Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computerized simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Utility of the Virtual Liver Parenchymal Perfusion Area Using a Commercially Available Workstation in Transarterial Chemoembolization for Hepatocellular Carcinoma

Purpose: To evaluate the accuracy of the virtual liver parenchymal perfusion area using a commercially available workstation and liver analysis software in conventional transarterial chemoembolization (cTACE) for hepatocellular carcinoma (HCC). Materials and Methods: This method was retrospectively applied to 29 treated HCCs in 23 patients. The virtual embolic area (VEA) was estimated based on cone beam computed tomography during hepatic arteriography using a commercially available workstation and liver analysis software by two observer groups (group A: experts; group B: semi-experts). The real embolic area (REA) was defined as the area where iodized oil accumulated on computed tomography at 1 week after cTACE. The REA was estimated by each of the two groups, and the mean REA between the groups (mREA) was used as a standard reference. Agreement of volume and cross-sectional area in three orthogonal planes between the VEA and mREA were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The ICCs for volume between VEA and mREA were 0.97 and 0.88 for groups A and B, respectively, and those for cross-sectional area were 0.94 and 0.88 for the axial plane, 0.95 and 0.83 for the coronal plane, and 0.87 and 0.74 for the sagittal plane, respectively. Thus, the overall agreement was excellent, except for the sagittal imaging plane in group B. Conclusion: This method using a commercially available workstation and liver analysis software can be useful for estimating the embolic area in cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three dimensional (3D) microstructure-based finite element modeling of Al-SiC nanolaminates using focused ion beam (FIB) tomography

Al-SiC nanolaminate composites show promise as high performance coating materials due to their combination of strength and toughness. Although a significant amount of modeling effort has been focused on materials with an idealized flat nanostructure, experimentally these materials exhibit complex undulating layer geometries. This work utilizes FIB tomography to characterize this nanostructure in 3D and finite element modeling to determine the effect that this complex structure has on the mechanical behavior of these materials. A sufficiently large volume was characterized such that a 1 × 2 μm micropillar could be generated from the dataset and compared directly to experimental results. The mechanical response from this nanostructure was then compared to pillar models using simplified structures with perfectly flat layers, layers with sinusoidal waviness, and layers with arc segment waviness. The arc segment based layer geometry showed the best agreement with the experimentally determined structure, indicating it would be the most appropriate geometry for future modeling efforts. - Highlights: •FIB tomography was used to determine the structure of an Al-SiC nanolaminate in 3D. •FEM was used to compare the deformation of the nanostructure to experimental results. •Idealized structures from literature were compared to the FIB determined structure. •Arc segment based structures approximated the FIB determined structure most closely.

36 MATERIALS SCIENCE↗

Automated correlative segmentation of large Transmission X-ray Microscopy (TXM) tomograms using deep learning

Highlights: • A unique automated segmentation approach for large 3D nanotomography datasets obtained by Transmission X-ray Microscopy (TXM) in an Al-Cu alloy. • Automated segmentation using a Convolutional Neural Network (CNN) architecture based on a deep learning approach was employed. • This extremely versatile technique is capable of emulating the manual segmentation process effectively. • Quantitative comparison between manual segmentation and CNN architecture established the accuracy of this automated technique. • Its ability to robustly process ultra-large volumes of data in relatively small time frames can exponentially accelerate tomographic data analysis. - Abstract: A unique correlative approach for automated segmentation of large 3D nanotomography datasets obtained using Transmission X-ray Microscopy (TXM) in an Al-Cu alloy has been introduced. Automated segmentation using a Convolutional Neural Network (CNN) architecture based on a deep learning approach was employed. This extremely versatile technique is capable of emulating the manual segmentation process effectively. Coupling this technique with post-scanning SEM imaging ensured precise estimation of 3D morphological parameters from nanotomography. The segmentation process as well as subsequent analysis was expedited by several orders of magnitude. Quantitative comparison between segmentation performed manually and using the CNN architecture established the accuracy of this automated technique. Its ability to robustly process ultra-large volumes of data in relatively small time frames can exponentially accelerate tomographic data analysis, possibly opening up novel avenues for performing 4D characterization experiments with finer time steps.

36 MATERIALS SCIENCE↗

Three-dimensional grain mapping of open-cell metallic foam by integrating synthetic data with experimental data from high-energy X-ray diffraction microscopy

Highlights: • High-energy X-ray measurements are made for ligaments of an open-cell aluminum foam. • Grain centroids and orientations are measured using high-energy X-ray diffraction. • 3D grain map is virtually reconstructed by integrating measured and synthetic data. - Abstract: The complex mechanical response of open-cell foams depends strongly on the hierarchy of length scales inherent in them, from engineering-part scale to the ligament scale through the grain scale down to the crystal-lattice scale. A first step toward understanding and predicting the coordinated mechanical response across length scales requires characterizing the open-cell foam structure in three dimensions at relevant scales. Here, we present an initial attempt to digitally represent a physically-realized aluminum alloy foam in terms of both its geometry/topology as well as its underlying crystallographic orientations by integrating several advanced techniques. Specifically, we use a combination of X-ray computed tomography and X-ray diffraction microscopy in conjunction with synthetic grain mapping. Experimental investigation of the foam shows relatively large grain sizes with respect to the ligament length scale, implying that competing mechanics at different length scales (i.e. grain scale vs. ligament scale) will need to be fully incorporated to understand the mechanical behavior of the foam. The integration of non-destructive measurement techniques with synthetic-data generation provides a path toward realistic modeling of bulk samples of open-cell metal foam resolved at the scale of individual grains.

36 MATERIALS SCIENCE↗

Flow characteristics in narrowed coronary bypass graft

Tortuous saphenous vein graft (SVG) hemodynamics was investigated using computational fluid dynamics (CFD) techniques. Computed tomography (CT) technology is used for non-invasive bypass graft assessment 7 days after surgery. CT investigation shown two regions with severe shape remodelling first is an elbow type contortion and second is a severe curvature with tortuous area reduction. In conclusion, the helical flow induced by vessel torsion may stabilize the blood flow in the distal part of the SVG, reducing the flow disturbance and suppressing the flow separation, but in the distal end of the graft, promote the inflammatory processes in the vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure of a Deformed Inhomogeneous Material on the Data of Acoustic Emission and X-Ray Computer Microtomography

Accumulation of defects at various stages of the deformation of a structurally inhomogeneous material (granite) has been studied using two nondestructive methods: acoustic emission (AE) and X-ray computer microtomorgaphy (CT). The quasi-static testing of cylindrical samples of a Westerly granite was carried out under uniaxial compression. The control of the defect formation was realized using the real-time monitoring of acoustic emission. For each sample under study, several steps of the loading and tomographic imaging have been performed. We have found that an exponential or power-law function of the energy distribution of the AE signals makes it possible to select a sample region, in which the system of defects has transited into a self-organized criticality state and large cracks have been formed. This result coincides with the data of the X-ray tomography Computer Microtomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Uniaxial Compression of Cellular Materials at a 10 -1 s -1 Strain Rate Simultaneously with Synchrotron X-ray Computed Tomographic Imaging

The topic is presented as a series of slides. Motivation for the work included the following: X-ray tomography is a fantastic technique for characterizing a material’s starting structure as well as for non-destructive, in situ experiments to investigate material response; 3D X-ray tomography is needed to fully characterize the morphology of cellular materials; and synchrotron micro-CT can capture 3D images without pausing experiment. Among the conclusions reached are these: High-rate radiographic and tomographic imaging (0.25 s 3D frame rate) using synchrotron CT can capture full 3D images of hyper-elastic materials at a 10 -2 strain rate; dynamic true in situ uniaxial loading can be accurately captured; the three stages of compression can be imaged: bending, buckling, and breaking; implementation of linear modeling is completed; meshes have been imported into LANL modeling codes--testing and validation is underway and direct comparison and validation between in situ data and modeled mechanical response is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assembly, checkout, and operation optimization analysis technique for complex systems

Computerized simulation model of a launch vehicle/ground support equipment system optimizes assembly, checkout, and operation of the system. The model is used to determine performance parameters in three phases or modes - /1/ systems optimization techniques, /2/ operation analysis methodology, and /3/ systems effectiveness analysis technique.

Source record↗

Near-encounter geometry generation

Generation of near encounter spacecraft-target planet celestial geometry using two body trajectory computerized simulation

Duxbury, T. C.↗

Applied mechanics

Computerized simulation of Venus atmospheric entry by earth reentry, and test program on soil response to landing loads

Source record↗