Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coolant Pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECAR-6580 Rev 0 ASME Section III, Division 5 Analysis of the MARVEL PCS and GVS Top Corner

The purpose of this Engineering Calculations and Analysis Report (ECAR) is to document the structural evaluation for part of the Microreactor Applications Research Validation and Evaluation (MARVEL) Primary Coolant System (PCS) and Guard Vessel System (GVS). For the PCS this relates specifically to the Distribution Plenum (DP), The Intermediate Heat Exchanger (IHX), and the Upper Downcomer (UD). For the GVS, this will include only the top corner that is machined into the DP Top Plate. These components will be evaluated using the 2021 version of ASME Section III, Division 5 [1] which is a design code that governs the construction of vessels, storage tanks, piping, pumps, valves, supports, core support structures and nonmetallic core components for use in high temperature reactor systems and their supporting systems. Materials at high temperature are subject to creep and fatigue mechanisms that require additional analyses that aren’t covered in ASME Section III, Division 1 rules. Division 5 contains two approaches: elastic or inelastic, however, additional Code Cases specific to Division 5, allow for an Elastic-Perfectly Plastic (EPP) approach. The components analyzed in this ECAR will use a combination of the elastic and EPP approach. Only Design and Service Levels A and B are evaluated in this ECAR. Service Level D evaluations for the entire PCS are documented in ECAR-6564, “MARVEL Project Primary Coolant System Pressure Vessel Stress Documentation” [2] and for the entire GVS are documented in ECAR-6574, “MARVEL Guard Vessel System FEA and ASME Analysis” [3]. The Design and Service Level A and B analyses for the PCS Downcomer piping and Core Barrel are documented in ANL-24/36, "Engineering Calculations and Analysis of the Core Barrel and Downcomer Piping in the MARVEL PCS” [4], and the GVS (except for the top corner) is in ECAR-6574, “MARVEL Guard Vessel System FEA and ASME Analysis.” See Section 2.0 for more detail on the analysis boundaries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗

SAS4A/SASSYS-1 Modeling Improvements for the Transition to Natural Circulation

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. In recent years, SAS has undergone a number of improvements to enable improved safety analyses that meet end users’ modernized needs while complying with the current regulatory environment. Improvements made in versions 5.6 and 5.7 released within the last year include the development of anisotropic Reynolds number dependent loss coefficients throughout the core and heat transport systems, the ability to distinguish the transition friction factor from the fully developed laminar and turbulent friction factors, and timedependent direct coolant and wall heating for pipe-like elements in the heat transport systems. While it was possible to capture loss coefficients, friction factors, and heat transfer from an element to a heat sink within SAS in previous versions of the code, users were required to end the simulation and restart it to adjust the input to account for any significant changes to the values during the transient. With these improvements, users can better capture flow reversal, pump heating, and the transition from forced to natural circulation without being limited to constant orifice coefficients, constant heat sinks, or the need to restart the simulation and modify input. In order to demonstrate the application of these improvements, a loss of flow transient is simulated for the Advanced Burner Test Reactor (ABTR).

SAS4A/SASSYS-1↗

A RELAP5-3D Model of the Lobo Lead Loop

The goal of our research is to build upon the capability of RELAP5-3D to model molten lead systems. Molten lead has several potential uses in future advanced reactors like the lead fast reactor or fusion reactors that utilize dual-coolant lead lithium blankets. This potential for use in future generations of reactors highlights the necessity to develop molten lead models to ensure that they can accurately predict the thermohydraulic behavior. We have developed a RELAP5-3D model of the Lobo Lead Loop facility, located at the University of New Mexico, to verify the accuracy of RELAP5-3D via comparison to existing computational fluid dynamics results and analytical calculations. It was found that RELAP5-3D accurately calculated radiative heat transfer (within < 1%) when compared to theoretical calculations. In addition, pressure drop calculations done in RELAP5-3D demonstrated reasonable agreement within 20 kPa, mostly within ~7-15%, when compared to the computational fluid dynamics model of the facility developed by the University of New Mexico, and captured the dependence of pressure drop on flow velocity accurately. Finally, a hypothetical loss of flow transient was imposed on the RELAP5-3D model to determine the feasibility of performing a similar experiment with the Lobo Lead Loop. It was found that such an experiment could be possible as the RELAP5-3D model indicated that the temperatures of the fluid would not exceed limiting temperatures of the structure (1658 K) nor the maximum temperature of the electromagnetic pump inlet (823 K). Although there is not experimental data to begin validation, the model will be readily available for future validation studies when the experimental data is generated, especially as the model continues to evolve over time. Furthermore, the results so far demonstrate a promising first step in the verification/validation of the RELAP5-3D model of the Lobo Lead Loop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Microreactor Optimization Using Simulation And Economics (mouse)

Microreactor Optimization Using Simulation and Economics (MOUSE) is a tool that integrates both nuclear microreactor design and reactor economics to provide comprehensive evaluations and optimizations. This tool enables stakeholders to explore the interplay between technical and economic variables, guiding them towards effective and competitive microreactor solutions. For the reactor core simulations, MOUSE leverages the OpenMC Monte Carlo Particle Transport Code to perform detailed core simulations for various microreactor designs. The included OpenMC models are 2D core designs of a Liquid Metal Thermal Microreactor (LMTR), a Gas-Cooled TRISO-Fueled Microreactor (GCMR), and a Heat Pipe Microreactor. Beyond core design, MOUSE includes simplified calculations for: - Calculating the masses of heat exchangers within the system. - Mechanical power of pumps. - Estimating the area occupied by various buildings within the nuclear plant. For the economic analysis, MOUSE provides detailed bottom-up cost estimates, encompassing a wide range of costs including preconstruction costs, direct costs, indirect costs, training costs, financial costs, operation & maintenance (O&M) costs, and fuel costs. These cost estimations are developed using data from the MARVEL project and additional literature sources, enabling the calculation of total capital costs and levelized cost of energy for both first-of-a-kind and nth-of-a-kind microreactors. MOUSE also enables analysis of the cost drivers and competitiveness in the electricity market. MOUSE allows users to modify a wide array of technical and economic parameters to evaluate different scenarios and their impacts. Examples of these parameters include: Fuels, coolants, or reflector materials Enrichment levels Control drum materials and geometry Fuel pin geometry and materials Moderator pin geometry and materials Reactor core and reflector dimensions Packing factor for the TRISO particles Nuclear reactor power and reactor burnup Number of sensors Shielding thickness Reactor vessel and guard vessel dimensions Operational staff requirements Number of emergency shutdowns Levelization period Interest rate Construction duration Since MOUSE is powered by the WATTS toolkit, it supports optimization studies, parametric analyses, and uncertainty calculations/propagation. The optimization techniques enable users to identify optimal design and economic configurations. The parametric analysis tools allow users to explore the sensitivity of various parameters, while uncertainty propagation helps quantify the impact of uncertainties on overall performance and cost. User Interface and Workflow: Currently, MOUSE is a command-line-based tool. Users can input various reactor design or economic parameters, modify the designs, run simulations, and visualize results through comprehensive data visualization and reporting capabilities. The typical workflow involves setting up the reactor model, defining economic parameters, running simulations, and analyzing the results to make informed decisions. By combining advanced design calculations with detailed economic modeling, MOUSE provides a robust framework for optimizing nuclear microreactor technologies, enhancing their competitiveness, and guiding stakeholders towards innovative and cost-effective solutions.

Hanna, Botros [Idaho National Laboratory (INL), Id↗

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

SAM Code Enhancements for Modeling of Liquid Metal-Cooled Fast Reactor Concepts

The SAM code is under development and supported by DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. These advanced reactor concepts incorporate novel and improved approaches to achieve safety and economic feasibility. This report summarizes two major efforts in addressing the modeling gaps in SAM for liquid-metal-cooled fast reactor (LMFR) applications, i.e. thermal mixing and stratification phenomena in large pools and corrosion-oxidation of components in flowing lead. A new one-dimensional model for thermal mixing and stratification effects in large pools and enclosures is developed and implemented. Thermal mixing and stratification occur when fluid enters a pool at a temperature different than the bulk fluid itself, a scenario often encountered during transients in pool-type systems. These phenomena are critical for the safety of reactors, impacting phenomena like natural circulation, which is essential for passive cooling. The improved model in SAM addresses limitations of state-of-the-art approaches by combining one-dimensional (1D) channels, representing the coolant jet flow, with lumped-parameter zero-dimensional (0D) pools, representing the rest of coolant in the tank. Energy exchange between the 1D jet and the 0D pools is based on heat transfer correlations calibrated against 3D simulations. It is verified that this model can handle various flow configurations, including hot jets in colder pools, cold jets in hotter pools, and the presence of features like ceilings, free surfaces, and obstacles. Additionally, validation against experimental data demonstrates the ability of the model to capture mixing and stratification effects in a wide range of conditions. The flexibility and improved accuracy of the new model make it a valuable tool for reactor safety analysis, allowing for the simulation of different geometries encountered in advanced reactors. A system-level corrosion modeling capability is developed and implemented in SAM to support Lead Fast Reactor (LFR) development. Although the initial focus of this capability will be on LFR application, this can later be expanded to include other liquid metals such as Lead-Bismuth Eutectic (LBE) and PbLi. This report summarizes the common corrosion mitigation strategies and outlines the progress on implementing and validating a corrosion-oxidation model in SAM. Verification and validation of the corrosion-oxidation portion of the model was performed using analytical solution and measured data from samples tested in the non-isothermal pumped lead loop at IPPE Obninsk. The iron transport and corrosion/precipitation portion of the model was assessed using an analytical model and measured corrosion depths from a natural convection lead loop experiment performed at CEA. It is demonstrated that the model implemented in SAM performed well in these assessments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗