Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenics & vacuum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Solid-State Thermodynamic Vent System (STVS) for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellant condition. By exploiting the vacuum-induced cryocooling (VIC) potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger (HX) can expel some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. Testing proved the effectiveness of the concept by reducing the liquid nitrogen (LN 2 ) boiloff rate and tank pressure by roughly 70% and 77%, respectively, during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Cryogenic Fluid↗

Cryo Testing of tbe James Webb Space Telescope's Integrated Science Instrument Module

The Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope will be integrated and tested at the Environmental Test Facilities at Goddard Space Flight Center (GSFC). The cryogenic thermal vacuum testing of the ISIM will be the most difficult and problematic portion of the GSFC Integration and Test flow. The test is to validate the coupled interface of the science instruments and the ISIM structure and to sufficiently stress that interface while validating image quality of the science instruments. The instruments and the structure are not made from the same materials and have different CTE. Test objectives and verification rationale are currently being evaluated in Phase B of the project plan. The test program will encounter engineering challenges and limitations, which are derived by cost and technology many of which can be mitigated by facility upgrades, creative GSE, and thorough forethought. The cryogenic testing of the ISIM will involve a number of risks such as the implementation of unique metrology techniques, mechanical, electrical and optical simulators housed within the cryogenic vacuum environment. These potential risks are investigated and possible solutions are proposed.

VanCampen, Julie↗

Refurbishment of the Jet Propulsion Laboratory's Large Space Simulator

The JPL large space simulator has recently undergone a major refurbishment to restore and enhance its capabilities to provide high fidelity space simulation. The nearly completed refurbishment has included upgrading the vacuum pumping system by replacing old oil diffusion pumps with new cryogenic and turbomolecular pumps; modernizing the entire control system to utilize computerized, distributed control technology; replacing the Xenon arc lamp power supplies with new upgraded units; refinishing the primary collimating mirror; and replacing the existing integrating lens unit and the fused quartz penetration window.

JPL space simulator mirror cryopump solar simulati↗

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE↗

FIRST Mirror Review

As part of a JPL-funded effort to develop lightweight telescope technology suitable for far-infrared astronomy, COI designed and fabricated a spherical, f/1, 2-meter aperture prototype primary mirror using solely graphite/resin composite materials. To assess the performance of this technology, optical metrology of the mirror surface was performed from ambient to an intended operational temperature for IR-telescopes of 70K. Testing was performed horizontally in a cryogenic vacuum chamber at Arnold AFB, Tennessee. The test design had to accommodate requirements for rapid and uniform cooling across the optic, passivation of the ambient vibrational environment, and de-coupling of the mirror from the thermal strain of the test stand. An IR-wavelength phase shifting interferometer (PSI) was the primary instrument used to measure the mirror surface. From an initial surface figure of 2.1 microns RMS at ambient, a modest 3.9 microns of additional RMS surface error was induced at 70K. The thermally induced error was dominated by low-order deformations, of the type that could easily be corrected with secondary or tertiary optics. In addition to exceptional thermal stability, the mirror exhibited no measurable hysteresis between both ambient and cryo measurements.

Dodson, Kelly↗

Cryogenic (70K) measurement of an all-composite 2-meter diameter mirror

The Herschel Space observatory (formerly known as FIRST) consists of a 3.5 m space telescope. In order to develop lightweight telescope technology suitable for this mission, COI designed and fabricated aspherical, f/1 2 m aperture prototype primary mirror using solely carbon fiber reinforced polypmer (CFR) materials. To assess the performance of this technology, optical metrology of the mirror surface was performed from ambient to an intended operational temperature for IR-telescopes of 70K. Testing was performed horizontally in a cryogenic vacuum chamber at Arnold Engineering Development Center (AEDC), Tennessee.

lightweight mirrors cryogenic testing composite ma↗

Low cost microminiature refrigerators for large unit volume applications

Photolithographic techniques were employed to fabricate small Joule-Thomson refrigerators in laminated substrates. The gas passages of a J-T refrigerator are formed by etching channels as narrow as 50 microns and as shallow as 5 microns in glass plates which are laminated together. Circular refrigerators on the order of 1.5 centimeters in diameter and .75 millimeters thick were produced which cool down to cryogenic temperatures in a few seconds, using Argon or Nitrogen, with no vacuum or radiation insulation. Smaller refrigerators are developed for both faster cooldown and low refrigeration capacity applications. By using this technology, custom refrigerators can be designed to meet specific application requirements.

Duboc, R. M., Jr.↗

Reliable Ignition of LOX-LCH4 Propellants

No cryogenic Reaction Control System (RCS) has ever flown in space. Cryogenic propellants are baselined by HLS and CLPS partners and are the key use case for future ISRU manufactured propellants. A reliable LOX/LCH 4 RCS is an enabling technology for human Lunar and Mars exploration. In previous thermal vacuum (<275 F, <10 torr) testing at NASA GRC Plum Brook, the team uncovered anomalous LOX/LCH4 engine ignition phenomena where flame kernels quenched at these ultra cold hardware temperatures, leading to many pulses where the engines would not light. In 2022, the project was able to recreate the no light condition with an upgraded Frost-Mint test stand at JSC. This project implemented test stand improvements and procured propellants and follow on engine components for a hot fire campaign beginning in November 2024 which will attempt to ignite the RCS engine at ultra cold vacuum conditions by modifying the engine mixture ratio. New modeling techniques were implemented to account for past no lights and are an enabling method to make lunar surface go no go predictions based on hardware conditions. This was enabled by significant improvements to the Frost Mint system, which reduced moisture build up and leaks, increased propellant availability, leading to more attempts at thermal vacuum hot-fires.

Propulsion↗

Microgravity Science Glovebox (MSG), Space Science's Past, Present and Future Aboard the International Space Station (ISS)

The Microgravity Science Glovebox (MSG) is a double rack facility aboard the International Space Station (ISS), which accommodates science and technology investigations in a "workbench' type environment. The MSG has been operating on the ISS since July 2002 and is currently located in the US Laboratory Module. In fact, the MSG has been used for over 10,000 hours of scientific payload operations and plans to continue for the life of ISS. The facility has an enclosed working volume that is held at a negative pressure with respect to the crew living area. This allows the facility to provide two levels of containment for small parts, particulates, fluids, and gases. This containment approach protects the crew from possible hazardous operations that take place inside the MSG work volume and allows researchers a controlled pristine environment for their needs. Research investigations operating inside the MSG are provided a large 255 liter enclosed work space, 1000 watts of dc power via a versatile supply interface (120, 28, + 12, and 5 Vdc), 1000 watts of cooling capability, video and data recording and real time downlink, ground commanding capabilities, access to ISS Vacuum Exhaust and Vacuum Resource Systems, and gaseous nitrogen supply. These capabilities make the MSG one of the most utilized facilities on ISS. MSG investigations have involved research in cryogenic fluid management, fluid physics, spacecraft fire safety, materials science, combustion, and plant growth technologies. Modifications to the MSG facility are currently under way to expand the capabilities and provide for investigations involving Life Science and Biological research. In addition, the MSG video system is being replaced with a state-of-the-art, digital video system with high definition/high speed capabilities, and with near real-time downlink capabilities. This paper will provide an overview of the MSG facility, a synopsis of the research that has already been accomplished in the MSG, and an overview of the facility enhancements that will shortly be available for use by future investigators.

Spivey, Reggie↗

CRYogenic Orbital TEstbed Ground Test Article Thermal Analysis

The purpose of this study was to anchor thermal and fluid system models to CRYOTE ground test data. The CRYOTE ground test artide was jointly developed by Innovative Engineering Solutions, United Launch Alliance and NASA KSC. The test article was constructed out of a titanium alloy tank, Sapphire 77 composite skin (similar to G10), an external secondary payload adapter ring, thermal vent system, multi layer insulation and various data acquisition instrumentation. In efforts to understand heat loads throughout this system, the GTA (filled with liquid nitrogen for safety purposes) was subjected to a series of tests in a vacuum chamber at Marshall Space Flight Center. By anchoring analytical models against test data, higher fidelity thermal environment predictions can be made for future flight articles which would eventually demonstrate critical cryogenic fluid management technologies such as system chilldown, transfer, pressure control and long term storage. Significant factors that influenced heat loads included radiative environments, multi-layer insulation performance, tank fill levels and pressures and even contact conductance coefficients. This report demonstrates how analytical thermal/fluid networks were established and includes supporting rationale for specific thermal responses.

Piryk, David↗

Recent Ground Hold and Rapid Depressurization Testing of Multilayer Systems

In the development of flight insulation systems for large cryogenic orbital storage (spray on foam and multilayer insulation), testing need include all environments that are experienced during flight. While large efforts have been expended on studying, bounding, and modeling the orbital performance of the insulation systems, little effort has been expended on the ground hold and ascent phases of a mission. Historical cryogenic in-space systems that have flown have been able to ignore these phases of flight due to the insulation system being within a vacuum jacket. In the development phase of the Nuclear Mars Vehicle and the Shuttle Nuclear Vehicle, several insulation systems were evaluated for the full mission cycle. Since that time there had been minimal work on these phases of flight until the Constellation program began investigating cryogenic service modules and long duration upper stages. With the inception of the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, a specific need was seen for the data and as such, several tests were added to the Cryogenic Boil-off Reduction System liquid hydrogen test matrix to provide more data on a insulation system. Testing was attempted with both gaseous nitrogen (GN2) and gaseous helium (GHe) backfills. The initial tests with nitrogen backfill were not successfully completed due to nitrogen liquefaction and solidification preventing the rapid pumpdown of the vacuum chamber. Subsequent helium backfill tests were successful and showed minimal degradation. The results are compared to the historical data.

Space Environment Simulation↗

Thermal Performance of Low Layer Density Multilayer Insu1ation Using Liquid Nitrogen

In order to support long duration cryogenic propellant storage, the Cryogenic Fluid Management (CFM) Project of the Exploration Technology Development Program (ETDP) is investigating the long duration storage propertie$ of liquid methane on the lunar surface. The Methane Lunar Surface Thermal Control (MLSTC) testing is using a tank of the approximate dimensions of the Altair ascent tanks inside of a vacuum chamber to simulate the environment in low earth orbit and on the lunar surface. The thermal performance testing of multilayer insulation (MLI) coupons that are fabricated identically to the tank applied insulation is necessary to understand the performance of the blankets and to be able to predict the performance of the insulation prior to testing. This coupon testing was completed in Cryostat-100 at the Cryogenics Test Laboratory. The results showed the properties of the insulation as a function of layer density, number of layers, and warm boundary temperature. These results aid in the understanding of the performance parameters o fMLI and help to complete the body of literature on the topic.

Johnson, Wesley L.↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗

Analytical techniques and instrumentation, a compilation

Procedures for conducting materials tests and structural analyses of aerospace components are presented as a part of the NASA technology utilization program. Some of the subjects discussed are as follows: (1) failures in cryogenic tank insulation, (2) friction characteristics of graphite and graphite-metal combinations, (3) evaluation of polymeric products in thermal-vacuum environment, (4) erosion of metals by multiple impacts with water, (5) mass loading effects on vibrated ring and shell structures, (6) nonlinear damping in structures, and (7) method for estimating reliability of randomly excited structures.

Source record↗

An Overview of the Microgravity Science Glovebox (MSG) Facility and the Research Performed in the MSG on the International Space Station (ISS)

The Microgravity Science Glovebox (MSG) is a rack facility aboard the International Space Station (ISS) designed for investigation handling. The MSG was built by the European Space Agency (ESA) which also provides sustaining engineering support for the facility. The MSG has been operating on the ISS since July 2002 and is currently located in the US Laboratory Module. The unique design of the facility allows it to accommodate science and technology investigations in a "workbench" type environment. The facility has an enclosed working volume that is held at a negative pressure with respect to the crew living area. This allows the facility to provide two levels of containment for small parts, particulates, fluids, and gases. This containment approach protects the crew from possible hazardous operations that take place inside the MSG work volume. Research investigations operating inside the MSG are provided a large 255 liter enclosed work space, 1000 watts of dc power via a versatile supply interface (120, 28, +/- 12, and 5 Vdc), 1000 watts of cooling capability, video and data recording and real time downlink, ground commanding capabilities, access to ISS Vacuum Exhaust and Vacuum Resource Systems, and gaseous nitrogen supply. These capabilities make the MSG one of the most utilized facilities on ISS. The MSG has been used for over 14500 hours of scientific payload operations. MSG investigations involve research in cryogenic fluid management, fluid physics, spacecraft fire safety, materials science, combustion, plant growth, and life support technology. The MSG facility is operated by the Payloads Operations Integration Center at Marshall Space flight Center. Payloads may also operate remotely from different telescience centers located in the United States and Europe. The investigative Payload Integration Manager (iPIM) is the focal to assist organizations that have payloads operating in the MSG facility. NASA provides an MSG engineering unit for payload developers to verify that their hardware is operating properly before actual operation on the ISS. This paper will provide an overview of the MSG facility, a synopsis of the research that has already been accomplished in the MSG, and an overview of video and biological upgrades.

Jordan, Lee P.↗

An Overview of the Microgravity Science Glovebox (MSG) Facility and the Research Performed in the MSG on the International Space Station (ISS)

The Microgravity Science Glovebox (MSG) is a double rack facility aboard the International Space Station (ISS) designed for investigation handling. The MSG has been operating on the ISS since July 2002 and is currently located in the Columbus Laboratory Module. The unique design of the facility allows it to accommodate science and technology investigations in a workbench type environment. The facility has an enclosed working volume that is held at a negative pressure with respect to the crew living area. This allows the facility to provide two levels of containment for small parts, particulates, fluids, and gases. This containment approach protects the crew from possible hazardous operations that take place inside the MSG work volume. Research investigations operating inside the MSG are provided a large 255 liter enclosed work space, 1000 watts of dc power via a versatile supply interface (120, 28, +/- 12, and 5 Vdc), 1000 watts of cooling capability, video and data recording and real time downlink, ground commanding capabilities, access to ISS Vacuum Exhaust and Vacuum Resource Systems, and gaseous nitrogen supply. These capabilities make the MSG one of the most utilized facilities on ISS. In fact, the MSG has been used for over 5000 hours of scientific payload operations. MSG investigations involve research in cryogenic fluid management, fluid physics, spacecraft fire safety, materials science, combustion, plant growth, and life support technologies. MSG is an ideal platform for science investigations and research required to advance the technology readiness levels (TRLs) applicable to the Constellation Program. This paper will provide an overview of the MSG facility, a synopsis of the research that has already been accomplished in the MSG, an overview of future investigations currently planned for operation in the MSG, and potential applications of MSG investigations that can provide useful data to the Constellation Program. In addition, this paper will address the role of the MSG facility in the ISS National Lab.

Spivey, Reggie↗

Fast optical transport of ultracold molecules over long distances

Abstract Optically trapped laser-cooled polar molecules hold promise for new science and technology in quantum information and quantum simulation. Large numerical aperture optical access and long trap lifetimes are needed for many studies, but these requirements are challenging to achieve in a magneto-optical trap (MOT) vacuum chamber that is connected to a cryogenic buffer gas beam source, as is the case for all molecule laser cooling experiments so far. Long distance transport of molecules greatly eases fulfilling these requirements as molecules are placed into a region separate from the MOT chamber. We realize a fast transport method for ultracold molecules based on an electronically focus-tunable lens combined with an optical lattice. The high transport speed is achieved by the 1D red-detuned optical lattice, which is generated by interference of a focus-tunable laser beam and a focus-fixed laser beam. Efficiency of 48(8)% is realized in the transport of ultracold calcium monofluoride (CaF) molecules over 46 cm distance in 50 ms, with a moderate heating from 32(2) μ K to 53(4) μ K. Positional stability of the molecular cloud allows for stable loading of an optical tweezer array with single molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗