Compact imaging spectrometer for induced emissions

On the basis of spectral measurements made from the Space Shuttle and on models of the possible Space Station external environment, it appears likely that, even at the planned altitudes of Space Station, photon emissions will be induced. These emissions will occur to some degree throughout the ultraviolet-visible-infrared spectrum. The emissions arise from a combination of processes including gas phase collisions between relatively energetic ambient and surface emitted or re-emitted atoms or molecules, where the surface raises some species to excited energy states. At the present time it is not possible to model these processes or the anticipated intensity levels with any accuracy, as a number of fundamental parameters needed for such calculations are still poorly known or unknown. However, it is possible that certain spectral line and band features will exceed the desired goal that concomitant emissions not exceed the natural zodiacal background. Also, in the near infrared and infrared, it appears that this level will be exceeded to a significant degree. Therefore it will be necessary to monitor emission levels in the vicinity of Space Station, both in order to establish the levels and to better model the environment. A small spectrometer is briefly described which is suitable for monitoring the spectrum from 1200 A to less than or equal to 12,000 A. The instrument uses focal plane array detectors to image this full spectral range simultaneously. The spectral resolution is 4 to 12 A, depending on the portion of the wavelength range.

Torr, Douglas G.↗

A compact imaging spectrometer for studies of space vehicle induced environment emissions

On the basis of spectral measurements made from the Space Shuttle and on models of the possible Space Station external environment, it appears likely that, even at the planned altitudes of Space Station, photon emissions will be induced. These emissions will occur to some degree throughout the UV-visible-IR spectrum. The emissions arise from a combination of processes including gas phase collisions between relatively energetic ambient and surface emitted or re-emitted atoms or molecules, where the surface raises some species to excited energy states. At present it is not possible to model these processes or the anticipated intensity levels with accuracy, as a number of fundamental parameters needed for such calculations are still poorly known or unknown. However, it is possible that certain spectral line and band features will exceed the desired goal that contaminant emissions not exceed the natural zodiacal background. However, in the near infrared and infrared, it appears that this level will be exceeded to a significant degree. Therefore it will be necessary to monitor emission levels in the vicinity of Space Station, both in order to establish the levels and to better model the environment. In this note, we briefly describe a small spectrometer that is suitable for monitoring the spectrum from 1200A to less than or approximately 12,000A. This instrument uses focal plane array detectors to image this full spectral range simultaneously. The spectral resolution is 4 to 12A, depending on the portion of the wavelength range.

Torr, Marsha R.↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

The Roman View of Strong Gravitational Lenses

Galaxy–galaxy strong gravitational lenses can constrain dark matter models and the Lambda cold dark matter cosmological paradigm at subgalactic scales. Currently, there is a dearth of images of these rare systems with high signal-to-noise ratio (SNR) and angular resolution. The Nancy Grace Roman Space Telescope (hereafter Roman), scheduled for launch in late 2026, will play a transformative role in strong-lensing science with its planned wide-field surveys. With its remarkable 0.281 square degree field of view and diffraction-limited angular resolution of ~0$^{''}_.$1, Roman is uniquely suited to characterizing dark matter substructure from a robust population of strong lenses. We present a yield simulation of detectable strong lenses in Roman’s planned High Latitude Wide Area Survey (HLWAS). We simulate a population of galaxy–galaxy strong lenses across cosmic time with cold dark matter subhalo populations, select those detectable in the HLWAS, and generate simulated images accounting for realistic Wide Field Instrument detector effects. For a fiducial case of single 146 s exposures, we predict around 160,000 detectable strong lenses in the HLWAS, of which about 500 will have sufficient SNR to be amenable to detailed substructure characterization. We investigate the effect of variation of the point-spread function across Roman’s field of view on detecting individual subhalos and the suppression of the subhalo mass function at low masses. Our simulation products are available to support strong-lens science with Roman, such as training neural networks and validating dark matter substructure analysis pipelines.

79 ASTRONOMY AND ASTROPHYSICS↗

Global Patterns of Lightning Properties Derived by OTD and LIS

The satellite instruments Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) provide unique empirical data about the frequency of lightning flashes around the globe (OTD), and the tropics (LIS), which 5 has been used before to compile a well received global climatology of flash rate densities. Here we present a statistical analysis of various additional lightning properties derived from OTD/LIS, i.e. the number of so-called "events" and "groups" per flash, as well as 10 the mean flash duration, footprint and radiance. These normalized quantities, which can be associated with the flash "strength", show consistent spatial patterns; most strikingly, oceanic flashes show higher values than continental flashes for all properties. Over land, regions with high (Eastern US) 15 and low (India) flash strength can be clearly identified. We discuss possible causes and implications of the observed regional differences. Although a direct quantitative interpretation of the investigated flash properties is difficult, the observed spatial patterns provide valuable information for the 20 interpretation and application of climatological flash rates. Due to the systematic regional variations of physical flash characteristics, viewing conditions, and/or measurement sensitivities, parametrisations of lightning NOx based on total flash rate densities alone are probably affected by regional biases.

Beirle, Steffen↗

Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the Tev Region With Calet on the International Space Station

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10 5 ), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from −3.15 to −3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

O. Adriani↗

Maintaining the Continuity of the Global Climate Data Record of Lightning from Space

Lightning is a natural hazard, an indicator of changes in convective storm behavior across multiple spatial and temporal scales, and a major influence on climate-affecting chemicals such as ozone and methane. Lightning also has substantial impacts on the near-space environment. As such, the World Meteorological Organization (WMO) has designated lightning as an Essential Climate Variable (ECV); that is, a measurement that is really important for understanding Earth’s climate. Spaceborne lightning observations are the gold standard for measuring global lightning, as the detection efficiency is more spatially uniform compared to ground-based lightning measurements. In addition, spaceborne is the only practical method for measuring total lightning (i.e., both intracloud and cloud-to-ground) at the global scale, as ground-based networks have limited ability to detect intracloud lightning at long distances (e.g., over oceans, far from land-based sensors). Since 1995, with only a two-year gap (2015-2017), lightning has been observed globally using a combination of Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) instruments. However, the year 2023 is the planned end for the International Space Station (ISS) LIS mission, and there is no designated low-Earth orbit (LEO) successor yet identified. Since 2017, geostationary (GEO) observations of lightning have become increasingly available. These include the U.S. Geostationary Lightning Mappers (GLMs), China’s Lightning Mapping Imager (LMI), and Europe’s Lightning Imager (LI). While GEO provides continuous, quasi-hemispheric coverage of lightning and thunderstorms, there are current gaps preventing global coverage, particularly in portions of Asia and the western Pacific, as well as high-latitude regions. Moreover, integration of the GEO constellation into a Climate Data Record (CDR) of lightning is a major challenge only recently begun to be addressed by the WMO. Furthermore, recent work has demonstrated some deficiencies in the global record of lightning from space. For example, small lightning flashes are very common in severe weather, but are difficult to observe using the present set of spaceborne lightning imagers. Moreover, some types of lightning are best observed using frequencies other than the commonly used near-infrared (777-nm), including ultraviolet and the radio spectrum. Finally, it is not possible to assess the vertical distribution of lightning globally, even though this measurement is highly relevant to thunderstorm behavior as well as lightning’s effects on greenhouse gases and the near-space environment. This presentation will provide a current assessment of lightning measurements from space, will identify significant current and future gaps in these observations, and will evaluate potential solutions for improving the overall CDR of global lightning.

Timothy Lang↗

Instrumentation for optical remote sensing from space; Proceedings of the Meeting, Cannes, France, November 27-29, 1985

Papers are presented on such topics as the development of the Imaging Spectrometer for Shuttle and space platform applications; the in-flight calibration of pushbroom remote sensing instruments for the SPOT program; buttable detector arrays for 1.55-1.7 micron imaging; the design of the Improved Stratospheric and Mesospheric Sounder on the Upper Atmosphere Research Satellite; and SAGE II design and in-orbit performance. Consideration is also given to the Shuttle Imaging Radar-B/C instruments; the Venus Radar Mapper multimode radar system design; various ISO instruments (ISOCAM, ISOPHOT, and SWS and LWS); and instrumentation for the Space Infrared Telescope Facility.

Seeley, John S.↗

The measurement of global scale surface dynamics

The SCADM mission implicitly contains a requirement for a fundamentally new type of satellite instrument: a very sensitive (approximately 1 m s/1) imaging velocity detector. This is needed to measure global oscillations and global circulation patterns, but the sensitivity requirement is so severe that it has not yet been met even with ground based instruments. In this presentation, the various possible sources of noise and other errors in such a device are considered, and the more detailed instrumental requirements are developed. This leads to the conceptual design of a velocitygraph that appears to achieve the necessary sensitivity and imaging capability within a resonable weight and volume.

Frazier, E. N.↗

Maturing CCD Photon-Counting Technology for Space Flight

This paper discusses charge blooming and starlight saturation - two potential technical problems - when using an Electron Multiplying Charge Coupled Device (EMCCD) type detector in a high-contrast instrument for imaging exoplanets. These problems especially affect an interferometric type coronagraph - coronagraphs that do not use a mask to physically block starlight in the science channel of the instrument. These problems are presented using images taken with a commercial Princeton Instrument EMCCD camera in the Goddard Space Flight Center's (GSFC), Interferometric Coronagraph facility. In addition, this paper discusses techniques to overcome such problems. This paper also discusses the development and architecture of a Field Programmable Gate Array and Digital-to-Analog Converter based shaped clock controller for a photon-counting EMCCD camera. The discussion contained here will inform high-contrast imaging groups in their work with EMCCD detectors.

Mallik, Udayan↗

Application of MCM image construction to IRAS comet observations

There is a wealth of IRAS comet data, obtained in both the survey and pointed observations modes. However, these measurements have remained largely untouched due to difficulties in removing instrumental effects from the data. We have developed a version of the Maximum Correlation Method for Image Construction algorithm (MCM) which operates in the moving coordinate system of the comet and properly treats both real cometary motion and apparent motion due to spacecraft parallax. This algorithm has been implemented on a 486/33 PC in FORTRAN and IDL codes. Preprocessing of the IRAS CRDD includes baseline removal, deglitching, and removal of long tails due to dielectric time constants of the detectors. The resulting images are virtually free from instrumental effects and have the highest possible spatial resolution consistent with the data sampling. We present examples of high resolution IRAS images constructed from survey observations of Comets P/Tempel 1 and P/Tempel 2, and pointed observations of IRAS-Araki-Alcock.

Schlapfer, Martin F.↗

The 2.5-12 micrometers spectrum of comet Halley from the IKS-VEGA experiment

The infrared instrument IKS flown on board the VEGA space probes was designed for the detection of emission bands of parent molecules, and for a measurement of the size and temperature of the thermal emitting nuclear region. The instrument had three channels with cooled detectors: an "imaging channel" designed to modulate the signal of the nucleus and two spectroscopic channels operating at 2.5-5 and 6-12 micrometers, respectively, equipped with circular variable filters of resolving power approximately 50. This paper presents and discusses the results from the spectral channels. On VEGA 1, usable spectra were obtained at distances D from the comet nucleus ranging from 250,000 to 40,000 km corresponding to fields of view 4000 and 700 km in diameter, respectively. The important internal background signal caused by the instrument itself, which could not be cooled, had to be eliminated. Since no sky chopping was performed, we obtain difference spectra between the current spectrum and a reference spectrum with little or no cometary signal taken at the beginning of the observing sequence (D approximately 200,000 km). Final discrimination between cometary signal and instrumental background is achieved using their different time evolution, since the instrumental background is proportional to the slow temperature drift of the instrument, and the cometary signal due to parent molecules or dust grains is expected to vary in first order as D-1. The 2.5-5 micrometers IKS spectra definitely show strong narrow signals at 2.7 and 4.25 micrometers, attributed to the nu 3 vibrational bands of H2O and CO2, respectively, and a broader signal in the region 3.2-3.5 micrometers, which may be attributed to CH-bearing molecules. All these signals present the expected D-1 intensity variation. Weaker emission features at 3.6 and 4.7 micrometers could correspond to the nu 1 and nu 5 bands of H2CO and the (1 - 0) band of CO, respectively. Molecular production rates are derived from the observed emissions, assuming that they are due to resonance fluorescence excited by the Sun's infrared radiation. For the strong bands of H2O and CO2, the rovibrational lines are optically thick, and radiative transfer is taken into account. We derive production rates, at the moment of the VEGA 1 flyby, of approximately 10(30) sec-1 for H2O, approximately 2.7 x 10(28) sec-1 for CO2, approximately 5 x 10(28) sec-1 for CO, and 4 x 10(28) sec-1 for H2CO, if attributions to CO and H2CO are correct. The production rate of carbon atoms in CH-bearing molecules is approximately 9 x 10(29) sec-1 assuming fluorescence of molecules in the gas phase, but could be much less if the 3.2-3.5 micrometers emission is attributed to C-H stretch in polycyclic aromatic hydrocarbons or small organic grains. In addition, marginal features are present at 4.85 and 4.45 micrometers, tentatively attributed to OCS and molecules with the CN group, respectively. Broad absorption at 2.8-3.0 micrometers, as well as a narrow emission at 3.15 micrometers, which follow well the D-1 intensity variation, might be due to water ice. Emission at 2.8 micrometers is also possibly present, and might be due to OH created in vibrationally excited states after water photodissociation. The 6-12 micrometers spectrum does not show any molecular emission, nor emission in the 7.5-micrometers region. The spectrum is dominated by silicate emission showing a double structure with maxima at 9.0 and 11.2 micrometers, which suggests the presence of olivine.

NASA Discipline Number 52-10↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗