Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital Infrastructure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Improved digital construction binder solution utilizing calcium aluminate additive for Infrastructure Scale Additive Manufacturing

Oak Ridge National Laboratory (ORNL) worked with Kerneos Inc., a Division of Imerys USA, Inc. to develop an improved digital construction binder using calcium aluminate additives produced by Kerneos along with locally available concrete materials. When the two-stage (2K) binder formulation was added to commercially available Portland Limestone Cement and sand to form a digital construction mortar, its strength exceeded a number of commercially available digital construction binders both at early and later ages. At the same time, the developed formulation showed precise control of setting time after addition and showed very low shrinkage making it a strong, reliable, and easily customizable alternative to fixed proprietary digital construction binders.

36 MATERIALS SCIENCE↗

Improved digital construction binder solution utilizing calcium aluminate additive for Infrastructure Scale Additive Manufacturing

Oak Ridge National Laboratory (ORNL) worked with Kerneos Inc., a Division of Imerys USA, Inc. to develop an improved digital construction binder using calcium aluminate additives produced by Kerneos along with locally available concrete materials. When the two-stage (2K) binder formulation was added to commercially available Portland Limestone Cement and sand to form a digital construction mortar, its strength exceeded a number of commercially available digital construction binders both at early and later ages. At the same time, the developed formulation showed precise control of setting time after addition and showed very low shrinkage making it a strong, reliable, and easily customizable alternative to fixed proprietary digital construction binders.

36 MATERIALS SCIENCE↗

Multilayered Network Models for Security: Enhancing System Security Engineering with Orchestration

Security engineering approaches can often focus on a particular domain—physical security, cyber security, or personnel security, for example. Yet, security systems engineering consistently faces challenges requiring socio-technical solutions to address evolving and dynamic complexity. While some drivers of this complexity stem from complex risk environments, innovative adversaries, and disruptive technologies, other drivers are endogenous and emerge from the interactions across security engineering approaches. In response, INCOSE's Systems Security Working Group identified the need to better coordinate “disparate security solutions [that] operate independently” as one of eleven key concepts in their IS21 FuSE Security Roadmap. From this perspective, this need for “security orchestration” aligns with the perspective that security is a property that emerges from interactions within complex systems. Current efforts at Sandia National Laboratories are developing a systems security engineering approach that describes high consequence facility (HCF) security as a multidomain set of interacting layers. The result is a multilayered network (MLN)-based approach that captures the interactions between infrastructure, physical components, digital components, and humans in nuclear security systems. This article will summarize the MLN-based approach to HCF security and describe two preliminary results demonstrating potential benefits from incorporating interactions across disparate security solutions. Here, leveraging the logical structure of networks, this MLN model-based approach provides an example of how security orchestration provides enhanced systems security engineering solutions.

42 ENGINEERING↗

Strengthening the Security of Operational Technology: Understanding Contemporary Bill of Materials

The evolution of cyber-physical infrastructure has made its security more challenging. The last few years have witnessed a convergence of hardware and software segments in various domains, including operational technology (OT) which is responsible for carrying out critical tasks such as monitoring and controlling power grids, nuclear plants, transportation, and emergency services. Both hardware and software encapsulate numerous open source and proprietary subcomponents, making it crucial for end-users to understand the composition of the products they are using. For example, wind turbines incorporate thousands of lines of code (software) used for the turbine's design, planning, operation, and analytics in addition to the numerous hardware subcomponents that construct it. Due to the highly complex nature of software and hardware, knowledge of the components and subcomponents is required to mitigate cyber vulnerabilities and defend against cyberattacks. There has also been a transformation from a traditional linear supply chain into a global, dynamic, diverse, and interconnected system. The digitization of the supply chain makes it easier to find and exploit vulnerabilities. Critical infrastructures (e.g., power grids, oil, natural gas, water, and wastewater) rely on OT to function, and if the OT is compromised, equipment damage and potential interruption of services could result. A significant security measure to protect OT systems from disruption is to develop a supply chain bill of materials (BoM) corresponding to the software and hardware used in OT, along with attestations amongst vendors and asset owners. A supply chain BoM is a proactive way to understand the inherent vulnerabilities in the system and mitigate them in advance of being exploited. BoMs bolster the trust placed in the digital infrastructure and enhance software supply chain security by sustaining the management of component obsolescence and compliance, along with the seclusion of unsafe segments of a specific product. Adopting BoM tools is becoming increasingly important across various government sectors, as evidenced by the recent U.S. executive order on cybersecurity (NIST 2021). This paper aims to classify BoMs based on structure, functionality, component type, and architecture. The work also discusses case studies to further highlight the benefits of BoMs. In addition, it identifies missing pieces in existing BoM implementations so that future research may identify bounds on where it could expect to make improvements and directly enable researchers to identify promising areas for exploration. Further, the authors provide valuable recommendations to tool developers, researchers, and standardizing organizations (policymakers), additionally benefitting critical infrastructure owners and government executives. This aids in paving a path for future work, thereby, providing suggestions to determine a tool for consumers that best suit their needs.

97 MATHEMATICS AND COMPUTING↗

Digital data provenance for the power grid based on a Keyless Infrastructure Security Solution

In this work a data provenance system for grid-oriented applications is presented. The proposed Keyless Infrastructure Security Solution (KISS) provides mechanisms to store and maintain digital data fingerprints that can later be used to validate and assert data provenance using a time-based, hash tree mechanism. The developed solution has been designed to satisfy the stringent requirements of the modern power grid including execution time and storage necessities. Its applicability has been tested using a lab-scale, proof-of-concept deployment that secures an energy management system against the attack sequence observed on the 2016 Ukrainian power grid cyberattack. The results demonstrate a strong potential for enabling data provenance in a wide array of applications, including speed-sensitive applications such as those found in control room environments.

Sebastian Cardenas, David J.↗

Roadmap to Automated Mobility Systems: Informing the Planning of a Sustainable, Resilient Transportation Ecosystem for Dallas/Fort Worth International Airport

The National Renewable Energy Laboratory (NREL) developed this report to provide Dallas/Fort Worth International Airport (DFW) assistance toward a vision that considers the maturation and proliferation of mobility automation, electrification, and infrastructure integrated with Internet of Things (IoT) technologies as they present themselves on the path to 2035. In planning ongoing infrastructure investments, DFW has goals to accommodate and leverage these enabling technologies toward greater sustainability and enhanced traveler and employee experiences, ensuring that infrastructure investments are fully utilized into the future. The objective of this document is to assist DFW to anticipate and envision future airport access by travelers, employees, and goods by examining existing needs and exploring opportunities enabled by technology that informs longer-term infrastructure planning. The vast infrastructure of DFW, which includes buildings, roadways, and other physical structures, as well as growing digital and energy network infrastructures, requires long-term planning and strategy to fully leverage technology advancement and avoid abandoning assets due to functional obsolescence.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Building Cybersecurity Educational Materials for Students: The Windfarm Capture-The-Flag Exercise

Securing and protecting critical infrastructure in an increasingly digital world is vital but it is all too often an afterthought. It is especially important that students become aware of internet safety and security at an early age. However, the availability of interactive and educational cybersecurity material targeted toward students is minimal in the United States. Here we show an example of interactive cyber security educational material that an educator can use in their classroom to encourage students to think about the interaction between real-world physical objects, cyber security, and information security. By putting together a “capture-the-flag” exercise, students can see in real time how hackers and cybercriminals exploit vulnerabilities and gain access information. The students try to “capture” the “flag” (i.e., information) in the wind farm by looking for oddities in the code or by taking advantage of weaknesses in everyday protocols. Students can also see how cybersecurity interacts with the power grid through the wind farm project scenario and how a hacker could cause serious problems to a critical infrastructure sector. Our goal for the project is getting students interested in cybersecurity and help them develop an awareness of how important having robust security systems is. We also hope that this project demonstrates the importance of introducing these concepts early and inspires others to create similar projects geared toward students.

97 MATHEMATICS AND COMPUTING↗

Early Fault Detection in Nuclear Systems: A Digital Engineering Approach

Nuclear energy systems present unique challenges in terms of ensuring safety, reliability, and efficiency during their design and operation. Early fault detection is critical for mitigating risks and fostering system resilience. However, current methods often fall short at identifying faults during early stages, potentially leading to costly delays and safety risks. The present work proposes a comprehensive digital engineering approach that leverages digital twins, digital threads, model-based systems engineering, artificial intelligence, and immersive extended reality to support early fault detection in nuclear systems. Through a series of case studies, we highlight specific gaps in the fault detection mechanisms of traditional nuclear design and operation processes, then demonstrate a suite of solutions we are working to implement to address these shortcomings in similar projects. Our findings suggest that a digital engineering approach to design and operation can significantly improve fault detection, ultimately leading to reductions in risk.

42 - ENGINEERING↗

Emerging Technologies for Privacy Preservation in Energy Systems

This study explores the intersection of digitalization and privacy within the energy sector, focusing on the emerging challenges and opportunities presented by integrating Distributed Energy Resources (DERs) and advanced metering infrastructure. The need for robust digital privacy measures has become crucial as the energy industry evolves towards a more decentralized, digitalized, and decarbonized future. This study delves into four cutting-edge privacy-preserving technologies—Homomorphic Encryption (HE), Secure Multiparty Computation (SMPC), Differential Privacy (DP), and Federated Learning (FL)—each offering unique solutions to safeguard consumer data by increasing digital connectivity and data exchange. Through a detailed examination of these methods, the study explains how each technology operates, its applications within the energy sector, and the specific privacy challenges it addresses. Homomorphic Encryption allows for secure computations on encrypted data, enabling data analysis without compromising privacy. Secure Multiparty Computation enables collaborative data analysis across different entities while protecting the confidentiality of the inputs. Differential Privacy introduces randomness into the assembled data set, preventing the identification of individual records in statistical databases. Lastly, Federated Learning offers a paradigm shift in data analysis, where machine learning models are trained at the edge, minimizing the centralization of sensitive data. The research underscores the significance of implementing these privacy-enhancing technologies to comply with strict data protection regulations, foster consumer trust, and enhance the security of the energy infrastructure. By providing a comprehensive overview of these methodologies and their practical implications for the energy sector, this study aims to contribute to the ongoing discourse on digital privacy, offering insights into how the energy industry can navigate the complexities of data privacy in the digital age.

Cali, Umit↗

Throughput Estimation of Data Transport Networks From Digital Twin Measurements

Digital twins of networked infrastructures, known as Virtual Infrastructure Twins (VITs), are increasingly used for software development, pre-deployment testing, and design space exploration. While VITs avoid the costs and potential disruptions associated with experiments on operational networks, their throughput measurements are typically not sufficiently accurate for performance profiling of wide-area networks that they emulate. Here, machine learning (ML) methods are developed to transform these inaccurate VIT network throughput measurements to closely match in peak and overall profile of those from a physical testbed or production network. First, a micro kernel network reflecting a physical network is utilized to collect one-time measurements on a host to support this ML transformation. Then, a generic multi-modal ML method is developed to learn a map that transforms measurements from subsequent VITs on the same host to match past, current and follow-on testbed and cloud networks. ML generalization equations are derived to establish its correctness and probabilistically guarantee its generalization accuracy. Experimental results are presented for a variety of VIT hosts with target testbed and cloud networks; they include a case study of a four-site science ecosystem wherein inaccurate convex VIT measurement profiles are transformed into accurate concave profiles of target networks.

97 MATHEMATICS AND COMPUTING↗

Cyber-Informed Engineering Guidance—Implementing CIE in Early Systems Engineering Lifecycle Stages

Traditionally, cybersecurity is not considered in the design process. Design engineers typically focus on building safety and reliability into their products and applications. Security against malicious cyber incidents is often an afterthought, resulting in deployment of security solutions during installation or operation. Unfortunately, waiting to consider cybersecurity until later in the systems engineering lifecycle often results in less effective and more expense security. Idaho National Laboratory (INL) developed the concept of Cyber-Informed Engineering (CIE) in 2015 to provide a framework that enables cybersecurity to be built into systems beginning at the conceptual design stage. In addition to ongoing research by INL, the U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response has recently developed a National CIE Strategy document for incorporating CIE into the design and operation of infrastructure systems reliant on digital monitoring or controls. This paper provides a brief review of this National CIE Strategy as well as a roadmap to historical, current, and future CIE research by INL through the U.S. DOE Office of Nuclear Energy (NE) Cybersecurity Crosscutting Technology Development Program. A near-term focus of the DOE-NE’s research and development is to extend the foundational CIE work into detailed guidance for implementation during initial systems engineering stages in nuclear digital instrumentation and control projects and to demonstrate use of the guidance in an integrated energy systems project.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

BioSecure Digital Twin: Manufacturing Innovation and Cybersecurity Resilience

U.S. national security, prosperity, economy, and well-being require secure, flexible, and resilient Biopharmaceutical Manufacturing. The COVID-19 pandemic reaffirmed that the biomedical production value-chain is vulnerable to disruption and has been under attack from sophisticated nation-state adversaries. Current cyber defenses are inadequate, and the integrity of critical production systems and processes are inherently vulnerable to cyber-attacks, human error, and supply chain disruptions. The following chapter explores how a BioSecure Digital Twin will improve U.S. manufacturing resilience and preparedness to respond to these hazards by significantly improving monitoring, integrity, security, and agility of our manufacturing infrastructure and systems. The BioSecure Digital Twin combines a scalable manufacturing framework with a robust platform for monitoring and control to increase U.S. biopharma manufacturing resilience. Then, the chapter discusses some of the inherent vulnerabilities and challenges at the nexus of health and advanced manufacturing. Next, the chapter highlights that as the Pandemic evolves, we need agility and resilience to overcome significant obstacles. This section highlights an innovative application of Cyber Informed Engineering to developing and deploying a BioSecure Digital Twin to improve the resilience and security of the biopharma industrial supply chain and production processes. Finally, the chapter concludes with a process framework to complement the Digital Twin platform, called the Biopharma (Observe, Orient, Decide, Act) OODA Loop Framework (BOLF), a four-step approach to decision-making outputs from the Digital Twin. The BOLF will help end users leverage twin technology by distilling the available information, focusing the data on context, and rapidly making the best decision while remaining cognizant of changes that can be made as more data becomes available.

99 GENERAL AND MISCELLANEOUS↗

Virtual Framework for Development and Testing of Federation Software Stack

Softwarization of networked infrastructures combined with containerization of codes promises unprecedented computing capabilities distributed across the federations of computing systems and physical instruments. The development and testing of a software stack that implements these capabilities over an expensive physical production infrastructure is not cost-effective, and in the early stages, may potentially cause service disruptions. To address these aspects, we develop the Virtual Federated Science Instrument Environment (VFSIE), a digital twin of the physical infrastructure that emulates a multi-site federation. Each federated site is emulated using containers and virtual hosts that are connected over local-area networks, and the sites, in turn, are connected over an emulated wide-area network. We describe the framework design and implementation details. We also illustrate its application by emulating a federation of four laboratories that use Jupyter Notebook for computations and the EPICS software system for instrument control.

Al Najjar, Anees↗

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus↗

Virtual Power Plant Architecture and Resilient Design

Virtual Power Plants (VPPs) represent a fundamental shift in electric grid operations, aggregating distributed energy resources (DERs) such as solar panels and battery storage to deliver utility-scale grid services traditionally provided by centralized power plants. This report examines the unique architectural, operational, and digital assurance considerations that distinguish VPPs from conventional utility infrastructure as they scale from pilot projects to mainstream deployment across the United States. While VPPs offer significant opportunities for grid modernization and enhanced flexibility, their distributed, multi-stakeholder architecture introduces distinct security challenges that differ fundamentally from traditional generation facilities. The analysis identifies risks in VPP operations, including device-level security gaps, platform vulnerabilities, and communication protocol weaknesses that create expanded attack surfaces compared to centralized power plants. Through examination of real-world incidents and emerging threat patterns, the report demonstrates how some VPPs' reliance on consumer-owned devices, public internet infrastructure, and complex vendor ecosystems require new approaches to digital assurance and operational security. The findings provide practical guidance for utilities, regulators, and aggregators to implement robust security frameworks and operational best practices essential for maintaining grid reliability as VPP deployment accelerates under the Federal Energy Regulatory Commission (FERC) Order 2222 and related regulatory initiatives.

24 - POWER TRANSMISSION AND DISTRIBUTION↗