Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cyber-physical System Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

Cybersecurity Incident Response Guide for Wind

As wind energy systems become increasingly digitized and interconnected, they face a growing array of cyber threats that can disrupt operations, compromise safety, and trigger cascading impacts across the energy ecosystem. The Wind Incident Response Guide provides a structured, wind-specific framework for preparing for, detecting, responding to, and recovering from cyber incidents. Drawing on lessons from field demonstrations, cyber-physical testbeds, and stakeholder engagement across the wind sector, this guide integrates technical, operational, and regulatory considerations to support asset owners, operators, and responders. It outlines key roles and responsibilities, maps incident response phases to wind-specific scenarios, and highlights applicable laws, regulations, standards, and best practices. By tailoring general cybersecurity principles to the unique architectures and operational constraints of wind systems—including remote access, legacy components, and environmental interfaces—this guide aims to enhance resilience, reduce response time, and support coordinated action across public and private stakeholders. It is intended as a practical resource for utilities, developers, regulators, and emergency managers working to secure the future of wind energy.

17 - WIND ENERGY↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Critical Energy Infrastructure Cybersecurity: Enhanced Cyber Resilience for Federal Energy Systems

This presentation is an overview of FEMP Resilient and Secure Infrastructure and Facilities. An educational and interactive workshop centered on resilient and secure federal infrastructure and facilities, with a focus on inverter-based resources at Federal sites, building automation systems, and Federal supply chains. This workshop will illustrate an all-hazards scenario and discuss how Federal agencies can be positioned to resist these real-world scenarios.

97 MATHEMATICS AND COMPUTING↗

A distributed voltage inference framework for cyber-physical attacks detection and localization in active distribution grids

The transition to active distribution grids with real-time monitoring and control depends on the proliferation of advanced communication networks and devices. This paradigm shift towards a cyber-physical architecture also introduces new vulnerabilities for adversaries to exploit and launch sophisticated cyber-physical attacks targeting grid observability. Current research highlights the challenges in distinguishing attacks on voltage phasor or nodal injection measurements and isolating multi-source attack locations in a multiphase distribution grid. The attack detection and localization methods in literature face accuracy issues, applications across diverse attack scenarios, or scalability limits. Here, to bridge these gaps, this paper proposes a distributed Voltage Inference framework for real-time detection and localization of cyber-physical attacks, addressing scalability, adaptability, and accuracy challenges in state-of-the-art methods. The proposed methodology leverages the distributed nature of the Voltage Inference framework through a two-step process of prediction and correction, together with a tractable graph partitioning approach, providing a reliable solution to identify compromised measurement sources and facilitate isolation. Extensive testing on IEEE 13 and 123-node distribution feeders underscores the algorithm’s efficacy, enhancing the security and resilience of active distribution grids against evolving cyber threats. Additionally, Hardware-in-the-Loop (HIL) implementation validates the proposed strategy’s practical applicability in real-world scenarios.

active distribution grids↗

Oakland University Cybersecurity Center (Final Scientific/Technical Report)

This report summarizes the outcomes of Award DE-CR0000023, “Oakland University Cybersecurity Center,” a 31-month project funded by the U.S. Department of Energy Office of Cybersecurity, Energy Security, and Emergency Response (CESER). The project addressed cybersecurity risks facing small and medium-sized manufacturers (SMMs) transitioning to Industry 4.0. The project integrated customer discovery, applied research, and cybersecurity training development. A total of 51 cybersecurity assessments identified significant gaps in baseline practices, incident response, and workforce capability. Research efforts produced a scalable mitigation framework tailored to SMM environments, and workforce analysis identified persistent talent gaps. Eight cybersecurity training modules were developed and deployed via Oakland University’s Professional and Continuing Education (PACE) platform. All objectives were completed, with 98.93% federal budget utilization and cost share exceeding requirements. The project establishes a scalable model for strengthening cybersecurity resilience and workforce capacity across U.S. manufacturing supply chains.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber‐Resilient Distributed Energy Resource Control Algorithms for Smart Distribution Grids

ABSTRACT This paper focuses on the development of cyber‐resilient gradient‐based optimisation algorithms and theoretical proof for grid‐interactive distributed energy resource (DER) control to enable two grid services of virtual power plants (VPPs) dispatch and grid voltage regulation, considering the communication and security impacts. Firstly, the combined DER dispatch and voltage regulation as a real‐time gradient‐based optimisation problem is recapped. Thereafter, we consider a probabilistic traffic model to characterise packet delays and loss in a communication network, and study how the delays enter the process of information exchange among the grid measurement units, local DER controllers and the grid control centre that execute this control algorithm in a coordinated manner. Then, a strategy combining delay thresholds and message update rules is proposed to immunity the asynchrony resulting from the communications traffic and it avoids possible numerical instabilities and sensitivities of the power tracking and voltage regulation capabilities, resulting as cyber‐resilient DER control algorithms. Additionally, their convergence is theoretically proved. Effectiveness of proposed cyber‐resilient algorithms has been validated on the IEEE 37‐bus system in terms of convergence, VPP tracking and voltage regulation performance for smart distribution systems with high penetration of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ARCADE (Advanced Reactor Cyber Analysis and Development Environment)

SAND2025-11780O ARCADE (Advanced Reactor Cyber Analysis and Development Environment) software performs cybersecurity experiments on Defensive Cyber Security Architectures (DCSA) for Distributed Control Systems (DCSs). The application is integrated into a cohesive environment that performs cyber risk analyses and reduces costs. ARCADE can investigate the entire cyber-attack surface of a DCS from the physics of control, down to the firmware of individual components with automated efficiency. ARCADE has five major functional components: the Data Broker system, the virtualization environment, the cyber-attack simulator, the cyber-physical analysis system, and the physics simulator. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Valme, Romuald↗

EV SALaD 2023 Demonstration: Best Practices and Mitigations for Protecting EVSE Infrastructure

The Electric Vehicle Secure Architecture Laboratory Demonstration (EV SALaD) program is a demonstration of cybersecurity best practices for high-power electric vehicle (EV) charging infrastructure led by Idaho National Laboratory (INL), in collaboration with other DOE National Laboratories participating in the EVs at Scale Consortium.a Sandia National Laboratories (SNL) and Pacific Northwest National Laboratory (PNNL) participated in the first 2-year (FY22-23) demonstration cycle for EV SALaD. This report documents the FY23 demonstration, the second in a series of demonstrations and collaborations in deploying and operating cybersecure EV charging infrastructure. It includes a summary of improvements from the FY22 demonstration, technical analysis of the FY23 demonstration, how the research demonstrates cyber-physical and cybersecurity best practices for high-power EV charging infrastructure, and related impacts to national and energy security. For EV SALaD, the FY22 demonstration focused on the detection, ranking, and prioritization of anomalous events for high-power EV charging. The FY23 demonstration additionally included the demonstration of cybersecurity best practices, which included protection and mitigation solutions to prevent, respond, and recover from anomalous events. During the demonstrations, the multi-lab EV SALaD team conducted a Test Effect Payload (TEP)b evaluation on extreme fast charger (XFC) hardware equipped with Cerberus, a detection and response solution, to demonstrate anomaly detection and mitigation cybersecurity best practices against cyber-enabled events.

33 ADVANCED PROPULSION SYSTEMS↗

National Security Programs - Cyber: MMAREJBLIGE – Modular Multi Agent Grid Emulation for Joined Breakdowns in Linked Generative Emulations - 23-0644

Modular Multi Agent Grid Emulations for Joined Breakdowns in Linked Generative Emulations (MMAREJBLIGE) introduces an agent-based modeling framework into real-time cyber-physical emulation to achieve a context-aware environment that introduces operator/attacker/external-condition variability to improve emulation fidelity and testing rigor. We detail our agent framework design, internal communication via message passing, and time synchronization, as well as the individual components of the system. We include a brief analysis of several scenarios run on a real-time, hardware-in-the-loop, Industrial Control Systems (ICS) test-bed which include normal operation, physical disruption, disruption with mitigation, and disruption with mitigation during a cyber denial-of-service (DOS) attack.

42 ENGINEERING↗

Integrating Cyber-Informed Engineering into Enterprise Risk Management

This document supports the application of Cyber-Informed Engineering (CIE) within the context of Enterprise Risk Management (ERM) to enhance cyber-resilience. It highlights that many critical infrastructure organizations use ERM to manage business risks and emphasizes the importance of evaluating critical systems and assets. The proposed approach can be adopted independently of formal ERM processes and offers a starting point for integrating CIE alongside existing or new ERM practices. Both CIE and ERM are iterative, and their alignment fosters continuous improvement and supports the engineering and operations cultures of an organization.

42 ENGINEERING↗

Cyber-Informed Engineering (CIE) Benefits Quantification: Recommendations for Consideration

Cyber-Informed Engineering (CIE) integrates engineering principles into the design, development, and operation of cyber-physical systems (CPS) to mitigate or eliminate the impact of cyber-enabled attacks. In July 2024, Idaho National Laboratory (INL) engaged MITRE researchers to investigate methods for systematically measuring the benefits of CIE implementation. This included evaluating the success and outcomes of CIE, identifying and quantifying the value of early adoption, and determining the business justification for its implementation, especially in existing infrastructure. MITRE reviewed existing methods in engineering and cybersecurity to understand how organizations prioritize security investments, considering their strengths, weaknesses, and relevance to CIE stakeholders. Based on this analysis, MITRE proposed potential approaches for quantifying CIE benefits and provided recommendations for INL's consideration.

42 ENGINEERING↗

ARCADE Analysis Methods & Validation Pathway

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) provides an automated analysis system which supports risk-informed performance based (RIPB) evaluations of nuclear control systems. Every possible cyber threat which could lead to consequence is identified by simulating the unsafe control action sequences which transform digital harm into physical harm. Eliminating the simulation of complex digital cyber attack chains cuts out unnecessary computational overhead and focuses directly on the physics of cyber-physical attacks. This focus enables designers to make informed decisions which can entirely eliminate categories of cyber threats against advanced reactors through the physical nature of the plant design. This narrowing of cyber threat against nuclear power plants through the physics of the system is intended to make any remaining threat management and cost efficient. This is the goal of the Tiered Cyber Analysis (TCA) outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors. ARCADE has been custom developed to meet the demands of the rigorous analysis required in Tier 1 of the TCA, which forms the foundation of the TCA process. Currently, ARCADE is still under development, but has made significant leaps in capability. A pilot analysis on the opensource Asherah simulator was performed which demonstrated key functionality goals. The next stage of ARCADE development involves improvements to the applications which support the analysis system, and enabling the analysis system to utilize the full suite of unsafe control action simulations. Since the analysis method’s core functions are complete, validation of the analysis method will be started concurrent to the next development stages. The automated analysis ARCADE will provide can radically change the cybersecurity design process for advanced reactors, reducing the cost of security implementation while enhancing cyber resilience. The pathway for ARCADE’s development to this goal has become much clearer. The majority of technical hurdles have been cleared, and the remaining development needs have been solidified. ARCADE is now capable of assisting the advanced reactor design process and directly support advanced reactor industry RIPB practices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cybersecurity Center for Offshore Wind Energy (Final Project Report)

This project establishes a Cybersecurity Center for Offshore Wind Energy with the objective of designing and operating a cyber-physical testbed for wind energy farms (WEFs) that enables comprehensive cybersecurity research. The testbed incorporates a Supervisory Control and Data Acquisition (SCADA) system connected to turbine models via industrial-grade programmable logic controllers (PLCs) and remote terminal units (RTUs). It supports side-channel data acquisition, implementation and analysis of various cyberattack scenarios, and development of attack detection, mitigation, and best-practice guidance tailored to wind energy systems. During the project, the team expanded the number and fidelity of mathematical turbine models (MTMs), integrated these models with SCADA infrastructure, and deployed a scaled physical turbine and associated sensors. High-resolution operational and side-channel data streams were collected and used to refine machine-learning (ML)-based attack detection systems and to extend the WindCRAFT framework to multi-turbine threat scenarios. The project demonstrated a realistic, scalable environment for evaluating cyber threats, validated attack detection approaches using enriched datasets, and identified new multi-turbine and inter-turbine communication attack vectors. The resulting testbed, models, and security mechanisms provide a foundation for ongoing R&D and deployment of cyber-resilient offshore wind energy systems.

17 WIND ENERGY↗

Edge ML for CAN bus intrusion detection in AVs

Autonomous Vehicles (AVs) are revolutionizing transportation, but their reliance on interconnected cyber-physical systems exposes them to unprecedented cybersecurity risks. This study addresses the critical challenge of detecting real-time cyber intrusions in self-driving vehicles by leveraging a dataset from the Udacity self-driving car project. We simulate four high-impact attack vectors, Denial of Service (DoS), spoofing, replay, and fuzzy attacks, by injecting noise into spatial features (e.g., bounding box coordinates) to replicate adversarial scenarios. We develop and evaluate two lightweight neural network architectures (NN-1 and NN-2) alongside a logistic regression baseline (LG-1) for intrusion detection. The models achieve exceptional performance, with NN-2 attaining an AUC score of 93.15% and 93.15% accuracy, demonstrating their suitability for edge deployment in AV environments. Through explainable AI techniques, we uncover unique forensic fingerprints of each attack type, such as spatial corruption in fuzzy attacks and temporal anomalies in replay attacks, offering actionable insights for feature engineering and proactive defense. Visual analytics, including confusion matrices, ROC curves, and feature importance plots, validate the models' robustness and interpretability. This research sets a new benchmark for AV cybersecurity, delivering a scalable, field-ready toolkit for Original Equipment Manufacturers (OEMs) and policymakers. By aligning intrusion fingerprints with SAE J3061 automotive security standards, we provide a pathway for integrating machine learning into safety-critical AV systems. Our findings underscore the urgent need for security-by-design AI, ensuring that AVs not only drive autonomously but also defend autonomously. This work bridges the gap between theoretical cybersecurity and life-preserving engineering, offering a leap toward safer, more secure autonomous transportation.

97 MATHEMATICS AND COMPUTING↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

alfalfa↗

Capabilities for Water Sector Infrastructure Resilience - Prioritizing RD&D in a Target Rich, Resource Poor Sector

WSTB & Water Sector Security Program Expansion Objective: Incubate and shepherd a public-private consortium of joint seal US government sponsors and industry stakeholders to build out industrial control system (ICS) and operational technology (OT) architecture of the Idaho National Laboratory (INL) Water Security Test Bed (WSTB) asset to enable research, testing, and cyber workforce training related to evolving cyber-physical and physical vulnerabilities and threats in the water sector.

99 - GENERAL AND MISCELLANEOUS↗