Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Integrating 128 element InSb array - Recent results

There has been a continuing evolution toward larger arrays of infrared detectors, and the technology base derived from the Galileo Near Infrared Mapping Spectrometer (NIMS) has been expanded to linear arrays including from 128 to 512 elements. This advance is based on the commercial availability of high-quality InSb photodiodes and 128/256 element FET switch MUX's (multiplexing elements). The present investigation is concerned with an experimental 128-element linear imager using InSb detectors and silicon MUX for readout. Attention is given to detector array electrical characteristics, the detector readout architecture, noise, and special effects.

Bailey, G.↗

Readout system for radiation detector

Improved electrical circuit determines the amount of light detected by a photomultiplier tube when its output signal is in the dark-current range of the tube. The low-intensity light to which the tube responds arises from a thermo-luminescent ionized dosimeter.

Baker, B. R.↗

Spaceflight KID Readout Electronics Development for PRIMA

We present the design and testing of spaceflight multiplexing kinetic inductance detector (KID) readout electronics for the PRobe far-Infrared Mission for Astrophysics (PRIMA). PRIMA is a mission proposed to the 2023 NASA Astrophysics Probe Explorer (APEX) Announcement of Opportunity that will answer fundamental questions about the formation of planetary systems, as well as the formation and evolution of stars, supermassive black holes, and dust over cosmic time. The readout electronics for PRIMA must be compatible with operation at Earth-Sun L2 and capable of multiplexing more than 1000 detectors over 2 GHz bandwidth while consuming around 30 W per readout chain. The electronics must also be capable of switching between the two instruments, which have different readout bands,: the hyperspectral imager (PRIMAger, 2.5-5.0 GHz) and the spectrometer (FIRESS, 0.4-2.4 GHz). We present the driving requirements, design, and measured performance of a laboratory brassboard system.

Sumit Dahal↗

Method for the Absolute Calibration of the Location and Orientation of Large-Format Detectors Using Laser Radar

A method of mapping pixel locations of a detector array includes measuring a location on the detector array, initiating a frame readout of the detector array, measuring a location of one or more metrology targets on the detector array, analyzing the frame readout to identify a pixel at the location on the detector array, and defining a location of the identified pixel with respect to the location of the one or more metrology targets. Subsequent measurement of the metrology targets alone by another metrology system allows one to infer the six degree of freedom alignment of the detector array in space.

Coulter, Phillip↗

Improved low frequency stability of bolometric detectors

An ac bridge readout system has been developed that greatly improves the low-frequency stability of bolometric detectors. The readout can be implemented with a simple circuit appropriate for use in space applications. A matched pair of detectors was used in the readout to achieve system noise within a factor of two of the fundamental noise limit of the detectors at frequencies as low as 10 mHz. The low-frequency stability of the readout system allows slower, more sensitive detectors to be used in many applications, and it facilitates observing strategies that are well suited to spaceborne observations.

Wilbanks, T.↗

IRAC test report. Gallium doped silicon band 2: Read noise and dark current

A direct readout infrared detector array, a candidate for the Space Infrared Telescope Facility (SIRTF) Infrared Array Camera (IRAC), has been tested. The array has a detector surface of gallium doped silicon, bump bonded to a 58x62 pixel MOSFET multiplexer on a separate chip. Although this chip and system do not meet all the SIRTF requirements, the critically important read noise is within a factor of 3 of the requirement. Significant accomplishments of this study include: (1) development of a low noise correlated double sampling readout system with a readout noise of 127 to 164 electrons (based on the detector integrator capacitance of 0.1 pF); (2) measurement of the readout noise of the detector itself, ranging from 123 to 214 electrons with bias only (best to worst pixel), and 256 to 424 electrons with full clocking in normal operation at 5.4 K where dark current is small. Thirty percent smaller read noises are obtained at a temperature of 15K; (3) measurement of the detector response versus integration time, showing significant nonlinear behavior for large signals, well below the saturation level; and (4) development of a custom computer interface and suitable software for collection, analysis and display of data.

Lamb, Gerald↗

Electron bombardment charge-coupled device /CCD/ detectors for the vacuum ultraviolet

Development work is underway at Princeton and NRL on electronic-readout imaging detectors for the VUV which are based on electron-bombardment CCD arrays and opaque alkali-halide photocathodes. These detectors provide single-photoelectron detection capability and wide dynamic range combined with almost the maximum possible quantum efficiency (in excess of 50% in the wavelength range below 1300 A). The Princeton work is based on an oblique-focusing electron optical configuration, while the NRL program is based on a Schmidt optical system with opaque photocathode. Results of preliminary tests at Princeton and overall system concepts for the Princeton and NRL cameras are discussed, and applications to possible space astronomy studies are examined.

Lowrance, J. L.↗

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

Wollack, Edward↗

Superconducting kinetic inductance photon detectors.

We are investigating a novel superconducting detector and readout method that could lead to photon counting, energy resolving focal plane arrays. This concept is intrinsically different from STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution in the ptical/UV/X-ray bands. The readout uses the monotonic relation between the kinetic surface inductance L***subs***, of a superconductor and the density of quasiparticles n, which holds even at temperatures far below T***subc***. This allows a sensitive readout of the number of excess quasiparticles in the detector by monitoring the transmission phase of a resonant circuit. The most intriguing aspect of this concept is that passive frequency multiplexing could be used to read out ~ l0***super4*** detectors with a single HEMT amplifier. Single x-ray events have been observed in prototype detectors.

kinetic↗

Extension of the energy range accessible with a TES using bath temperature variations

The energy range of transition-edge sensor (TES) X-ray microcalorimeters with a multiplexed readout depends upon the width and shape of the TES superconducting transition, and also on the dynamic range of the readout. In many detector systems, the multiplexed readout slew rate capability will be the limiting factor for the energy range. In these cases, if we are willing to accept some energy resolution degradation, we can significantly extend the energy range by increasing the bath temperature of operation, essentially creating a second “extended energy range” mode of operation. For example, if we require the very highest energy resolution up to 7 keV, and wish to optimize the design up to this energy, for some measurements it could be very beneficial to have a mode where we can extend the energy range to 15–20 keV even if some energy resolution is sacrificed. In this paper, we explore the trade-off between dynamic range and energy resolution from changing the bath temperature of the TES. We present measurements of TES resolution and slew rate as a function of bath temperature and compare to numerical simulations.

S Beaumont↗

RF Single Electron Transistor Readout Amplifiers for Superconducting Astronomical Detectors for X-Ray to Sub-mm Wavelengths

We report progress on using a new type of amplifier, the Radio-Frequency Single-Electron Transistor (RF-SET), to develop multi-channel sensor readout systems for fast and sensitive readout of high impedance cryogenic photodetectors such as Superconducting Tunnel Junctions and Single Quasiparticle Photon Counters. Although cryogenic, these detectors are desirable because of capabilities not other-wise attainable. However, high impedances and low output levels make low-noise, high-speed readouts challenging, and large format arrays would be facilitated by compact, low-power, on-chip integrated amplifiers. Well-suited for this application are RF-SETs, very high performance electrometers which use an rf readout technique to provide 100 MHz bandwidth. Small size, low power, and cryogenic operation allow direct integration with detectors, and using multiple rf carrier frequencies permits simultaneous readout of 20-50 amplifiers with a common electrical connection. We describe both the first 2-channel demonstration of this wavelength division multiplexing technique for RF-SETs, and Charge-Locked-Loop operation with 100 kHz of closed-loop bandwidth.

Stevenson, Thomas↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for X-ray astrophysics

Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including >200 pixels, of:1.95 eV for Ti-Ka(4.5 keV), 1.97eV for Mn-Ka(5.9 keV), 2.16 eV for Co-Kα(6.9 keV),2.33 eV for Cu-Kα(8 keV), 3.26 eV for Br-Kα(11.9 keV). The 1 sigma statistical errorsare£0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

S J Smith↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

Development of a Cryogen-Free Continuous ADR for the Constellation-X Mission

Constellation-X is a multi-satellite x-ray astronomy mission presently being planned for launch in the 2010 time frame. Each of 4 identical satellites will contain a telescope and instruments for imaging and spectroscopic analysis of both hard and soft x-rays. The X- ray Microcalorimeter Spectrometer (XMS) instrument will use arrays of microcalorimeters to detect X-rays with energies from 0.2 to 6 keV. The technologies under development for this instrument include Transition-Edge Sensors (TES) with multiplexed SQUID readouts and NTD-Ge detectors with JFET readouts. Both will be operated at temperatures in the 50-60 mK range and both have a projected cooling power requirement of approximately 5 microwatts. In addition, in order to meet the lifetime requirement of 6 years (with a goal of 10 years), a mechanical cryocooler will be used to provide a heat sink for the low temperature cooler. The required performance is 20 mW at 6 K, with a goal of 4 K operation. In this paper we present the development status of an adiabatic demagnetization refigerator (ADR) that meets the cooling requirements of the X M S instrument. At present we have demonstrated a 4-stage ADR that operates continuously at 50 mK using a 4.2 K helium bath as a heat sink. The cooling power is 21 microwatts at 100 mK and 6 microwatts at 50 mK. Its efficiency when operating at 50 mK is 1 1 % of Carnot (accounting for all dissipation at 4.2 K and below, but not including power dissipation in the room temperature electronics), but this is expected to rise to 25% in the next generation system in which active gas-gap heat switches are replaced with passive devices. This will reduce the peak heat rejection rate of the ADR to less than 7 mW at 6 K. Details of the ADR s design and operation, as well as the development program leading up to a flight-qualified instrument, will be discussed.

Shirron, Peter↗

Proceedings of the Third Infrared Detector Technology Workshop

This volume consists of 37 papers which summarize results presented at the Third Infrared Detector Technology Workshop, held February 7-9, 1989, at Ames Research Center. The workshop focused on infrared (IR) detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers on discrete IR detectors, cryogenic readouts, extrinsic and intrinsic IR arrays, and recent results from ground-based observations with integrated arrays were given. Recent developments in the second-generation Hubble Space Telescope (HST) infrared spectrometer and in detectors and arrays for the European Space Agency's Infrared Space Observatory (ISO) are also included, as are status reports on the Space Infrared Telescope Facility (SIRTF) and the Stratospheric Observatory for Infrared Astronomy (SOFIA) projects.

Mccreight, Craig R.↗