Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Denver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electrifying High-Efficiency Future Communities: Impact on Energy, Emissions, and Grid

To combat climate change and meet decarbonization goals, the building sector is improving energy efficiency and electrifying end uses to reduce carbon emissions from fossil fuels. All-electric buildings are becoming a trend among new constructions, introducing opportunities for decarbonization but also technical challenges and research gaps. For instance, further investigation is needed to understand how the adoption of energy efficiency measures (EEMs) and distributed energy resources (DERs) in all-electric communities would affect energy consumption, carbon emissions, and grid planning. This paper presents a case study of a mixed-use, all-electric community located in Denver, Colorado. We use URBANopt TM , a physics-based urban energy modeling platform to model the community and then evaluate the impact of EEMs and DERs (i.e., photovoltaics [PV], electric vehicles [EVs], and batteries) on the community's energy usage, carbon emissions, and peak demand. The results show that adding EEMs and PV led to both energy consumption and carbon emissions reductions across all building types. However, we saw fairly limited impact of EEMs and PV on buildings' peak demand in our case. Additionally, due to overnight EV charging activities and higher grid carbon intensity at night, the carbon emissions in multifamily buildings have a noticeable increase compared to scenarios without vehicles. Finally, the addition of batteries helped reduce peak demand by 11%-29%. The modeling workflow and evaluation methods can be applied to similar communities to evaluate their performance and the effect of integrating EEMs and DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ammonia in northeast Colorado is increasing, rising most quickly in regions close to confined animal feeding operations

The Colorado Front Range urban corridor and nearby agricultural operations are important source regions of atmospheric ammonia (NH 3 ). Upslope flows periodically transport these emissions into Rocky Mountain National Park (RMNP), located 50 km west of the urban corridor, where wet and dry deposition of excess reactive nitrogen (N) impacts ecosystems. Here, we use a combination of in situ passive NH 3 measurements and NH 3 vertical column density retrievals from the Infrared Atmospheric Sounding Interferometer (IASI) to assess variability and changes in NH 3 across three land use categories in the northeast Colorado source region (agricultural, urban, and remote) during the period 2013-2023. A strong seasonal cycle is present across the region with increased NH 3 during summer months. Elevated NH 3 is spatially correlated with the number of permitted animal units in confined animal feeding operations (CAFOs) within 12 km. Ground-level NH 3 concentrations are strongly positively correlated with monthly gridded IASI satellite column densities. Satellite retrievals reveal an increasing trend in NH 3 column amounts of ∼3% per year in agricultural and ∼2% per year in urban sub-regions. The magnitude of the trend observed in NH 3 columns averaged over the agricultural sub-region is > 3 times larger than observed near and over Denver. The largest increases in NH 3 are closely aligned with the distribution of CAFOs. Reductions in particle sulfate associated with declining sulfur dioxide (SO 2 ) emissions could account for only ∼0.1% per year increase in gaseous NH 3 . Wildfire smoke across the region has increased but appears unlikely to explain the majority of the observed NH 3 increase.

54 ENVIRONMENTAL SCIENCES↗

Long-term CRISPR locus dynamics and stable host-virus co-existence in subsurface fractured shales

Viruses are the most ubiquitous biological entities on Earth. Even so, elucidating the impact of viruses on microbial communities and associated ecosystem processes often requires identification of unambiguous host-virus linkages-an undeniable challenge in many ecosystems. Subsurface fractured shales present a unique opportunity to first make these strong linkages via spacers in CRISPR-Cas arrays and subsequently reveal complex long-term host-virus dynamics. Here, we sampled two replicated sets of fractured shale wells for nearly 800 days, resulting in 78 metagenomes from temporal sampling of six wells in the Denver-Julesburg Basin (Colorado, USA). At the community level, there was strong evidence for CRISPR-Cas defense systems being used through time and likely in response to viral interactions. Within our host genomes, represented by 202 unique MAGs, we also saw that CRISPR-Cas systems were widely encoded. Together, spacers from host CRISPR loci facilitated 2,110 CRISPR-based viral linkages across 90 host MAGs spanning 25 phyla. We observed less redundancy in host-viral linkages and fewer spacers associated with hosts from the older, more established wells, possibly reflecting enrichment of more beneficial spacers through time. Leveraging temporal patterns of host-virus linkages across differing well ages, we report how host-virus co-existence dynamics develop and converge through time, possibly reflecting selection for viruses that can evade host CRISPR-Cas systems. Together, our findings shed light on the complexities of host-virus interactions as well as long-term dynamics of CRISPR-Cas defense among diverse microbial populations.

59 BASIC BIOLOGICAL SCIENCES↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic and operational investigation of CO 2 sequestration through enhanced oil recovery in unconventional reservoirs in Colorado, USA

The ongoing CCUS commercial projects are highly relied on the support of government incentives due to massive capital investment. Here, this study analyzes the economics of carbon capture utilization and sequestration (CCUS) projects, shows a state-wide CCUS deployment exercise, followed by simulation results of enhanced oil recovery (EOR) based CO 2 storage in unconventional reservoirs. The comprehensive economic analysis of capture, transportation, sequestration costs, enhanced 45Q tax credits, and EOR revenue implies the practicality of CO 2 -EOR to offset the high CCUS costs. With the economics understanding, we study the top CO 2 sources, existing CO 2 pipelines, and sequestration sinks in the state of Colorado, USA. This paper next presents results from EOR simulation in one section of the unconventional Denver-Julesburg (DJ) Basin Niobrara and Codell reservoirs. The simulation model is based on a geological static model, incorporated with hydraulic fracture stimulation, history matched to production, and calibrated to the microseismic and time-lapse surface seismic data. The CO 2 -EOR simulation results show that oil production can be increased and more CO 2 stored with: a longer primary production period; the presence of a shut-in period; higher injection rates; and multi-well injectors. The modeling results show that about 7–10 Mscf of CO 2 will be stored when recovering 1 stb of EOR oil. By adding the enhanced oil revenue and the carbon credits together, it is estimated that the most economic case can generate $\$13$ MM when oil price is assumed to be $\$80$/stb, and the EOR oil revenue is 3.4 times greater than that generated from 45Q incentives. It corresponds to the scenario that a five-year primary production is followed by CO 2 injection into four wells with the sequence of injection (4 MMscf/day for 6 months), shut-in (6 months) and production (12 months). The best practices in this study will provide valuable insights for similar CCUS projects in other unconventional fields. Furthermore, this study defines a term named “Carbon Neutrality Index (CNI)” by comparing the amount of CO 2 stored with that burned by EOR oil. The CNI value of 0 indicates the enhanced oil is carbon neutral; a negative CNI value implies there is a net reduction in carbon emission. The 4-year huff-n-puff (HnP) simulation leads to a positive CNI value, indicating that the EOR oil generated in this process is not carbon neutral yet.

03 NATURAL GAS↗

Cost details from front-end engineering design of piperazine with the advanced stripper

This Front-End Engineering Design (FEED) was funded by the U.S. Department of Energy (DOE) to estimate the cost to capture and compress 90% of the CO 2 from an existing natural gas combined cycle (NGCC) in Denver City, Texas, USA. The FEED used the PZAS (Piperazine with the Advanced Stripper) 2G amine scrubbing technology developed and modeled by The University of Texas at Austin. This FEED is unique in providing more public cost details than other FEEDs funded by DOE. The primary objective of the FEED was to provide a comprehensive estimate for the total installed cost of the capture plant. The estimated capital cost of NGCC at the Mustang Station is $\$727$ million for a capacity of 460 MW and 1.6 million tonnes CO 2 /yr. This includes a contingency of $\$104.6$ million and a contractor’s profit of $\$60.1$ million. The total direct field cost is $\$384.1$ million. With an optimistic fuel value of $\$3$/MMBtu, the estimated cost of capture varies from $\$85$/t at 4% IRR/85% load to $\$170$/t at 10% IRR/52% load. Air cooling is technically feasible but expensive. The air cooling systems for the water wash and pump-around intercooling account for 23.4% of the direct cost. The gas-fired boilers represent only 4% of the direct costs, but steam extraction would reduce energy cost, free up cooling water, and reduce the direct costs of processing additional flue gas and CO 2 from the boilers. The absorbers represent 9.6% of the direct cost in this FEED with no direct contact cooler and only 7.6 m of packing. Furthermore, the solvent cross exchangers are less expensive than expected (2.5% of direct costs). Doubling the number of these exchangers could reduce the heat duty from 3.0 to 2.5 GJ/t CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hand me the franchise agreement: municipalities add another policy tool to their clean energy toolbox

A growing list of the more than 20,000 municipalities in the United States are considering pathways to achieve renewable energy goals. One emerging trend is for municipalities to incorporate energy objectives into their franchise agreements with an electric service provider. Franchise agreements are contracts between municipalities and utilities that grant the utility authority to serve customers in the municipality. In some cases, municipalities have negotiated renewable energy objectives into these agreements. It is still unclear how many municipalities have exercised this authority and to what effect. From a national dataset of 3500 franchise agreements, we selected five cities that adopted renewable energy or energy efficiency objectives into or alongside their franchise agreements for deeper analysis: Chicago, Illinois; Denver, Colorado; Sarasota, Florida; Minneapolis, Minnesota; and Salt Lake City, Utah. We generated seven key takeaways for other cities considering this pathway to achieve their energy objectives. In summary, municipalities can leverage franchise negotiations to pursue both modest and ambitious clean energy goals (i.e. 100% renewable electricity). This study provides municipalities with critical insight on how they can use this potentially formidable tool to achieve their own energy objectives.

14 SOLAR ENERGY↗

Membrane Bioreactor Pretreatment of High-Salinity O&G Produced Water

Produced water (PW) from oil and gas production contains variable constituents that are difficult to remove with conventional treatment processes. The focus of this study was to explore the long-term performance of a membrane bioreactor (MBR) for the removal of organic constituents from PW and how performance and microbial community composition are affected by progressively increasing salinity and introduction of PW from different shale basins around the United States. Dissolved organic carbon removal from the PW remained consistent throughout the study, averaging 86% from the Denver-Julesburg basin PW and 66% removal from the Permian basin PW. Surfactant removal was less consistent, showing 87% removal of poly(ethylene glycols) (PEGs) at a total dissolved solid (TDS) concentration of 40 g/L but only 58% removal at a TDS concentration of 100 g/L. Diversity in the microbial community decreased during reactor establishment but increased at TDS concentrations above 80 g/L. Finally, the results of this study suggest that MBRs can be effective PW pretreatment processes even at high salinities.

42 ENGINEERING↗

A Coupled Deep Learning Model for Estimating Surface NO 2 Levels from Remote Sensing Data: 15-Year Study Over the Contiguous United States

This study proposes a novel two-step deep learning (DL) model for estimating surface NO 2 concentrations using satellite data over the contiguous United States (CONUS) from 2005 to 2019. The first phase of the model uses partial convolutional neural network (PCNN), an advanced DL model that accurately imputes gaps between surface NO 2 stations and creates 5,478 daily-mean NO 2 grids (PCNN-NO 2 ) of the 2005-2019 period over the study area. We then feed the PCNN-NO 2 , along with other predictor variables, into a deep neural network (DNN) to estimate surface NO 2 levels, achieving exceptional performance with a correlation coefficient of 0.975 to 0.978, a mean absolute bias of 0.99 ppb to 1.38 ppb, and a root mean square error of 1.47 ppb to 1.97 ppb. Spatial cross-validation results also indicate strong spatial performance of PCNN-DNN surface NO 2 estimates. In addition to its accurate estimates, the PCNN-DNN model consistently generates estimated NO 2 grids without any missing values, improving the quality of various applications such as emission reduction strategies and public health studies. Between 2005 and 2019, the 5,478 daily estimated NO 2 grids over the CONUS reveal significant reductions in NO 2 levels in fourteen major urban environments: Washington D.C. (-43%), New York (-45%), Los Angeles (-38%), Chicago (-25%), Boston (-43%), Houston (-34%), Dallas (-40%), Philadelphia (-41%), Phoenix (-38%), Detroit (-20%), Denver (-23%), Atlanta (-0.7%), Cincinnati (-38%), and Pittsburgh (-56%). Furthermore, the study shows that the denser urban regions that in-situ stations are installed in, the higher the difference between in-situ observations and regional-mean NO 2 levels.

54 ENVIRONMENTAL SCIENCES↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Pricing Strategy of Electric Vehicle Aggregators Based on Locational Marginal Price to Minimize Photovoltaic (PV) Curtailment

The global climate crisis demands urgent action to mitigate global warming. Using renewable energy sources, such as solar and wind power, for electricity generation is crucial. This shift from centralized to distributed power systems, however, brings challenges, including voltage fluctuations and renewable energy curtailment. The rapid growth of the electric vehicle (EV) industry adds complexity, increasing overall electricity demand and straining the power supply during peak charging times. This paper proposes a scheduling strategy for EV aggregators to reduce renewable energy curtailment and stabilize grid operation by strategically scheduling EV charging. Using Multi -Agent Transport Simulation (MATSim), a traffic simulation tool, EV driving data in Denver, Colorado, USA, were modeled. The EV aggregator adjusts charging fees based on locational marginal prices, encouraging EVs to charge at different stations according to pricing. Simulations on an IEEE 33-bus system with distributed energy resources and EV charging stations validate the proposed algorithm, demonstrating its effectiveness in reducing curtailment by 12.55% and stabilizing grid operation.

33 ADVANCED PROPULSION SYSTEMS↗

HPC and Cloud Convergence Beyond Technical Boundaries: Strategies for Economic Sustainability, Standardization, and Data Accessibility

At the IEEE/ACM International Conference for High-Performance Computing, Networking, Storage, and Analysis (SC23), held in Denver, experts discussed the convergence of high-performance computing and cloud computing. Experts explored how this integration could address current scientific computing limitations, enhance computational capabilities, and foster global collaboration while focusing on economic, security, technical, and community challenges and opportunities.

97 MATHEMATICS AND COMPUTING↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

How Time Inefficient and Uncertain are Paratransit Trips Compared to Car Trips

The Americans with Disabilities Act (ADA) stipulates that paratransit mobility be comparable to public transit. However, with just under 5% of the population relying on public transportation, transit is not a representative benchmark. To highlight this inequality, we compare trip times by paratransit to counterfactual car-based travel. Using 2.5 years of demand data from the Denver Regional Transportation District's Access-a-Ride service, we compare paratransit trip times to counterfactual car-based trips for the same origin-destination pairs, controlling for various trip characteristics. Compared to car travel, the findings indicate high variability and uncertainty associated with paratransit trip times. For the same origin-destination pairs, the mean paratransit trip time is almost twice that of the mean car travel time, with a standard deviation for paratransit trip time fourfold that of the standard deviation for car trip time. For perspective, traveling an average of 10 mi during the 7-8 a.m. morning peak can take about 16 min by car with almost no variability, while that same trip can take an average of 25 min by paratransit, with 5% of trips being outside the 95% confidence interval and thus unpredictable. Paratransit trip time inefficiency tends to be particularly worse for females; older adults; those making trips between 9 and 11 a.m.; cash-paying customers; those making shorter trips; and those traveling during inclement weather, including cold temperatures. These findings suggest a need to re-assess using public transit as a benchmark for paratransit supply as regulated by the ADA.

accessible transportation and mobility↗