Analysis of Silver Release from Furnace-Tested TRISO Particles
High temperature testing of intact TRISO particles previously irradiated in the AGR-5/6/7 experiment was performed in the Furnace for Irradiated TRISO Testing (FITT) to directly confirm diffusive release of silver and europium from intact TRISO particles. Testing was conducted from 1,100–1,600°C for exposure times up to 100 h to directly confirm silver through layer release below safety testing temperatures. The FITT analysis showed highest levels of silver release at 1,300–1,400°C which confirms athermal release behaviors previous observed in step-wise and transient safety tests. Additionally, release was non-uniform with some particles releasing a majority of their inventory while others did not appear to release silver under identical testing conditions, which was consistent with historic observations. An assessment of the effective silver diffusion coefficient in the SiC layer was conducted and indicated maximum values in the 1,300–1,400°C range. The magnitude of the calculated diffusion coefficients also exceeded currently accepted diffusion coefficients. The release behavior of europium from intact particles was also analyzed in FITT for at 1,450–1,550°C for 500 h to 750 h. Direct confirmation of europium release below safety testing temperatures was confirmed absent contributions from matrix release. The analysis indicated europium release follows a general Arrhenius behavior and suggests general uniform release and indicates irradiation conditions influence observed release response. Calculated diffusion kinetics agree well with historic experiments.