Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA READOUT SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Parameter extraction for a SPICE model of an hTron superconducting thermal switch

Efficiently simulating large circuits is crucial to the development of superconducting nanowire-based electronics. However, current simulation tools for this technology are not adapted to the scaling of circuit size and complexity. We focus on the multilayered heater-nanocryotron (hTron), a promising superconducting nanowire-based switch used in applications such as superconducting nanowire single-photon detector readout. Previously, the hTron was modeled using traditional finite-element methods, which fall short in simulating systems at a larger scale. An empirical-based method would be better adapted to this task, enhancing both simulation speed and agreement with experimental data. In this work, we perform switching current and activation delay measurements on 17 hTron devices. We then develop a method for extracting physical fitting parameters used to characterize the devices. We build a SPICE behavioral model that reproduces the static and transient device behavior using these parameters, and validate it by comparing its performance to a model developed in prior work, showing an improvement in simulation time by several orders of magnitude. Furthermore, our model provides circuit designers with a tool to help understand the hTron’s behavior during all design stages, thus enabling broader use of the hTron across various new areas of application.

Caloritronics↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

TinyTPC: A Test Stand for LAr Doping

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) featuring a pixelated readout system (LArPix) designed to improve the detection of charged particles. To enhance energy measurements at MeV scales, TinyTPC will study the impact of isobutylene, a photosensitive dopant that converts light to charge, and xenon, a wavelength shifter. This presentation will detail TinyTPC's commissioning, operation, data collection methodologies, noise levels, and upcoming tests involving isobutylene, xenon, and radioactive sources.

43 PARTICLE ACCELERATORS↗

Single-cell proteomics of Arabidopsis leaf mesophyll reveals dynamic protein responses to water-deficit stress

Background The application of single-cell omics tools to biological systems can provide unique insights into diverse cellular populations and their heterogeneous responses to internal and external perturbations. Thus far, most single-cell studies in plant systems have been limited to RNA-sequencing approaches, which only provide indirect readouts of cellular functions. Results Here, we present a single-cell proteomics workflow for plant cells that integrates tape-sandwich protoplasting, piezoelectric cell sorting, nanoPOTS sample preparation, and ion mobility-based MS data acquisition method for label-free single-cell proteomics analysis of Arabidopsis leaf mesophyll cells. From a single leaf protoplast, over 3,000 proteins were quantified with high precision. The workflow is demonstrated to identify stress associated changes in protein abundance by analyzing 117 protoplasts from well-watered and water-deficit stressed plants. Additionally, we describe a new approach for constructing covarying protein networks at the single-cell level and demonstrate how single-cell protein covariation analysis can reveal previously unrecognized protein functions while also capturing stress-induced changes in protein–protein dynamics. Conclusions The label-free scProteomic approach presented here represents a significant advance through the demonstration of a facile protoplast isolation method combined with deep and precise proteomic coverage of Arabidopsis leaf mesophyll cell types. We believe this study will serve as an informative reference to future plant scProteomic investigations.

Arabidopsis↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Nucleon structure studies: DVCS on polarised protons with the CLAS12 experiment, and development of Micromegas detectors for EIC

The quark and gluon structure of nucleons is crucial for understanding the origin of their mass and spin. This information is encoded in structure function such as Generalised Parton Distributions (GPDs), which provide a three-dimensional picture of the nucleon in terms of its constituents. Deeply Virtual Compton Scattering (DVCS) offers the most direct access to GPDs, but their extraction requires high-precision measurements of multiple observables over a wide kinematic range. In 2022 and 2023 the CLAS12 experiment at Jefferson Lab (JLab) collected data from polarised electron scattering on a longitudinally polarised proton target, enabling the first measurement of polarised DVCS asymmetries at JLab 12GeV kinematics. This thesis will present preliminary measurement of the beam, target and double spin DVCS asymmetries from the CLAS12 polarised proton target data. Nucleon structure studies will also constitute a major part of the physics program at the future Electron Ion Collider (EIC). The development of the first detector at the EIC is ongoing and it requires light Micro-Pattern Gaseous Detectors (MPGDs) for its tracking system. This thesis further reports initial tests of Micromegas MPGDs with a two-dimensional readout developed for EIC.

Polcher, Samy [Univ. Paris-Saclay, Gif-sur-Yvette ↗

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION↗

Determining Optimal Running Conditions for TinyTPC Detector

Liquid argon time projection chambers, (LArTPCs), are particle detectors used to collect ionization charge information from particle trajectories, facilitating detailed particle track analysis. They are currently used as particle detectors in major physics projects such as the deep underground neutrino experiment (DUNE), to detect and study the nature of the elusive neutrino particle. TinyTPC is a small scale LArTPC featuring a pixelated readout system (LArPix) that we will use to study liquid argon doping. We expect this doping to enhance the resolution of LAr detectors, especially for low energy particles below 10 MeV which would expand the capabilities of currently running experiments. Housed within a cryostat filled with liquid argon, the TinyTPC will rely on a high and a low voltage system to collect data. In preparation for deployment we found and resolved issues in the HV and LV systems and we determined optimal running conditions in a test vessel. This presentation will go over the detector commissioning process that enabled data taking with the TinyTPC.

Gonzalez, Rebecca↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Real Time implementation of Artificial Intelligence compression algorithm for High-Speed Streaming Readout signals

The new generation of high-energy physics experiments plans to acquire data in streaming mode. With this approach, it is possible to access the information of the whole detector (organized in time slices) for optimal and lossless triggering of data acquisitions. With this approach, data rates, especially in large detectors, are often very high, and the network is likely to be the bottleneck for the entire Streaming Read Out system. The aim of this work is to study the implementation of a lossy compression algorithm based on Artificial Intelligence: an Autoencoder. With Machine Learning it is possible to achieve a high compression ratio and fast inference time with only a small degradation of the signals, almost negligible for the specific application. This work explores different configurations of the Autoencoder and the implementation on different hardware. Different Autoencoder configurations are explored to find the best trade-off between compression ratio and reconstruction loss, both for signals and energy spectrum. Different hardware implementations are also explored to find the best platform to achieve real-time performance for the specific application.

Rossi, Fabio (ORCID:0009000385713885)↗

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons↗

Statistics and sensitivity of axion wind detection with the homogeneous precession domain of superfluid helium-3

The homogeneous precession domain (HPD) of superfluid He 3 has recently been identified as a detection medium which might provide sensitivity to the axion-nucleon coupling g a N N competitive with, or surpassing, existing experimental proposals. In this work, we make a detailed study of the statistical and dynamical properties of the HPD system in order to make realistic projections for a full-fledged experimental program. We include the effects of clock error and measurement error in a concrete readout scheme using superconducting qubits and quantum metrology. This work also provides a more general framework to describe the statistics associated with the axion gradient coupling through the treatment of a transient resonance with a nonstationary background in a time-series analysis. Incorporating an optimal data-taking and analysis strategy, we project a sensitivity approaching g a N N ∼ 10 − 12 GeV − 1 across a decade in axion mass. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Operationally induced preferred basis in unitary quantum mechanics

The preferred-basis problem and the definite-outcome aspect of the measurement problem persist even if the detector is modeled unitarily, because experimental data are necessarily represented in a Boolean event algebra of mutually exclusive records whereas the theoretical description is naturally formulated in a noncommutative operator algebra with continuous unitary symmetry. This change of mathematical type constitutes the core of the 'cut': a structurally necessary interface from group-based kinematics to set-based counting. In the presented view the basis relevant for recorded outcomes is not determined by the system Hamiltonian alone; it is induced by the measurement mapping, i.e., by the detector channel together with the coarse-grained readout that defines an instrument. The probabilistic mapping is anchored in symmetry and measure theory: by Gleason-type uniqueness (Gleason for projections in $d>2$ and Busch's extension for Positive Operator-Valued Measures (POVMs) including $d=2$), the trace rule is the unique probability measure consistent with additivity over exclusive events and basis-independence of the unitary sector. A compact qubit--pointer model yields an induced unsharp POVM $E_\pm=\tfrac12(\id\pm η\,σ_z)$ with $η$ fixed by pointer resolution, displaying explicitly how the detector induces the relevant basis. Finally, nested-observer paradoxes are tightened into a non-composability lemma: joint assignment of outcome propositions is obstructed unless a joint instrument exists. This relocates the origin of randomness to the stochasticity of the transition rules.

Pronskikh, Vitaly [Fermilab] (ORCID:00000002518174↗

Using pile-up collisions as an abundant source of low-energy hadronic physics processes in ATLAS and an extraction of the jet energy resolution

During the 2015–2018 data-taking period, the Large Hadron Collider delivered proton-proton bunch crossings at a centre-of-mass energy of 13 TeV to the ATLAS experiment at a rate of roughly 30 MHz, where each bunch crossing contained an average of 34 independent inelastic proton-proton collisions. The ATLAS trigger system selected roughly 1 kHz of these bunch crossings to be recorded to disk. Offline algorithms then identify one of the recorded collisions as the collision of interest for subsequent data analysis, and the remaining collisions are referred to as pile-up. Pile-up collisions represent a trigger-unbiased dataset, which is evaluated to have an integrated luminosity of 1.33 pb -1 in 2015–2018. This is small compared with the normal trigger-based ATLAS dataset, but when combined with vertex-by-vertex jet reconstruction it provides up to 50 times more dijet events than the conventional single-jet-trigger-based approach, and does so without adding any additional cost or requirements on the trigger system, readout, or storage. The pile-up dataset is validated through comparisons with a special trigger-unbiased dataset recorded by ATLAS, and its utility is demonstrated by means of a measurement of the jet energy resolution in dijet events, where the statistical uncertainty is significantly reduced for jet transverse momenta below 65 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗