Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

L2 Milestone: Simulations as Data. Quantum Molecular Dynamics Contribution

Milestone description: Direct Numerical Simulations and Quantum Molecular Dynamics simulations have been used as one would use physical experiments for cases where the physical data are not available. The goal of this milestone is to assess these simulations in the manner that they are being used and the priority of the specific configurations being planned.

Condensed Matter Physics, Superconductivity & Supe↗

GALE 3.1 Verification Report

This report is documentation of the verification activities that have been performed on GALE-3.1 to ensure that the codes meet the requirements and specifications set forth by NRC and that the code meets its intended purpose. Additional benchmark tests for GALE-3.1 are documented in Appendix A of NUREG-0016, Revision 2 for GALE-BWR 3.1 and Appendix A of NUREG-0017, Revision 2 for GALE-PWR 3.1. These activities are done in accordance with the GALE Software Quality Assurance Plan (PNNL-24249) and the GALE Configuration Management & Maintenance Plan (PNNL-24250). These two plans meet the requirements set for by both PNNL software quality assurance requirements and the NRC’s Software Quality Assurance Program and Guidelines (NUREG/BR-0167). The verification activities are documented to conform to Level 2 requirements of NUREG/BR-0167. Verifications were performed for both GALE-3.1 BWR and GALE-3.1 PWR Codes. The GALE 3.1 BWR and PWR codes are computerized mathematical models for calculating the releases of radioactive material in gaseous and liquid effluents. These computer codes are tools which can be used to determine conformance with the requirements of Appendix I to Title 10, Part 50 of the Code of Federal Regulations (10 CFR 50).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GALE 3.2 Verification Report

This report is documentation of the verification activities that have been performed on GALE-3.2 to ensure that the codes meet the requirements and specifications set forth by NRC and that the code meets its intended purpose. These activities are done in accordance with the GALE Software Quality Assurance Plan (PNNL-24249) and the GALE Configuration Management & Maintenance Plan (PNNL-24250). These two plans meet the requirements set for by both PNNL software quality assurance requirements and the NRC’s Software Quality Assurance Program and Guidelines (NUREG/BR-0167). The verification activities are documented to conform to Level 2 requirements of NUREG/BR-0167. Verifications were performed for both GALE-3.2 BWR and GALE-3.2 PWR Codes. The GALE 3.2 BWR and PWR codes are computerized mathematical models for calculating the releases of radioactive material in gaseous and liquid effluents. These computer codes are tools which can be used to determine conformance with the requirements of Appendix I to Title 10, Part 50 of the Code of Federal Regulations (10 CFR 50).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments Execution Plan (IER-518 CED-3a)

As part of the experiment design and planning, the critical experiment design team (CEDT), as well as additional stakeholders, convened a series of meetings to discuss the goals and requirements of execution for this experiment. The slides from these meetings are attached in Appendix A. The following sections summarize the outcome of those discussions and present the planned experimental configurations and measurements. The stated goals of this experiment are as follows: 1) Measure time-tagged list-mode data for configurations exceeding neutron multiplication of 100; 2) Provide intercomparison between LLNL, LANL, and IRSN detector systems and methodologies; 3) Generate experiment execution report(s) useful to a fundamental physics benchmark for the ICSBEP; 4) Leverage existing critical experiment and detector system benchmarks to limit required modeling and uncertainty analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Software Quality Assurance for the MOOSE-Based Open-Source Multiphysics Code Cardinal - An Expanded CI Testing Suite

Cardinal is a wrapping of the GPU-oriented spectral element Computational Fluid Dynamics (CFD) code NekRS and the Monte Carlo particle transport code OpenMC within the Multiphysics Object-Oriented Simulation Environment (MOOSE). Cardinal provides high-resolution thermal-hydraulics and/or radiation transport feedback to MOOSE multiphysics simulations. Multiphysics feedback is implemented in a geometry-agnostic manner which eliminates the need for rigid one-to-one mappings. A generic data transfer implementation also allows NekRS and OpenMC to couple to any MOOSE application, enabling a broad set of multiphysics capabilities. Cardinal simulations can also leverage combinations of MPI, OpenMP, and GPU resources. Cardinal continuous development and improvement efforts have led to the software being considered as a high-fidelity design and licensing tool for key areas of nuclear reactor relevant physics, including neutron transport, fluid flow, heat transfer, and mechanical processes. The fast development and expansion of the software from a pure R&D framework towards its application in the nuclear industry and regulation require a focus on developing, enhancing and, maintaining Cardinal’s software quality through strict adherence to a Software Quality Assurance (SQA) framework and SQA program. To facilitate compliance with SQA standards, the Cardinal SQA Program has been initiated during Fiscal Year 2023 (FY23). During the development of the Cardinal SQA Program, multiple gaps have been identified. These gaps are primarily related to model verification and code pedigree as they relate to the use of Cardinal as a safety analysis tool. These gaps have been captured in a report published in 2023. A second report highlighted the progress made during Fiscal Year 2024 (FY24) and described Argonne’s effort to document and integrate software verification within Cardinal’s software development process. This report documents a snapshot of the verification test cases currently available for Cardinal and NekRS in their assimilation into a Continuous Integration (CI) platform. Following the CI practice permits the integrating of source code changes frequently and ensuring that the integrated codebase clears the verification testing for the software. It should be noted that the SQA program itself, including the program plans, procedures, configuration management, and testing strategies, need to be developed in a future step of this task.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scaled Testing to Evaluate Pulse Jet Mixer Performance in Waste Treatment Plant Mixing Vessels

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being designed and built to pre-treat and vitrify the waste in Hanford’s 177 underground waste storage tanks. Numerous process vessels will hold waste at various stages in the WTP. These vessels have pulse jet mixer (PJM) systems. A test program was developed to evaluate the adequacy of mixing system designs in the solids-containing vessels in the WTP. The program focused mainly on non-cohesive solids behavior. Specifically, the program addressed the effectiveness of the mixing systems to suspend settled solids off the vessel bottom, and distribute the solids vertically. Experiments were conducted at three scales using various particulate simulants. A range of solids loadings and operational parameters were evaluated, including jet velocity, pulse volume, and duty cycle. In place of actual PJMs, the tests used direct injection from tubes with suction at the top of the tank fluid. This gave better control over the discharge duration and duty cycle and simplified the facility requirements. The mixing system configurations represented in testing varied from 4 to 12 PJMs with various jet nozzle sizes. In this way the results collected could be applied to the broad range of WTP vessels with varying geometrical configurations and planned operating conditions. Data for “just-suspended velocity”, solids cloud height, and solids concentration vertical profile were collected, analyzed, and correlated. The correlations were successfully benchmarked against previous large-scale test results, then applied to the WTP vessels using reasonable assumptions of anticipated waste properties to evaluate adequacy of the existing mixing system designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Finite Element Modeling of Spent Nuclear Fuel in Dry Storage under Seismic Excitation

Spent nuclear fuel (SNF) is currently stored at independent spent fuel storage installations (ISFSIs) at nuclear power plant sites across the US. The US Department of Energy (DOE) Spent Fuel and Waste Science and Technology (SFWST) program is currently working to understand the response of SNF during a seismic event. This investigation is part of a long-term effort by DOE to quantify the external mechanical loads on SNF. The SFWST program has recently completed campaigns evaluating SNF behavior during normal conditions of transport and in 30 cm package drop scenarios; both campaigns included a combination of testing and modeling. Likewise, the investigation into seismic response of SNF will include full-size shake table tests of a vertical storage overpack containing instrumented surrogate fuel assemblies, as well as pre- and post-test finite element modeling. This work focuses on the development of finite element models simulating the planned test configuration. The seismic response is calculated at two scales: at the package level, and at the fuel level. The package level model evaluates the behavior of the storage overpack and its contents in response to the ground motions of a representative earthquake. The motion of the package is input to the fuel level model, which consists of a detailed finite element model of a 17x17 or 16x16 pressurized water reactor (PWR) fuel assembly or of a 10x10 boiling water reactor (BWR) fuel assembly. The stress and strain on individual components such as fuel rods and guide tubes are extracted from this model. This work details the SNF response to various input ground motions, considering representative earthquakes in the Central and Eastern US under various site conditions. Also discussed is the development of a “reduced scope” finite element model of the SNF, which consists of a single fuel rod while retaining the dynamic response of the entire fuel assembly. This reduced scope model addresses the significant computational expense of modeling the SNF under long-duration input ground motions and facilitates simulating additional parameter variations of the model beyond the as-tested configuration. The modeling results provide important insight that will help to inform future testing and modeling efforts by the SFWST program to close the knowledge gap related to external loads on SNF.

Kadooka, Kevin↗

The National Ignition Facility Data Repository

NIF is the world's largest and most energetic laser experimental system, providing a scientific center to study inertial confinement fusion and matter at extreme energy densities and pressures. This presentation discusses the design, architecture, and implementation of the NIF Data Repository (NDR), which provides for the capture and long-term digital storage of peta-scale datasets produced by conducting experimental campaigns. The NDR is a federated database that provides for the capture of: experimental campaign plans, machine configuration & calibration data, raw experimental results and the processed results produced by scientific workflows. The NDR provides for metadata, pedigree, quality, effectivity, versioning and access control for each of the data categories. A critical capability of the NDR is its extensive data provisioning capabilities and protocols that enable scientists, local and remote alike, to review the results of analysis produced by the NDR's analysis pipeline or to download datasets for offline analysis. The NDR provides for the capture of these locally-produced analysis results to enable both peer review and follow-on automated analysis.

42 ENGINEERING↗

Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-structure dose-volume metrics

To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non–small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: IMRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose ∼ 150% PD) for a 6-MV photon beam. Plan conformality, R{sub 50} (ratio of volume circumscribed by the 50% isodose line and the PTV), and D{sub 2} {sub cm} (D{sub max} at a distance ≥2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD]) and percent V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} Gy were assessed. Spinal cord and esophagus D{sub max} and D{sub 5}/D{sub 50} were computed. Chest wall (CW) D{sub max} and absolute V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} {sub Gy} were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and V{sub 10}/V{sub 5} {sub Gy}, as well as contralateral CW D{sub max} and V{sub 10}/V{sub 5} {sub Gy} (all p < 0.001). Nominal reductions of D{sub max} and D{sub 5}/D{sub 50} for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, R{sub 50} significantly improved with IMRT-s/VMAT-c (p < 0.001/p = 0.008), whereas D{sub 2} {sub cm} significantly improved with VMAT-c (p < 0.001). Plan delivery efficiency improved with sectored technique (p < 0.001); mean monitor unit (MU)/cGy of PD decreased from 5.8 ± 1.9 vs 5.3 ± 1.7 (IMRT) and 2.7 ± 0.4 vs 2.4 ± 0.3 (VMAT). The sectored configuration achieves unambiguous dosimetric advantages over circumferential arrangement in terms of esophageal, contralateral CW, and contralateral lung sparing, in addition to being more efficient at delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-548: How To Decrease Spine Dose In Patients Who Underwent Sterotactic Spine Radiosurgery?

Purpose: Stereotactic radiosurgery for spine metastases involves irradiation using a single high dose fraction. The purpose of this study was to dosimetrically compare stereotactic spine radiosurgery(SRS) plans using a recently new volumetric modulated arc therapy(VMAT) technique against fix-field intensity-modulated radiotherapy(IMRT). Plans were evaluated for target conformity and spinal cord sparing. Methods: Fifteen previously treated patients were replanned using the Eclipse 10.1 TPS AAA calculation algorithm. IMRT plans with 7 fields were generated. The arc plans used 2 full arc configurations. Arc and IMRT plans were normalized and prescribed to deliver 16.0 Gy in a single fraction to 90% of the planning target volume(PTV). PTVs consisted of the vertebral body expanded by 3mm, excluding the PRV-cord, where the cord was expanded by 2mm.RTOG 0631 recommendations were applied for treatment planning. Partial spinal cord volume was defined as 5mm above and below the radiosurgery target volume. Plans were compared for conformity and gradient index as well as spinal cord sparing. Results: The conformity index values of fifteen patients for two different treatment planning techniques were shown in table 1. Conformity index values for 2 full arc planning (average CI=0.84) were higher than that of IMRT planning (average CI=0.79). The gradient index values of fifteen patients for two different treatment planning techniques were shown in table 2. Gradient index values for 2 full arc planning (average GI=3.58) were higher than that of IMRT planning (average GI=2.82).The spinal cord doses of fifteen patients for two different treatment planning techniques were shown in table 3. D0.35cc, D0.03cc and partial spinal cord D10% values in 2 full arc plannings (average D0.35cc=819.3cGy, D0.03cc=965.4cGy, 10%partial spinal=718.1cGy) were lower than IMRT plannings (average D0.35cc=877.4cGy, D0.03c=1071.4cGy, 10%partial spinal=805.1cGy). Conclusions: The two arc VMAT technique is superior to 7 field IMRT technique in terms of both spinal cord sparing and better conformity and gradient indexes.

60 APPLIED LIFE SCIENCES↗

Load planning in the dark: RH-TRU waste container load planning at Sandia National Laboratories/New Mexico - 15116

Sandia National Laboratories (Sandia) performed several sets of experiments during the 1970's and 1980's with fresh and irradiated mixed oxide (MOX) and uranium oxide (UO{sub 2}) materials designed to simulate various fuel responses under varying reactor conditions. These research materials were from light water and breeder mixed oxide reactors. The experimental vessels and extraneous piece parts resulting from the experiments were identified as eligible for disposal at the Waste Isolation Pilot Plant (WIPP) as remote-handled (RH) transuranic (TRU) waste. Once Sandia received the approval to dispose at WIPP, discussions began with the Carlsbad Field Office (CBFO) and Nuclear Waste Partnerships, LLC (NWP) to provide Central Characterization Program (CCP) support for certified acceptable knowledge, visual examination, and dose-to-curie for the repackaging effort. In addition to the WIPP support, Sandia was required to prepare a load plan describing the configuration of the parent containers and how they could be repackaged to meet WIPP and other regulatory requirements. However, all of these containers were packaged as material twenty (20) or thirty (30) years ago and the records of the packaging process and configuration were not documented as waste. Therefore, it seemed that the load plans were prepared with limited information regarding parent container configuration, hence in the dark. The design of the Auxiliary Hot Cell Facility (AHCF) in technical area (TA) V, where the repackaging was to take place, along with the shipping requirements for the RH 72-B cask, limited the options for repackaging. This configuration required that 0.114 m{sup 3} (30-gallon) containers be packaged in the hot cell, removed and placed into 0.208 m{sup 3} (55-gallon) containers to mitigate contamination issues. The material had been tracked as accountable nuclear material and Sandia had verified Material Control and Accountability (MC and A) data on each parent container. Based on the MC and A data, scaling factors could be determined and sampling and analysis was not required. However, it meant that parent containers could not be split into two daughter containers, though two or more parent containers could be combined into one daughter. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A LEAN SYSTEMS APPROACH TO IMPROVING MAINTENANCE OUTPUT AND CONFIGURATION MANAGEMENT

The purpose of this capstone paper is to apply a lean systems approach to the current maintenance planning program in the Assembly/Disassembly Organization. This capstone will take a two-pronged approach to address both output rate in maintenance planning and accurate configuration management resulting from maintenance work orders. In short, the current system suffers from waste in the planning process due lack of procedures to address varying maintenance packages, including maintenance packages which include changes to configuration managed systems. The capstone will detail a lean systems approach to proper characterization of maintenance jobs and integration of change management into the maintenance process in order to retain proper control of the systems used to produce in this nuclear facility.

99 GENERAL AND MISCELLANEOUS↗

Measuring recoiling nucleons from the nucleus with the future Electron Ion Collider

Short range correlated nucleon-nucleon (NN) pairs are an important part of the nuclear ground state. They are typically studied by scattering an electron from one nucleon in the pair and detecting its spectator correlated partner (spectator-nucleon tagging). The Electron Ion Collider (EIC)should be able to detect these nucleons, since they are boosted to high momentum in the lab frame by the momentum of the ion beam. To determine the feasibility of these studies with the planned EIC detector configuration, we have simulated quasi-elastic scattering for two electron and ion beam energy configurations: 5 GeV electrons and 41 GeV/A ions, and 10 GeV electrons and 110 GeV/A ions. We show that the knocked-out and recoiling nucleons can be detected over a wide range of initial nucleon momenta. We also show that these measurements can achieve much larger momentum transfers than current fixed target experiments. By detecting both low and high initial-momentum nucleons,the EIC will provide the data that should allow scientists to definitively show if the EMC effect and short-range correlation are connected, and to improve our understanding of color transparency

Hauenstein, F. (ORCID:0000000212652212)↗

Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy?

This study aimed to quantify dosimetric effects of weight loss for nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Overall, 25 patients with NPC treated with IMRT were enrolled. We simulated weight loss during IMRT on the computer. Weight loss model was based on the planning computed tomography (CT) images. The original external contour of head and neck was labeled plan 0, and its volume was regarded as pretreatment normal weight. We shrank the external contour with different margins (2, 3, and 5 mm) and generated new external contours of head and neck. The volumes of reconstructed external contours were regarded as weight during radiotherapy. After recontouring outlines, the initial treatment plan was mapped to the redefined CT scans with the same beam configurations, yielding new plans. The computer model represented a theoretical proportional weight loss of 3.4% to 13.7% during the course of IMRT. The dose delivered to the planning target volume (PTV) of primary gross tumor volume and clinical target volume significantly increased by 1.9% to 2.9% and 1.8% to 2.9% because of weight loss, respectively. The dose to the PTV of gross tumor volume of lymph nodes fluctuated from −2.0% to 1.0%. The dose to the brain stem and the spinal cord was increased (p < 0.001), whereas the dose to the parotid gland was decreased (p < 0.001). Weight loss may lead to significant dosimetric change during IMRT. Repeated scanning and replanning for patients with NPC with an obvious weight loss may be necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integral dose conservation in radiotherapy

Treatment planners frequently modify beam arrangements and use IMRT to improve target dose coverage while satisfying dose constraints on normal tissues. The authors herein analyze the limitations of these strategies and quantitatively assess the extent to which dose can be redistributed within the patient volume. Specifically, the authors hypothesize that (1) the normalized integral dose is constant across concentric shells of normal tissue surrounding the target (normalized to the average integral shell dose), (2) the normalized integral shell dose is constant across plans with different numbers and orientations of beams, and (3) the normalized integral shell dose is constant across plans when reducing the dose to a critical structure. Using the images of seven patients previously irradiated for cancer of brain or prostate cancer and one idealized scenario, competing three-dimensional conformal and IMRT plans were generated using different beam configurations. Within a given plan and for competing plans with a constant mean target dose, the normalized integral doses within concentric ''shells'' of surrounding normal tissue were quantitatively compared. Within each patient, the normalized integral dose to shells of normal tissue surrounding the target was relatively constant (1). Similarly, for each clinical scenario, the normalized integral dose for a given shell was also relatively constant regardless of the number and orientation of beams (2) or degree of sparing of a critical structure (3). 3D and IMRT planning tools can redistribute, rather than eliminate dose to the surrounding normal tissues (intuitively known by planners). More specifically, dose cannot be moved between shells surrounding the target but only within a shell. This implies that there are limitations in the extent to which a critical structure can be spared based on the location and geometry of the critical structure relative to the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Single-Isocenter Volumetric Modulated Arc Radiosurgery for Treatment of Multiple Brain Metastases

Purpose: To evaluate the relative plan quality of single-isocenter vs. multi-isocenter volumetric modulated arc therapy (VMAT) for radiosurgical treatment of multiple central nervous system metastases. Methods and Materials: VMAT plans were created using RapidArc technology for treatment of simulated patients with three brain metastases. The plans consisted of single-arc/single-isocenter, triple-arc (noncoplanar)/single-isocenter, and triple-arc (coplanar)/triple-isocenter configurations. All VMAT plans were normalized to deliver 100% of the 20-Gy prescription dose to all lesions. The plans were evaluated by calculation of Paddick and Radiation Therapy Oncology Group conformity index scores, Paddick gradient index scores, and 12-Gy isodose volumes. Results: All plans were judged clinically acceptable, but differences were observed in the dosimetric parameters, with the use of multiple noncoplanar arcs showing small improvements in the conformity indexes compared with the single-arc/single-isocenter and triple-arc (coplanar)/triple-isocenter plans. Multiple arc plans (triple-arc [noncoplanar]/single-isocenter and triple-arc [coplanar]/triple-isocenter) showed smaller 12-Gy isodose volumes in scenarios involving three metastases spaced closely together, with only small differences noted among all plans involving lesions spaced further apart. Conclusion: Our initial results suggest that single-isocenter VMAT plans can be used to deliver conformity equivalent to that of multiple isocenter VMAT techniques. For targets that are closely spaced, multiple noncoplanar single-isocenter arcs might be required. VMAT radiosurgery for multiple targets using a single isocenter can be efficiently delivered, requiring less than one-half the beam time required for multiple isocenter set ups. VMAT radiosurgery will likely replace multi-isocenter techniques for linear accelerator-based treatment of multiple targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior liver sparing by combined coplanar/noncoplanar volumetric-modulated arc therapy for hepatocellular carcinoma: A planning and feasibility study

Compared with step-and-shoot intensity-modulated radiotherapy (sIMRT) and tomotherapy, volumetric-modulated arc therapy (VMAT) allows additional arc configurations in treatment planning and noncoplanar (NC) delivery. This study was first to compare VMAT planning with sIMRT planning, and the second to evaluate the toxicity of coplanar (C)/NC-VMAT treatment in patients with hepatocellular carcinoma (HCC). Fifteen patients with HCC (7 with left-lobe and 8 with right-lobe tumors) were planned with C-VMAT, C/NC-VMAT, and sIMRT. The median total dose was 49 Gy (range: 40 to 56 Gy), whereas the median fractional dose was 3.5 Gy (range: 3 to 8 Gy). Different doses/fractionations were converted to normalized doses of 2 Gy per fraction using an α/β ratio of 2.5. The mean liver dose, volume fraction receiving more than 10 Gy (V10), 20 Gy (V20), 30 Gy (V30), effective volume (V{sub eff}), and equivalent uniform dose (EUD) were compared. C/NC-VMAT in 6 patients was evaluated for delivery accuracy and treatment-related toxicity. Compared with sIMRT, both C-VMAT (p = 0.001) and C/NC-VMAT (p = 0.03) had significantly improved target conformity index. Compared with C-VMAT and sIMRT, C/NC-VMAT for treating left-lobe tumors provided significantly better liver sparing as evidenced by differences in mean liver dose (p = 0.03 and p = 0.007), V10 (p = 0.003 and p = 0.009), V20 (p = 0.006 and p = 0.01), V30 (p = 0.02 and p = 0.002), V{sub eff} (p = 0.006 and p = 0.001), and EUD (p = 0.04 and p = 0.003), respectively. For right-lobe tumors, there was no difference in liver sparing between C/NC-VMAT, C-VMAT, and sIMRT. In all patients, dose to more than 95% of target points met the 3%/3 mm criteria. All 6 patients tolerated C/NC-VMAT and none of them had treatment-related ≥ grade 2 toxicity. The C/NC-VMAT can be used clinically for HCC and provides significantly better liver sparing in patients with left-lobe tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗