also represents a breakthrough in the area of advanced diagnostics of dense sprays.

Kuo, Kenneth K.↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic fracture of glass fiber-reinforced ductile polymer matrix composites and loading rate effect

Here, the dynamic fracture of S-2 glass fiber-reinforced polymer matrix composites (FRPMCs) was investigated in this study. The matrix ductility was improved by a recently developed network topology modification technique via mixing partially reacted substructures (mPRS). The composite material was manufactured and characterized by micro-CT scanning and scanning electron microscopy (SEM). Dynamic single-edge notched bending (d-SENB) experiments were performed on the composites by using a modified split-Hopkinson pressure bar. Each specimen’s fracture process was visualized by ultrafast X-ray imaging. Such in-situ radiography enabled identifying the damage initiation below 50-micron scale and inspecting its propagation through the internal structures of opaque composites, thereby accurately quantifying the composites’ mechanical properties. Furthermore, the identical d-SENB experiments were designed and the digital image correlation (DIC) was employed to monitor the stress wave propagation on the composite specimens. The force and deflection measurements were modified and correlated to the physical damage processes. Besides, quasi-static SENB experiments were conducted to identify the loading rate effects on the composites’ fracture behaviors. The force and deflection history, bending stiffness, energy dissipation, and fracture toughness at different loading rates were quantified and compared. Finally, post-fracture analysis by micro-CT scanning and SEM provided physical observations on the variation of the fracture morphology by different loading rates.

42 ENGINEERING↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The APL image processing laboratory

The present and proposed capabilities of the Central Image Processing Laboratory, which provides a powerful resource for the advancement of programs in missile technology, space science, oceanography, and biomedical image analysis, are discussed. The use of image digitizing, digital image processing, and digital image output permits a variety of functional capabilities, including: enhancement, pseudocolor, convolution, computer output microfilm, presentation graphics, animations, transforms, geometric corrections, and feature extractions. The hardware and software of the Image Processing Laboratory, consisting of digitizing and processing equipment, software packages, and display equipment, is described. Attention is given to applications for imaging systems, map geometric correction, raster movie display of Seasat ocean data, Seasat and Skylab scenes of Nantucket Island, Space Shuttle imaging radar, differential radiography, and a computerized tomographic scan of the brain.

Jenkins, J. O.↗