Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Genomic Features of Antimicrobial Resistance in Staphylococcus pseudintermedius Isolated from Dogs with Pyoderma in Argentina and the United States: A Comparative Study

Staphylococcus pseudintermedius is the most common opportunistic pathogen in dogs and methicillin resistance (MRSP) has been identified as an emerging problem in canine pyoderma. Here, we evaluated the antimicrobial resistance (AMR) features and phylogeny of S. pseudintermedius isolated from canine pyoderma cases in Argentina (n = 29) and the United States (n = 29). 62% of isolates showed multi-drug resistance. The AMR genes found: mecA, blaZ, ermB, dfrG, catA, tetM, aac(6')-aph(2"), in addition to tetK and lnuA (only found in U.S. isolates). Two point mutations were detected: grlA(S80I)-gyrA(S84L), and grlA(D84N)-gyrA(S84L) in one U.S. isolate. A mutation in rpoB (H481N) was found in two isolates from Argentina. SCCmec type III, SCCmec type V, ΨSCCmec 57395 were identified in the Argentinian isolates; and SCCmec type III, SCCmec type IVg, SCCmec type V, and SCCmec type VII variant in the U.S. cohort. Sequence type (ST) ST71 belonging to a dominant clone was found in isolates from both countries, and ST45 only in Argentinian isolates. This is the first study to comparatively analyze the population structure of canine pyoderma-associated S. pseudintermedius isolates in Argentina and in the U.S. It is important to maintain surveillance on S. pseudintermedius populations to monitor AMR and gain further understanding of its evolution and dissemination.

60 APPLIED LIFE SCIENCES↗

Crossing The Gap Using Variational Quantum Eigensolver: A Comparative Study

Within the evolving domain of quantum computational chemistry, the Variational Quantum Eigensolver (VQE) has been developed to explore not only the ground state but also the excited states of molecules. In this study, we compare the performance of Variational Quantum Deflation (VQD) and Subspace-Search Variational Quantum Eigensolver (SSVQE) methods in determining the low-lying excited states of $LiH$. Our investigation reveals that while VQD exhibits a slight advantage in accuracy, SSVQE stands out for its efficiency, allowing the determination of all low-lying excited states through a single parameter optimization procedure. We further evaluate the effectiveness of optimizers, including Gradient Descent (GD), Quantum Natural Gradient (QNG), and Adam optimizer, in obtaining $LiH$'s first excited state, with the Adam optimizer demonstrating superior efficiency in requiring the fewest iterations. Moreover, we propose a novel approach combining Folded Spectrum VQE (FS-VQE) with either VQD or SSVQE, enabling the exploration of highly excited states. We test the new approaches for finding all three $H_4$'s excited states. Folded Spectrum SSVQE (FS-SSVQE) can find all three highly excited states near $-1.0$ Ha with only one optimizing procedure, but the procedure converges slowly. In contrast, although Folded spectrum VQD (FS-VQD) gets highly excited states with individual optimizing procedures, the optimizing procedure converges faster.

Chen, I-Chi↗

SU-E-T-246: Detector Selection for Small Field Measurements, a Comparative Study

Purpose: To compare commercially available detectors for small field dosimetry. Methods: PTW (Freiburg, Germany) diode E, PTW microDiamond, and SunNuclear (Melbourne, FL) Edge detector were used to measure output factors, PDD, and profiles on a Varian iX linear accelerator (Varian Medical Systems, Palo Alto, CA) using 6MV and 18MV photon beams. The water tank was set to 100cm SSD. Centering profiles at 5cm and 20cm depth confirmed an offset <0.1mm. High resolution PDD (0.1mm) aligned the collecting volume at water surface. For setup and linearity verification, PDD and profiles were matched to annual measurements, which were performed with an A1SL ion chamber.Scans were taken for 6X and 18X, for 10cmx10cm, 10cmx2cm, 10cmx1cm, and 10cmx0.5cm fields. Profiles were measured at Dmax (6X=1.5cm, 18X=3.5cm), 5cm, 10cm, and 20cm depths. All fields used 10cmx10cm jaws with the MLC defining the field in the X-direction. PDDs used 2mm step size and 0.2s discrete collecting time. Profiles used 1mm step size and a 0.4s discrete collecting time. Results: The PTW diode E and Edge detector exhibit centering stability, but all detectors require vertical shifts from Vendor defined vertical alignment. Output factor measurements reveal good agreement between detectors. The Edge detector demonstrates the sharpest penumbra and the closest consistent match to ion chamber measurements in the out of field regions for 6MV (3.2%). Each detector provides comparable curve quality for PDDs, with a maximum difference across detectors giving a standard deviation of 0.6% at 30cm depth, 18X, and 10cmx0.5cm. Profiles match closely across all detectors, depths, energies, and field sizes. The microDiamond detector produces the largest penumbra width, largest deviation from ion chamber dose in the tail region for 6MV, and exhibits centering instability. Conclusion: Based on our findings, the Edge detector was chosen for stereotactic measurements. The PTW diode E is an acceptable alternative.

60 APPLIED LIFE SCIENCES↗

SU-F-P-46: Comparative Study Between Two Normalization Prescriptions for Accelerated Partial Breast Irradiation: A Dosimetric Study

Purpose: To compare the Accelerated Partial Breast Irradiation (APBI) plan with the normalized basal dose points and 5mm box prescription. Methods: Five patients of APBI were planned twice in Oncentra Master planning TPS (Version 4.3) using TG-43 algorithm. The number of catheters for all the patients was 10 to 16 and implant plane 2 to 3. For planning all catheters were reconstructed. Source loading was done as per HR-CTV contoured. The HR-CTV volume range was from 75cc to 182cc. Plans were normalized in two methods. First all plans were normalized on Basal dose points (PlanA) and second all the plan were normalized on 5mm box (PlanB). The prescription dose (PD) was 35Gy in 10 fractions. All the plans were completely based on normalization and without optimization. Plan evaluation was based on certain parameters coverage Index (CI), dose homogeneity index (DHI), conformity index (COIN), over dose volume index (OI). Results: The average and median of CI for planA was 0.835 and 0.8154, for planB 0.82 and 0.799 respectively. The median and average of DHI for planA was 0.66 and 0.6062, for planB 0.67 and 0.62 respectively. The range of COIN for planA and planB was from 0.58 to 0.65 respectively. The range of OI was from 0.083 to 0.169 for planA and planB. The treatment time in planA was in average 1.13 times more than planB as V150% of HR-CTV in planA was 4–6% more. The ipsilateral lung was getting 30% of PD which was 0.6% to 3.5%. Conclusion: Treatment Planning should be individualized based on implants characteristics. Planning with prescription to basal dose points should be preferred to 5mm box prescription, in order to achieve better DHI and less treatment time.

60 APPLIED LIFE SCIENCES↗

Comparative studies of industrial grade carbon black powders

Comparative studies of two dissimilar industrial grade Carbon Black (CB) powders (N375 and N405) were conducted. The structure, surface area and particle size are the three important characteristics of CB powder that determine their processability and application as filler in preparing rubber compounds. The powders were characterized for their structure using dibutyl phthalate absorption (DBPA), particle size via laser particle size analyzer and surface area by nitrogen adsorption method. The structural characterization showed that N405 had lower DBPA in comparison to N375, confirming low structure of N405 grade CB powder. It was observed from the particle size analysis that N375 was coarser than N405 grade CB. The total surface area values were determined by the BET method based on the cross sectional area of the nitrogen molecule. N375, a coarse grade CB powder with high structure, depicted less surface area as compared to N405.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surrogate Modeling of Nonlinear Dynamic Systems: A Comparative Study

Surrogate models play a vital role in overcoming the computational challenge in designing and analyzing nonlinear dynamic systems, especially in the presence of uncertainty. This paper presents a comparative study of different surrogate modeling techniques for nonlinear dynamic systems. Four surrogate modeling methods, namely, Gaussian process (GP) regression, a long short-term memory (LSTM) network, a convolutional neural network (CNN) with LSTM (CNN-LSTM), and a CNN with bidirectional LSTM (CNN-BLSTM), are studied and compared. All these model types can predict the future behavior of dynamic systems over long periods based on training data from relatively short periods. The multi-dimensional inputs of surrogate models are organized in a nonlinear autoregressive exogenous model (NARX) scheme to enable recursive prediction over long periods, where current predictions replace inputs from the previous time window. Three numerical examples, including one mathematical example and two nonlinear engineering analysis models, are used to compare the performance of the four surrogate modeling techniques. The results show that the GP-NARX surrogate model tends to have more stable performance than the other three deep learning (DL)-based methods for the three particular examples studied. The tuning effort of GP-NARX is also much lower than its deep learning-based counterparts.

42 ENGINEERING↗

Comparative study of laminar and turbulent flow model with different operating parameters for radio frequency-inductively coupled plasma torch working at 3 MHz frequency at atmospheric pressure

This paper provides 2D comparative study of results obtained using laminar and turbulent flow model for RF (radio frequency) Inductively Coupled Plasma (ICP) torch. The study was done for the RF-ICP torch operating at 50 kW DC power and 3 MHz frequency located at BARC. The numerical modeling for this RF-ICP torch is done using ANSYS software with the developed User Defined Function. A comparative study is done between laminar and turbulent flow model to investigate how temperature and flow fields change when using different operating conditions such as (a) swirl and no swirl velocity for sheath gas flow rate, (b) variation in sheath gas flow rate, and (c) variation in plasma gas flow rate. These studies will be useful for different material processing applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complete synchronization of uncertain chaotic systems via a single proportional adaptive controller: A comparative study

This paper addresses a comparative computational study on the synchronization quality, cost and converging speed for two pairs of identical chaotic and hyperchaotic systems with unknown time-varying parameters. It is assumed that the unknown time-varying parameters are bounded. Based on the Lyapunov stability theory and using the adaptive control method, a single proportional controller is proposed to achieve the goal of complete synchronizations. Accordingly, appropriate adaptive laws are designed to identify the unknown time-varying parameters. The designed control strategy is easy to implement in practice. Numerical simulations results are provided to verify the effectiveness of the proposed synchronization scheme.

42 ENGINEERING↗

A comparative study of hyperon equations of state in supernova simulations

A comparative study of the Λ hyperon equations of state of Banik, Hempel and Banyopadhyay (BHB), Banik et al., and Shen et al. (denoted as HShen Λ) for core-collapse supernova (CCSN) simulations is carried out in this work. The dynamical evolution of a protoneutron star (PNS) into a black hole is investigated in CCSN simulations in the general relativistic one-dimensional code using the BHBΛϕ and HShen Λ equation of state (EOS) tables and different progenitor models from Woosley and Heger. Radial profiles of the mass fractions of baryons, the density, as well as the temperature in the PNS at different moments in time, are compared for both EOS tables. The behavior of the central density of the PNS with time is demonstrated for these two Λ hyperon EOS tables and compared with their corresponding nuclear EOS tables. It is observed that the black hole formation time is higher in the BHBΛϕ case than in the HShen Λ EOS case for the entire set of progenitor models adopted here, because the repulsive Λ–Λ interaction makes the BHBΛϕ EOS stiffer. Neutrino emission with the Λ hyperon EOS ceases earlier than that of its nuclear counterpart. The long-duration evolution of the shock radius and the gravitational mass of the PNS after a successful supernova explosion with enhanced neutrino heating are studied with the BHBΛϕ EOS and s20WH07 progenitor model. The PNS is found to remain stable for 4 s and might evolve into a cold neutron star.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative studies of 2HDMs under the Higgs boson precision measurements

We perform comparative studies for four types of the two Higgs Doublet Models (2HDMs) under the precision measurements of the Standard Model (SM) Higgs observables at the proposed Higgs factories. We explore the discovery potential based on the hypothetical deviations in the precision data for the 2HDMs up to one-loop level. We find 5σ observability from the χ2 fitting in a significant theory parameter space at future Higgs factories. For the Type-I 2HDM, regions with cos(β - α) ≲ -0.1 or cos(β - α) ≳ 0.08 are discoverable at more than 5σ level. For the other three types of 2HDMs, the 5σ region is even bigger: | cos(β - α)| ≳ 0.02 for tan β ~ 1. At small and large values of tan β, the region in cos(β - α) is further tightened. We examine the extent to which the different 2HDM theories may be distinguishable from one to the other at the 95% Confidence Level with four benchmark points as case studies. We show that a large part of the parameter space of the other types of 2HDMs can be distinguished from the benchmark points of the target model. The impacts of loop corrections are found to be significant in certain parameter regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of the mechanical properties of nanostructured thin films on stretchable substrates

Comparative studies of the mechanical behavior between copper, tungsten, and W/Cu nanocomposite based on copper dispersoïd thin films were performed under in-situ controlled tensile equi-biaxial loadings using both synchrotron X-ray diffraction and digital image correlation techniques. The films first deform elastically with the lattice strain equal to the true strain given by digital image correlation measurements. The Cu single thin film intrinsic elastic limit of 0.27% is determined below the apparent elastic limit of W and W/Cu nanocomposite thin films, 0.30% and 0.49%, respectively. This difference is found to be driven by the existence of as-deposited residual stresses. Above the elastic limit on the lattice strain-true strain curves, we discriminate two different behaviors presumably footprints of plasticity and fracture. The Cu thin film shows a large transition domain (0.60% true strain range) to a plateau with a smooth evolution of the curve which is associated to peak broadening. In contrast, W and W/Cu nanocomposite thin films show a less smooth and reduced transition domain (0.30% true strain range) to a plateau with no peak broadening. These observations indicate that copper thin film shows some ductility while tungsten/copper nanocomposites thin films are brittle. Fracture resistance of W/Cu nanocomposite thin film is improved thanks to the high compressive residual stress and the elimination of the metastable β-W phase.

36 MATERIALS SCIENCE↗

A comparative study for Hydrogen storage in metal decorated graphyne nanotubes and graphyne monolayers

A comparative study for hydrogen storage in metal decorated graphyne nanotubes and graphyne monolayers has been investigated within the framework of first-principle calculations. Our results show that the binding energies of Li, Ca, Sc, Ti on graphyne nanotubes are stronger than that on graphyne monolayers. Such strong binding would prevent the formation of metal clusters on graphyne nanotubes. From the charge transfer and partial density of states, it is found that the curvature effect of nanotubes plays an important role for the strong binding strength of metal on graphyne nanotubes. And the hydrogen storage capacity is 4.82 wt%, 5.08 wt%, 4.88 wt%, 4.76 wt% for Li, Ca, Sc, Ti decorated graphyne nanotubes that promise a potential material for storing hydrogen. - Graphical abstract: Metal atoms (Li, Ca, Sc and Ti) can strongly bind to graphyne nanotubes to avoid the formation of metal clusters, and a capacity of Ca@graphyne nanotube is 5.08 wt% which is close to the requirement of DOE in 2015. Twenty-four hydrogen molecules absorb to Ti-decorated graphyne nanotube. - Highlights: • The binding strength for metal on graphyne nanotubes is much stronger than that on γ-graphyne monolayer. • Metal atoms can strongly bind to the curving triangle acetylenes rings to avoid the formation of metal clusters. • A capacity of Ca@graphyne nanotube is 5.08 wt% which is close to the requirement of DOE in 2015.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRANSIENT GALACTIC COSMIC-RAY MODULATION DURING SOLAR CYCLE 24: A COMPARATIVE STUDY OF TWO PROMINENT FORBUSH DECREASE EVENTS

Forbush decrease (FD) events are of great interest for transient galactic cosmic-ray (GCR) modulation study. In this study, we perform comparative analysis of two prominent Forbush events during cycle 24, occurring on 2012 March 8 (Event 1) and 2015 June 22 (Event 2), utilizing the measurements from the worldwide neutron monitor (NM) network. Despite their comparable magnitudes, the two Forbush events are distinctly different in terms of evolving GCR energy spectrum and energy dependence of the recovery time. The recovery time of Event 1 is strongly dependent on the median energy, compared to the nearly constant recovery time of Event 2 over the studied energy range. Additionally, while the evolutions of the energy spectra during the two FD events exhibit similar variation patterns, the spectrum of Event 2 is significantly harder, especially at the time of deepest depression. These difference are essentially related to their associated solar wind disturbances. Event 1 is associated with a complicated shock-associated interplanetary coronal mass ejection (ICME) disturbance with large radial extent, probably formed by the merging of multiple shocks and transient flows, and which delivered a glancing blow to Earth. Conversely, Event 2 is accompanied by a relatively simple halo ICME with small radial extent that hit Earth more head-on.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative studies of actinide and sub-actinide fission cross section calculation from MCNP6 and TALYS

Comparative studies of actinide and sub-actinide fission cross section calculation from MCNP6 and TALYS have been conducted. In this work, fission cross section resulted from MCNP6 prediction will be compared with result from TALYS calculation. MCNP6 with its event generator CEM03.03 and LAQGSM03.03 have been validated and verified for several intermediate and heavy nuclides fission reaction data and also has a good agreement with experimental data for fission reaction that induced by photons, pions, and nucleons at energy from several ten of MeV to about 1 TeV. The calculation that induced within TALYS will be focused mainly to several hundred MeV for actinide and sub-actinide nuclides and will be compared with MCNP6 code and several experimental data from other evaluator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-526: A Comparative Study On Gating Efficiency of Varian RPM Device and Calypso System

Purpose: In general, the linear accelerator is gated using respiratory signal obtained by way of external sensors to account for the breathing motion during radiotherapy. One of the commonly used gating devices is the Varian RPM device. Calypso system that uses electromagnetic tracking of implanted or surface transponders could also be used for gating. The aim of this study is to compare the gating efficiency of RPM device and the calypso system by phantom studies. Methods: An ArcCheck insert was used as the phantom with a Gafchromic film placed in its holder. The ArcCheck insert was placed on a Motion Sim platform and moved in the longitudinal direction simulating a respiratory motion with a period of 5 seconds and amplitude of ±6mm. The Gafchromic film was exposed to a 2 × 2cm{sup 2} field, i) with the phantom static, ii) phantom moving but ungated iii) gated with gating window of 2mm and 3mm. This was repeated with Calypso system using surface transponders with the same gating window. The Gafchromic films were read with an EPSON 11000 flatbed scanner and analysed with ‘Medphysto’ software. Results: The full width at half maximum (FWHM) as measured with film at the level of the film holder was 1.65cm when the phantom was static. FWHM measured with phantom moving and without gating was 1.16 cm and penumbra was 7 mm (80–20%) on both sides. When the beam was gated with 2 mm gating window the FWHM was 1.8 cm with RPM device and 1.9 cm with Calypso. Similarly, when the beam was gated with 3 mm window, the FWHM was 1.9cm with RPM device and 2cm with Calypso. Conclusion: This work suggests that the gating efficiency of RPM device is better than that of the Calypso with surface transponder, with reference to the latency in gating.

60 APPLIED LIFE SCIENCES↗

A comparative study of three-terminal Hanle signals in CoFe/SiO{sub 2}/n{sup +}-Si and Cu/SiO{sub 2}/n{sup +}-Si tunnel junctions

We performed three-terminal (3T) Hanle measurement for two types of sample series, CoFe/SiO{sub 2}/n{sup +}-Si and Cu/SiO{sub 2}/n{sup +}-Si, with various tunnel resistances. Clear Hanle signal and anomalous scaling between spin resistance-area product and tunnel resistance-area product were observed in CoFe/SiO{sub 2}/n{sup +}-Si devices. In order to explore the origin of the Hanle signal and the impurity-assisted tunneling effect on the Hanle signal in our devices, Hanle measurement in Cu/SiO{sub 2}/n{sup +}-Si devices was performed as well. However, no detectable Hanle signal was observed in Cu/SiO{sub 2}/n{sup +}-Si, even though a lot of samples with various tunnel resistances were studied in wide temperature and bias voltage ranges. Through a comparative study, it is found that the impurity-assisted tunneling magnetoresistance mechanism would not play a dominant role in the 3T Hanle signal in CoFe/SiO{sub 2}/n{sup +}-Si tunnel junctions, where the SiO{sub 2} was formed by plasma oxidation to minimize impurities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of electrical breakdown properties of deionized water and heavy water under pulsed power conditions

A comparative study of electrical breakdown properties of deionized water (H{sub 2}O) and heavy water (D{sub 2}O) is presented with two different electrode materials (stainless steel (SS) and brass) and polarity (positive and negative) combinations. The pulsed (∼a few tens of nanoseconds) discharges are conducted by applying high voltage (∼a few hundred kV) pulse between two hemisphere electrodes of the same material, spaced 3 mm apart, at room temperature (∼26-28 °C) with the help of Tesla based pulse generator. It is observed that breakdown occurred in heavy water at lesser voltage and in short duration compared to deionized water irrespective of the electrode material and applied voltage polarity chosen. SS electrodes are seen to perform better in terms of the voltage withstanding capacity of the liquid dielectric as compared to brass electrodes. Further, discharges with negative polarity are found to give slightly enhanced discharge breakdown voltage when compared with those with positive polarity. The observations corroborate well with conductivity measurements carried out on original and post-treated liquid samples. An interpretation of the observations is attempted using Fourier transform infrared measurements on original and post-treated liquids as well as in situ emission spectra studies. A yet another important observation from the emission spectra has been that even short (nanosecond) duration discharges result in the formation of a considerable amount of ions injected into the liquid from the electrodes in a similar manner as reported for long (microseconds) discharges. The experimental observations show that deionised water is better suited for high voltage applications and also offer a comparison of the discharge behaviour with different electrodes and polarities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparative study of satellite estimation for solar insolation in Albania with ground measurements

The main objective of this study is to compare data provided by Database of NASA with available ground data for regions covered by national meteorological net NASA estimates that their measurements of average daily solar radiation have a root-mean-square deviation RMSD error of 35 W/m{sup 2} (roughly 20% inaccuracy). Unfortunately valid data from meteorological stations for regions of interest are quite rare in Albania. In these cases, use of Solar Radiation Database of NASA would be a satisfactory solution for different case studies. Using a statistical method allows to determine most probable margins between to sources of data. Comparison of mean insulation data provided by NASA with ground data of mean insulation provided by meteorological stations show that ground data for mean insolation results, in all cases, to be underestimated compared with data provided by Database of NASA. Converting factor is 1.149.

14 SOLAR ENERGY↗