Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Coolants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Oscillating-Coolant Heat Exchanger

Devices useful in situations in which heat pipes inadequate. Conceptual oscillating-coolant heat exchanger (OCHEX) transports heat from its hotter portions to cooler portions. Heat transported by oscillation of single-phase fluid, called primary coolant, in coolant passages. No time-averaged flow in tubes, so either heat removed from end reservoirs on every cycle or heat removed indirectly by cooling sides of channels with another coolant. Devices include leading-edge cooling devices in hypersonic aircraft and "frost-free" heat exchangers. Also used in any situation in which heat pipe used and in other situations in which heat pipes not usable.

Scotti, Stephen J.

Numerical analysis of the hot-gas-side and coolant-side heat transfer in liquid rocket engine combustors

The objectives of this paper are to develop computational methods to predict the hot-gas-side and coolant-side heat transfer, and to use these methods in parametric studies to recommend optimized design of the coolant channels for regeneratively cooled liquid rocket engine combustors. An integrated numerical model which incorporates computational fluid dynamics (CFD) for the hot-gas thermal environment, and thermal analysis for the coolant channels, was developed. The mode was validated by comparing predicted heat fluxes with those of hot-firing test and industrial design methods. Parametric studies were performed to find a strategy for optimized combustion chamber coolant channel design.

Wang, T. S.

Numerical analysis of the hot-gas-side and coolant-side heat transfer in liquid rocket engine combustors

The objective of this paper are to develop a multidisciplinary computational methodology to predict the hot-gas-side and coolant-side heat transfer and to use it in parametric studies to recommend optimized design of the coolant channels for a regeneratively cooled liquid rocket engine combustor. An integrated numerical model which incorporates CFD for the hot-gas thermal environment, and thermal analysis for the liner and coolant channels, was developed. This integrated CFD/thermal model was validated by comparing predicted heat fluxes with those of hot-firing test and industrial design methods for a 40 k calorimeter thrust chamber and the Space Shuttle Main Engine Main Combustion Chamber. Parametric studies were performed for the Advanced Main Combustion Chamber to find a strategy for a proposed combustion chamber coolant channel design.

Wang, Ten-See

A hydrogen-oxygen rocket engine coolant passage design program (RECOP) for fluid-cooled thrust chambers and nozzles

The design of coolant passages in regeneratively cooled thrust chambers is critical to the operation and safety of a rocket engine system. Designing a coolant passage is a complex thermal and hydraulic problem requiring an accurate understanding of the heat transfer between the combustion gas and the coolant. Every major rocket engine company has invested in the development of thrust chamber computer design and analysis tools; two examples are Rocketdyne's REGEN code and Aerojet's ELES program. In an effort to augment current design capabilities for government and industry, the NASA Lewis Research Center is developing a computer model to design coolant passages for advanced regeneratively cooled thrust chambers. The RECOP code incorporates state-of-the-art correlations, numerical techniques and design methods, certainly minimum requirements for generating optimum designs of future space chemical engines. A preliminary version of the RECOP model was recently completed and code validation work is in progress. This paper introduces major features of RECOP and compares the analysis to design points for the first test case engine; the Pratt & Whitney RL10A-3-3A thrust chamber.

Tomsik, Thomas M.

A Heated Tube Facility for Rocket Coolant Channel Research

The capabilities of a heated tube facility used for testing rocket engine coolant channels at the NASA Lewis Research Center are presented. The facility uses high current, low voltage power supplies to resistively heat a test section to outer wall temperatures as high as 730 C (1350 F). Liquid or gaseous nitrogen, gaseous helium, or combustible liquids can be used as the test section coolant. The test section is enclosed in a vacuum chamber to minimize heat loss to the surrounding system. Test section geometry, size, and material; coolant properties; and heating levels can be varied to generate heat transfer and coolant performance data bases.

Green, James M.

Hot-Gas-Slide and Coolant-Side Heat Transfer in Liquid Rocket Engine Combustors

The objectives of this article are to develop a multidisciplinary, computational methodology to predict the hot-gas-side and coolant-side heat transfer in film cooling assisted, regeneratively cooled liquid rocket engine combustors, and to use it in parametric studies to recommend optimized design of the coolant channels for a developmental combustor. An integrated numerical model which incorporates computational fluid dynamics (CFD) for the hot-gas thermal environment, and thermal analysis for the liner and coolant channels, was developed. This integrated CFD/thermal model was validated by comparing predicted heat fluxes with those of hot-firing test and industrial design methods for a 40-k calorimeter thrust chamber and the Space Shuttle Main Engine main combustion chamber. Parametric studies were performed for the advanced main combustion chamber to find a strategy for a proposed coolant channel design.

Ten-see Wang

Effect on Gaseous Film Cooling of Coolant Injection Through Angled Slots and Normal Holes

A study was made to determine the effect of coolant injection angularity on gaseous film-cooling effectiveness. In the correlation of experimental data an effective injection angle was defined by a vector summation of the coolant and mainstream gas flows. The cosine of this angle was used as a parameter to empirically develop a corrective term to qualify a correlating equation presented in Technical Note D-130 that was limited to tangential injection of the coolant. Data were also obtained for coolant injection through rows of holes normal to the test plate. The slot correlating equation was adapted to fit these data by the definition of an effective slot height. An additional corrective term was then determined to correlate these data.

Papell, S. Stephen

Modeling Film-Coolant Flow Characteristics at the Exit of Shower-Head Holes

The coolant flow characteristics at the hole exits of a film-cooled blade are derived from an earlier analysis where the hole pipes and coolant plenum were also discretized. The blade chosen is the VKI rotor with three staggered rows of shower-head holes. The present analysis applies these flow characteristics at the shower-head hole exits. A multi-block three-dimensional Navier-Stokes code with Wilcox's k-omega model is used to compute the heat transfer coefficient on the film-cooled turbine blade. A reasonably good comparison with the experimental data as well as with the more complete earlier analysis where the hole pipes and coolant plenum were also gridded is obtained. If the 1/7th power law is assumed for the coolant flow characteristics at the hole exits, considerable differences in the heat transfer coefficient on the blade surface, specially in the leading-edge region, are observed even though the span-averaged values of h (heat transfer coefficient based on T(sub o)-T(sub w)) match well with the experimental data. This calls for span-resolved experimental data near film-cooling holes on a blade for better validation of the code.

Garg, Vijay K.

Assessment and Accommodation of Thermal Expansion of the Internal Active Thermal Control System Coolant During Launch to On-Orbit Activation of International Space Station Elements

The International Space Station (ISS) employs an Internal Active Thermal Control System (IATCS) comprised of several single-phase water coolant loops. These coolant loops are distributed throughout the ISS pressurized elements. The primary element coolant loops (i.e., US Laboratory module) contain a fluid accumulator to accommodate thermal expansion of the system. Other element coolant loops are parasitic (i.e., Airlock), have no accumulator, and require an alternative approach to insure that the system Maximum Design Pressure (MDP) is not exceeded during the Launch to Activation phase. During this time the element loop is a stand alone closed individual system. The solution approach for accommodating thermal expansion was affected by interactions of system components and their particular limitations. The mathematical solution approach was challenged by the presence of certain unknown or not readily obtainable physical and thermodynamic characteristics of some system components and processes. The purpose of this paper is to provide a brief description of a few of the solutions that evolved over time, a novel mathematical solution to eliminate some of the unknowns or derive the unknowns experimentally, and the testing and methods undertaken.

Edwards, J. Darryl

Assessment and Accommodation of Thermal Expansion of the Internal Active Thermal Control System Coolant During Launch to On-Orbit Activation of International Space Station Elements

The International Space Station (ISS) employs an Internal Active Thermal Control System (IATCS) comprised of several single-phase water coolant loops. These coolant loops are distributed throughout the ISS pressurized elements. The primary element coolant loops (i.e. U.S. Laboratory module) contain a fluid accumulator to accomodate thermal expansion of the system. Other element coolant loops are parasitic (i.e. Airlock), have no accumulator, and require an alternative approach to insure that the system maximum design pressure (MDP) is not exceeded during the Launch to Activation (LTA) phase. During this time the element loops is a stand alone closed system. The solution approach for accomodating thermal expansion was affected by interactions of system components and their particular limitations. The mathematical solution approach was challenged by the presence of certain unknown or not readily obtainable physical and thermodynamic characteristics of some system components and processes. The purpose of this paper is to provide a brief description of a few of the solutions that evolved over time, a novel mathematical solution to eliminate some of the unknowns or derive the unknowns experimentally, and the testing and methods undertaken.

Edwards, Darryl

An Improved Design for Air Removal from Aerospace Fluid Loop Coolant Systems

Aerospace applications with requirements for large capacity heat removal (launch vehicles, platforms, payloads, etc.) typically utilize a liquid coolant fluid as a transport media to increase efficiency and flexibility in the vehicle design. An issue with these systems however, is susceptibility to the presence of noncondensable gas (NCG) or air. The presence of air in a coolant loop can have numerous negative consequences, including loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and coolant blockage to remote systems. Hardware ground processing to remove this air is also cumbersome and time consuming which continuously drives recurring costs. Current systems for maintaining the system free of air are tailored and have demonstrated only moderate success. An obvious solution to these problems is the development and advancement of a passive gas removal device, or gas trap, that would be installed in the flight cooling system simplifying the initial coolant fill procedure and also maintaining the system during operations. The proposed device would utilize commercially available membranes thus increasing reliability and reducing cost while also addressing both current and anticipated applications. In addition, it maintains current pressure drop, water loss, and size restrictions while increasing tolerance for pressure increases due to gas build-up in the trap.

Ritchie, Stephen M. C.

New Hydrophilic, Composite Membranes for Air Removal from Water Coolant Systems

Liquid coolants are commonly used as thermal transport media to increase efficiency and flexibility in aerospace vehicle design. The introduction of gas bubbles into the coolant can have negative consequences, including: loss of centrifugal pump prime, irregular sensor readings, and blockage of coolant flow to remote systems. One solution to mitigate these problems is the development of a passive gas removal device, or gas trap, installed in the flight cooling system. In this study, a new hydrophilic, composite membrane has been developed for passage of the coolant fluid and retention of gas bubbles. The trapped bubbles are subsequently vented from the system by a thin, hydrophobic, microporous membrane. The original design for this work employed a homogeneous membrane that was susceptible to fouling and pore plugging. Spare gas traps of this variety have degraded during storage, and recreation of the membranes has been complicated due to problems with polymer duplication and property variations in the final membranes. In this work, replacements have been developed based on deposition of a hydrophilic polymer on the bore-side of a porous polyethylene (PE) tube. The tube provides excellent chemical and mechanical stability, and the hydrophilic layer provides retention of gas bubbles. Preliminary results have shown that intimate contact is required between the deposited layer and the substrate to overcome material differences. This has been accomplished by presoaking the membrane tube in the solvent to raise its surface energy. Polymer solutions of various concentrations have been used to promote penetration of the polymer layer into the porous substrate and to control separation layer thickness. The resulting composite membranes have shown repeatable decrease in nitrogen permeability, which is indicative of a decrease in membrane pore size. Studies with water permeation have yielded similar results. We have observed some swelling of the added polymer layer, which causes a slight decrease in membrane pore size, and should result in improved bubble retention. Preliminary studies have also been performed on gas retention in flowing systems. Initial results have been promising, with negligible gas permeation for the coated membranes compared to 100% gas permeation in the uncoated tube.

Ritchie, Stephen M. C.

A Comparison of Coolant Options for Brayton Power Conversion Heat Rejection Systems

This paper describes potential heat rejection design concepts for Brayton power conversion systems. Brayton conversion systems are currently under study by NASA for Nuclear Electric Propulsion (NEP) and surface power applications. The Brayton Heat Rejection Subsystem (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Sodium potassium (NaK) and H2O are two coolant working fluids that have been investigated in the design of a pumped loop and heat pipe space HRS. In general NaK systems are high temperature (300 to 1000 K) low pressure systems, and H2O systems are low temperature (300 to 600 K) high pressure systems. NaK is an alkali metal with health and safety hazards that require special handling procedures. On the other hand, H2O is a common fluid, with no health hazards and no special handling procedures. This paper compares NaK and H20 for the HRS pumped loop coolant working fluid. A detailed Microsoft Excel (Microsoft Corporation, Redmond, WA) analytical model, HRS_Opt, was developed to evaluate the various HRS design parameters. It is capable of analyzing NaK or H2O coolant, parallel or series flow configurations, and numerous combinations of other key parameters (heat pipe spacing, diameter and radial flux, radiator facesheet thickness, fluid duct system pressure drop, system rejected power, etc.) of the HRS. This paper compares NaK against water for the HRS coolant working fluid with respect to the relative mass, performance, design and implementation issues between the two fluids.

Mason, Lee S.

A Comparison of Coolant Options for Brayton Power Conversion Heat Rejection Systems

This paper describes potential heat rejection design concepts for Brayton power conversion systems. Brayton conversion systems are currently under study by NASA for Nuclear Electric Propulsion (NEP) and surface power applications. The Brayton Heat Rejection Subsystem (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Sodium potassium (NaK) and H2O are two coolant working fluids that have been investigated in the design of a pumped loop and heat pipe space HRS. In general NaK systems are high temperature (300 to 1000 K) low pressure systems, and H2O systems are low temperature (300 to 600 K) high pressure systems. NaK is an alkali metal with health and safety hazards that require special handling procedures. On the other hand, H2O is a common fluid, with no health hazards and no special handling procedures. This paper compares NaK and H2O for the HRS pumped loop coolant working fluid. A detailed Microsoft Excel (Microsoft Corporation, Redmond, WA) analytical model, HRS_Opt, was developed to evaluate the various HRS design parameters. It is capable of analyzing NaK or H2O coolant, parallel or series flow configurations, and numerous combinations of other key parameters (heat pipe spacing, diameter and radial flux, radiator facesheet thickness, fluid duct system pressure drop, system rejected power, etc.) of the HRS. This paper compares NaK against water for the HRS coolant working fluid with respect to the relative mass, performance, design and implementation issues between the two fluids.

Siamidis, John

Space Suit Material Compatibility with Space Vehicle Coolant PMS-1.5R

During a survey of 82P on February 11, 2023, a shiny substance was detected on the Progress vehicle. The suspected material was PMS-1.5R, a low volatility silicone oil coolant used in the vehicle. Crew exposure to the coolant was a concern as the low volatility would increase residence time, the time a material will stay on a surface after exposure to vacuum. A review of space suit materials revealed several materials with compatibility concerns that could impact Extravehicular Activity (EVA) operations and safety. To understand the risk, space suit materials were exposed to a simulant and tested. This testing provided the basis for rationale generated to continue with EVA operations for US EVA 86 on April 2, 2023. This testing also served as the basis to assess impacts to ISS EMU hardware due to potential contamination brought inside ISS on Russian space suits during RS EVA 61 on October 25, 2023, following an ISS Russian Multipurpose Lab Module (MLM) radiator leak of the same fluid on October 9, 2023. This paper will discuss the testing performed and analyze test results impacts to EVA operations. Additional work was conducted to determine coolant evaporation rates in space vacuum and demonstrate that no significant unreacted coolant from the MLM leak would remain on ISS surfaces long enough to contaminate the EMU or affect the ISS ECLSS water separator.

Space Suit Materials

Characterization of Fuel-to-Coolant Heat Transfer During Reactivity-Initiated Accidents Using Tightly Coupled Thermal Hydraulics and Fuel Thermomechanics

The reactivity-initiated accident (RIA) is a complex scenario with several tightly interacting physical phenomena. Accurately predicting fuel behavior during these transients is difficult due to limitations in the modeling of fuel-to-coolant heat transfer. Common approaches to simulate RIAs involve standalone calculations using either a fuel performance code or a thermal-hydraulic code. The complex interdependencies of thermal-hydraulic and fuel mechanical behavior suggest that a tight coupling between these codes may provide more accurate predictions of fuel-to-coolant heat transfer and cladding mechanical response. Here, RELAP5-3D and BISON are coupled in this paper to simulate RIAs, and a sensitivity analysis is performed to rank key thermal properties and two-phase heat transfer parameters relevant for fuel-to-coolant heat transfer and cladding failure mechanisms in UO 2 –Zircaloy-4 systems. Gas gap conductance, film boiling heat transfer uncertainty, pulse width, fuel-specific heat capacity, and cladding-specific heat capacity were identified as important parameters. Variations in figures of merit resulting from changes to pulse width and the material thermal properties indicate that time-dependent heat transfer rates are significant for safety-relevant mechanical parameters due to the time dependence of cladding ductility and pellet-cladding mechanical interaction loading. The results suggest that the thermal-hydraulic factors have a nonnegligible influence on the thermomechanical solution and vice versa. Tight coupling of both sets of physics is recommended to improve prediction of fuel behavior during RIAs. Highlights include the following: 1. The RELAP5-3D thermal-hydraulic code and the BISON fuel performance code are tightly coupled for simulation of RIA transients with energy depositions at the Zircaloy-4 cladding failure threshold. 2. Departure from nucleate boiling occurred for all simulated cases. Due to the ductility of fresh fuel, substantial ballooning occurred in most cases. 3. Gas gap conductance, fuel-specific heat capacity, cladding-specific heat capacity, transient pulse width, and film boiling heat transfer were the dominant thermal factors impacting the safety figures of merit at energy depositions.

Critical Heat Flux (CHF)

HIGH BURNUP FUEL-COOLANT INTERACTION ANALYSIS SUPPORTING FUEL SAFETY TESTING AT IDAHO NATIONAL LABORATORY

In the near future, experiments on HBu fuel under loss-of-coolant accident (LOCA) and reactivity-initiated accident (RIA) conditions will be performed within the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL). These experiments will be performed using the Transient Water Irradiation System for TREAT (TWIST) experiment vehicle. To support these experiments, analysis of fuel-coolant interaction (FCI) energetics is underway. This paper discusses FCIs in the context of light water reactor (LWR) safety, differentiating between the severe accident focus of commercial reactors and experimental RIA test programs where FCIs have occurred. However, it is highlighted that as the nuclear industry aims for increased burnup limits, the FCI events observed in RIA test programs may become relevant to commercial LWR safety analysis. The paper then presents developments to the UW-FCI computer program to enable simulation of FCIs initiated by solid fuel particles dispersing into the coolant during RIAs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Development of a Thermal Radiator Optimization Tool with Alternate Coolants

The development of a modeling tool to optimize the design of a thermal radiator based on capacity, rejection temperature, geometry, type and coolant is presented. The radiator size is determined from the desired capacity, environmental conditions and rejection temperature. Flow through the radiator is derived from the overall heat load and prescribed inlet to outlet delta temperature for a given coolant. The tool considers radiator geometry (i.e., tube spacing and diameter, face-sheet thickness, overall size, etc.) and general type (i.e., parallel/manifold versus serpentine) in the optimization. Selection from a handful of potential coolants is also available in the tool which primarily affects necessary tube diameter to maintain turbulent flow and minimize pressure drop. An Equivalent System Mass (ESM) approach is utilized to include pump power in the optimization. Results from the tool and potential future enhancements are also discussed.

Coolant