Extinction coefficient for red-shifted chlorophylls: Chlorophyll d and chlorophyll f
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The hexagonal close-packed (hcp) -martensite phase in steels nucleates from the -austenite parent phase and can undergo further transformation to the -martensite phase or exist as a metastable phase depending on temperature, mechanical loading, and alloy chemistry. The solute-dependent lattice parameters and elastic stiffness coefficients of hcp Fe influence the mechanical properties of steels containing the -martensite phase, as well as the martensitic transformations between the phases. We use density functional theory to calculate the lattice parameters and of single-crystal hcp Fe as functions of solute concentration in the dilute limit for the substitutional solutes Al, B, Cu, Mn, and Si, and the octahedral interstitial solutes C and N. Our computationally efficient methodology separates the solute dependence of the into lattice strain and chemical bonding contributions. The computed data can be used to estimate the effect of solutes on polycrystalline elastic moduli and the strain energy associated with martensitic transformations. The data can also serve as inputs to microstructure-based models of multiphase steels containing the -martensite phase.
We present a novel approach for solving steady-state stochastic partial differential equations in high-dimensional random parameter space. The proposed approach combines spatial domain decomposition with basis adaptation for each subdomain. The basis adaptation is used to address the curse of dimensionality by constructing an accurate low-dimensional representation of the stochastic PDE solution (probability density function and/or its leading statistical moments) in each subdomain. Restricting the basis adaptation to a specific subdomain affords finding a locally accurate solution. Then, the solutions from all of the subdomains are stitched together to provide a global solution. We support our construction with numerical experiments for a steady-state diffusion equation with a random spatially dependent coefficient. Our results show that accurate global solutions can be obtained with significantly reduced computational costs.
We present an overview of the challenges and practices of thermoelectric metrology on bulk materials at high temperature (300 to 1300 K). The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at high temperature. This has led to the implementation of nonideal practices that have further complicated the confirmation of reported high ZT materials. To ensure meaningful interlaboratory comparison of data, thermoelectric measurements must be reliable, accurate, and consistent. This article will summarize and compare the relevant measurement techniques and apparatus designs required to effectively manage uncertainty, while also providing a reference resource of previous advances in high temperature thermoelectric metrology.
A high temperature Seebeck coefficient measurement apparatus with various features to minimize typical sources of error is designed and built. Common sources of temperature and voltage measurement error are described and principles to overcome these are proposed. With these guiding principles, a high temperature Seebeck measurement apparatus with a uniaxial 4-point contact geometry is designed to operate from room temperature to over 1200 K. This instrument design is simple to operate, and suitable for bulk samples with a broad range of physical types and shapes.
Following our previous study of prototypical insertion reactions of energetically asymmetric type with the RPMD (Ring-Polymer Molecular Dynamics) method [Y. Li, Y. Suleimanov, and H. Guo, J. Phys. Chem. Lett. 5, 700 (2014)], we extend it to two other prototypical insertion reactions with much less exothermicity (near thermoneutral), namely, X + H{sub 2} → HX + H where X = C({sup 1}D), S({sup 1}D), in order to assess the accuracy of this method for calculating thermal rate coefficients for this class of reactions. For both chemical reactions, RPMD displays remarkable accuracy and agreement with the previous quantum dynamic results that make it encouraging for the future application of the RPMD to other barrier-less, complex-forming reactions involving polyatomic reactants with any exothermicity.
We present calculations of asymptotic normalization coefficients (ANCs) for one-nucleon removals from nuclear states of mass numbers 3{<=}A{<=}9. Our ANCs were computed from variational Monte Carlo solutions to the many-body Schroedinger equation with the combined Argonne v{sub 18} two-nucleon and Urbana IX three-nucleon potentials. Instead of computing explicit overlap integrals, we applied a Green function method that is insensitive to the difficulties of constructing and Monte Carlo sampling the long-range tails of the variational wave functions. This method also allows computation of the ANC at the physical separation energy, even when it differs from the separation energy for the Hamiltonian. We compare our results, which for most nuclei are the first ab initio calculations of ANCs, with existing experimental and theoretical results and discuss further possible applications of the technique.
Future accelerators require unprecedented cavity performance, which is strongly influenced by interior surface nano-smoothness. Electropolishing (EP) is the technique of choice being developed for high–field SRF cavities. Previous study has shown that the mechanism of Nb electropolishing proceeds by formation and dissolution of a compact salt film under fluorine diffusion-limited mass transport control. We pursue an improved understanding of the microscopic conditions required for optimum surface finishing. The viscosity of the standard electrolyte has been measured using a commercial viscometer, and the diffusion coefficient of fluorine was derived at a variety of temperatures from 0ºC to 50ºC using an Nb rotating disk electrode. In addition, data indicate that electrode kinetics becomes competitive with the mass transfer current limitation and increases dramatically with temperature. These findings are expected to guide the optimization of EP process parameters for achieving controlled, reproducible and uniform nano-smooth surface finishing of SRF cavities.
This study investigates the rheological properties, elastohydrodynamic (EHD) film-forming capability, and friction coefficients of low molecular mass poly-alpha-olefin (PAO) base stocks with varying contents of high molecular mass olefin copolymers (OCPs) to assess their shear stability and their potential for energy-efficient lubrication. Several PAO-OCP mixtures were blended in order to examine the relationship between their additive content and tribological performance. Gel permeation chromatography (GPC) and nuclear magnetic resonance (NMR) spectroscopy were used to characterize the molecular masses and structures, respectively. Density, viscosity, EHD film thickness, and friction were measured at 303 K, 348 K, and 398 K. Film thickness and friction were studied at entrainment speeds relevant to the boundary, mixed, and full-film lubrication regimes. The PAO-OCP mixtures underwent temporary shear-thinning resulting in decreases in film thickness and hydrodynamic friction. These results demonstrate that the shear characteristics of PAO-OCP mixtures can be tuned with the OCP content and provide insight into the effects of additives on EHD characteristics.
Force coefficient and moment coefficient correlations and air-helium simulation of spherically blunted cones - hypersonic wind tunnel testing
Supersonic study of configuration geometry effects on pressure-coefficient and section normal-force- coefficient distributions for two-stage launch vehicle
Intensities were measured for 97 lines of H2O vapor between 932 and 961 nm. The lines were selected for their potential usefulness for remote laser measurements of H2O vapor in the earth's atmosphere. The spectra were obtained with several different H2O vapor abundances and N2 broadening gas pressures; the spectral resolution was 0.046/cm FWHM. Measured H2O line intensities range from 7 x 10 to the -25th to 7 x 10 to the -22nd/cm per (molecules/sq cm). H2O self-broadening coefficients were measured for 13 of these strongest lines; the mean value was 0.5/cm per atm. N2-collision-broadening coefficients were measured for 73 lines, and the average was 0.11 cm per atm HWHM. Pressure shifts in air were determined for a sample of six lines between 948 and 950 nm; these lines shift to lower frequency by an amount comparable to 0.1 of the collision-broadened widths measured in air or N2. The measured intensities of many lines of 300-000 band are much larger than expected from prior computations, in some cases by over an order of magnitude. Coriolis interactions with the stronger 201-000 band appear to be the primary cause of the enhancement of these line intensities.
A correlation factor applicable for converting inviscid aerodynamic normal-force coefficients of simple shapes in helium to equivalent coefficients in air is found by using calculations based on the shock-expansion method at Mach numbers of 12, 16, and 20.
Soret and concentration diffusion coefficients for thermal diffusion columns, determined by unsteady state method
Not Available
Abstract not provided
The angular distributions of Drell-Yan charged lepton pairs in the vicinity of the Z-boson mass peak probe the underlying QCD dynamics of Z-boson production. This paper presents a measurement of the complete set of angular coefficients A 0–7 describing these distributions in the Z-boson Collins-Soper frame. The data analysed correspond to 20.3 fb –1 of pp collisions at √s = 8 TeV, collected by the ATLAS detector at the CERN LHC. The measurements are compared to the most precise fixed-order calculations currently available (O(α2s)) and with theoretical predictions embedded in Monte Carlo generators. The measurements are precise enough to probe QCD corrections beyond the formal accuracy of these calculations and to provide discrimination between different parton-shower models. A significant deviation from the (O(α 2 s )) predictions is observed for A 0 – A 2 . In conclusion, evidence is found for non-zero A 5,6,7 , consistent with expectations.