Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Parallel Computing for the Computed-Tomography Imaging Spectrometer

This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

Lee, Seungwon↗

Human Expertise Helps Computer Classify Images

Two-domain method of computational classification of images requires less computation than other methods for computational recognition, matching, or classification of images or patterns. Does not require explicit computational matching of features, and incorporates human expertise without requiring translation of mental processes of classification into language comprehensible to computer. Conceived to "train" computer to analyze photomicrographs of microscope-slide specimens of leucocytes from human peripheral blood to distinguish between specimens from healthy and specimens from traumatized patients.

Rorvig, Mark E.↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

Block segmentation in feature space for realtime object detection in high granularity images

Computer vision has applications in object detection, image recognition and classification, and object tracking. One of the challenges of computer vision is the presence of useful information at multiple distance scales. Filtering techniques may sacrifice details at small scales in order to prioritize the analysis of large-scale features of the image. We present a strategy for coarse-graining multidimensional data while maintaining fine-grained detail for subsequent analysis. The algorithm is based on fixed-size block segmentation in the feature space. We apply this strategy to solve the long-standing challenge of detecting particle trajectories at the Large Hadron Collider in real time.

Computer vision↗

Angled slit design for computed tomographic imaging of electron beams

Computed tomographic method and apparatus includes an electron or ion beam having a beam axis, a refractory metal disk; at least one slit in the refractory metal disk that receive the beam, wherein the slit is at an angle to the beam axis; a beam entrance opening in the slit that allows the beam to enter; an effective beam exit opening in the slit that allow the beam to exit, wherein the beam effective exit opening is smaller than the beam entrance opening; and a system for moving the beam across the refractory metal disk, wherein the beam enters the slit through the beam entrance opening and exits the slit through the effective beam exit opening; and a computed tomographic device for measuring the beam that enters and exits the slit for analyzing the beam.

Elmer, John W.↗

Computational Ghost Imaging for Remote Sensing

This work relates to the generic problem of remote active imaging; that is, a source illuminates a target of interest and a receiver collects the scattered light off the target to obtain an image. Conventional imaging systems consist of an imaging lens and a high-resolution detector array [e.g., a CCD (charge coupled device) array] to register the image. However, conventional imaging systems for remote sensing require high-quality optics and need to support large detector arrays and associated electronics. This results in suboptimal size, weight, and power consumption. Computational ghost imaging (CGI) is a computational alternative to this traditional imaging concept that has a very simple receiver structure. In CGI, the transmitter illuminates the target with a modulated light source. A single-pixel (bucket) detector collects the scattered light. Then, via computation (i.e., postprocessing), the receiver can reconstruct the image using the knowledge of the modulation that was projected onto the target by the transmitter. This way, one can construct a very simple receiver that, in principle, requires no lens to image a target. Ghost imaging is a transverse imaging modality that has been receiving much attention owing to a rich interconnection of novel physical characteristics and novel signal processing algorithms suitable for active computational imaging. The original ghost imaging experiments consisted of two correlated optical beams traversing distinct paths and impinging on two spatially-separated photodetectors: one beam interacts with the target and then illuminates on a single-pixel (bucket) detector that provides no spatial resolution, whereas the other beam traverses an independent path and impinges on a high-resolution camera without any interaction with the target. The term ghost imaging was coined soon after the initial experiments were reported, to emphasize the fact that by cross-correlating two photocurrents, one generates an image of the target. In CGI, the measurement obtained from the reference arm (with the high-resolution detector) is replaced by a computational derivation of the measurement-plane intensity profile of the reference-arm beam. The algorithms applied to computational ghost imaging have diversified beyond simple correlation measurements, and now include modern reconstruction algorithms based on compressive sensing.

Erkmen, Baris I.↗

Solar physics applications of computer graphics and image processing

Computer graphics devices coupled with computers and carefully developed software provide new opportunities to achieve insight into the geometry and time evolution of scalar, vector, and tensor fields and to extract more information quickly and cheaply from the same image data. Two or more different fields which overlay in space can be calculated from the data (and the physics), then displayed from any perspective, and compared visually. The maximum regions of one field can be compared with the gradients of another. Time changing fields can also be compared. Images can be added, subtracted, transformed, noise filtered, frequency filtered, contrast enhanced, color coded, enlarged, compressed, parameterized, and histogrammed, in whole or section by section. Today it is possible to process multiple digital images to reveal spatial and temporal correlations and cross correlations. Data from different observatories taken at different times can be processed, interpolated, and transformed to a common coordinate system.

Altschuler, M. D.↗

Monitoring The Execution Of A VAX Image

Computer program PROCSCAN developed to monitor profile of executable image during execution. Purpose to identify routines in which program is spending most of its time. PROSCAN very useful first step in optimization of program. PROSCAN samples program counter of executing image and compares its value to table of entry-point addresses to determine which subroutine is executing. Written in C (77 percent), Assembler (13 percent), and FORTRAN 77 (10 percent).

Scott, Peter J.↗

Single-lens computed tomography imaging spectrometer and method of capturing spatial and spectral information

Computed tomography imaging spectrometers ("CTISs") employing a single lens are provided. The CTISs may be either transmissive or reflective, and the single lens is either configured to transmit and receive uncollimated light (in transmissive systems), or is configured to reflect and receive uncollimated light (in reflective systems). An exemplary transmissive CTIS includes a focal plane array detector, a single lens configured to transmit and receive uncollimated light, a two-dimensional grating, and a field stop aperture. An exemplary reflective CTIS includes a focal plane array detector, a single mirror configured to reflect and receive uncollimated light, a two-dimensional grating, and a field stop aperture.

Wilson, Daniel W.↗

The analysis of high spatial resolution UV and X-ray images by computational modeling

Very high resolution stereoscopic images of high temperature loop structures observed at UV and X-ray wavelengths in the solar corona can be used to understand physical processes in the corona. An existing computational model is described and sample results are given to demonstrate that computational modeling of coronal structures can indeed take advantage of very high resolution images. The sample results include the run of temperature and number density along a typical loop and the variation of the differential emission measure with temperature. The integration of the differential emission measure with temperature along a column commensurate with an instrument's spatial resolution is the relevant parameter obtained from UV and X-ray observations. The effects of loop geometry and energy input are examined.

Vesecky, J. F.↗

Workstation-based preprocessing of IRAS sky-flux images

Computer algorithms to remove two types of degradations in IRAS sky-flux images, namely slowly varying background illumination (strongly effected by the presence of zodiacal light) and periodic stripes, are presented. This paper discusses both algorithms in detail and shows results of its use on various sky-flux images. Focus of the work was on the implementation within a workstation environment, and its value as a preprocessing tool for researchers. Speed of the process, usability of the programs, and correctness of the results were the main goals in developing these tools.

Domik, Gitta↗

Fabrication of a Point-Like Transmission Target for Reducing Computed Tomography Imaging Artifacts

In this study, we address the challenge of enhancing image quality and spatial resolution in computed tomography (CT) imaging by introducing simulation and fabrication of high aspect ratio, point-like transmission targets. Utilizing advanced electroplating techniques, traditionally employed in the fabrication of Through Substrate Via (TSV) interconnects for CMOS circuitry, we successfully embed copper targets within silicon substrates. This method allows us to create high-aspect-ratio features specifically designed for X-ray transmission targets, resulting in micro targets that exhibit a volume increase compared to conventional evaporated surface targets. Furthermore, we present simulation results of the X-ray spectrum generated by these targets, demonstrating their potential to significantly improve both image quality and spatial resolution in CT applications. Our findings suggest that leveraging advanced fabrication techniques can open new avenues for the development of enhanced imaging technologies in medical diagnostics and beyond.

47 OTHER INSTRUMENTATION↗

Examination of Scanning Electron Microscope and Computed Tomography Images of PICA

Micrographs of PICA (Phenolic Impregnated Carbon Ablator) taken using a Scanning Electron Microscope (SEM) and 3D images taken with a Computed Tomography (CT) system are examined. PICA is a carbon fiber based composite (Fiberform ) with a phenolic polymer matrix. The micrographs are taken at different surface depths and at different magnifications in a sample after arc jet testing and show different levels of oxidative removal of the charred matrix (Figs 1 though 13). CT scans, courtesy of Xradia, Inc. of Concord CA, were captured for samples of virgin PICA, charred PICA and raw Fiberform (Fig. 14). We use these images to calculate the thermal conductivity (TC) of these materials using correlation function (CF) methods. CF methods give a mathematical description of how one material is embedded in another and is thus ideally suited for modeling composites like PICA. We will evaluate how the TC of the materials changes as a function of surface depth. This work is in collaboration with ETH-Zurich, which has expertise in high temperature materials and TC modeling (including CF methods).

Lawson, John W.↗