Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comstock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Resolved Reference Projections of Building Energy Use for the Contiguous United States: Building Sector Energy Baselines, Projection Methods, and Results

This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants' chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Advanced Rooftop Unit Control

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Why Don't They Just Give Us Money? Project Cost Estimating and Cost Reporting

Successful projects require an integrated approach to managing cost, schedule, and risk. This is especially true for complex, multi-year projects involving multiple organizations. To explore solutions and leverage valuable lessons learned, NASA's Virtual Project Management Challenge will kick off a three-part series examining some of the challenges faced by project and program managers when it comes to managing these important elements. In this first session of the series, we will look at cost management, with an emphasis on the critical roles of cost estimating and cost reporting. By taking a proactive approach to both of these activities, project managers can better control life cycle costs, maintain stakeholder confidence, and protect other current and future projects in the organization's portfolio. Speakers will be Doug Comstock, Director of NASA's Cost Analysis Division, Kristin Van Wychen, Senior Analyst in the GAO Acquisition and Sourcing Management Team, and Mary Beth Zimmerman, Branch Chief for NASA's Portfolio Analysis Branch, Strategic Investments Division. Moderator Ramien Pierre is from NASA's Academy for Program/Project and Engineering Leadership (APPEL).

Comstock, Douglas A.↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies: Preprint

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants’ chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗