Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Color Changing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Wipes, Coatings, and Patches for Detecting Hydrazines

Three color-indicating devices have been conceived as simple, rapid, inexpensive means of detecting hazardous liquid and gaseous substances in settings in which safety is of paramount concern and it would be too time-consuming or otherwise impractical to perform detection by use of such instruments as mass spectrometers. More specifically, these devices are designed for detecting hypergolic fuels (in particular, hydrazines) and hypergolic oxidizers in spacecraft settings, where occasional leakage of these substances in liquid or vapor form occurs and it is imperative to take early corrective action to minimize adverse health effects. With suitable redesign, including reformulation of their color indicator chemicals, these devices could be adapted to detection of other hazardous substances in terrestrial settings (e.g., industrial and military ones). One of the devices is a pad of a commercially available absorbent material doped with a color indicator. The absorbent material is made from 70 percent polyester and 30 percent nylon and can absorb about eight times its own weight of liquid. The color indicator is a mixture of conventional pH color indicator chemicals. Hydrazine and monomethyl hydrazine, which are basic, cause the color indicator to turn green. In the original intended application, the pad is wiped on a space suit that is suspected of having been exposed to leaking monomethyl hydrazine during a space walk, before the wearer returns to the interior of the spacecraft. If the wiped surface is contaminated with hydrazine, the pad turns green. In addition, the pad absorbs hydrazine from the wiped surface, thereby reducing or eliminating the hazard. Used pads, including ones that show contamination by hydrazine, can be stored in a sealed plastic bag for subsequent disposal. The second device, which has been proposed but not yet developed, would comprise a color indicator material in the form of either a coating on a space suit (or other protective garment) or a coating on a sheet that could be easily attached to and detached from the protective garment. The coating material would be a hydrogel doped with a suitable pH indicator. The hydrogel would also serve to maintain a level of moisture needed to support the chemical reaction mentioned in the next sentence. In addition to changing color to indicate the presence of any hypergolic fuel (which is basic) or hypergolic oxidizer (which is acidic) that might splash on the space suit, the pH indicator would also react with the hypergolic fuel or oxidizer and thereby bind it. The third device is a color dosimeter for detecting hydrazine liquid or vapor coming from microscopic leaks. This device is designed to satisfy several requirements specific to its original intended use in the auxiliary power unit of the space shuttle. These requirements include stability under vacuum, stability at moderate temperature, fast and irreversible change in color upon exposure to hydrazine, and visibility of the color change through polyimide tape.

Young, Rebecca↗

Temperature-Sensitive Coating Sensor Based on Hematite

A temperature-sensitive coating, based on hematite (iron III oxide), has been developed to measure surface temperature using spectral techniques. The hematite powder is added to a binder that allows the mixture to be painted on the surface of a test specimen. The coating dynamically changes its relative spectral makeup or color with changes in temperature. The color changes from a reddish-brown appearance at room temperature (25 C) to a black-gray appearance at temperatures around 600 C. The color change is reversible and repeatable with temperature cycling from low to high and back to low temperatures. Detection of the spectral changes can be recorded by different sensors, including spectrometers, photodiodes, and cameras. Using a-priori information obtained through calibration experiments in known thermal environments, the color change can then be calibrated to yield accurate quantitative temperature information. Temperature information can be obtained at a point, or over an entire surface, depending on the type of equipment used for data acquisition. Because this innovation uses spectrophotometry principles of operation, rather than the current methods, which use photoluminescence principles, white light can be used for illumination rather than high-intensity short wavelength excitation. The generation of high-intensity white (or potentially filtered long wavelength light) is much easier, and is used more prevalently for photography and video technologies. In outdoor tests, the Sun can be used for short durations as an illumination source as long as the amplitude remains relatively constant. The reflected light is also much higher in intensity than the emitted light from the inefficient current methods. Having a much brighter surface allows a wider array of detection schemes and devices. Because color change is the principle of operation, the development of high-quality, lower-cost digital cameras can be used for detection, as opposed to the high-cost imagers needed for intensity measurements with the current methods. Alternative methods of detection are possible to increase the measurement sensitivity. For example, a monochrome camera can be used with an appropriate filter and a radiometric measurement of normalized intensity change that is proportional to the change coating temperature. Using different spectral regions yields different sensitivities and calibration curves for converting intensity change to temperature units. Alternatively, using a color camera, a ratio of the standard red, green, and blue outputs can be used as a self-referenced change. The blue region (less than 500 nm) does not change nearly as much as the red region (greater than 575 nm), so a ratio of color intensities will yield a calibrated temperature image. The new temperature sensor coating is easy to apply, is inexpensive, can contour complex shape surfaces, and can be a global surface measurement system based on spectrophotometry. The color change, or relative intensity change, at different colors makes the optical detection under white light illumination, and associated interpretation, much easier to measure and interpret than in the detection systems of the current methods.

Bencic, Timothy J.↗

FLEXAN (version 2.0) user's guide

The FLEXAN (Flexible Animation) computer program, Version 2.0 is described. FLEXAN animates 3-D wireframe structural dynamics on the Evans and Sutherland PS300 graphics workstation with a VAX/VMS host computer. Animation options include: unconstrained vibrational modes, mode time histories (multiple modes), delta time histories (modal and/or nonmodal deformations), color time histories (elements of the structure change colors through time), and rotational time histories (parts of the structure rotate through time). Concurrent color, mode, delta, and rotation, time history animations are supported. FLEXAN does not model structures or calculate the dynamics of structures; it only animates data from other computer programs. FLEXAN was developed to aid in the study of the structural dynamics of spacecraft.

Stallcup, Scott S.↗

Corrosion-Indicating Pigment And Probes

Proposed hydrogen-sensitive paint for metal structures changes color at onset of corrosion, involving emission of hydrogen as result of electrochemical reactions. Pigment of suitable paint includes rhodium compound RhCl(PPh3)3, known as Wilkinson's catalyst. As coating on critical parts of such structures as bridges and aircraft, paint gives early warning of corrosion, and parts thus repaired or replaced before failing catastrophically. Reveals corrosion before it becomes visible to eye. Inspection for changes in color not ordinarily necessitate removal of structure from service, and costs less than inspection by x-ray or thermal neutron radiography, ultrasonic, eddy-current, or acoustic-emission techniques.

Bar-Cohen, Yoseph↗

Tracking Metabolic Changes in Microbial Culture using Redox Measurements

During long-term space missions, microbial cultures accumulate the effects of low-dose radiation, microgravity, and other factors; altered growth and metabolic activity may occur before viability effects. This could affect functionality of bioreactors or other bio-enabled mission systems, as well as shed light on human health. Spaceflight microbiology studies beyond the low Earth orbit exposure afforded by the ISS have been limited. Nanosatellites offer an increasingly popular alternative for deep space missions. However, the communications delay requires biofluidic automation of a pre-defined experimental protocol, and the lack of sample return (reliance on sensors in flight) can significantly limit feasible investigations. Previous biological CubeSats (PharmaSat, O/OREOS, EcAMSat) have used alamarBlue, an off-the-shelf formulation of the redox indicator dye resazurin, to track metabolic activity, as will BioSentinel, the upcoming interplanetary microbiology experiment. A series of ground experiments (see abstracts by Liddell, Santa Maria, and A. Kim) were conducted using a microbial culture system outfitted with an electrochemical sensor array (electrical conductivity, pH, oxidation-reduction potential, and dissolved oxygen) with alamarBlue and the same strain of Saccharomyces cerevisiae as BioSentinel. By improving mapping of measured changes in alamarBlue kinetics to physicochemical changes, and ultimately to biological alterations such as shifted metabolic pathways, this work supplements data analyses from past missions and planning for future missions using alamarBlue to characterize space radiation effects. Initial results indicate that alamarBlue acts like a redox buffer; its presence significantly changes redox kinetics in otherwise identical cultures. The initial color change (blue resazurin reduced to red/pink resorufin) appears as a redox plateau. A second plateau, likely corresponding to the second color transition (resorufin to the colorless hydroresorufin), occurs at a lower redox value. The relationship to carbon source exhaustion, dissolved oxygen depletion, cell death, and measured redox potential is complex and still under study.

Tracking↗

A video event trigger for high frame rate, high resolution video technology

When video replaces film the digitized video data accumulates very rapidly, leading to a difficult and costly data storage problem. One solution exists for cases when the video images represent continuously repetitive 'static scenes' containing negligible activity, occasionally interrupted by short events of interest. Minutes or hours of redundant video frames can be ignored, and not stored, until activity begins. A new, highly parallel digital state machine generates a digital trigger signal at the onset of a video event. High capacity random access memory storage coupled with newly available fuzzy logic devices permits the monitoring of a video image stream for long term or short term changes caused by spatial translation, dilation, appearance, disappearance, or color change in a video object. Pretrigger and post-trigger storage techniques are then adaptable for archiving the digital stream from only the significant video images.

Williams, Glenn L.↗

VLSI-based Video Event Triggering for Image Data Compression

Long-duration, on-orbit microgravity experiments require a combination of high resolution and high frame rate video data acquisition. The digitized high-rate video stream presents a difficult data storage problem. Data produced at rates of several hundred million bytes per second may require a total mission video data storage requirement exceeding one terabyte. A NASA-designed, VLSI-based, highly parallel digital state machine generates a digital trigger signal at the onset of a video event. High capacity random access memory storage coupled with newly available fuzzy logic devices permits the monitoring of a video image stream for long term (DC-like) or short term (AC-like) changes caused by spatial translation, dilation, appearance, disappearance, or color change in a video object. Pre-trigger and post-trigger storage techniques are then adaptable to archiving only the significant video images.

Williams, Glenn L.↗

Variations in color and reflectance on the surface of asteroid (101955) Bennu

Visible-wavelength color and reflectance provide information about the geologic history of planetary surfaces. Here we present multispectral images (0.44 to 0.89 micrometers) of near-Earth asteroid (101955) Bennu. The surface has variable colors overlain on a moderately blue global terrain. Two primary boulder types are distinguishable by their reflectance and texture. Space weathering of Bennu surface materials does not simply progress from red to blue (or vice versa). Instead, freshly exposed, redder surfaces initially brighten in the near-ultraviolet region (i.e., become bluer at shorter wavelengths), then brighten in the visible to near-infrared region, leading to Bennu’s moderately blue average color. Craters indicate that the time scale of these color changes is ~105 years. We attribute the reflectance and color variation to a combination of primordial heterogeneity and varying exposure ages.

D. N. DellaGiustina↗

Microminiature Monitor for Vital Electrolyte and Metabolite Levels of Astronauts

Ions, such as proton (pH) and potassium, play a crucial role in body fluids to maintain proper basic functioning of cells and tissues. Metabolites, such as glucose, control the energy available to the entire human body in normal as well as stress situations, and before, during, and after meals. These molecules diffuse easily between blood in the capillaries and the interstitial fluid residing between cells and tissues. We have developed and approach to monitoring of critical ions (called electrolytes) and glucose in the interstitial fluid under the human skin. Proton and potassium levels sensed using optode technology that translates the respective ionic concentrations into variable colors of corresponding ionophore/dye/polymeric liquid membranes. Glucose is monitored indirectly, by coupling through immobilized glucose oxidase with local pH that is then detected using a similar color scheme. The monitor consists of a tiny plastic bar, 100-200 microns wide and 1-2 mm long, placed just under the skin, with color changing spots for each analyte as well as blanks. The colors are read and translated into concentration values by a CCD camera. Direct optical coupling between the in vivo sensing bar and the ex vivo detector device requires no power, and thus eliminates the need for wires or optical fibers crossing the skin. The microminiature bar penetrates the skin easily and painlessly, so that astronauts could insert it themselves. The approach is fully compatible with telemetry in space, and thus, in vivo clinical data will be available real time in the Earth based command center once the device is fully developed. The information provided can be used for collecting hitherto unavailable vital data on clinical effects of space travel. Managing clinical emergencies in space with the sensor already in place should also become much more efficient than without a continuous monitor, as is currently the case. Civilian applications may include better glucose control of patients with moderate to severe diabetes: a growing health problem in the US and World-wide.

Tohda, Koji↗

The BioSensor Instrument Beyond LEIA: a Versatile Platform for Lunar Biology

Introduction: The BioSensor is a deep-space-compatible automated microfluidic culturing instrument. While originally designed to measure the effects of deep space radiation on yeast growth for the BioSentinel mission, it has the potential to host a diverse range of life science experiments with single- and/or multi-celled organisms and can be adapted to interface with a diverse range of platforms in both crewed and uncrewed settings. It is therefore a leading candidate for hosting life sciences experimentation associated with a lunar surface habitat. BioSensor design: The function of the BioSensor is to monitor the growth and metabolic activity of samples in batch fluidic culture, without the need for crew involvement. The current configuration houses organisms in 16 wells within 16 microfluidic cards, accommodating a total of 256 samples, replicates, and controls. Each well has an optical system including three LEDs and a photodiode detector to measure absorbance at three wavelengths, enabling measurement of optical density, color change in dyes such as alamarBlue, and bioproduction of pigmented compounds. Organisms are loaded into fluidic wells and air-dried for storage during integration, launch, and transit, then activated by the introduction of culture medium from storage bags via manifolds that fill one card at a time. Temperature is controlled by individual card heaters, and timing of all activities (fluidics fills, optical measurements, temperatures) is directed by an experiment script. The self-contained BioSensor payload is roughly 4U in volume; with electrical/mechanical/thermal interface, e.g. for operation on ISS or a lunar lander, as well as a linear energy-transfer (LET) charged-particle radiation spectrometer, the entire system is closer to 6U. BioSentinel and LEIA: Flown on the ISS and in a deep-space free flyer for BioSentinel, the BioSensor has been modified for use in the LEIA mission, including improvements to reduce the sensitivity to lengthy launch delays. LEIA will monitor yeast growth in the radiation and reduced-gravity environment of the lunar surface no earlier than 2026, on a CLPS lander [4]. Changes include accommodating additional culture media and an additional LED color for a new biological assay (bioproduction of carotenoids-- dietary antioxidants), as well as modifications to the housing to allow late-load biology changeout and improved isolation between fluidics and electronics. Future prospects: Future work with the BioSensor, beyond LEIA, will include expanding the range and diversity of organisms and assays accommodated. Preliminary work has demonstrated the growth of Arabidopsis seedlings in BioSensor fluidic cards, including optical measurements of growth rate over time. Minor modifications could allow measurement of phenotypes related to photosynthetic capacity in both plants and cyanobacteria. The experimental capabilities of the BioSensor could be dramatically increased by introducing the capability for fluorescence measurements, and/or the design of novel biological assays using luminescence. The BioSensor can also be adapted for new platforms and experiment settings; in addition to free-flyer, ISS, and CLPS lander, a preliminary design concept has been developed for crewed deployment directly to the lunar surface. The instrument could be accommodated inside a lunar habitat, where its automated operation would make it an excellent candidate for experiments from fundamental investigations into the response of organisms to lunar surface conditions to applied-science purposes such as screening engineered strains of various organisms for bioproduction capability.

J A Lee↗

Investigation of Chemically Treated Test-Strips for Ozone Measurement

A colorimetric passive ozone monitoring system is currently in use in the GLOBE project, as well as several other environmental studies, as commercially supplied as Eco-Badge by Vistanomics. This simple, but effective, system consists of papers treated with a chemical preparation, tin(II) diphenylcarbazidel that reacts with ozone to change them from white to purple. The intensity of the purple coloration is dependent on the concentration of ozone. Our previous contributions to that method of analysis involved modest modifications to the chemical substrate employed. The new formulation improved the reproducibility and linearity of the color change of treated papers.

Bush, Linda C.↗

Albedo and color contrasts on asteroid surfaces

Asteroids in general display only small or negligible variations in spectrum or albedo during a rotational cycle. Color variations with rotation are described in the literature but are usually comparable to the noise in the measurements. Twenty-four asteroids have been systematically monitored for such color changes. Only 3 Juno, 4 Vesta, 6 Hebe, 71 Niobe, 349 Dembowska, and 944 Hidalgo display color variations larger than 0.03 mag. In each of these cases the asteroid appears redder near maximum brightness. Of seven asteroids monitored polarimetrically, only 4 Vesta shows a convincing variation, attributed to an albedo change with rotation. The lightcurve can be explained by albedo differences alone; Vesta apparently has a nearly spheroidal shape. Nothwithstanding the above results, the degree of uniformity of most asteroid surfaces is remarkable. If asteroids exist with large discrete domains of ferrosilicate, metallic, and/or carbonaceous material together on their surfaces, they have not yet been identified.

Degewij, J.↗

The color of meteoritic hibonite - An indicator of oxygen fugacity

Hibonites similar in composition to those found in Ca-Al-rich inclusions change color from blue, to green, to orange, to nearly colorless as oxygen fugacity is increased at high temperature from below the iron-wustite buffer up to air. The development of the blue color is correlated with the growth of an absorption band at 715 nm in the optical spectra of the hibonites as the oxygen fugacity is reduced. The growth of this band is attributed to the increasing concentration of Ti(3+) in these hibonites with decreasing oxygen fugacity. The blue hibonites in meteorites reflect equilibration under reducing conditions based on the intensity of 715 nm band, it is estimated that the hibonite in the Blue Angel inclusion indicates an oxygen fugacity four to five orders of magnitude more oxidizing than that expected in the early solar nebula. This may be due to formation in an anomalously oxidizing region of the nebula or to oxidation during cooling or later alteration. The orange hibonites in Allende reflect oxygen fugacities approximately ten or more orders of magnitude more oxidizing than the expected primitive nebula; this color probably indicates alteration of initially more reduced (blue?) hibonites. The colorless hibonite in the HAL inclusion reflects highly oxidizing conditions and/or its low Ti content.

Ihinger, P. D.↗

Photometric evidence on long-term stability of albedo and colour markings on Io

Photometric measurements of the color and albedo of Io during the last 50 years are examined in order to determine the stability of the Ionian surface. Brightness measurements of Io relative to Ganymede show a slight, however inconclusive, increase with time, while light curve amplitudes and shapes are found to agree well during this period. The extent of volcanic activity observed by Voyager 1, however, is shown to be undetectable with the precision attainable by earth-based albedo determinations, and just barely detectable as color changes, which explains the observed photometric stability. Possible mechanisms for the preservation of the observed longitudinal distribution of color on Io are also discussed.

Morrison, D.↗

BioSentinel ISS Control Experiment Final Investigation Summary Form

Each payload has 18 fluidic cards and each fluidic card has 16 microfluidic wells, for a total of 288 wells. Card activation occurs at different time points throughout the 6-month mission and following ground commands. At each timepoint, two fluidic cards are filled with growth medium containing nutrients and a metabolic indicator dye. In addition to card filling, the temperature of the cards increases from ~4°C (stasis mode) to 23°C to allow for cell growth. The metabolic dye changes color from blue to pink, then pink to clearin the presence of metabolically active yeast cells. The colorimetric changes and cell growth are monitored using a 3-light-emitting diode(LED)optical detection system. The optical data determines how fast the cells are able to recover after accumulating radiation damage over time.After ground command initiation, all the fluidics, thermal and optical detection steps in BioSentinel are fully automated.The biosensor response data is compared to physical dosimetry data collected onboard the same payload. This dosimeter or linear energy transfer (LET)spectrometer is based on TimePix chip technology. This chip measures the total ionizing radiation dose in addition to calculating the LET of each particle that traverses its sensor, thus allowing researchers to characterize the radiation environment around the payload.The biological response (and physical dosimetry) on ISS over time is compared to the deep space mission and to data obtained on the ground.This analysis provides insight on the biological effects of the space radiation exposure in preparation for future long-duration missions to space and inhabitation beyond low-Earth orbit (LEO).

BioSentinel↗

Color contouring for atmospheric data sets

A program has been developed for use by researchers at the Langley Research Center (LaRC) to allow a quick and easy method to display color contour plots. The bilinear interpolation technique used in the contouring routine enables the user to analyze large data sets with smoothly varying color changes instead of dashes and lines. Annotations can be added to enhance the contour plot, and the resulting plot can easily be made into a color print or a viewgraph.

Ferebee, M. T.↗

Ground Testing of the MISSE-16 Materials

The harsh space environment imposes very stringent requirements upon spacecraft materials, especially those located on exterior surfaces of space objects in low Earth orbit (LEO). As humankind moves from space exploration to space commercialization, these materials may have to last for 15–20 years without considerable degradation of their optical, electrical, mechanical, and thermal properties. Operational requirements dictate that these materials continue to function according to expectations. Hence, we must understand the effects of the space environment on materials currently in use as well as on untested materials. For the years, the Materials International Space Station Experiment Flight Facility (MISSE-FF) have flown many different materials to investigate the effect of LEO space weather exposure on the performance and durability of materials and devices. The MISSE-16 scientific team members plan to launch fifteen different novel and well-characterized spacecraft-relevant materials to the LEO environment for a duration of six months during the MISSE-16 mission. Changes in spectral reflectivity will be measured throughout the mission as the samples are exposed to the space environment. The same chemical damage the produces changes in optical reflectance also causes changes in numerous other physical properties such as electrical conductivity, mechanical strength, and chemical reactivity. Correlation of the changes in each of these properties as a function of radiation type, flux, and fluence allows various material properties to be inferred from one experimentally tractable measurement: color change. Flying identical test fixtures on the ram, zenith, and wake positions of the MISSE-FF, collecting spectrally resolved images of the materials, and concomitantly measuring the ambient space environment allows deconvolution of the material effects which occur as a result of exposure to neutral atomic oxygen (AO), unfiltered solar ultraviolet (UV) radiation, and electrons. The flight experiment will function as a ground truth reference for our team’s ongoing laboratory-based space weather-material interactions experiments. Comparison of the MISSE-16 data with extensive testing of “flight-duplicate” samples under simulated space weather conditions will enable development of chemical models for prediction of material degradation. This paper discusses preliminary results from the ground test campaign including measurements of UV/VIS/IR reflectance spectra, bidirectional reflectance distribution function (BRDF), surface potential decay, and surface morphology under electron and AO exposure.

Elena A. Plis↗

Faint photometry of edge-on spiral galaxies - A search for massive halos

Upper limits have been set to the luminosity from the massive halos of three late-type edge-on spiral galaxies: NGC 2683 (Sb), NGC 4244 (Scd), and NGC 5907 (Sc). The limits resulted from simultaneous photometry in the visual (V) and 2.2-micron (K) photometric bands which is sensitive to both luminosity and color changes along the minor axes of the three galaxies. The mass-to-light ratios for the halo of NGC 5907 are the largest ever recorded: M/L(V) greater than 2000 and M/L(K) greater than 64 in solar units. The results virtually eliminate the possibility that hydrogen-burning stars comprise more than a fraction of the halo masses. Variations of the V-K color along and perpendicular to the disks show no sign of population changes toward redder objects at large galactocentric radii. The nucleus of NGC 5907 contains an unresolved source less than 330 pc in size with a 2.2-micron luminosity of order 5 x 10 to the 9th solar luminosity and may be an example of a starburst galactic nucleus overlooked by visual observations.

Skrutskie, M. F.↗