Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Diagnostic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analysis of streaked images of x-ray self-emission in laser-driven spherical implosions

Imaging of x-ray self-emission provides a powerful in situ measurement of the spatial and temporal evolution of high-energy-density plasmas. However, interpretation of these measurements requires detailed understanding of the data-generating process. This work presents a case study in the interpretation of x-ray self-emission data for the specific application of streaked one-dimensional slit imaging of spherical laser-driven implosions. A comprehensive generative model of the streaked slit-imaging diagnostic is developed including detailed treatments of the radiation transfer, photometrics, and photostatistics associated with the measurement. The model is used to generate realistic synthetic streaked images and to analyze experimental streaked images to extract important physical quantities of interest. An example analysis of streaked images from implosion experiments on the OMEGA laser is presented, where the model developed in this work is used to constrain the trajectory and peak velocity of the implosion using Bayesian inference.

Bayesian inference

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION

Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation (Final Technical Report)

The overall objectives of this project were (1) to develop methods for the production and separation of a diagnostic and therapeutic or “theranostic” pair of radioisotopes, terbium-155 ( 155 Tb) and terbium-161 ( 161 Tb) and (2) to train graduate students and postdoctoral fellows in technologies and methods used in radionuclide production. Radionuclides can be incorporated into drugs called radiopharmaceuticals that target a specific disease (e.g., cancer). The need for theranostic radionuclides is escalating with the clinical translation of radiopharmaceuticals due to their implementation in personalized medicine, which has demonstrated enhanced patient treatments. High purity and high specific activity radionuclides are critical for theranostic agent development, for example to maintain diagnostic image quality, to minimize radiation dose to the patient, and to increase uptake in the targeted tissue (e.g., tumor), especially in the case of receptor- and antigen-targeted agents. The 155 Tb (diagnostic) and 161 Tb (therapeutic) radioisotopes that were generated through this project are a theranostic pair with demonstrated potential for the development and translation into individualized, targeted, and dosimetry-driven radiotherapies. However, the development of such radiotherapies has been hindered by the lack of a routine and reliable supply of these isotopes in the United States. Methods for the production, separation, and supply of 155 Tb and 161 Tb were investigated and developed in this project. Further, the strong emphasis throughout the project on the training of graduate students and postdoctoral fellows has helped to ensure and enhance the nuclear science workforce through the training of the next generation of highly qualified scientists in nuclear and radiochemistry. This grant also continued a collaboration between scientists at the University of Washington (UW), the University of Missouri (MU) and Brookhaven National Laboratory (BNL). All three institutions were involved in the project, but to different degrees on the various tasks through which the overall objectives were met.

07 ISOTOPE AND RADIATION SOURCES

Evaluation of Human Research Facility Ultrasound With the ISS Video System

Most medical equipment on the International Space Station (ISS) is manifested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical situations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-operator during an exam to facilitate the diagnosis in a timely fashion. In this document, we strove to verify that the HRF ultrasound video output is compatible with the ISS video system, identify ISS video system field rates and resolutions that are acceptable for varying clinical scenaiios, and evaluate the HRF ultrasound video with a commercial, off-the-shelf video converter, and compare it with the ISS video system.

Melton, Shannon

Lunar Surface Reference Missions: A Description of Human and Robotic Surface Activities

Most medical equipment to the International Space Station (ISS) is manisfested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical siruations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-opertor during an exam to facilitate the diagnosis in a timely fashion.

Duke, Michael B.

A Specialized Ultrasound Protocol for NASA's Renal Stone Surveillance and Clinical Practice

INTRODUCTION Ample evidence exists on the effectiveness of ultrasound in the diagnosis of kidney stones. However, terrestrial practice is mostly concerned with diagnosis of clinically significant urolithiasis. Adapting this non-irradiating, low-cost imaging modality for the asymptomatic astronaut population offers high-sensitivity screening and limits their career radiation dose. METHODS NASA developed a novel ultrasound-based detection and surveillance protocol to identify, categorize, and monitor mineralized renal material (MRM) in astronauts. The term MRM was developed to denote abnormal, presumably calcified, focal material of unknown clinical significance in the kidneys. Sonographic criteria for MRMs include measurable echogenic foci, their detectability in multiple, designated imaging plains, posterior shadowing, and “twinkle” pattern visualized in Color Doppler and/or demonstrated in Spectral Doppler modes. The mere discovery of an MRM does not trigger further imaging or intervention, unless the affected crewmember is mission-assigned, or the MRM meets actionable criteria based on size, location, and sonographic characteristics. If the threshold is met, the crew surgeon is notified, and additional diagnostic imaging and urology consultation are considered. RESULTS In total, 73 individuals have been scanned using our specialized methods, 60 have had more than one study done. As of April 2023, 282 total studies have been performed. So far, over 30 pairs of pre-and postflight studies have been obtained, and the findings are presented elsewhere in this panel. DISCUSSION A surveillance program was initiated nine years ago to screen asymptomatic members of the astronaut corps for renal calcifications, from their initial hiring, through their mission timeframes, and throughout their career. The goal is to reduce the probability that an astronaut will fly with a renal stone that may become symptomatic. This also gives NASA the information it needs to improve screening criteria for future long-duration crewed missions.

H Lyons

Acoustic Holography of the Solar Convection Zone with SOHO-MDI Observations

The original grant with the title stated above was NAG5-10984, awarded to the Solar Physics Research Corporation (SPRC) in July, 2001, and was to be a three-year project. The basic theme of the project was the development and application of computational seismic holography for imaging, diagnostics, and monitoring of magnetic anomalies beneath active regions, in the deep solar interior, and on the Sun's far surface. The project was roughly separated into the following five tasks: (1) A holographic survey of active regions. (2) p-Mode absorption diagnostics of magnetic regions. (3) Acoustic modeling of the shallow subphotospheres of active regions and the quiet-Sun supergranulation based on phase-correlation seismic holography. (4) Seismic holography of the deep convection zone. (5) Improvements in holographic imaging of the far surface of the Sun. Following the death of Karen Harvey, President of SPRC, during the first year, the grant was transferred to Northwest Research Associates as NAG5-12901. Substantial but progress had been made on most of the above tasks in the first year under NAG5-10984, but none were completed. This work was continued under NAG5-12901.

Lindsey, Charles

Infrared surface imaging as a flowfield diagnostic tool

An infrared imaging system supported by a dedicated image processing system was evaluated as a diagnostic tool for aerodynamic research. Results are reported characterizing the system's capability for performing a variety of experimental investigations, such as temperature transients, air velocity distributions, capture of vortices, boundary layer flows, and separated flows over a flat plate with a two-dimensional rearward-facing step.

Gartenberg, Ehud

Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

NASA Discipline Life Sciences Technologies

Comparison of MPEG digital video with super VHS tape for diagnostic echocardiographic readings

BACKGROUND: Digital recording of echocardiographic studies is on the clinical horizon. However, full digital capture of complete echocardiographic studies in traditional video format is impractical, given current storage capacity and network bandwidth. To overcome these constraints, we evaluated the diagnostic image quality of digital video by using MPEG (Motion Picture Experts Group) compression. METHODS AND RESULTS: Fifty-eight complete, consecutive studies were recorded simultaneously with the use of MPEG-1 and sVHS videotape. Each matched MPEG and sVHS study pair was reviewed by two from a total of six readers, and findings were recorded with the use of a detailed, computerized reporting tool. Intrareader and interreader discrepancies were characterized as major or minor and analyzed in total and for specific subgroups of findings (left and right ventricular parameters, valvular insufficiency, and left ventricular regional wall motion). Intrareader discrepancies were reviewed by a consensus panel for agreement with either MPEG or sVHS findings. There was an exact concordance between MPEG and sVHS readings in 83% of findings. The majority of discrepancies were minor, with major discrepancies in only 2.7% of findings. There was no difference in the rate of consensus panel agreement with MPEG or sVHS for instances of intrareader discrepancy, either in total or for any subgroup of findings. Interreader discrepancy rates were nearly identical for both MPEG and sVHS. CONCLUSIONS: MPEG-1 digital video is equivalent to sVHS videotape for diagnostic echocardiography. MPEG increases the range of practical options for digital echocardiography and offers, for the first time, the advantages of digital recording in a familiar video format.

Non-NASA Center

Rapid discovery and evolution of nanosensors containing fluorogenic amino acids

Binding-activated optical sensors are powerful tools for imaging, diagnostics, and biomolecular sensing. However, biosensor discovery is slow and requires tedious steps in rational design, screening, and characterization. Here we report on a platform that streamlines biosensor discovery and unlocks directed nanosensor evolution through genetically encodable fluorogenic amino acids (FgAAs). Building on the classical knowledge-based semisynthetic approach, we engineer ~15 kDa nanosensors that recognize specific proteins, peptides, and small molecules with up to 100-fold fluorescence increases and subsecond kinetics, allowing real-time and wash-free target sensing and live-cell bioimaging. An optimized genetic code expansion chemistry with FgAAs further enables rapid (~3 h) ribosomal nanosensor discovery via the cell-free translation of hundreds of candidates in parallel and directed nanosensor evolution with improved variant-specific sensitivities (up to ~250-fold) for SARS-CoV-2 antigens. Altogether, this platform could accelerate the discovery of fluorogenic nanosensors and pave the way to modify proteins with other non-standard functionalities for diverse applications.

Biosensors

A high speed imaging system for nuclear diagnostics

A high speed imaging system based on state-of-the-art photosensor arrays was designed for use in nuclear diagnostics. The system is comprised of a front end rapid scan solid state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in an uphole trailer. The downhole camera takes a snapshot of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to a computational facility. In the talk, the impetus for such a system as well as its operation was discussed, along with systems under development which incorporate higher data rates and more resolution.

Eyer, H. H.

An experimental and computational study of thin-layer Rayleigh–Taylor instability development during deceleration with and without an externally applied magnetic field

The importance of mitigating the Rayleigh–Taylor instability (RTI) in inertial confinement fusion (ICF) is critical to successfully achieve high gain fusion yield. Consequently, understanding the seed mechanisms of RTI and the potential evolution of RTI in ICF relevant conditions is crucial. Single feature perturbations consistently demonstrate non-linear RTI evolution, for which an experimental platform on OMEGA-EP is developed. Manufacturing defects introduced into the target design require exploration of unanticipated changes to RTI development and an identification of targets that will still render quantifiable physics results. Consequently, it is presented that the inherent 3D nature of experimental targets necessitates 3D modeling for accurate design work and predictive modeling of experimental targets, especially when high resolution imaging diagnostics, like Fresnel Zone Plates, are utilized. A study of the morphology of the RTI evolution due to changing initial conditions and the presence of an externally applied magnetic field are also explored. Experimental data show thin-layer RTI morphology comparable to resistive magneto hydrodynamic 3D results. A discussion on the impacts of an externally applied magnetic field makes the case for continued efforts to observe a magnetic field's impact on RTI morphology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature

Electric fields and stationary drift flows in the island divertor SOL of Wendelstein 7-X

Abstract In the island divertor scrape-off layer (SOL) of the Wendelstein 7-X stellarator, 2D-resolved Langmuir probe measurements uncover a complex spatial structure of electron temperature, density, and floating potential. Depending on details of magnetic island size and position, significant poloidal gradients and non-monotonic radial profiles are observed. The resulting electric fields imply the presence of sheared stationary drift flows with poloidal velocities of a few km/s, with flow channels as narrow as one cm. Such flows are observed with a gas puff imaging diagnostic in qualitative agreement with the probe results and imply a significant transport channel in the SOL. The 2D distribution of plasma parameters is intricately associated to the unique magnetic structure of the island divertor SOL and highlights the necessity for more accurate magnetic field reconstructions.

Killer, Carsten (ORCID:0000000177473066)

Photonuclear cross sections for the 197 Au ⁢(𝛾, 𝑝⁢𝑛)⁢ 195⁢𝑚 Pt reaction near threshold

Platinum radioisotopes are of growing interest for targeted cancer therapy and diagnostic imaging because their decay delivers highly localized radiation doses in tissue, herewith enabling precise DNA damage through Auger-electron emission. Developing production technologies that provide platinum isotopes with high specific activity is essential in radioisotope therapy. Photonuclear reactions on stable nuclei offer a viable accelerator-based route for isotope production when supported by reliable cross-section data. We report photonuclear cross-section measurements for the 197 Au(γ, pn) 195m Pt reaction at incident γ-ray energies of 27, 29, and 31 MeV using the activation method. The measurements were performed by irradiating a stack of concentric-ring gold targets with a quasi-monoenergetic γ-ray beam provided by the High Intensity Gamma-ray Source (HI γS). The induced 195m Pt activity was quantified using off-line γ-ray spectroscopy. These data provide the first experimental constraints on the 197 Au(γ, pn) 195m Pt cross section in the near-threshold region. Furthermore, the comparison of the measured excitation function to PHITS and TALYS calculations indicates that the reaction becomes measurable only near 30 MeV and that substantially higher bremsstrahlung end-point energies are required for practically meaningful production.

190 ≤ A ≤ 219

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]

Case Report: Differential diagnosis of hematuria in the emergency department: emphasizing double J stent-inferior vena cava fistula

Introduction Hematuria, a common clinical indicator of genitourinary tract pathology, arises from diverse etiologies including calculi, infections, malignancies, trauma, and iatrogenic causes. Initial evaluation requires hemodynamic assessment, identification of underlying causes, and urinary drainage optimization. This report highlights a rare case of iatrogenic hematuria secondary to double-J stent migration into the inferior vena cava. Case presentation A Chinese male presented with acute left flank pain and gross hematuria persisting for 4 h. Diagnostic imaging revealed a left ureteral stone, prompting double-J stent placement at a local hospital. Despite intervention, hematuria worsened, necessitating abdominal CT. Imaging identified proximal migration of the left double-J stent into the inferior vena cava, with no evidence of vascular injury. Due to concerns regarding inadequate drainage and infection risk, conservative management without catheter clamping was initiated prior to referral. Definitive treatment involved ureteroscopic stent removal under direct visualization at our institution, resulting in rapid symptom resolution. Conclusion This case emphasizes three critical clinical insights: (1) Persistent postoperative hematuria warrants consideration of iatrogenic causes, particularly following urologic device placement. (2) Imaging modalities, especially CT, are indispensable for detecting atypical stent migration. (3) Comprehensive history-taking must include prior urologic interventions to guide differential diagnosis. While double-J stent migration into major vessels remains exceptionally rare, its recognition prevents delayed management of potentially life-threatening complications. Clinicians should maintain heightened vigilance for device-related hematuria in patients with refractory symptoms post-procedurally, ensuring prompt imaging evaluation and multidisciplinary intervention when indicated.

Qi, Wenqi