At least 55 records · Page 3

Parallel Analog-to-Digital Image Processor

Proposed integrated-circuit network of many identical units convert analog outputs of imaging arrays of x-ray or infrared detectors to digital outputs. Converter located near imaging detectors, within cryogenic detector package. Because converter output digital, lends itself well to multiplexing and to postprocessing for correction of gain and offset errors peculiar to each picture element and its sampling and conversion circuits. Analog-to-digital image processor is massively parallel system for processing data from array of photodetectors. System built as compact integrated circuit located near local plane. Buffer amplifier for each picture element has different offset.

Lokerson, D. C.↗

Projected sensitivity of the SuperCDMS SNOLAB experiment

SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤ 10 GeV/c^2) that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~1×10^-43 cm^2 for a dark matter particle mass of 1 GeV/c^2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H-3 and naturally occurring Si-32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1 GeV/c^2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5 GeV/c^2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.

Agnese, R.↗

AMoRE: Collaboration for searches for the neutrinoless double-beta decay of the isotope of {sup 100}Mo with the aid of {sup 40}Ca{sup 100}MoO{sub 4} as a cryogenic scintillation detector

The AMoRE (Advanced Mo based Rare process Experiment) Collaboration is planning to employ {sup 40}Ca{sup 100}MoO{sub 4} single crystals as a cryogenic Scintillation detector for studying the neutrinoless double-beta decay of the isotope {sup 100}Mo. A simultaneous readout of phonon and scintillation signals is performed in order to suppress the intrinsic background. The planned sensitivity of the experiment that would employ 100 kg of {sup 40}Ca{sup 100}MoO{sub 4} over five years of data accumulation would be T{sub 1/2}{sup 0{nu}} = 3 Multiplication-Sign 10{sup 26} yr, which corresponds to values of the effective Majorana neutrino mass in the range of Left-Pointing-Angle-Bracket m{sub {nu}} Right-Pointing-Angle-Bracket {approx} 0.02-0.06 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of time-dependent internal charge amplification in a planar germanium detector at cryogenic temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 min after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keVγ rays from a 241 Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold (< 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An in-situ movable calibration source for cryogenic particle detectors

A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for cryogenic dark matter detectors. Data taken by scanning a calibration source across multiple radial positions of a prototype dark matter detector demonstrated its functionality. Construction, heat load, and operation of the device are discussed, as is the effect of the motor on the detector operation. A sample dataset taken over multiple positions of a SuperCDMS detector is presented as an example of the utility of such a device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c2) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c2 compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4×10-42 cm2 at 5 GeV/c2, a factor of ~2.5 improvement over the previous CDMSlite result.

Agnese, R↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Inner Veto for Improved SuperCDMS SNOLAB Dark Matter Search Sensitivity. Final Report

The goal of this project was to develop and study a new geometry of cryogenic detector that could act as an active veto surrounding a smaller, inner cryogenic detector. This drastically reduces the background event rates, enabling more effective rare event searches. An annular germanium detector was fabricated with athermal phonon sensors and successfully tested. A threshold of better than 10keV was desired; 4keV was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CUPID-0: the first array of enriched scintillating bolometers for 0$\nu \beta \beta$ decay investigations

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay (0$\nu \beta \beta$). CUPID0 aims at measuring a background index in the region of interest (RoI) for 0$\nu \beta \beta$ at the level of 10 -3 counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Search for Low-mass Dark Matter and an Examination and Reduction of the Uncertainty due to the Photoelectric Absorption Cross Section using a Cryogenic Silicon Detector with Single-charge Sensitivity

Many astrophysical observations point to the abundant existence of dark matter (DM) in the universe composed of particles beyond the Standard Model. However despite numerous experiments using different techniques, DM particles have yet to be directly observed. The Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment will employ silicon and germanium crystal detectors operated at temperatures as low as 15~mK to probe DM interactions using phonon and ionization signals. Recently, R\&D; facilities have developed gram-sized high-voltage eV-scale (HVeV) silicon detectors that achieve single-electron-hole-pair resolution. By probing effective DM-electron interactions, these devices can be used for searches of low-mass DM candidates.This dissertation presents a DM search experiment known as HVeV Run~2 that employs a second-generation HVeV detector operated in an above-ground laboratory at Northwestern University (IL, USA). Energy spectra are obtained from a blind analysis with 0.39 and 1.2\,g-days of exposure with the detector biased at 60 and 100\,V, respectively. The 0.93~gram detector achieves a 3\,eV phonon energy resolution, corresponding to a world-leading charge resolution of 3\,\% of a single electron-hole pair for a detector bias of 100\,V. With charge carrier trapping and impact ionization effects incorporated into the DM signal models, the resulting exclusion limits are reported for inelastic DM-electron scattering for DM masses from 0.5--$10^{4}$\,MeV$/c^{2}$; in the mass range from 1.2--50\,eV$/c^{2}$ the limits for dark photon and axion-like particle absorption are reported.Several DM search experiments, including HVeV Run~2, are sensitive to low-mass DM candidates that rely on the temperature-dependent photoelectric absorption cross section of silicon. However discrepancies in the underlying literature data result in dominating systematic uncertainties on the DM exclusion limits. In order to reduce these systematic uncertainties, this dissertation presents a novel method of making a direct, low-temperature measurement of the photoelectric absorption cross section of silicon at energies near the band gap (1.2--2.8\,eV).

Wilson, Matthew James↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Performance of the first 150 mm diameter Cryogenic silicon ionization detectors with contact-free electrodes

Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of 33 mm, are planned for use by the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at SNOLAB, Canada. Still larger individual detectors are being investigated to scale up the sensitive mass of future experiments. We present here the first results of testing two prototype 150 mm diameter silicon ionization detectors. The detectors are 25 mm and 33 mm thick with masses 1.7 and 2.2 times larger than those currently planned for SuperCDMS. These devices were operated with contact-free bias electrodes to minimize leakage currents which currently limit operation at high bias voltages. The results show promise for the use of such technologies in solid state cryogenic detectors.

150 mm↗

Study of Pile-Up Effects in Decay Energy Spectroscopy

Pile-up is an unavoidable complication for cryogenic detectors with relatively large heat capacities and slow rise time, such as systems for decay energy spectroscopy employing large Au absorbers. We have simulated the spectral response of such slow cryogenic detectors using Monte-Carlo algorithms to investigate the effects of pile-up on absolute and relative activity measurements. We focus on the impact of non-distinguishable pile-up that occurs when the rising edges of two waveforms originating from different events overlap in time and are interpreted as a single event. This effect can not be readily identified and corrected in experimental data. We investigated two representative cases of absolute decay counting and plutonium isotopic analysis and find that pile-up can distort the reconstruction of both the absolute and relative activities. This Monte-Carlo methodology quantifies of pile-up effects and provides a systematic methodology for calculating corrective factors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Autonomous Cryogenic Leak Detector for Improving Launch Site Operations

NASA, military, and commercial satellite users need launch services that are highly reliable, less complex, easier to test, and cost effective. This project has developed a tapered optical fiber sensor for detecting hydrogen. The invention involves incorporating chemical indicators on the tapered end of an optical fiber using organically modified silicate nanomaterials. The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and qualify various mission-critical chemicals. Historically, hydrogen, helium, nitrogen, oxygen, and argon are the first five gases of HGDL focus. The use of these cryogenic fluids in the area of propulsion offers challenges. Due to their extreme low temperatures, these fluids induce contraction of the materials they contact, a potential cause of leakage. Among them, hydrogen is of particular concern. Small sensors are needed in multiple locations without adding to the structural weight. The most vulnerable parts of the engine are the connection flanges on the transfer lines, which have to support cycles of large thermal amplitude. The thermal protection of the engine provides a closed area, increasing the likelihood of an explosive atmosphere. Thus, even a small leak represents an unacceptable hazardous condition during loading operations, in flight, or after an aborted launch. Tapered fibers were first fabricated from 1/1.3-mm core/cladding (silica/ plastic) optical fibers. Typically a 1-ft (approx. 30- cm) section of the 1-mm fiber is cut from the bundle and marked with a pen into five 2-.-in. (.5.7-cm) sections. A propane torch is applied at every alternate mark to burn the jacket and soften the glass core. While the core is softening, the two ends of the fiber are pulled apart slowly to create fine tapers of .- to .-in. (.6- to 12-mm) long on the 1-mm optical fiber. Following this, the non-tapered ends of the fibers are polished to a 0.3-micron finish. Then these fibers were coated with indicators sensitive to hydrogen. The tapered hydrogen detection system with its unique flexibility is the only system that can be placed in many locations inside the vehicles and detect the exact location of leaks, saving millions of dollars for launch vehicle industries.

Goswami, Kisholoy↗

Improved relay optical element for spectroradiometer using cryogenically cooled detector

By coating half of one element in the relay optical system of a spectroradiometer with a very high emissivity paint, the effect of the reflected radiation from the back of the filter wheel is eliminated optically. This causes the detector to view a constant level of radiation, regardless of how the reflectivity of the back of the filter wheel changes.

Kraemer, A. R.↗

High-Tc thermal bridges for space-borne cryogenic infrared detectors

The potential for using high-temperature superconductive elements, screen-printed onto ceramic substrates, as thermal bridges to replace the currently employed manganin wires is studied at NASA-LaRC. Substrate selection is considered to be the most critical parameter in device production. Due to the glass-like thermal behavior of yttria-stabilized-zirconia (YSZ) and fused silica substrates, these materials are found to reduce the heat load significantly. The estimated thermal savings for superconductive leads printed onto YSZ or fused silica substrates range from 6 to 14 percent.