Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Crack initiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Statistical investigation of fatigue crack initiation and growth around chamfered rivet holes in Alclad 2024 T3 as affected by corrosion

In panel specimens with rivet holes cracks initiate in the blunted knife edge of the chamfered rivet hole and propagate inward as well as along the hole. The fatigue lifetime to dominant crack information was defined as the number of cycles, N500 micrometer, to formation of a 500 micrometer long crack. Statistical data on N500 micrometer and on crack propagation after N500 micrometer were obtained for a large number of uncorroded specimens and specimens corroded in an ASTM B 117 salt spray. Considerable variation in N500 micrometer and crack propagation behavior was observed from specimen to specimen of the same nominal geometry with chamfered rivet holes increased the probability for both early formation and later formation of a propagating 500 micrometer fatigue crack. The growth of fatigue cracks after 500 micrometer size was little affected by prior salt spray.

Fadragas, M. I.↗

Crack initiation and growth toughness of an aluminum metal-matrix composite

The effects of systematic changes in matrix microstructure on crack initiation and growth toughnesses were determined on an Al-Zn-Mg-Cu alloy containing 0, 15, 20 percent by volume of SiC particulates. Materials were heat treated to underaged (UA) and overaged (OA) conditions of equivalent matrix microhardness and flow stress. Although both the fracture initiation and growth toughnesses, as measured by JIc and tearing modulus, were similar for the unreinforced materials in the UA and OA conditions, significant effects of microstructure on both JIc and tearing modulus were observed in the composites. SEM and TEM observations of fracture paths in the two conditions are utilized to rationalize these observations in light of existing theories of ductile fracture propagation.

Manoharan, M.↗

High Cycle Fatigue Crack Initiation Study of Case Blade Alloy Rene 125

This study was conducted in order to investigate and document the high cycle fatigue crack initiation characteristics of blade alloy Rene 125 as cast by three commercially available processes. This alloy is typically used in turbine blade applications. It is currently being considered as a candidate alloy for high T3 compressor airfoil applications. This effort is part of NASA's Advanced Subsonic Technology (AST) program which aims to develop improved capabilities for the next generation subsonic gas turbine engine for commercial carriers. Wrought alloys, which are customarily used for airfoils in the compressor, cannot meet the property goals at the higher compressor exit temperatures that would be required for advanced ultra-high bypass engines. As a result cast alloys are currently being considered for such applications. Traditional blade materials such as Rene 125 have the high temperature capabilities required for such applications. However, the implementation of cast alloys in compressor airfoil applications where airfoils are typically much thinner does raise some issues of concern such as thin wall castability, casting cleaningness, and susceptibility to high-cycle fatigue (HCF) loading.

Kantzos, P.↗

Multiscale fatigue crack initiation in hierarchical additively manufactured alloys

Bioinspired hierarchical microstructures offer a route toward engineered fatigue resistance in additively manufactured alloys. However, it remains unclear how discrete structural constituents independently govern damage accumulation, particularly during the critical fatigue initiation regime where short cracks strongly interact with local microstructure. Here, we investigate multiscale fatigue initiation in a dual-phase, nanolamellar AlCoCrFeNi 2.1 high-entropy alloy. By comparing microscale specimens that isolate the nanolamellar structure against macroscale specimens containing the full melt-pool architecture, we identify size-dependent fatigue initiation mechanisms. We find that failure is dictated by nanolamellar interfaces at the microscale, whereas mesoscale melt pool boundaries serve to initiate fatigue at the macroscale. This mechanistic shift is accompanied by a transition from macroscale quasi-brittle failure to microscale plasticity-driven crack extension. Our results provide a physical framework for understanding how structural hierarchy governs the transition from discrete microstructural deformation to continuum fatigue fracture behavior, informing the design of damage-tolerant, additively manufactured alloys.

36 MATERIALS SCIENCE↗

Prediction of matrix fatigue crack initiation in notched SCS-6/Ti-15-3 metal matrix composites

Several lay-ups of SCS-6/Ti-15-3 metal matrix composites were tested in either a center hole or a double edge notched geometry. At different cyclic strss levels, the number of cycles required to develop matrix fatigue cracks at the notches was recorded. A fatigue strat-life curve was developed for the Ti-15-3 matrix material. This modified parameter predicted the number of cycles required for matrix crack initiation at the notches. The predictions were in good agreement with the experimental data.

Hillberry, B. M.↗

Prediction of matrix fatigue crack initiation in notched SCS-6/Ti-15-3 metal matrix composites

Several lay-ups of SCS-6/Ti-15-3 metal matrix composites were tested in either a center hole or a double edge notched geometry. At different cyclic stress levels, the number of cycles required to develop matrix fatigue cracks at the notches was recorded. A fatigue strat-life curve was developed for the Ti-15-3 matrix material. This modified parameter predicted the number of cycles required for matrix crack initiation at the notches. The predictions were in good agreement with the experimental data.

Hillberry, Benjamin M.↗

Application of Self Nulling Eddy Current Probe Technique to the Detection of Fatigue Crack Initiation and Control of Test Procedures

A major part of fracture mechanics is concerned with studying the initiation and propagation of fatigue cracks. This typically requires constant monitoring of crack growth during fatigue cycles and the knowledge of the precise location of the crack tip at any given time. One technique currently available for measuring fatigue crack length is the Potential Drop method. The method, however, may be inaccurate if the direction of crack growth deviates considerably from what was assumed initially or the curvature of the crack becomes significant. Another popular approach is to optically view the crack using a high magnification microscope, but this entails a person constantly monitoring it. The present proposed technique uses an automated scheme, in order to eliminate the need for a person to constantly monitor the experiment. Another technique under development elsewhere is to digitize an optical image of the test specimen surface and then apply a pattern recognition algorithm to locate the crack tip. A previous publication showed that the self nulling eddy current probe successfully tracked a simulated crack in an aluminum sample. This was the impetus to develop an online real time crack monitoring system. An automated system has been developed which includes a two axis scanner mounted on the tensile testing machine, the probe and its instrumentation and a personal computer (PC) to communicate and control all the parameters. The system software controls the testing parameters as well as monitoring the fatigue crack as it propagates. This paper will discuss the experimental setup in detail and demonstrate its capabilities. A three dimensional finite element model is utilized to model the magnetic field distribution due to the probe and how the probe voltage changes as it scans the crack. Experimental data of the probe for different samples under zero load, static load and high cycle fatigue load will be discussed. The final section summarizes the major accomplishments of the present work, the elements of the future R&D needs and the advantages and disadvantages of using this system in the laboratory and field.

Namkung, M.↗

Finite-element analysis of initiation, stable crack growth and instability using a crack-tip-opening displacement criterion

An elastic-plastic (incremental and small strain) finite element analysis was used with a crack growth criterion to study crack initiation, stable crack growth, and instability under monotonic loading to failure of metallic materials. The crack growth criterion was a critical crack-tip-opening displacement (CTOD) at a specified distance from the crack tip, or equivalently, a critical crack-tip-opening angle (CTOA). Whenever the CTOD (or CTOA) equaled or exceeded a critical value, the crack was assumed to grow. Single values of critical CTOD were used in the analysis to model crack initiation, stable crack growth, and instability for 7075-T651 and 2024-T351 aluminum alloy compact specimens. Calculated and experimentally measured CTOD values at initiation agreed well for both aluminum alloys. These critical CTOD values were also used to predict failure loads on center-crack tension specimens and a specially-designed three-hole-crack tension specimen made of the two aluminum alloys and of 304 stainless steel. All specimens were 12.7 mm thick. Predicted failure loads for 7075-T651 aluminum alloy and 304 stainless steel specimens were generally within + or - 15 percent of experimental failure loads, whereas the predicted failure loads for 2024-T351 aluminum alloy specimens were generally within + or - 5 percent of the experimental loads.

Newman, J. C., Jr.↗

Observations of fatigue crack initiation and damage growth in notched titanium matrix composites

The purpose was to characterize damage initiation and growth in notched titanium matrix composites at room temperature. Double edge notched or center open hole SCS-6/Ti-15-3 specimens containing 0 deg plies or containing both 0 and 90 deg plies were fatigued. The specimens were tested in the as-fabricated (ASF) and in heat-treated conditions. A local strain criterion using unnotched specimen fatigue data was successful in predicting fatigue damage initiation. The initiation stress level was accurately predicted for both a double edge notched unidirectional specimen and a cross-plied center hole specimen. The fatigue produced long multiple cracks growing from the notches. These fatigue cracks were only in the matrix material and did not break the fibers in their path. The combination of matrix cracking and fiber/matrix debonding appears to greatly reduce the stress concentration around the notches. The laminates that were heat treated showed a different crack growth pattern. In the ASF specimens, matrix cracks had a more tortuous path and showed considerable more crack branching. For the same specimen geometry and cyclic stress, the (0/90/0) laminate with a hole had far superior fatigue resistance than the matrix only specimen with a hole.

Naik, R. A.↗

Observations of fatigue crack initiation and damage growth in notched titanium matrix composites

The purpose was to characterize damage initiation and growth in notched titanium matrix composites at room temperature. Double edge notched or center open hole SCS-6/Ti-15-3 specimens containing 0 deg plies or containing both 0 and 90 deg plies were fatigued. The specimens were tested in the as-fabricated (ASF) and in heat-treated conditions. A local strain criterion using unnotched specimen fatigue data was successful in predicting fatigue damage initiation. The initiation stress level was accurately predicted for both a double edge notched unidirectional specimen and a cross-plied center hole specimen. The fatigue produced long multiple cracks growing from the notches. These fatigue cracks were only in the matrix material and did not break the fibers in their path. The combination of matrix cracking and fiber/matrix debonding appears to greatly reduce the stress concentration around the notches. The laminates that were heat treated showed a different crack growth pattern. In the ASF specimens, matrix cracks had a more tortuous path and showed considerable more crack branching. For the same specimen geometry and cyclic stress, the (0/90/0) laminate with a hole had far superior fatigue resistance than the matrix only specimen with a hole.

Naik, Rajiv A.↗

Effects of environmental variables on the crack initiation stages of corrosion fatigue of high strength aluminum alloys

Fatigue initiation in six aluminum alloys used in the aircraft industry was investigated. Cyclic loading superimposed on a constant stress was alternated with atmospheric corrosion. Tests made at different stress levels revealed that a residual stress as low as 39% of the yield strength caused stress corrosion cracking in some of the alloys. An atmospheric corrosion rate meter developed to measure the corrosivity of the atmosphere is described. An easily duplicated hole in the square test specimen with a self-induced residual stress was developed.

Poteat, L. E.↗

Fatigue damage accumulation in nickel prior to crack initiation

The accumulation of lattice defects during fatigue cycling of nickel was investigated by electrical resistivity measurements, positron annihilation lifetime spectroscopy and transmission electron microscopy. Dislocations and vacancy clusters were found to be the main defect types. During cycling of axial and flexural samples at constant load amplitude, the dislocations form a saturated structure early in the fatigue life. This saturated structure consists of a cellular dislocation matrix, in which persistent slip bands (PSBs) begin to operate after the saturation has been established. Vacancies and vacancy clusters are formed during fatigue as a consequence of repetitive dislocation glide in the PSB structure. When PSBs operate, the matrix is assumed to be dormant, allowing vacancies to accumulate preferentially in the PSBs. The increase in vacancy concentration then accounts for the monotonic accumulation of fatigue damage, which points to the importance of vacancy accumulation as a precursor to crack nucleation.

Grobstein, T. L.↗

High temperature constitutive and crack initiation modeling of coated single crystal superalloys

The purpose of this program is to develop life prediction models for anisotropic materials used in gas turbine airfoils. In the base portion of the program, two coated single crystal alloys are being tested. They are PWA 286 overlay coated and PWA 273 aluminide coated PWA 1480 and PWA 286 overlay coated Alloy 185. Viscoplastic constitutive models for these materials are also being developed to predict the cyclic stress-strain histories required for life prediction of the lab specimens and actual airfoil designs.

Meyer, Thomas G.↗