[Biooptical properties of marine phytoplankton as they apply to satellite remote sensing]

This final report covers research performed over a period of 10 years from 1982 to 1992. During this time, Grant #NAGW410 was funded under three titles through a series of Supplements. The original proposal was entitled 'Photoecology, optical properties and remote sensing of warm core rings'; the second and major portion was entitled 'Continuation of studies of biooptical properties of phytoplankton and the study of mesoscale and submesoscale features using fluorescence and colorimetry'; with the final portion named 'Studies of biooptical properties of phytoplankton, with reference to identification of spectral types associated with meso- and submesoscale features in the ocean'. The focus of these projects was to try to expand our knowledge of the biooptical properties of marine phytoplankton as they apply to satellite remote sensing. We used a variety of techniques, new and old, to better measure these optical properties at appropriate scales, in some cases at the level of individual cells. We also exploited the specialized oceanic conditions that occur within certain regions and features of the ocean around the world in order to explain the tremendous variability one sees in a single remote sensing image. This document strives to provide as complete a summary as possible for this large body of work, including the pertinent publications supported by this funding.

Yentsch, Charles S.↗

Observations of Planet Crossing Asteroids

This grant funds the investigation of the Solar System's planet crossing asteroid population, principally the near Earth and trans-Neptunian objects, but also the Centaurs. Investigations include colorimetry at both visible and near infrared wavelengths, light curve photometry, astrometry, and a pilot project to find near Earth objects with small aphelion distances, which requires observations at small solar elongations.

Tholen, David J.↗

Observations of Planet Crossing Asteroids

The goals of this research were the physical and dynamical characterization of planet crossing asteroids (Earth crossers, Mars crossers, Centaurs, and Pluto crossers, meaning trans-Neptunian objects), including colorimetry, rotational studies, and astrometry. Highlights are listed as follows: 1) Produced one doctoral dissertation (R. J. Whiteley, A Compositional and Dynamical Survey of the Near-Earth Asteroids). A key result is the fraction of Q-type asteroids among the near-Earth population was found to be about one-third; 2) Had prediscovery image showing the binary nature of trans-Neptunian object 1998 WW31, which is the first TNO to have a satellite found in orbit around it; 3) Discovery of shortest known rotation period for any asteroid (2000 D08, rotation period 78 seconds); it is just one of several fast-rotating small asteroids observed during the course of this project; 4) Discovery of a Centaur asteroid (1998 QM107) with, at the time, the smallest known orbital eccentricity among the Centaurs (0.13) and nearly in a 1:1 resonance with Uranus (semimajor axis of 19.9 AU); 5) Discovery of Apollo-type asteroid 1999 OW3, with a surprisingly bright absolute magnitude of 14.6 (estimated diameter of 4.6 km), brightest Apollo found in that calendar year; 6) Discovery of Aten-type asteroid 2000 SG344, which has the highest cumulative Earth impact probability among the near-Earth asteroids and a very Earth-similar orbit; 7) Instrumental in repairing the orbit of a numbered near-Earth asteroid for which prediscovery observations had been mis-attributed to it (2000 VN2); 8) Second-opposition recovery of 30-meter diameter Apollo-type asteroid 1998 KY26 in early 2002 when it was at a favorable magnitude of 24.8; 9) Primary contributor of astrometric observations of the CONTOUR fragments to the CONTOUR project following the failure of the spacecraft s kick motor; and 10) Development of orbit and ephemeris computation code that handles short observational arcs, observations at small solar elongations where indeterminacy is a known problem, and a small number of observations (including just two). Starting in 2000 November, the Spaceguard Central Node began prioritizing near-Earth asteroids in need of astrometric observation. Our own follow-up efforts relied on these listings, with emphasis given to the faintest objects where the combination of a 2.2-m telescope and a site with subarcsecond seeing produces a limiting magnitude close to 25, which represents a unique and valuable capability. The attached table, last updated in August, demonstrates the arc-lengthening capabilities of a faint limiting magnitude. Tabulated are the arc lengths before and after our observation(s), whether our observation is the last one available for the object in question, and the approximate magnitude of the object at the time of the observation.

Tholen, David J.↗

Solid-State Lighting Module (SSLM)

The project's goal was to build a light-emitting-diode (LED)-based light fixture that is identical in fit, form, and function to the existing International Space Station (ISS) General Luminaire Assembly (GLA) light fixture and fly it on the ISS in early FY 2008 as a Station Detailed Test Objective (SDTO). Our design offers the following strengths: proven component hardware: Our design uses components flown in other KSC-developed hardware; heat path thermal pad: LED array heat is transferred from the circuit board by silicon pad, negating the need for a cooling fan; variable colorimetry: The output light color can be changed by inserting different LED combinations.

Source record↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Aperiodic optical coatings for neutral-color semi-transparent organic photovoltaics

Semi-transparent organic photovoltaics (ST-OPVs) have the potential for integration with windows for ubiquitous power generating applications. Typically, such applications require that ST-OPVs be neutrally transparent across the visible and exhibit both a high average photopic transmittance (APT) and color rendering index, as well as iso-energetic chromaticity coordinates. In this work, we demonstrate the design and use of optical coatings to achieve ST-OPVs with a neutral visible transmittance of APT = 50%, a power conversion efficiency of 8.3%, and optical properties that are independent of a ± 30° variation in the solar angle of incidence. As a result, these simple optical coatings are rapidly designed using a genetic algorithm and transfer matrix formalism.

14 SOLAR ENERGY↗

Efficient excimer-based white OLEDs with reduced efficiency roll-off

A tetradentate Pt(II) complex, Pt2O2-p2m, which exhibits both efficient monomer and excimer emission, was synthesized. Through rational device design to broaden the recombination zone, an OLED device employing Pt2O2-p2m demonstrated an impressively high peak external quantum efficiency (EQE) of 21.5% and a warm white emission with a color rendering index of 71 and Commission Internationale de L'Eclairage coordinates of (0.409, 0.458). Moreover, a reduced efficiency roll-off was also observed to retain high EQE values of 20% EQE at 1000 cd/m 2 and 17% EQE at 5000 cd/m 2 , and an LT70 (time to 70% initial luminance) was estimated to be over 150 h at 1000 cd/m2 under constant operation at accelerated driving conditions.

36 MATERIALS SCIENCE↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗

Real-time measurements of endogenous CO production from vascular cells using an ultrasensitive laser sensor

Carbon monoxide (CO) has been implicated as a biological messenger molecule analogous to nitric oxide. A compact gas sensor based on a midinfrared laser absorption spectroscopy was developed for direct and real-time measurement of trace levels (in approximate pmol) of CO release by vascular cells. The midinfrared light is generated by difference frequency mixing of two nearinfrared lasers in a nonlinear optical crystal. A strong infrared absorption line of CO (4.61 microm) is chosen for convenient CO detection without interference from other gas species. The generation of CO from cultured vascular smooth muscle cells was detected every 20 s without any chemical modification to the CO. The sensitivity of the sensor reached 6.9 pmol CO. CO synthesis was measured from untreated control cells (0.25 nmol per 10(7) cells/h), sodium nitroprusside-treated cells (0.29 nmol per 10(7) cells/h), and hemin-treated cells (0.49 nmol per 10(7) cells/h). The sensor also detected decreases in CO production after the addition of the heme oxygenase (HO) inhibitor tin protoporphyrin-IX (from 0.49 to 0.02 nmol per 10(7) cells/h) and increases after the administration of the HO substrate hemin (from 0.27 to 0.64 nmol per 10(7) cells/h). These results demonstrate that midinfrared laser absorption spectroscopy is a useful technique for the noninvasive and real-time detection of trace levels of CO from biological tissues.

Non-NASA Center↗