SEARCH · Engineering Papers
Results for “DHS”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Improved Platform for the Benchtop Study of Complex Radiological Environments that Affect Fallout Formation: DHS Feasbility Study (Final Report)
Fallout analysis is a crucial field of study as it provides insight into the structural interactions that occur between radiological components and their surroundings following a nuclear event. Due to the complexity of actual fallout samples, setups like the plasma flow reactor (PFR) at LLNL have been developed to synthesize fallout in a controlled environment. While the PFR allows for control of parameters such as initial temperature, cooling rate, and concentration of radiological species, controlling the concentration of water has remained a challenge as samples are introduced into the setup via aqueous solution. To that end, our goal with this project was to develop methodologies to (1) monitor and (2) control the presence of water in the PFR. We found that a commercially available FTIR and MCT detector was sufficient to monitor the presence of both condensed and vapor-phase water, while a desolvating nebulizer could be used to control the amount of water injected into the system. In total, the results of this feasibility study have expanded the ability of the flow reactor to investigate key sensitivities that influence fallout formation.
Cutting-Edge Chem/Bio Plume Modeling & Detection Architecture Design: DHS S&T Urban Model Integration Program
Explore the source record for details and available documents.
DHS Research Experience Summary
I learned a great deal during my summer internship at Lawrence Livermore National Laboratory (LLNL). I plan to continue a career in research, and I feel that my experience at LLNL has been formative. I was exposed to a new area of research, as part of the Single Particle Aerosol Mass Spectrometry (SPAMS) group, and I had the opportunity to work on projects that I would not have been able to work on anywhere else. The projects both involved the use of a novel mass spectrometer that was developed at LLNL, so I would not have been able to do this research at any other facility. The first project that Zachary and I worked on involved using SPAMS to detect pesticides. The ability to rapidly detect pesticides in a variety of matrices is applicable to many fields including public health, homeland security, and environmental protection. Real-time, or near real-time, detection of potentially harmful or toxic chemical agents can offer significant advantages in the protection of public health from accidental or intentional releases of harmful pesticides, and can help to monitor the environmental effects of controlled releases of pesticides for pest control purposes. The use of organophosphate neurotoxins by terrorists is a possibility that has been described; this is a legitimate threat, considering the ease of access, toxicity, and relatively low cost of these substances. Single Particle Aerosol Mass Spectrometry (SPAMS) has successfully been used to identify a wide array of chemical compounds, including drugs, high explosives, biological materials, and chemical warfare agent simulants. Much of this groundbreaking work was carried out by our group at LLNL. In our work, we had the chance to show that SPAMS fulfills a demonstrated need for a method of carrying out real-time pesticide detection with minimal sample preparation. We did this by using a single particle aerosol mass spectrometer to obtain spectra of five different pesticides. Pesticide samples were chosen to represent four common classes of pesticides that are currently used in the US. Permethrin (a pyrethrin insecticide), dichlorvos and malathion (organophosphates), imidacloprid (a chloronicotinyl pesticide), and carbaryl (a carbamate) were selected for analysis. Samples were aerosolized either in water (using a plastic nebulizer) or in ethanol (using a glass nebulizer), and the particles entered the SPAMS instrument through a focusing lens stack. The particles then passed through a stage with three tracking lasers that were used to determine each particle's velocity. This velocity was used to calculate when to fire a desorption/ionization (D/I) laser in order to fragment the particle for analysis in a dual polarity time of flight mass spectrometer. Signals were digitized, and then analyzed using LLNL-developed software. We obtained chemical mass spectral signatures for each pesticide, and assigned peaks to the mass spectra based on our knowledge of the pesticides chemical structures. We then proved the robustness of our detection method by identifying the presence of pesticides in two real-world matrices: Raid{trademark} Ant Spray and a flea collar. To sample these, we simply needed to direct aerosolized particles into the SPAMS instrument. The minimal sample preparation required makes SPAMS very attractive as a detector. Essentially, we were able to show that SPAMS is a reliable and effective method for detecting pesticides at extremely low concentrations in a variety of matrices and physical states. The other project that I had the opportunity to be a part of did not involve data collection in the lab; it consisted of analyzing a large amount of data that had already been collected. We got to look at data collected over the course of about two months, when the SPAMS instrument was deployed to a public place. The machine sampled the air and collected spectra for over two months, storing all the spectra and associated data; we then looked at an approximately two-month subset of this data to search for patterns in the types of particles being detected. Essentially, we were able to identify particle types among all the spectra collected by clustering the spectra into groups of similar spectra. This was done using software that had been previously developed by our group (Dr. Paul Steele, a former group member, was instrumental in helping us learn how to use the software). Once we had found particles that seemed to recur, we faced the task of trying to figure out what these particles were. To do this, we compared the average spectra for each major cluster to those of several common compounds. We were able to tentatively identify at least one compound this way. We also looked at patterns in the appearance of different compounds. For instance, there were some compounds that only appeared at certain times of the day.
DHS Internship Summary-Crystal Assembly at Different Length Scales
I was part of a project in which in situ atomic force microscopy (AFM) was used to monitor growth and dissolution of atomic and colloidal crystals. At both length scales, the chemical environment of the system greatly altered crystal growth and dissolution. Calcium phosphate was used as a model system for atomic crystals. A dissolution-reprecipitation reaction was observed in this first system, involving the conversion of brushite (DCPD) to octacalcium phosphate (OCP). In the second system, polymeric colloidal crystals were dissolved in an ionic solvent, revealing the underlying structure of the crystal. The dissolved crystal was then regrown through an evaporative step method. Recently, we have also found that colloids can be reversibly deposited in situ onto an ITO (indium tin oxide) substrate via an electrochemistry setup. The overall goal of this project was to develop an understanding of the mechanisms that control crystallization and order, so that these might be controlled during material synthesis. Controlled assembly of materials over a range of length scales from molecules to nanoparticles to colloids is critical for designing new materials. In particular, developing materials for sensor applications with tailorable properties and long range order is important. In this work, we examine two of these length scales: small molecule crystallization of calcium phosphate (whose crystal phases include DCPD, OCP, and HAP) and colloidal crystallization of Poly(methyl methacrylate) beads. Atomic Force Microscopy is ideal for this line of work because it allows for the possibility of observing non-conducting samples in fluid during growth with high resolution ({approx} 10 nm). In fact, during atomic crystal growth one can observe changes in atomic steps, and with colloidal crystals, one can monitor the individual building blocks of the crystal. Colloids and atoms crystallize under the influence of different forces acting at different length scales as seen in Table 1. In particular, molecular crystals, which are typically dominated by ionic and covalent bonding, are an order of magnitude more strongly bonded than colloidal crystals. In molecular crystals, ordering is driven by the interaction potentials between molecules. By contrast, colloidal assembly is a competition between the repulsive electrostatic forces that prevent aggregation in solution (due to surface charge), and short-range van der Waals and entropic forces that leads to ordering. Understanding atomic crystallization is fundamentally important for fabrication of tailorable crystalline materials, for example for biological or chemical sensors. The transformation of brushite to OCP not only serves as a model system for atomic crystal growth (applicable to many other crystal growth processes), but is also important in bone cements. Colloidal crystals have unique optical properties which respond to chemical and mechanical stimuli, making them very important for sensing applications. The mechanism of colloidal crystal assembly is thus fundamentally important. Our in situ dissolution and regrowth experiments are one good method of analyzing how these crystals pack under different conditions and how defect sites are formed and filled. In these experiments, a silica additive was used to strengthen the colloidal crystal during initial assembly (ex situ) and to increase domain size and long range order. Reversible electrodeposition of colloids onto a conductive substrate (ITO in our case) is another system which can further our knowledge of colloidal assembly. This experiment holds promise of allowing in situ observation of colloidal crystal growth and the influence of certain additives on crystal order. The ultimate goal would be to achieve long range order in these crystals by changing the surface charge or the growth environment.
Critical issues in process control system security : DHS spares project.
The goals of this event are: (1) Discuss the next-generation issues and emerging risks in cyber security for control systems; (2) Review and discuss common control system architectures; (3) Discuss the role of policy, standards, and supply chain issues; (4) Interact to determine the most pertinent risks and most critical areas of the architecture; and (5) Merge feedback from Control System Managers, Engineers, IT, and Auditors.
DHS Science and Technology Directorate Chemical Supply Chain and Resilience Project: Data Serves a Core Role.
Abstract not provided.
Consequence Analysis for DHS Chemical-Sector Risk and Resilience Programs.
Abstract not provided.
DHS Student Internship Experience Summary by Wai Fai Lau.
Abstract not provided.
DHS S&T Support of NLE11 Using SUMMIT - 2nd submission.
Abstract not provided.
DHS HS-STEM Summer Internship Written Presentation: Mark Andrew Garner.
Abstract not provided.